Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

Similar documents
Product and functional description

Product and functional description

Product and functional description

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Push Button Interface UP 220D31

Product and functional description

Product and functional description

Product and Application Description

Product and functional description

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Weather station AP 257/51

Weather station GPS AP 257/61 Weather station AP 257/51

Product and Applications Description

584 5WG AB_1 DELTA

DELTA profil wall switch, single UP 241/2 5WG AB_2

Push button UP 287, 4 - fold

DELTA i-system wall switch single UP 221/2 5WG AB_2

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

Interface AP 146 5WG AB01 for Ethernet-UDP/IP. EIB Device. EIB Device. EIB Device

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

252F 5WG FB_1 DELTA

Product and Function Description

DELTA i system wall switch single UP 221/2 5WG DB_2. wall switch double UP 222/2, 5WG DB_2. wall switch triple UP 223/2, 5WG DB_2

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Operating and mounting instructions

Operating voltage Maximum

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

1-channel shutter actuator 6A UP Installation Instructions

High-performance switching actuators

Product and Application Description

Extension module for lighting control

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

TXM1.8RB. TX-I/O Blinds module

Use of the application program. Contents overview. Gamma instabus Application program description. November 2016

DALI Professional Controller-4. Control unit Operating instructions

Digital input modules

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions

Room automation station

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

UNIVERSAL DIMMER DIM02SA/500U

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM04SA/500U

Product and function description

Room unit with PPS2 interface

Surface-Mounting Product Ranges

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

1 Safety instructions. 2 Device components. 3 Function. Control unit 1-10 V, 3-gang. Art.-No.: 2193 REG. Operationsmanual

KNX/EIB Flush-mounted universal dimming actuator 210 W. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Power supply module, bus connection module

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

Room Temperature Controller

Miniature Circuit Breakers for Railway Applications

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Room unit with PPS2 interface

ABB i-bus EIB / KNX Blower/Fan Coil-Aktuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

Electrical devices may only be mounted and connected by electrically skilled persons.

Operating Instructions

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Power Supply HARTING pcon

Resistance measuring module

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

Super universal modules

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

Operating instructions. Switching amplifier DN0210 DN / / 2015

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Room automation stations

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

6173 AG GJB A0138

CC COMPACT DIP SWITCH

Switching module for AC V and up to three load stages, with manual switching

Demonstration Case BENNING DB 1

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

ABB i-bus KNX HCC/S Heating/cooling circuit controller

Electrical Actuators

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Operating instructions. Speed monitor D / / 2014

Bus coupler 3 Bus coupler 3 external sensor Order No

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

Operating Instructions. DALI-Gateway

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

Non-communicating room controllers

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

PHOENIX CONTACT - 07/2006

Transcription:

Gamma instabus Technical Product Information RL 513D23 Switching actuator (relay), 3 x 6A 5WG1 513-4DB23 Switching actuator for independent switching of three lighting luminaire groups or other loads one relay contact (6A, AC 230V) per output as switching element, screwless terminals for connection and through-wiring of untreated single-core, stranded or multi-core conductors, 0.5... 2.5mm², Betrieb der Elektronik über Busspannung, Einbaugerät zur Montage in einer getrennt zu bestellenden Automationsmodulbox AP 118 oder Raumautomationsbox AP 641 Funktion bei Konfiguration mit der ETS counting of operating hours with threshold monitoring of the operating hours, counting of load cycles with threshold monitoring of the load cycles, integrated 8-bit scene control and linking of each output into up to 8 scenes, Siemens Spares Siemens AG RL 513D23 Update: http://www.siemens.com/gamma-td Control Products and Systems ã Siemens AG 2015 P. O. Box 10 09 53, D-93009 Regensburg Subject to change without further notice April 2015

