MODEL: MAKF. Lightning Surge Protectors for Electronics Equipment M-RESTER

Similar documents
MODEL: MAT3. [2] ALARM OUTPUT A: With Y: Without. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MD7ST. [3] LOOP DISCONNECT FUSE 0: Without 1: With (CENELEC/ATEX approval Not selectable)

MODEL: MD7TC. Lightning Surge Protectors for Electronics Equipment M-RESTER

DAL4 REPEATER MODEL. (SIN-NET, M-Bus use) MODEL & SUFFIX CODE SELECTION DAL4 TRANSMISSION ORDERING INFORMATION RELATED PRODUCTS GENERAL SPECIFICATIONS

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL MAT MODEL MAT3-240 MODEL

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

MODEL MAT MAT MODEL MAT2-240 MAT2-440

2U Congestion Alert Rack Insert for UK

MODEL: CND. Multiplex Transmission System

Surge Protective Device

MODEL: R2K-1 SEN TRONIC AG. R2K Series

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14

MODEL: 43AL1. Digital Panel Meters 43 Series

Thermal-Magnetic Circuit Breaker 2216-S

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Surge Protection Devices Ex9UE2

Surge Protection for Surveillance Systems

Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0

R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White.

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

Intersection Preassembled Backplate DC

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Model Number Structure

MODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Overvoltage Protection

Power Transducers. Measuring most electrical parameters

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Ferraz Shawmut TPMOV Principles and Operation

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

NEW surge protective devices

8 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

Surge Protection for Low Voltage Power Systems

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

Chameleon Stand-alone

70 SERIES. Line monitoring relay

Relay Deck Datasheet

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

3 Design of the electrical installation protection system

DAW 8/28/09. TITLE Specification I2R 120/240 RR 120V AC Split Phase Surge Protector PAGE 1 of 9 REVISIONS

HIGH PERFORMANCE MINIATURE SWITCHES WITH WIDE RANGE

Mini Digital Multimeter

PT 3-PB-ST. Extract from the online catalog. Order No.:

Zelio Control-modular measurement and control relays 1

RM84 miniature relays

LED Driver Compact fixed output

MODEL: 47LYV. Digital Panel Meters 47 Series

Surge & Filter Protection Addressing your industrial power quality needs.

G9SX-LM. Low-speed Monitoring Unit. Low-speed Monitoring Function Ensures Safety for Maintenance Work. Model Number Structure.

Miniature PCB Relays A

MODEL: 43DV2. Digital Panel Meters 43 Series

MODEL: 40DR SEN TRONIC AG. Digital Panel Meters 40 Series

User's Guide. Digital Multimeter. Model MN42

LED Driver Linear / area fixed output

M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS

MODEL: GR8-EM. Communication Adaptor GR8 Series

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-3: SURGE PROTECTOR PERFORMANCE AND EVALUATION CRITERIA

SURGE PROTECTOR. lighting. for.

Mini Digital Multimeter

E-Series General Specifications

ENGR. MARITES R. PANGILINAN, P.E.E.

MODEL: 40DV SEN TRONIC AG. Digital Panel Meters 40 Series

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

MODEL: 40DN. Digital Panel Meters 40 Series

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

Z-15GW2277 Z-15GW2277-B

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

RUC-M industrial relays for DC loads

DLS-E2 TELEMETERING UNIT BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (16 contact inputs & 16 open collector outputs)

Intersection Segmented Backplate

LED Driver Compact fixed output

MODEL: W2XR SEN TRONIC AG. Mini-MW Series

Click Desktop Kit. Click Desktop Kit

R1M-J3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL RTD & POTENTIOMETER INPUT MODULE MODEL. (8 points)

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

Ultra Slim Relays 24

78 Series Electromechanical Relay Selection Guide

LED Driver Linear / area fixed output

LED Driver Compact fixed output

60103 Circuit Breaker

MODEL: M2EXM. Super-mini Signal Conditioners with Display Mini-M M2E Series

Surge Protective Device

PLPC905GL-3-KNX / PLPC905GL-3-HD-KNX / PLPC905GL-4-KNX / PLPC905GL-4-HD-KNX LightMaster Dimmer Actuator

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Photovoltaic System Components Connection And Protection

