XLF. Ex d. - Zones 1, 2, 21, 22 - Obstruction warnings - Stroboscopic lights - Single or double fixtures - Low wind resistance

Similar documents
M C. Ex d M-0... control, monitoring and signalling devices

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

Linear Luminaire with LED Series 6012/5

Linear Luminaire with LED Series 6412/5

Terminal Boxes Series 8118

SA-P. Ex e. Stainless steel captive screws. Metal plates riveted onto lid

Ex Junction Boxes & Control Stations

Tubular Light Fitting with LED Series 6036

Grounding Monitoring Device Series 8485

ATX FELED Series Nonmetallic LED Luminaires Standard and Emergency Battery Back-Up, Increased Safety

Control Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety

FELED Series Nonmetallic LED Luminaires Standard and Emergency Battery Back-Up, Increased Safety

Installation Equipments

Load Disconnect Switches and Motor Switches

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

Conveyor Belt Alignment Switches from IDEM

EX-PROOF HD CAMERA IN A COMPACT DESIGN EC-910-AFZ-Full HD IP 10 x Zoom

Grounding Monitoring Device Series 8485

Viamaster LED Series Luminaires For ATEX and IECEx Governed Hazardous Locations

21023, 21025, 2/2 Direct solenoid actuated poppet valves

Ex e Command, Control and Signalling Operators SERIES M-0603, M-0604, M-0605, M-0612

11W & 22W: Ex d e mb IIC T6 Gb, Ex tb IIIC T85 C Db II 2GD ABS Assessed: #11-LD PDA

Contender LED Luminaires Enclosed and Gasketed Fixtures

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

Throughwiring. single-ended. twin-ended

Safety switches with separate actuator

Viamaster LED Series Luminaires For NEC and CEC Governed Hazardous Locations

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Supplementary Components WirelessHART products

Product manual plug, sockets and coupler 16 A.- Z0251

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

Cable End Boxes Series 8146

Safety switches with manual mechanical delay and separate actuator

EX-BC36 PTZ series Explosion-proof analogue PTZ camera station

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

Safety switches with separate actuator

WirelessHART Adapter SWA70

Pneumatic Control/Feedback

Technical Data. General specifications. Rated operating distance s n 3 mm

95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves

EX-PROOF THERMAL ANALOGUE CAMERAS IN COMPACT DESIGN EC-840S-TIC-19A - Series

Pneumatic Control/Feedback

Technical Information Promonitor NRF560

Safety switches for hinged doors

Series 95000, 2/2 Direct solenoid actuated poppet valve

S 180 OPTICAL AND AUDIBLE MODULAR DEVICES. This is our idea that lead us to create and engineering this modular lamp. MODULAR CONFIGURATION

SPECIALTY PRODUCTS. Flameproof housing Zones 1-2 and to encase video cameras. Used for onshore and offshore sites and process supervision.

Operating pressure (bar) kv factor (m 3 /h) *3)

MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

2.3. Ex-Linear light fittings for fluorescent lamps. ellk W 58 W / ellm W 36 W (Zone 1, 2, 21, 22)

SKX 12 SKX 15. Zone. make your work surroundings safer IP 66

80265 series, 3/2 Indirect solenoid actuated poppet valve

Safety switches with separate actuator

Threaded resistance thermometer Miniature design Model TR10-D

ATX MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

Luminous Flux. Emergency operation

AllPro Hazardous/Corrosive Area Fluorescent

Sensor boxes SRBE Key features and product range overview

This installation guide provides instructions for installing the SPARTAN HP Highbay/ Floodlight series of explosion protected floodlights.

ExCos-P Pressure sensor 20 Pa Pa

Control Units Ex e in Stainless Steel LCS*.*

GRP Flameproof Visual Signal Xenon or Steady LED

HAZARDOUS AREA PTZ IP NETWORK CAMERA

Ex emergency pull-wire switches Ex ZS 71

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

Loads and Motor Switchgears

Technical data sheet Fila LED - FT0110-A4-P FILA LED

Threaded thermocouple Miniature design Model TC10-D

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Operating and monitoring systems Panel PC SERIES 400 Device platform SHARK ET-438-2FX

Dräger Polytron 8200 Stationary gas detector (CatEx)

General Specifications

Cable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof

Minimum cross sectional area of Conductor mm²

HAZARDOUS AREA DAY/NIGHT HD CAMERAS

Pneumatic Control/Feedback

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Page 1 of 5. Increased Safety, Encapsulation and Dust

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Indoor/ outdoor projector MINI-PROJECTOR-02 3LED VISIBLE Ufo-02

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Operating and monitoring systems Panel PC SERIES 400 Device platform SHARK MT-438-1TX

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Position Switches Series 8070

COEX 3000 TriMode Series 6 Ex d Camera Station

Series 3730 Type Electropneumatic Positioner

CHEP ATEX. IECEx. Explosion proof Camera Housing. and. Certified

Operating and monitoring systems Panel PC SERIES 400 Device platform SHARK ET-498-2TX

