Air Permeability Tester FX 3300 LABOTESTER III

Similar documents
FX 3300 Air Permeability Tester III Scope

i-gastra 7200 Gas Permeability Tester

TitanUNIVERSAL STRENGTH TESTER

Model VDL 115 Vacuum drying chambers for flammable solvents

i-hydro 7900 Water Vapor Transmission Rate Testing System

Surface Roughness Testing

AUTOMATIC TENSION & COMPRESSION TESTING MACHINE

analysette 18 particle size analysis quality control sieving for your lab Heavy Duty Analytical Sieve Shaker

Model VD 23 Vacuum drying chambers for non-flammable solvents

USTER TESTER 5-C800. The filament yarn inspection system. Technical Data

Horizontal Sieve Shaker AS 400 control

TRIBOMETERS MICRO-MACRO TRIBOLOGY TESTING

Refrigerated incubators with forced convection

ProcessCalibrator Model CPH6000

UCI ASTM-A , DIN , JB-T

Ease of Use. Data at Your Fingertips LMS PHARMA

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

SIEVES 200mm.Ø x 50mm. STAINLESS STEEL FRAME

High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

ProcessCalibrator Model CPH6000

Flow Measurement SITRANS F M

USB pressure transmitter model CPT2500 with model CPA2500 USB adapter and USBsoft2500 software

Pneumatic precision pressure controller Model CPC6000

Pneumatic Precision Pressure Controller Model CPC6000

[ Capture Hoods. What is a capture hood?

AUTOMATIC CEMENT COMPRESSION & FLEXURAL MACHINES

B e n c h S c a l e KPZ 2E-06-N Stainless Steel DIN

NOTES. MiniTest. Dairy Vacuum & Pulsation Meter. User Manual. Part No. DR

High-end pressure controller Model CPC8000

FoamDDI. Foam Digital Detection Imaging

Introducing the world most advanced Shore/IRHD durometer DIGI TEST II

Discipline Mechanical Calibration Issue Date Certificate Number C-0386 Valid Until Last Amended on - Page 1 of 6

Flow Measurement SITRANS F M

LMI 4000 Series Melt Flow Indexers

MINIMAT-EC-Servo Screwdriver Spindles

Precision pressure indicator 1- or 2-channel version Model CPG2500

CalibratorUnit Models CPU6000-W, CPU6000-S, CPU6000-M

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Precision hand-held pressure indicator Model CPH6400

UPGRADE PROGRAM. V70 Series Pumps vs V81T Series Pumps

Advancing with Technology

0.03ºC (depending on ext. ref.) Input Port A: Range Res. Accuracy (% of reading) Pt100 2, 3 and 4-wire* -50 to 800ºC 0.01ºC ± 0.05ºC ±0.

Operating Manual. FSM-2 Field Strength Measuring Gauge Part Number

LMI 4000 Series Melt Flow Indexers

Minneapolis Blower Door Building Air tightness Testing Systems

System Description. FINO Semiautomatic Stencil Printer Version 1.1 July 11 th Modification protocol Version

5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4

Pressure range mbar / mbar

Pneumatic precision pressure controller Model CPC6000

Model KB 400 Cooling incubators with compressor technology

AB Axis Industries. Use

The NEW generation of AUTOMATIC compression testers An efficent solution to increase PRODUCTIVITY while SAVING ENERGY

Pneumatic precision pressure controller Model CPC6000

Pneumatic precision pressure controller Model CPC6000

Digital pressure gauge Data Sheet: DMM2.431.R1.EN

DMT PERFORMING UNDER PRESSURE DMT. With USB adapter and software. Applications. Special features. Description 1/7

Instruction manual Air sampling device

PT-TD300 - Tapped Density and Apparent Density Testing Instrument

Model 332 Differential Pressure Transmitter

SURFACE ROUGHNESS TESTER TR100/110

Air gap sensors SOPA

CS2. Advanced Force Test System. 225 lbf (1kN) & 1100 lbf (5kN)

Height Gauges. Height Gauges K-1

5. Operating instructions: Octagon 200CL

SPIRAL WOUND GASKET. Spiral Wound Gasket CALVOSEALING DESCRIPTION PROPERTIES

evolution C109N CYBER-PLUS C104N SERVO-PLUS section C CONCRETE

VAL-CP-1S-175. Extract from the online catalog. Order No.:

Issue 03/2013. The Electronic Load

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 NPT

Hand-held pressure indicator Model CPH6300-S1 (1-channel version) Model CPH6300-S2 (2-channel version)

XB4BS542 red Ø40 Emergency switching off pushbutton Ø22 latching turn release 1NC

Humidity goes Digital

Automatic Insulating In-Line Oil Tester DTA 100 E-AD

Relative, and differential pressure transmitter type 699

DBC 150/650 Series. Druck Dry Block Temperature Calibrators. GE Sensing. Features

MPI TS150-HP 150 mm High Power Manual Probe System For accurate High Power measurements up to 10 kv, 600 A

