QUICK START GUIDE Generator Protection Unit GPU 300

Similar documents
QUICK START GUIDE Paralleling and Protection Unit PPU 300

QUICK START GUIDE Paralleling and Protection Unit PPU 300

MULTI-LINE 2 APPLICATION NOTES

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs

QUICK START GUIDE Generator Paralleling Controller, GPC-3 Generator Protection Unit, GPU-3/GPU-3 Hydro Paralleling and Protection Unit, PPU-3

DEIF A/S. Description of options. Option C2, Generator add-on protection package Automatic Gen-set Controller. Description of option

AGC 200 Advanced Gen-set Controller What s in the delivery? Getting started The first steps Using the AGC 200

OPERATOR'S MANUAL Generator Paralleling Controller, GPC-3 - Generator Protection Unit, GPU-3/GPU-3 Hydro - Paralleling and Protection Unit, PPU-3

Automatic Genset Controller, AGC-3 What's in the delivery Getting started The first steps Using the AGC

Option X4 Additional Operator Panel AOP-2 Description of option Functional description

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

Getting started - USW 3.x Software download from internet Software installation Device setup Data backup

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

MULTI-LINE 2 APPLICATION NOTES. Converting PPU-2 to PPU-3 Parameter conversion Wiring Options I/O list. Document no.: A SW version:

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

DEIF A/S. Description of options. Option C1 Generator add-on protection package Multi-line 2 version 2. Description of options. Functional description

Option P1 Event and alarm printer Description of option Functional description Parameter list

DEIF A/S. Description of options. Option P1, Event and alarm printer Automatic Gen-set Controller. Description of option. Functional description

DEIF A/S. Description of options. Option A and B, Loss of mains protection package Automatic Gen-set controller. Description of options

Option H10, Multi-line 2 unit with USB service port. To be used when the multi-line 2 unit service port is USB type

Genset control and protection with safety system

Inverter Interface Interface examples Wiring examples Communication topology

APPLICATION NOTES H-coupling

DEIF A/S. Description of options. Option H4 Serial comm. CAT CCM communication Multi-line 2 version 2. Description of option Functional description

Option H8.x and H12.x External I/O modules Description of option Functional description

Option M2 Configurable engine control cards Multi-line 2 version B SW version 2.4X.X

Compact Genset Controller, CGC 200 Mounting Terminals and wiring Commissioning, using the Utility Software and/or the front panel

Advanced Graphical Interface, AGI 100

CODESYS v. 2.3, Ethernet driver for AGI 3xx Use the CODESYS Ethernet driver in the AGI Creator Set up the CODESYS for use with the AGI Creator

Description of options. user s manual. DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: Fax:

Generator Protection Unit, GPU Hydro Multi-line A SW version 2.4X.X

Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus

APPLICATION NOTES Translations

EAP 300 REMOTE ANNUNCIATOR INSTALLATION MANUAL. r.0454a

MULTI-LINE 2 APPLICATION NOTES. Converting PPM-2 to PPM-3 Parameter conversion Wiring Options I/O list Modbus. Document no.: A SW version:

SEM3 - Embedded Micro Metering Module

Installation Manual. Multi Power Controller MPC-1 multi-line D

Vision OPLC V TR20/V350-J-TR20

APPLICATION NOTES DELOMATIC 4, DM-4 GAS/HYDRO

DATA SHEET Compact Genset Controller, CGC 200

Insight Installation of FX30 Data Acquisition Unit (DAU) Login to Insight Setup Insight with your equipment in the cloud Related system information

Genset Controller Unit Model EMS - GC10. Installation Manual Section

DATA SHEET Advanced Graphical Interface, AGI 100 series

Electrical network protection Sepam series 20 Sepam series 40 Quick start

Instruction Bulletin. Sepam Series 20 & 40 Relays Quick Start Guide

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Automatic Sustainable Controller, ASC Mounting Board slot positions Terminal strip overview I/O lists Wiring

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

MIC-2 MKII I/O module user s manual

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

DATA SHEET Advanced Graphical Interface, AGI 100 series

INSTALLATION INSTRUCTIONS

MIC-2 MKII Profibus module user s manual

PowerLogic ION7550 RTU option

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

BCM2 Series Branch Circuit Monitors Quick Setup Guide

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Model 7705 Control Module

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Rack Mount Power Supplies

Engines & Gen-sets N, page 1 of 6

OPLC Installation Guide

MULTI-LINE 2 DESCRIPTION OF OPTIONS

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed

MIC-2 Multi-instrument DATA SHEET

Power Xpert Meter 2000 Gateway Card Kit

SPARE PART ONLY. Basic Gen-set Controller Multi-line H SW version 2.31.X or later. Data sheet. Standard functions