LS 5000 series Vibration Level Switch for liquids

THE BARRIER and the Universal Barrier Cabinets from Pepperl+Fuchs

InBin-P Pressure switches from 5 Pa Pa

Transcription:

XLF - Zones 1, 2, 21, 22 - Obstruction warnings - Stroboscopic lights - Single or double fixtures - Low wind resistance Polycarbonate Fresnel lens Fixture without Fresnel lens Painted aluminium body E.2

XLF series XENON obstruction lighting fixtures XLF series Xenon obstruction lighting fixtures are ideal for chimneys, towers, smokestacks, bell towers, buildings, cranes, bridges, radio/television masts, cable car and power line pylons, wind turbines, radar and telecommunication antennas and specifically for use in the petrochemical and oil industries. Their small size, light weight, ease of installation and robustness mean that XLF series lights do not deteriorate over time especially with exposure in salty environments. They are also resistant to the wind and the deposit of industrial dusts thanks to the low profile and aerodynamic properties of the body. Application sectors: Oil refineries CERTIFICATION DATA Chemical and petrochemical plants Classification: Installation: EN 60079.14 zone 1 - zone 2 (Gas) zone 21 - zone 22 (Dust) Ambient temperature: Degree of protection: Perimeter lighting 100% Cortem product II 2GD IIC T5 Gb; Ex tb IIIC Db IP66 ATEX TR CU Class temperature: Oil Combustible loading/un- liquid depots loading jetties Category 2GD IECEx Standards: Offshore plants Group II Marking: Certification: Onshore plants CESI 03 ATEX 046 IECEx CES 12.0020 All IEC Ex and TR CU certification data can be downloaded at www.cortemgroup.com AVAILABLE CENELEC EN 60079-0: 2009, EN 60079-1: 2007, EN 60079-7: 2007, EN 60079-31: 2009, EN 60598-1:2008+A11:2009, EN 60598-2-1:1989 and EUROPEAN DIRECTIVE 2014/34/UE European Directive 2006/95 Low voltage European Directive 2004/108 Electromagnetic compatibility European Directive 2003/108 WEEE Waste electrical and electronic equipment European Directive 2011/64 RoHS 100 C (T5) -20 C +55 C Special -50 C +40 C IP66 E.3

XLF series XENON obstruction lighting fixtures MECHANICAL FEATURES Body: Globe: Fresnel lens: Gaskets: Mounting: Bolts and screws: Entries: Coating: ORIGINAL PRODUCT Low copper content aluminium alloy Shock and temperature resistant borosilicate glass sealed with aluminium shade ring Transparent polycarbonate, shock and UV resistant Silicone acid/hydrocarbon resistant See XLF-1-2 series dimensional drawings Stainless steel 4 x 3/4 NPT threaded entries. Polyester coating Ral 7035 (light grey) : The STANDARD of the aluminium alloy used by Cortem has passed the tests required by standards EN60068-2-30 (hot/humid cycles) and EN60068-2-11 (salt mist tests) ELECTRICAL FEATURES Lamp holder: E27 ceramic Lamp: Stroboscopic (about 30 flash/min.) 6J or 16J Xenon with electronic module (for further information see EC SERIES ELECTRONIC MODULE CHARACTERISTICS ) Rated voltage: 24 VAC/DC, 110 VAC, 230 VAC Rated frequency: 50/60 Hz Connection: Direct to lamp holder L, N, Pe. Max section 4mm 2 The double lighting fixtures (XLF-...2) comes supplied wired and sealed up to the junction box, the connection is made to the terminal board inside the terminal box L, N, Pe. Max section 4mm 2 Power factor: 0.96 Wiring: Silicone rubber cables with glass braid protection against high temperatures ACCESSORIES AVAILABLE / SPECIAL REQUESTS Cable gland: FGAB2NBK for armoured cable or FB2NBK for non-armoured cable Model for conduit or pendant mounting (code: XLFS-1V1101) Special markings in II 2GD e IIC T5 Gb; Ex tb IIIC T.. Db IP66. (code: XLFE-1V1101) Ex or IP66 protected control panel with electronic modules GAS UNI ISO 7/1 thread Other colours: blue, yellow, green E.4