Bosch glove upgrades and accessories for barrier systems (RABS and isolator)

Model KB 240 Cooling incubators with compressor technology

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s

Instruction Manual P82R Differential Pressure Transducer with Root- Extracted Characteristic Curve

Model KB 400 Cooling incubators with compressor technology

IPC Global. EN Standards Tester

ProLab 1. ProLab 1000: ph for the professional. ph Meter ProLab 1000: Superior technique in a classy metal body. Precise measurements

AD Leak Tester INSTRUCTION MANUAL 1WMPD

D Issue A. Instruction Manual. Active Strain Gauge

AR2008 Digital Abbe Refractometer

1 Technical Specification IM1-P

BURSTING STRENGTH TESTERS

Connector System for Circular Contacts

MPI TS150-THZ 150 mm Manual Probe System

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

Rosemount 1595 Conditioning Orifice Plate

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Precimar. PLM and CiM Universal Length Measuring Machines LENGTH MEASURING MACHINES FOR HIGH-END CALIBRATION

Pneumatic High-Speed Pressure Controller Model CPC3000

A U T O C O L L I M A T O R S

AUTOMATIC MICRO-HARDNESS TESTER ISOSCAN HV1 OD

PT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.:

Hand-Held Pressure Indicator

Transcription:

Air Permeability Tester FX 3300 LABOTESTER III

SCOPE The TEXTEST Air Permeability Tester FX 3300 LABOTESTER III is used for fast, simple, and accurate determination of the air permeability of all kinds of flat materials and of foam cubes. The measuring range covers dense papers and airbag fabrics as well as extremely open non-wovens and forming fabrics. By means of the Evaluation Program LABODATA III the test results can be converted from "air permeability" into the "pressure drop at a given air velocity". This value, which is important for gas filter materials, is shown both, numerically and as a curve "pressure drop versus air velocity" in double logarithmic scale. The instrument works in accordance with AFNOR G 07-111, ASTM D 737, ASTM D 3,574, BS 5,636, DIN 53,887, EDANA 140.1, EN ISO 7,231, EN ISO 9,237, JIS L 1,096-A, TAPPI T 251, and other standards. It is suitable for laboratory use as well as for operation directly in the production area. FUNCTION The instrument works automatically and digitally. A powerful, muffled vacuum pump draws air through an interchangeable test head with a circular opening. For measurement the test head appropriate for the selected test standard is mounted to the instrument. The specimen is clamped over the test head opening by pressing down the clamping arm which automatically starts the vacuum pump. The pre-selected test pressure is automatically maintained, and after a few seconds the air permeability of the test specimen is digitally displayed in the preselected unit of measure. By pressing down the clamping arm a second time the test specimen is released and the vacuum pump is shut-off. Since the vacuum pump is automatically started when the test specimen is clamped in place over the test head opening, the test pressure builds up only after the test specimen has been clamped. This guarantees a perfect clamping of the test specimen thus significantly improving the measuring accuracy and greatly facilitating the operation of the instrument. The test pressure is digitally pre-selected in accordance with the test standard. It is automatically controlled and maintained by the instrument. Due to a true differential measurement the test pressure is measured accurately, even at high air flow rates. The air flow through the test specimen is measured with a variable orifice. The air permeability of the test specimen is determined from the pressure drop across this orifice, and is digitally displayed in the selected unit of measure for direct reading. High stability, precision pressure sensors provide for an excellent measuring accuracy and reproducibility of the test results. The proper function and calibration of the instrument can be checked in a matter of seconds by means of a calibration check plate. The instrument can be calibrated, and is supplied with an ISO conform calibration certificate. The long, free projection of the clamping arm of 50 cm (20") allows the operator to take measurements from large samples without having to cut small test specimens. By means of two extensions the working surface of the instrument can be increased to 120 x 60 cm. The instrument is not only suitable for laboratory use, but it is mobile and small enough to also be used directly in the production area. Operation of the instrument is extremely simple, so it can be operated without problem, even by inexperienced personnel. The instrument is equipped with a RS 232 data port for data output and remote control.