Types Accessories Order number Type Applications KNX PL-Link 5WG1 513-4DB23 RL 513D23 Switching of lighting circuits or other loads Installation in an AP 118 Control Module Box or an AP 641 Room Control Box Purchased parts package Module for installation in AP 118 Control module box or in AP 641 Room control box Yes Type Order number Description 5WG1 118-4AB01 Automationsmodulbox AP 118 5WG1 641-3AB01 Raumautomationsbox AP 641 Features The RL 513D23 Switching actuator (relay) with mounting frame is a KNX device with three switching outputs. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus is connected via a bus terminal block. The actuator electronics are supplied via the bus voltage. Usage The RL 513D23 can switch resistive loads (e.g. electrical heaters, incandescent lamps, high voltage halogen lamps), inductive loads (e.g. motor, low voltage halogen lamps with intermediate conventional transformers), or capacitive loads (e.g. low voltage halogen lamps with intermediate electronic transformers). Functions (configuration with ETS) The actuator output may be configured independently to provide switching, manual override, forced control, logical gate, and status reporting. Furthermore, if required, time-limited switching instead of permanent switching on can be enabled for each channel via an optional "Night mode" object (e.g. for lighting while cleaning), if need be with a warning before switching off by multiple switching the output on and off (flashing). Amongst others, the application program includes optional a switching cycle and operating hours count with threshold monitoring for each output and an integrated 8-bit scene control, in which the output can be incorporated into up to 8 scenes. Each output of the actuator may be set to one of the following operating modes: - Normal operation - Timer operation 2 / 10 Update: http://www.siemens.com/gamma-td RL 513D23 Siemens AG ã Siemens AG 2015 Control Products and Systems April 2015 Subject to change without further notice P. O. Box 10 09 53, D-93009 Regensburg

Behavior at bus voltage failure / recovery Because the device electronics are powered by bus voltage a mains power failure only leads to a functional failure of the actuator if the bus voltage fails due to a failure of the mains voltage. Each actuator output is individually configurable regarding which switching position it shall take on bus voltage failure (Off, On, or No change) and which switching position it shall take on bus voltage recovery (Value prior to bus voltage failure, On, Off, or No change). On bus voltage failure the current switching status value is saved for restoration on bus voltage recovery. On bus voltage recovery the configured actions are executed and, if applicable, new status values are reported. Building site function The building site function provided ex-factory enables switching the building site lighting on and off via bus wall switches and actuators, even if these devices have not yet been commissioned with ETS. Factory default state In the default factory state all channels (outputs) are set to the function switching for the building site function. Behavior on unloading the application program When the application program is unloaded with ETS the device does not function. Resetting the device to factory default settings A very long push of the programming button (> 20 s) effects a reset to factory settings. This is indicated by constant flashing for 8 seconds. All configuration settings are lost. The building site function is re-activated. Addressing mode A short push of learning button (< 2 s) enables the addressing mode. This is indicated by a continuously lit programming mode LED. A second push disables this mode. Note A long push of the learning button (> 5 s and <20 s ) enables the Connection Test for commissioning with Desigo. Any time this mode can be disabled by a short push of the learning button. Application programs The RL 513D23 Switching actuator (relay) needs the application program 07 B0 A1 Switch actuator 982D02. The device is configured and commissioned with the ETS (Engineering Tool Software) version ETS3 v3.0f or later. Example of Operation binary output RL513D23 3 / 10 Siemens Spares Siemens AG RL 513D23 Update: http://www.siemens.com/gamma-td Control Products and Systems ã Siemens AG 2015 P. O. Box 10 09 53, D-93009 Regensburg Subject to change without further notice April 2015

Location and Function of the Display and Operating Elements, Interfaces A1 LED for indicating normal operating mode (LED off) or addressing mode (LED on); returns to normal operating mode automatically after receiving the physical address A2 Learning button for switching between normal operating mode and addressing mode and for receiving the physical address A short push of learning button (< 2 s) enables the addressing mode. This is indicated by a continuously lit programming mode LED. A second push disables this mode. Note: A long push of the learning button (> 5 s and <20 s) enables the Connection Test for commissioning with Desigo. Any time this mode can be disabled by a short push of the learning button. Factory settings: A very long push of the learning button (> 20s) effects a reset to factory settings. This is indicated by constant flashing of the addressing LED for 8 seconds. A3 Bus connection pins of the module for connection of the bus terminal block for single core conductors with 0.6 0.8 mm Ø A4 Type label (with space for physical address of the actuator) A5 Distance plate A6 Terminal Channel A A7 Terminal Channel B A8 Terminal Channel C A9 Distance plate A10 Terminal L A11 Identification number of the device Product Documentation Additional information like operating and mounting instruction, application program description, product database, additional software, product image, CE declaration etc. is available here: http://www.siemens.com/gamma-td Installation Notes Safety The device is intended for installation in an AP 118 Control Module Box or an AP 641 Room Control Box. DANGER The device must be mounted and commissioned by an authorized electrician. A safety disconnection of the device must be possible. The device must not be opened. For planning and construction of electric installations, the relevant guidelines, regulations and standards of the respective country are to be considered. When looping through the L-conductor, take care that the maximum permissible terminal load current of 16A is not exceeded! 4 / 10 Update: http://www.siemens.com/gamma-td RL 513D23 Siemens AG ã Siemens AG 2015 Control Products and Systems April 2015 Subject to change without further notice P. O. Box 10 09 53, D-93009 Regensburg