Basic Gen-set Controller multi-line F SW version 2.31.X or later

Vision OPLC V TR6/V350-J-TR6

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

Basic Gen-set Controller G (UK) SW version 2.1X.X. Terminal strip overview

MARINE & OFFSHORE SHIP ENERGY MONITORING SYSTEM

Vision OPLC. V T38 Installation Guide. General Description

PM Series Power Meter

Model 2380 Rack-Mount Kit

Installation Job Aid for Ethernet Routing Switch 3600 Series

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

DATA SHEET Selectable AC transducer, TAS-331DG

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

Installing and Configuring Rialto Analytic Appliances

PacketBand TDM-4 Quickstart Guide V3.2

Installation manual CF8-W-Disp-AL

Multi-Point Gas Detection and Control System

PowerFlex 700S and 700H Frame 11 Replacement Power Structures

Sidewinder Pumps Inc. AC Timer/Controller

Contents 1 Warnings, Cautions, and Notes Description Features... 1

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Generator Protection Unit, GPU-3 Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General

Delomatic 4, DM-4 Marine & Offshore DATA SHEET

Removing Components from the MX960 Chassis Before Installing It Without a Lift

GCI-5K INSTALLATION AND OPERATOR S MANUAL

Transcription:

QUICK START GUIDE Generator Protection Unit GPU 300 DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 Info@deif.com www.deif.com Document no.: 4189341035A

1. Introduction 1.1 About the quick start guide...3 1.1.1 General purpose...3 1.1.2 Software version...3 1.2 Warnings and safety...3 1.2.1 Safety during installation and operation...3 1.2.2 Controller power supply...3 1.2.3 Factory settings...4 1.2.4 Electrostatic discharge...4 2. Hardware setup 2.1 Mount the hardware...5 2.1.1 Controller mounting...5 2.1.2 Display unit mounting...6 2.2 Wire the hardware...7 2.2.1 Wire the controllers...7 2.2.2 Wire the communication...7 2.2.3 Wire the power supplies...8 3. Software setup 3.1 PICUS...9 3.1.1 Download and install...9 3.1.2 First time log on...9 3.2 Software configuration...10 3.2.1 Configure inputs and outputs...10 3.2.2 Configure parameters...11 4. Display unit overview 4.1 Display unit overview...12 www.deif.com Page 2 of 13

1. Introduction 1.1 About the quick start guide 1.1.1 General purpose This is the quick start guide for DEIF s Generator Protection Unit, GPU 300. The guide provides the basic information to install and configure the GPU 300. Refer to the Designer's handbook, Installation instructions, Commissioning guidelines and PICUS manual for more information. 1.1.2 Software version This Quick start guide corresponds to the following software versions. Table 1.1 Software versions Software Details Version PCM APPL Controller application GPU 300 1.0.x.x DU APPL Display unit application GPU 300 1.0.x PICUS PC software 1.0.x.x 1.2 Warnings and safety 1.2.1 Safety during installation and operation Installing and operating the equipment may require work with dangerous currents and voltages. The installation must only be carried out by authorised personnel who understand the risks involved in working with electrical equipment. DANGER! Hazardous live currents and voltages. Do not touch any terminals, especially the AC measurement inputs and the relay terminals. Touching the terminals could lead to injury or death. 1.2.2 Controller power supply If the controller has no power supply, it is OFF and does not provide any protection to the system. The controller cannot enforce any trip, block, or latch when it is off. All the controller relays de-energise. The controller must have a reliable power supply, which must include a backup power supply. In addition, the switchboard design must ensure that the system is sufficiently protected if the controller power supply fails. www.deif.com Page 3 of 13

1.2.3 Factory settings The controller is delivered pre-programmed from the factory with a set of default settings. These settings are based on typical values and may not be correct for your system. You must therefore check all parameters before using the controller. 1.2.4 Electrostatic discharge You must protect the equipment terminals from static discharge during handling, including installation and dismounting. Once the equipment is correctly installed and the frame ground is connected, it is no longer necessary to protect the terminals from static discharge. www.deif.com Page 4 of 13

20.0 (0.79) MIN 175.0 (6.89) 20.0 (0.79) MIN GPU 300 Quick start guide 4189341035 UK 2. Hardware setup 2.1 Mount the hardware 2.1.1 Controller mounting A 212.9 (8.38) PSM PCM B Detail A Detail B 1. Check the available space at the vertical mounting position. There should be a minimum of 20 mm (0.79 inches) of free space above and below the controller for ventilation. INFO More free space might be required for the communication cable connectors and the cable bend radius. 2. Mount the rack at the mounting position with the PSM on the left and the PCM on the right when looking at the controller from the front. 3. One mounting position should be grounded. See Detail A. INFO The grounded position must have a toothed lock washer between the controller foot and the earth connection. www.deif.com Page 5 of 13

2.1.2 Display unit mounting 220.0 (8.66) 160.0 (6.30) 20.0 (0.79) MIN A 20.0 (0.79) MIN Detail A a b c d *Click* 1. Check the available space at the vertical mounting position. There should be a minimum of 20 mm (0.79 inches) of free space above and below the controller for ventilation. INFO More free space might be required for the communication cable connectors and the cable bend radius. 2. Slide the display unit into the mounting position. 3. Click in, and fasten the securing screws. See Detail A. www.deif.com Page 6 of 13