POWER TRANSFORMERS, 1VA TO 180VA, FOR NORTH AMERICA, EUROPE

Transcription:

MODEL: Lightning Surge Protectors for Electronics Equipment M-RESTER OE-PORT SURE PROTECTOR FOR POWER SUPPLY USE Functions & Features Designed to protect electronics equipment from induced lightning surges entering through power supply cables Connected in parallel between the power and ground lines regardless of load current Varistor discharge element has a high speed response without follow current. o interruption of power supply even when the head element is removed: easy maintenance and replacing Degraded head element is automatically separated from the power lines to prevent overheating, with a relay contact output to alert the failure status. Head-base connection is keyed so that only a head element of correct line voltage can be mounted. Typical pplications Low-voltage distribution board Combination with installation for large load current 18 (.71) 97 (3.82) 65 (2.56) mm (inch) MODEL: [1][2] [2] OPTIOS Configuration /: Without alarm output /B: Head element for replacement RELTED PRODUCTS Single mount adaptor (model: MBS) Wiring bridge (model: CB) EERL SPECIFICTIOS Construction: Plug-in Degree of protection: IP20 (If the solderless terminals are covered with insulation tubes.) Surge protection type: Voltage limiting type one-port SPD Connection Line: M5 screw terminal (spring up-screw type) (torque: 2.5 m) larm output: Euro type connector terminal (torque: 0.25 m) pplicable wire size Line connection: See the sloderless terminal drawing. larm output: 0.14 to 1.5 mm 2 (7 mm exposed) Housing material: Flame-resistant resin (black) larm output: The SPDT relay trips when the thermal breaker operates and/or the head element is removed. Rated load: 250 V C @0.5 (resistive load) 125 V C @0.2 (resistive load) Minimum switching load: 5 V DC, 1 m Line voltage identification key: The connection of the head element and the base is keyed for exact matching. Safety function: Thermal breaker incorporated Failure indicator: The check window color changes from green (normal) to black (failed and the thermal breaker separated the M-rester from the circuit). pplicable Solderless Terminal Size diameter d B d : M5 use B 13.0 mm F 7.0 mm T 1.8 mm ORDERI IFORMTIO Code number: -[1][2] Specify a code from below for each [1] and [2]. (e.g. -120/) T F [1] OPERTIOL VOLTE 120: 120 V C 240: 240 V C 280: 280 V C 400: 400 V C 480: 480 V C ISTLLTIO Operating temperature: -5 to +55 C (23 to 131 F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: DI rail; Surface mounting available with the Single Mount daptor model: MBS. Weight: 100 g (3.53 oz) http://www.m-system.co.jp/ SPECIFICTIOS ES-8143 Rev.2 Page 1/5

MODEL: PERFORMCE Response time: 20 nsec. Maximum discharge current: 20k twice (8/20 μsec.) ominal discharge current: 5 k (8/20 μsec.) Insulation resistance: 100 MΩ with 500 V DC (line to alarm output) Dielectric strength: 2000 V C @ 1 minute (line to alarm output) Leakage current: 1 m at the discharge voltages listed in the table below. MODEL Uc DISCHRE Up VOLTE @1.0k (8/20 µs) @5k (8/20 µs) (C) (V) (Vmin) (Vmax) (Vmax) -120 150 250 600 800-240 275 420 1000 1400-280 320 460 1100 1500-400 440 670 1500 2100-480 530 820 1800 2500 Uc = Maximum continuous operational voltage Up = Voltage protection level COECTIO EXMPLES COFIURTIO EXMPLE: Single-phase / 2-wire connection a * 1 * 5 b * 2 * 3 rounding (100Ω or less) * 4 Cross-wiring *1. The circuit breaker must be installed. Molded-case circuit breakers (MCCB), earth leakage circuit breakers (ELCB) or current-limiting fuses (slow-blow type only) can be used. The rated interrupting capacity of the circuit breaker must be greater than the highest amount of current that could be available in the circuit. The MCCB or ELCB must has elements at both poles. Time-delay type over-current protection is recommended for an ELCB. Recommended sensitivity current rating: 30m *2. If the rated current of the circuit breaker a exceeds 30, or if the loss of power supply to the protected device should be prevented when the circuit breaker a blows due to a surge protector failure, install the circuit breaker b (rated current 20-30 ) at the branch circuit. *3. Cable length between the branch point and the grounding: 0.5 meters or less recommended. *4. The protected device s metal housing must be cross-wired to the ground terminal of the. If the protected device has no ground terminal, ground only the. *5. In order to protect an electronic circuit such as switching regulartors, we recommend to use surge protectors which have serial impedance incorporated such as M-System s models MX, MM, MH. http://www.m-system.co.jp/ SPECIFICTIOS ES-8143 Rev.2 Page 2/5