EVALUATION OF THE TEST RESULTS The simplest method for evaluation of the test results is to read the test results from the digital display, to write them down and to evaluate them manually. In order to eliminate all reading, writing and calculating tasks and related errors, the instrument can be connected to the Strip Printer L 5130 MINIPRINT, which documents the test results, including statistical analysis, on a 57 mm (2.25") wide strip of paper (see adjacent picture). Alternatively, the instrument can be connected to a PC or Laptop computer with the Evaluation Program L 5110 LABODATA III. The PC prints a comprehensive test report, including statistical analysis of the test results (see separate picture). In addition, it stores the test results on the hard disk and performs long-term evaluations based on various selection criterions. Up to five different TEXTEST instruments can be connected to the PC at the same time. The test results from these instruments can be processed simultaneously and documented together on the same test report. Thus, the Evaluation Program L 5110 LABODATA III turns the PC into a complete data processing system for the testing laboratory. AIR PERMEABILITY ID: Test press: 125 Pa Test area: 38 cm2 Instrument: FX 3300-III S/n: 923 Date: 23.6.2006 Time: 12:19 Operator: 1: 42.7 cfm 2: 53.8 cfm 2:ˆˆˆˆˆˆˆˆˆˆˆˆ deleted 2: 41.8 cfm 3: 45.6 cfm 4: 44.9 cfm 5: 42.0 cfm ------------------------ Avg: 43.4 cfm Min: 41.8 cfm Max: 45.6 cfm CV : 4.0 % ------------------------ Test report, printed with the Strip Printer L 5130 MINIPRINT (original size). TECHNICAL SPECIFICATIONS Measuring range: 0.4 through 750 cm 3 /cm 2 /s at 5 cm 2 test area 1 through 10,000 l/m 2 /s at 20 cm 2 test area 1 through 10,000 mm/s at 20 cm 2 test area 0.6 through 6,000 l/dm 2 /min at 20 cm 2 test area 0.008 through 5 dm 3 /s at 25 cm 2 test area 0.1 through 1,300 cfm at 38 cm 2 test area 0.05 through 700 cm 3 /cm 2 /s at 38 cm 2 test area 0.03 through 400 m 3 /m 2 /min at 38 cm 2 test area 2 through 24,000 m 3 /m 2 /h at 38 cm 2 test area 0.1 through 1,600 l/dm 2 /min at 100 cm 2 test area Unit of measure: mm/s, cfm, cm 3 /cm 2 /s, l/m 2 /s, l/dm 2 /min, m 3 /m 2 /min, m 3 /m 2 /h and dm 3 /s Measuring accuracy: better than ± 3 % of the displayed value Test pressure: 98 through 2,500 Pa (0.4 through 10" w.c.) Test head / test area: 5, 20, 25, 38 and 100 cm 2 (not included) Data port: RS 232 C, asynchronous, bi-directional Power requirements: 230 V, 50 through 60 Hz, max. 1,100 W Dimensions (w x d x h): 40 through 121x 92 x 106 cm Table height: 77.5 cm Projection of clamping arm: 50 cm (20") Net/gross weight: 60 / 80 kgs. The instrument is supplied with a calibration check plate, as well as an ISO conform calibration certificate. The test heads are, however, not included and must be ordered separately.

ACCESSORIES For the Air Permeability Tester FX 3300 LABOTESTER III the following accessories are available: FX 3300-XXX Test Heads for FX 3300 Test heads for various test standards, complete with clamping ring. (Please specify the desired test head(s) when ordering): Model FX 3300-5: 5 cm 2 (BS 5,636) Model FX 3300-20: 20 cm 2 (AFNOR G 07-111, DIN 53,887, EDANA 140.1, EN ISO 9,237) Model FX 3300-25: 25 cm 2 (ASTM D 3,574, EN ISO 7,231) Model FX 3300-38: 38 cm 2 (ASTM D 737, JIS L 1,096-A, TAPPI T 251) Model FX 3300-100: 100 cm 2 (for measurements on extremely dense samples). FX 3300-TRA Power Transformer for FX 3300 Built-in power transformer for operation of the FX 3300 Air Permeability Tester III on a line voltage of 100 V or 115 V. (Please specify the line voltage when ordering). L 5130 Strip Printer MINIPRINT For documentation and statistical analysis of the test results from various TEXTEST instruments on a 57 mm (2.25") wide strip of paper. L 5110 Evaluation Program for PC LABODATA III Program for documentation, statistical analysis, storage, and long-term evaluation of the test results from various TEXTEST instruments by means of an IBM compatible PC. FX 3300-LAP Mounting Kit for Laptop Computer Mounting kit to mount a laptop computer directly to the FX 3300 Air Permeability Tester III.

Your company name and address Test Report no. 2006.07.03, 12.51.00.LBD LBD143 Style: CMT 4322-200 Date/time: 07/03/2006, 12:51-07/03/2006, 12:52 Lot: 5360-06 Operator: J. Smith Piece: 12 Customer: Fabrics Ltd Static Air Permeability Test pressure: 125 Pa Date/time: 07/03/2006, 12:51-07/03/2006, 12:52 Test area: 38 cm² Instrument: Textest FX 3300-III, s/n: 923 1: 42.7 cfm 2: 53.8 cfm + «««deleted crease 2: 41.8 cfm 3: 45.6 cfm + 4: 44.9 cfm 5: 42.0 cfm Commentary: Avg: 43.4 cfm Nominal: 40.0 cfm 50.0 cfm Min: 41.8 cfm Min: 35.0 cfm 45.0 cfm Max: 45.6 cfm + Max: 45.0 cfm 40.0 cfm CV: 4.0 % Tests: 5 35.0 cfm CI: 5.0 % CI: 30.0 cfm 6 2 30.0 cfm 35.0 cfm 40.0 cfm 45.0 cfm 50.0 cfm Test Report no. 2006.07.03, 12.51.00.LBD Page 1