2.2 Wire the hardware 2.2.1 Wire the controllers Connect the wires to the front of the controller modules according to the system design. CAUTION Do NOT connect the power cables at this time. Refer to the Designer's handbook, Installation instructions and Commissioning guidelines for more information. 2.2.2 Wire the communication Figure 2.1 Example of how communication wires can be connected 1 2 Service PC (PICUS) PSM PCM Controller 3 Display 1 4 5 SCADA AMS Modbus TCP/ IP Connect the communication wires according to the system design. The diagram shows the recommended default connection for the Ethernet cables. The service PC, SCADA, alarm management system (AMS)and modbus TCP/IP connections can be connected to any controller in the network. www.deif.com Page 7 of 13

2.2.3 Wire the power supplies CAUTION Ensure the power supply is OFF before connecting the power supply to the controllers and display units. 1 3 12/24 V DC 0 V DC 1 2 2 PSM 3.1 12/24 V DC + 0 V DC - 12/24 V DC 0 V DC 1. Connect the wires from the power supply to the power terminal blocks for the controllers and the display units. 2. Insert the power terminal blocks into the power terminals of the controllers' modules. 3. Insert the power terminal blocks into the power terminals of the display units. 4. Turn on the power. www.deif.com Page 8 of 13

3. Software setup 3.1 PICUS 3.1.1 Download and install 1. Visit http://www.deif.com/software/software-download. 2. Select PICUS software from the list and submit your email address to receive a download link. 3. Follow the link in the email to download the software. 4. Launch the PICUS installer. 5. Follow the on-screen instructions to install PICUS. CAUTION PICUS uses Bonjour for the network detection on the DEIF network. You must install Bonjour, or already have this installed on your computer. 3.1.2 First time log on Logon 1. Connect the service computer, with PICUS installed, to the controller. 2. Launch PICUS from the installed location. 3. In PICUS, select the controller from the list and select Connect at the bottom of the window. 4. Select the Admin user (default password: 00000004). 5. Log on using the default password. Change administrator password 1. Go to Tools > Advanced > Permissions > Users. 2. Select Admin and click Edit. 3. Confirm the Old password, then enter and confirm the New password. Select Save. 4. Click Write in the right side panel. Change date and time 1. Go to Tools > Date and time. 2. Enter the correct date and time. 3. Click Write in the right side panel. See the PICUS manual for more information. www.deif.com Page 9 of 13

3.2 Software configuration 3.2.1 Configure inputs and outputs 1. Go to Configure > Input/output. 2. Select the controller module to configure. 3. Select the terminal to configure. 4. Configure the terminal and click Save when the configuration is complete. 5. Repeat step 3 and step 4 for the remaining terminal configurations. 6. Click Write in the right side panel. INFO You only configure the controller that you are Logged on and Connected to. www.deif.com Page 10 of 13

3.2.2 Configure parameters 1. Go to Configure > Parameters. 2. Select the parameter group that you want to configure from the list. 3. Select and configure the parameter. Additional information about the parameter that you are configuring is displayed under Info. 4. Repeat step 2 and step 3 for the remaining parameters. 5. Select Write in the right side panel. INFO You only configure the controller that you are Logged on and Connected to. www.deif.com Page 11 of 13

4. Display unit overview 4.1 Display unit overview 1 10 Configure Tools Info 2 Log on Alarm Log Live data 9 8 3 7 6 5 4 Number Name Function 1 Screen Displays the menus and status of the connected controller. 2 Navigation push buttons Eight push buttons to navigate the menus and make configurations. 3 Help Opens help for the screen that you are viewing. 4 Display unit configurable folio The LEDs and picture on the bottom of the folio vary according to the display unit option chosen. www.deif.com Page 12 of 13

Number Name Function 5 Busbar LED 6 Breaker LED 7 Generator LED Green: The busbar voltage and frequency are OK. Green (flashing): The busbar voltage and frequency are OK, but the V&Hz OK timer is still running. Yellow: The busbar voltage and frequency are measurable, but not OK. Red: The busbar voltage is too low to measure (for example, during a blackout). Green: The breaker is closed. Red: The controller tripped the breaker, and the trip alarm is unacknowledged and/or the alarm condition is still present. Red (flashing): Any generator breaker trip alarm is active. OFF: The breaker is open. Green: The generator voltage and frequency are OK. Green (flashing): The generator voltage and frequency are OK, but the V&Hz OK timer is still running. Yellow: The generator voltage and frequency are measurable, but not OK. The breaker cannot close. OFF: The generator voltage is too low to measure. 8 Silence horn Stop the horn output immediately. 9 Alarm LED Controller status LEDs Red (constant): Alarm(s) active, and all alarms acknowledged. Red (flashing): Unacknowledged alarm(s). Yellow: Unlatched alarms can be reset (when no other alarms require action). Green (flashing): Only unacknowledged alarm(s) where the alarm condition has cleared. Green (constant): No alarms. 10 Display unit power OK Self-check OK Ready for operation Green (constant): The display unit power is OK. OFF: The display unit power is not OK. Green (constant) The controller self-check is OK. OFF: The controller self-check is not OK, or there is no connection to the controller. Green (constant): There is no alarm action (trip) that prevents the equipment from connecting and supplying power. OFF: There is an alarm action (trip) that prevents the equipment from connecting and supplying power. www.deif.com Page 13 of 13