FTK5 PROXIMITY KEYPAD

Similar documents
AS Keypad User Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual

Digital Keypad Introduction

Single Door Standalone Access Control User Manual

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

Waterproof. Keypad/Reader/Controller

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

CM-110SK Standalone Keypad Installation Instructions

K44 Code lock. Technical manual

RFID/Digital Access Control Keypad

W3-M. Metal waterproof standalone access control/reader. User Manual

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

ACTsmart2 Product Range Operating and Installation Instructions

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

EL-ST100 KEYPAD CONTROLLER

DOLXFD1000B. Waterproof Access Control/Reader

User Manual. PCKeypad Wireless Keypad

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

180 Series Keypad. Handbook. Revision 2.1

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

Specifications: Features:

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

SK-1011-SQ Digital Access Keypad with 5A Relay Output

User Manual. Split access control with intelligent secured power supply.

MULTIWAY 2-12 WAY DOOR ENTRY SYSTEM

Fingerprint Access Control F1. User Manual

BC Digital Keypad. User Manual

CM-500 SK 500 USER CODES KEYPAD

Access Control Keypad

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

XP-KIT. Programming & Operations. Programming Starter Kit for Aiphone -XP Series Proximity Reader Stations

.

BACK-LIT KEYS KEYPAD 100 USER CODES FLUSH MOUNT

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions

Installation Manual. GSM-3V/AB & ABK V3.5 (1200 keypad) Wiring. Important Notes: SIM card. Installation

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

Installation and User Manual

W3-H Waterproof Keypad/Reader/Controller

Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader

ZDL-V200. Refer to Steps: 1 Thru. 4 Please Follow Wiring Steps Carefully.

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

Set-up of ZK RFID Pin Pad

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you

ENFORCER SK-1131-SQ. Digital Access Keypad with 5A Relay Output MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

ACTpro Single Door IP Controller. Operating & Installation Instructions

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

KP2000E/EM Series Style Keypad

INSTALLATION INSTRUCTIONS 923P EntryCheck TM

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

INSTALLATION INSTRUCTIONS 2916P

ACTentry A5 Kit. ACTentry A5 Entry Panel. Audio Door Entry with Access Control. Audio Door Entry & Access Control Kit Features

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

GV-Card Reader. User s Manual

Installing Keypad and Backplate

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD

VIDI-AC-2CS Access Controller/ Reader

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

AK-21. Digital Keyless Entry System. Installation and Programming Instructions

RBR-SB-KTZ001 LAR 2. User Manual

Keypad Programming Instructions For the Access 800 Series Locks

-DTZ001- Stand-Alone Proximity Access Control. User Manual

PX/QX/RX Version User Manual. Issue B

DG Series. Access Control Proximity Readers DG-160 DG-800

Non-contact or proximity card access control using the manual

ACTpro 1500 Single Door IP Controller

Synergis Master Controller 2.2 Integration Guide for Axis Interface Modules

Created by: Alarm System Store Quick Start Guide. for Interlogix NetworX NX4, NX6 & NX8

INSTRUCTION MANUAL AC-T43 PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT. 07/04

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

VIS-3200 / VIS-3201 User Manual

Stand-alone Proximity Access Control

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

AT61 GSM Text Auto Dialer Manual

801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

REX F-0-9 Standalone or Access Controller

Access 800TM. Keypad Programming Instructions. Locks CYLINDRICAL EXIT MORTISE

INSTALLATION INSTRUCTIONS 2916

Outdoor Stand-Alone Weatherproof Keypads

HSY-S209 EM Metal waterproof access control system User Manual

SOFTWARE VERSION 3.20

DINB100-SA-KIT Standalone Biometric Kit

Installers & User guide Deadbolt 2S.