XLF series selection chart Code Lamp Colour Lamp power Power supply Weight Kg Xenon mm XLF-10241 XLF-10242 XLF-11101 XLF-11102 XLF-12301 XLF-12302 XLF-1R0241 XLF-1R0242 XLF-1R1101 XLF-1R1102 XLF-1R2301 XLF-1R2302 1 NO FRESNEL 6 Joule 24V AC DC 2 NO FRESNEL 6 Joule 24V AC DC 1 NO FRESNEL 6 Joule 110V AC 2 NO FRESNEL 6 Joule 110V AC 1 NO FRESNEL 6 Joule 230V AC 2 NO FRESNEL 6 Joule 230V AC 1 RED 6 Joule 24V AC DC 2 RED 6 Joule 24V AC DC 1 RED 6 Joule 110V AC 2 RED 6 Joule 110V AC 1 RED 6 Joule 230V AC 2 RED 6 Joule 230V AC XLF-20241 XLF-20242 XLF-21101 XLF-21102 XLF-22301 XLF-22302 XLF-2R0241 XLF-2R0242 XLF-2R1101 XLF-2R1102 XLF-2R2301 XLF-2R2302 1 NO FRESNEL 16 Joule 24V AC DC 2 NO FRESNEL 16 Joule 24V AC DC 1 NO FRESNEL 16 Joule 110V AC 2 NO FRESNEL 16 Joule 110V AC 1 NO FRESNEL 16 Joule 230V AC 2 NO FRESNEL 16 Joule 230V AC 1 RED 16 Joule 24V AC DC 2 RED 16 Joule 24V AC DC 1 RED 16 Joule 110V AC 2 RED 16 Joule 110V AC 1 RED 16 Joule 230V AC 2 RED 16 Joule 230V AC E.5

XLF series dimensional drawings XLF-... Structure mounting XLFS-... Conduit or pendant mounting XLF-...2 Double obstuction lighting fixture Close up of mounting XLF-... Dimensions in mm Close up of 6J Xenon lamp Close up of 16J Xenon lamp DON T FORGET TO ORDER THE ACCESSORIES Example: Type of lighting fixture Cable gland + + + other...see key XLF-1R1101 FGAB2NBK ACCESSORY E.6

Accessories and spare parts available on request XLF series ILLUSTRATION DESCRIPTION MODEL FEATURES CODE KEY Globe with shade ring Borosilicate glass globe Aluminium ring shade ring G50-0389FCM Red SR-1300 Polycarbonate Fresnel lens Green Yellow SR-1301 SR-1302 Blue SR-1303 O-ring Material: silicone OR-4512SH70S Ceramic lamp holder E27 250V 4A PORT E-27/X Structure mounting 4 x 3/4 entries G-0214 Pendant mounting 1 x 3/4 entry G-0213 Stroboscopic light with integrated module 6 Joule EC-06/624V 24V AC/DC 16 Joule EC-06/24V 6 Joule 110-230V AC/DC EC-06/6 16 Joule 230V AC EC-06 16 Joule 110V AC EC-06/110V Protective cage only for XLF without Fresnel Material: Electro-polished stainless steel G50-0417 ACCESSORY Cable gland For models and codes, visit www.cortemgroup.com FB2NBK FGAB2NBK ACCESSORY E.7

Features of EC series electronic modules for XLF CODE DESCRIPTION GRAPH VOLTAGE EC-06/110V Stroboscopic light 110V 16J 1 110 V ac/dc EC-06 Stroboscopic light 230V AC 16J 2 230 V ac/dc EC-06/6 Stroboscopic light 110-230V AC/DC 6J 3-4 110-255 V ac/dc EC-06/624V Stroboscopic light 24V AC/DC 6J 5 24 V ac/dc The waveforms have been designed to measure each module s exact consumption. Tests have been carried out using a resistance of 1 Ohm connected in series with the power supply so as to make the voltage conversion immediate. GRAPH 1-110 VAC E.8

Features of EC series electronic modules for XLF GRAPH 2-230 VAC GRAPH 3-110 VAC E.9

Features of EC series electronic modules for XLF GRAPH 4-255 VAC GRAPH 5-24 VAC E.10

Installation and mounting methods XLF series Example of XLF obstruction lighting fixture and ETS series siren installation N Description Code 1 1 Obstruction lighting fixture XLF-2R2301 2 Junction box ST-26.1V 3 Rotating electromechanical siren ETS60/109DB230V 2 8 8 3 4 Mounting plate 5 Nipple NP2G 4 6 3-piece union RMF2G 7 Sealing fittings EYS2 8 Sealed nipple NPSF2 5 6 7 Example of XLF obstruction lighting fixture and ETH series siren installation N Description Code 1 1 Warning sign XLF-2R2301 2 Junction box ST-26.1V 3 Siren ETH-20MD/12/5T 8 8 4 Mounting plate 5 Nipple NP2G 6 3-piece union RMF2G 7 Sealing fittings EYS2 8 Sealed nipple NPSF2 4 5 2 6 7 3 Features of EC series electronic modules.. for XLF EC-05 EC-10 EC-13 Double XLF power supply circuit in which a 16J stroboscopic lamp is the main light and the other lamp is a spare. Power supply: 230VAC Stroboscopic power: 16 J Power supply unit for EC-... with 230 VAC power supply. This unit has both automatic and manual controls as well as a test button. Fixed synchroniser that turns on all the stroboscopic lamps wired with a 230 VAC power supply at the same time. E.11