MODEL: COECTIO EXMPLES BY S bnormal voltages appearing in case of a light load or a ground loop must be within the maximum continuous operational voltage when selecting the models. For example, the IEC 60364-5-534 (Electrical installations of building; devices for protection against overvoltages) requires margins determined by the equations below: 3ph/4w, Y connec, TT system 3ph/4w, Y connec, T system 3ph/4w, Y connec, IT system Single-phase/2-wire connection L Uc (Max. Continuous Operational Voltage) Uc 1.5 Phase Voltage Uc 1.1 Phase Voltage Uc Line Voltage Three-phase/3-wire (delta connection) () 3-phase/3-wire, 200V C 3-phase/3-wire, 220V C 3-phase/3-wire, 400V C 3-phase/3-wire, 440V C -400x -480x Three-phase/4-wire (star connection, TT system) 1-phase/2-wire, 100V C 1-phase/2-wire, 200V C 1-phase/2-wire, 250V C -120x Single-phase/2-wire (three-phase delta connection grounded in the middle of phases) or single-phase/3-wire connection 3-phase/4-wire, 200/115V C 3-phase/4-wire, 220/127V C 3-phase/4-wire, 380/220V C 3-phase/4-wire, 415/240V C -400x -480x Three-phase/4-wire (star connection, T system) PE 1-phase/2-wire, 100V C 1-phase/2-wire, 200V C 1-phase/3-wire, 200/100V C 1-phase/3-wire, 400/200V C -400x -400x 3-phase/4-wire, 200/115V C 3-phase/4-wire, 400/230V C 3-phase/4-wire, 480/277V C 3-phase/4-wire, 690/400V C -120x -280x -400x LRM OUTPUT When the alarm output is to be transmitted remotely via outdoor cables, a surge protector for the signal line is required. Choose a circuit breaker with alarm output. Configure a logical addition sequence so that the alarm trips when both or either of the or the breaker alarm trips. http://www.m-system.co.jp/ SPECIFICTIOS ES-8143 Rev.2 Page 3/5

EXTERL DIMESIOS & TERMIL SSIMETS unit: mm (inch) MODEL: HED ELEMET & BSE, COMBIED SOLDERLESS TERMIL CCESS PORT 5 (.20) [30 (1.18)] 97 (3.82) 90 (3.54) 69 (2.72) CHECK WIDOW SPECIFICTIO LBEL 45 (1.77) 14 (.55) HED ELEMET O C C [1 (.04)] DI RIL TERMIL BLOCK FOR LMR OUTPUT (optional) BSE [1.5 (.06)] DI RIL 35mm wide 35.4 (1.39) 2 M5 SCREW DI RIL DPTOR RIP [3 (.12)] 18 (.71) : Place marking labels here. 51 (2.01) 65 (2.56) [1 (.04)] When mounting, no extra space is needed between units. HED ELEMET & BSE, SEPRTED MRKI LBELS (terminal identifiers, tag name labels) UIDI RIL VOLTE ID KEY E LRM OUTPUT LEVER SOCKET BSE SPECIFICTIO LBEL PLU MOUT POSITIO KEY http://www.m-system.co.jp/ SPECIFICTIOS ES-8143 Rev.2 Page 4/5

MODEL: SCHEMTIC CIRCUITRY & COECTIO DIRM * LIE / D Head Element * D / LIE Discharge Element Thermal Failure Indicator ** C LRM C OUTPUT O Base * M5 screw terminal **Terminal block provided for the alarm output option. Specifications are subject to change without notice. http://www.m-system.co.jp/ SPECIFICTIOS ES-8143 Rev.2 Page 5/5