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

SYRIS SY110SA. Operating Manual. Ver:1.60

ENFORCER. SK-1123-SQ Outdoor Digital Access Keypad with 2 Outputs MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

Entryphone. PinNet 4. Product manual. October 2010 R Granville Road, London SW18 5SD

GV-AS Controller. Installation Guide

B100-SA Standalone Biometric Reader

ACCESS CONTROL SYSTEM

Transcription:

FTK5 PROXIMITY KEYPAD Before using the unit, please read the instructions and retain for future reference 1

There are 600 user codes (fobs or cards) and 1 programming code: Careful administration records will be required for future reference, please refer to last page of the instructions for an example sheet. Important Note: If a code is required then this has to be programmed with a fob or card To add fob or card Enter programming code: i.e. 1 2 3 4, 1 2 3 4 (default unless changed) Long beep, Yellow LED Enter user ID from 001-600: i.e. 002 (alternating flashing green/amber) if you hear a double bleep and constant green LED then the user ID has already been programmed and will require deleting first before programming Then: Swipe card/fob (single beep alternating flashing green/amber) You can then swipe the next card or fob for the next consecutive User ID will be used. To exit programming mode press: # To add fob/card and user code Enter user ID from 001-600 i.e: 0 0 2 (alternating flashing green/amber) if you hear a double bleep and constant green LED then the user ID has already been programmed and will require deleting first before programming Enter user code: X X X X - (X=Code) (double beep) then Swipe card/fob (beep) You can then insert the next user code and swipe fob for the next consecutive User ID will be used. To exit programming mode press: # Access Modes: The keypad can operate in a choice one of 3 modes (default = 0) 0: Either Fob/Card or code 1: Card only 2: Card/Fob & code required Enter programming code (default 1234): 1 2 3 4, 1 2 3 4 (unless changed) Enter: 8 1 0 M # (M = above modes 0, 1, 2) Note: If a button is not pressed within 30 second the keypad will exit the programming menu Careful administration records will be required for future reference, please refer to last page of the instructions for example sheet 2

To Change the Lock Output Time (Default 5 Seconds) Enter: 8 2 0 T T # (T T equals time in seconds i.e. 08 for 8 seconds) To Delete User ID fob/card and user code Either To Delete All Users, Enter: 8 5 0 1 0 0 0 # To Delete Individual Users: 8 5 0 1 X X X # - (X = User ID) To Delete Consecutive Users: 8 5 0 2 S S S E E E # (i.e. to delete User ID 015-023), example enter: 8 2 015 023 # to delete card numbers for 15-23 (X = User ID) To Change the Programming Code (engineers Code) This code will only allow access to the programming menu functions and will not operate the lock output Enter: 0 0 0 (double bleep, constant amber LED) Enter New Programming code: X X X X # To Insert a Programming Card/Fob (This Card/Fob will not operate the Lock) This card/fob will only allow access to the programming menu functions and will not operate the lock output Enter: 8 8 8 (double bleep, constant amber LED) Then Swipe card/fob (beep) BACKLIGHT MODE Backlit Mode Description 0 Disabled No backlit Light - only illuminates on key press 1 Enable Always On 2 Automatic + Timer Back light illuminates when a key pressed or fob/card and remains illuminated for 10 seconds after the last key press From quiescent state: Constant Blue LED (default = 1) Enter: 8 5 9 X # - (X = Backlit Mode) To programme AUX Code The AUX Code operates the AUX Output (no default code) Enter: 840 X X X X # - (X = AUX Code) Swipe Card/fob if required 3

Keypad Lock Out Incorrect Code Entry Option to lock the keypad for 30 seconds on 4 incorrect code entries only, when the keypad is in the lock mode the proximity sensor is also disabled Enter: 8 5 1 # Repeat above process to toggle on or off Change Incorrect Code Input Mode (Default 1) Option for inputting of codes 20 Digit = 0: You can enter up to 20 digits to enter the code without an error tone Code Set = 1: You can only enter 4 digits before an error tone (if programmed for 4 number code) Enter: 8 5 3 0 # - For 20 consecutively digit number entry before error tone Enter: 8 5 3 1 # - For Code Set, 4 digit number entry before error tone if incorrect code entered & depending on code length Change Toggle Code Toggle code once entered will permanently override the lock until the Toggle code has been re-entered (i.e. for deliveries). Note: For the toggle code to operate the Toggle Mode will need to be set. This mode NOT suitable for failsecure locks. Enter: 8 5 4 X X X X # - (X = Bypass Code) Change Toggle Mode (default = normal mode) Option required if Toggle Code is required, when the Toggle Code has been entered the lock will operate and remain unlocked until the Toggle Code has been re-entered Enter: 8 5 2 0 # - Normal Mode Enter: 8 5 2 1 # - Bypass Mode ALARM OUTPUT MODE Alarm Output Mode Description 0 Disabled Alarm Output Inactive 1 Door Contact 1) Alarm output will activate if the door contact is open 2 Tamper Alarm output will activate on tamper activation 3 1 or 2 Either Mode 1 or 2 will activate the alarm Output Enter: 8 5 5 X # - (X = Above Alarm Output Module) 4