Mounting and Wiring Mounting RL module B2 RL module B3 Type label B4 Mounting location for RS / RL module in AP 118 Control Module Box or AP 641 Room Control Box B8 Learning button B9 LED for indicating - normal operating mode (LED off), - programming mode (LED on) B10 Bus connection pins of the module for connection of the associated bus terminal block of the internal bus wire B11 Insertion point for bus terminal block B12 Bus terminal block for single core conductors with 0,6 0,8 mm Æ B13 Hinge joint for mounting hinge of the RL module B14 Terminals Mounting of an RL module - Remove the lid of the AP 118 Control Module Box respectively of the AP 641 Room Control Box. - AP 641: Remove the SELV (Clas 2) cover - Insert the RL module (B2) into the hinge (B13) of the mounting location (B4). The terminals (B14) point away from the insertion point for the bus terminal (B11). The typle label (B3) is on top. - Swivel the RL module (B2) down until it audibly snapy into the mounting location (B4). - Insert the bus terminal (B12) of the mounting location (B4) onto the bus connection pins (B10) of the RL module (B2). - For assignment of the Phyiscal address press the learning button (B8) for a maximum of 2 seconds. The addressing mode is indicated when the LED is on (B9). It returns to normal operating mode (LED off) automatically after receiving the physical address. - AP 641: Mount the SELV (class 2) cover again. - Mount the lid again. Dismounting an RL module - Remove the lid of the AP 118 Control Module Box respectively of the AP 641 room control box. - AP 641: Remove the SELV (Class 2) cover. - Remove the wiring from the terminals (B14). - Remove the bus terminal (B12). - To remove the RL module (B2), insert a screw driver between the module and the mounting location on the bus terminal side and push it up to release it from the snap-in hooks. - Swivel the RL module (B2) up, pull it down out of the hinge (B13) and remove it from the mounting location (B4). - AP 641: Mount the SELV (class 2) cover again. - Mount the lid again. Siemens Spares 5 / 10 Siemens AG RL 513D23 Update: http://www.siemens.de/gamma-td Control Products and Systems ã Siemens AG 2015 Postfach 10 09 53, D-93009 Regensburg Änderungen vorbehalten April 2015

Wiring Slipping off/on bus connection blocks The bus terminal block (C2) consists of two components (C2.1 and C2.2) with four terminal contacts each. Take care not to damage the two test sockets (C2.3) by accidentally connecting them to the bus cable or with the screw driver (e.g. when attempting to unplug the bus terminal block). Slipping off bus connection blocks - Carefully put the screw driver to the wire insertion slit of the bus terminal block s grey component (C2.2) and - pull the bus terminal block (C2) from the module. Note: Don t try to remove the bus connection block from the bottom side. There is a risk of shorting-out the device! Slipping on bus connection blocks - Slip the bus terminal block (C2) onto the guide slot of the module and - press the bus terminal block (C2) down to the stop. D1 Connecting bus cables - The bus terminal block (D2) can be used with single core conductors Ø 0.6 0.8 mm. - Remove approx. 5 mm of insulation from the conductor (D1) and plug it into the bus terminal block (D2) (red = +, grey = -) D2 D2 Disconnecting bus cables - Unplug the bus terminal block (D2) and remove the bus cable conductor (D2.4) while simultaneously wiggling it. Connecting/disconnecting mains and load circuit Connect wires - The load circuits are connected via screwless plug-in terminals (E1). - Remove approx. 9 10 mm of insulation from the wire (E 1.1) and plug it into the terminal (E1). - The terminals are designed for connection of two wires allowing to loop through the terminal block. Note: The maximum permissible terminal load current is 16A. Remove wires Press the terminal interlocking ot the terminal (F1) with a screwdriver and remove the wire (F2) from the terminal (F1). 6 / 10 Update: http://www.siemens.com/gamma-td RL125/23 Siemens AG ã Siemens AG 2015 Control Products and Systems April 2015 Subject to change without further notice P. O. Box 10 09 53, D-93009 Regensburg