To Change Alarm Output Time (Default 030 Seconds) When the alarm output is activated the keypad tone will also sound, an active fob or code will be required to reset the keypad Enter: 8 5 6 T T T # (T T T equals time in seconds i.e. 008 for 8 seconds) AUX OUTPUT MODE In mode 5, you trigger AUX but detecting Reed, if Reed is triggered without a correct password or PB. AUX Output Mode Description 0 Disabled Aux Output Inactive 1 Incorrect Code Operates AUX Output from incorrect code or fob entry Incorrect Code or fob entry (dependant on section 2 Password Error ¹ Change Code Input Mode) 3 Press the or the ¹ This feature could be used as doorbell button which operates AUX Output 4 Tamper activated ¹ Operates the AUX output 5 Door forced ¹ Door opened (reed activation) with correct code/fob or push button activation 6 Activate P.B.¹ Operates AUX Output when the push button has been operated 7 AUX Code AUX code entered activates output ¹ If the AUX output time is left at 000 then operation will not work AUX Output Mode (See table above) Enter: 8 5 7 X # - (X = Above Aux Output Mode) To Change the AUX Output Time (Default 000 Seconds) Enter: 8 5 8 T T T # (T T T equals time in seconds i.e. 008 for 8 seconds) FACTORY RESET or SYSTEM RESTORE Remove Power to the keypad Insert the jumper on the printed circuit board marked as SYSTEM RESTORE Restore Power, wait 5 seconds then remove the shorting jumper pin 5

1 Gang Box 6

Wiring Diagram Magnetic Lock (Failsafe) Varistor Wiring Diagram DLU1 Lock (Failsecure) If door contact or reed switch is not used then ensure the Reed jumper is inserted 12/24v AC/DC AL O/P(-) (-) COM REED P.B. NC C NO Lock Output NC C NO AUX Output 12V DC PSU + - DLU1 Failsecure Lock 230V SUPPLY 7

Fob or Card ID Number Keypad User Number Named Holder Example: 0214561967 028 Mrs J Smith 000 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 034 035 036 037 038 039 040 041 042 043 044 045 046 047 For Additional fobs please use blank sheet on following page 8

Fob or Card ID Number Keypad User Number Named Holder 9

Quick Reference Table Function Programming Code Factory Default Changed Notes Change Master Password 0 0 0 1 2 3 4 Setup User Password or Fob 001 600 0 0 1 = 3 3 3 3 Access Mode 8 1 0 0 = Card or Code Lock Output time 8 2 0 5 Seconds Set AUX Password 8 4 0 None Delete User 8 5 0 Keypad Lockout (incorrect entry) 8 5 1 Off Toggle Mode 8 5 2 0 = Normal Mode Incorrect Code Input Mode 8 5 3 0 = 20 key presses Change Toggle Code 8 5 4 None Alarm Output Mode 8 5 5 0 = Disabled Alarm Output Time 8 5 6 0 3 0 = 30 Secs Change AUX Output Mode 8 5 7 7 = AUX Password Change AUX Output Time 8 5 8 0 0 0 = On/Off Backlight 8 5 9 1 = Open 8 8 8 None Specification 26Bit (card) 26 / 34Bit Power : AC/DC 12~24V +/-10% Power consumption: 3W Lock Out: volt free change over contacts Max 24v 3A Aux Out: volt free change over contacts Max 24v 3A AL Out (Alarm): Sw- output Max 12v 500mA Weight: 0.56kg Size: 79 (W) x 79 (H) x 28 (D) Card: EM induction card (125 KHz) Due to our policy of continuous improvement we reserve the right to change specification without prior notice. Errors and omissions excepted. These instructions have been carefully checked prior to publication. However, no responsibility can be accepted by Challenger Security Products for any misinterpretation of these instructions. Distributed by: CHALLENGER SECURITY PRODUCTS 10 Sandersons Way, Blackpool, FY4 4NB Technical helpline: 01253 792898 Email enquiries.challenger@adivision.co.uk Website: www.challenger.co.uk 10