Technical data Power Supply Power Supply KNX bus voltage KNX bus current Thermal dissipation los via the bus line DC 24V (DC 21 30V) via KNX/EIB bus line < 10 ma Device: 0,15 W (=min. total thermal dissipation loss) per output: 0,022 * (Ieff)² [W] min. total thermal dissipation loss: 0,15 W(load: 0A) max. total thermal dissipation loss: 2,09 W (load: 2x 6A, 1x 4A) Outputs Number 3 outputs Switching output, potential-free relay contacts - rated voltage: AC 230V, 50/60 Hz Switching characteristic - rated current: 6A (resistive load) - switching current at AC 230V: 0,01 6A resistive load - switching current at DC 24V: 6A resistive load 4A inductive load (4R=7ms) - max. relay position changes per minute: 60 Set in parameter list according to application program Switching capacity at AC 230V For incandescent lamp load max. 1000W For fluorescent lamp load (LL) - uncompensated LL, cosj = 0,5: max. 500W - parallel compensated LL, cosj =1 (at Cges <= 14mF): 2 x 58W oder 3 x 36W oder 6 x 18W - Duo-configuration, cosj = 1: max. 1000W - OSRAM ECG for 58W LL: max. 10 pieces - OSRAM ECG for 36W LL: max. 15 pieces - OSRAM EVG for 18W LL: max. 20 pieces Display elements 1 red LED for monitoring bus voltage and for displaying normal mode / addressing mode Control elements 1 learning button for switching between normal operating mode and addressing mode Connections Bus line Load circuit bus connection pins for connection of the screwless bus terminal block (red-black), 0,6 0,8 mm Ø single-core, strip insulation 5mm screwless terminals 0,5 2,5 mm 2 single-core, stranded or multi-core, untreated, strip insulation 9 10 mm 7 / 10 Siemens Spares Siemens AG RL 513D23 Update: http://www.siemens.com/gamma-td Control Products and Systems ã Siemens AG 2015 P. O. Box 10 09 53, D-93009 Regensburg Subject to change without further notice April 2015

Physical specifications Housing Dimensions (L x W x D) Weight Fire load Installation plastic 86,5 x 47,8 x 36,2 mm approx. 62 g approx. 2 MJ Mounting location for RS / RL module in AP 118 Control Module Box (5WG1 118-4AB01) or AP 641 Room Control Box (5WG1 641-3AB01) Environment and safety regulations Degree of pollution (according to IEC 60664-1) Overvoltage category (according to IEC 60664-1) Protection type (in accordance with EN 60529) IP 20 Electrical Safety Bus Device complies with Relay Electromagnetic compatibility Environmental conditions Climatic conditons Ambient operating temperature Storage temperature Relative humidity (not condensing) Reliability 2 III safety extra low voltage SELV DC 24V EN 50428 with µ- contact complies with EN 50428 EN 50090-2-2-5 +45 C -25 +70 C 5 % to 93% Failure rate 395 fit at 40 C Markings CE mark KNX EIB Complies with the EMC regulations (residential and functional buildings), low voltage regulations, and RoHS Directive 8 / 10 Update: http://www.siemens.com/gamma-td RL 513D23 Siemens AG ã Siemens AG 2015 Control Products and Systems April 2015 Subject to change without further notice P. O. Box 10 09 53, D-93009 Regensburg

Dimension Drawing Dimensions in mm Support General Notes The operating instructions must be handed over to the client. A faulty device shall be returned with a Return Good Note for Service provided by the appropriate Siemens sales office. If you have further questions concerning the product please contact our technical support. ' +49 (911) 895-7222 7 +49 (911) 895-7223 * support.automation@siemens.com www.siemens.de/automation/support-request 9 / 10 Siemens Spares Siemens AG RL 513D23 Update: http://www.siemens.com/gamma-td Control Products and Systems ã Siemens AG 2015 P. O. Box 10 09 53, D-93009 Regensburg Subject to change without further notice April 2015

Published by Siemens AG Control Products and Systems P. O. Box 10 09 53, D-93009 Regensburg 2015 Copyright Siemens AG Subject to change without further notice Update: http://www.siemens.com/gamma-td April 2015 10 / 10