(Cat. No A1B, -A2B, -A3B, -A3B1, -A4B Series B) Installation Data. Make sure you have these items:

Similar documents
Installation Instructions

Installation Instructions

Installation Instructions

Digital ac/dc (24V) Input Module

Installation Instructions

Installation Instructions

Installation Instructions

Allen-Bradley Drives

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

ISOLATION RELAY RACK ISOLATION KIT 19 RACK MOUNT RELAY RACK ISOLATION KIT, SLOTTED UNEQUAL FLANGE RACK ISOLATION KIT 23 RACK MOUNT

PACSystems RX7i IC698CHS009/119

Installation Instructions

Installation Instructions

Series 3700 Screw Terminal Assemblies Installation Instructions

RMB-3 Peripheral Unit. Installation Guide INSTALLATION GUIDE WESTELL.COM. Westell Technologies Part # Rev. A

PLC Racks IC697CHS782/783

Power Supply Chassis

Replacing the Power Supply

Assembly and Installation Manual. AB PLCs

In this section we tell you how to initially handle your module, key your I/O chassis, install your module and make your wiring connections.

1. Carefully unpack the um260 s shipping carton and check the contents for damage.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT.

IBM. Rack Installation Instructions

Rack Installation Instructions

Remote RMM-1400 Intelligent Remote Site Management Device. Installation Guide

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

24 Input/8 Output AC Block I/O Module

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

256 Kbytes (1771-DRS) 1 Mbyte (1771-DRS1) 4 Mbytes (1771-DRS4) Installation Data

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

TRC-190 User s Manual

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions

INSTRUCTION MANUAL RA 59 RACK ADAPTER. 1) This manual is valid for the following Model and associated serial numbers: MODEL SERIAL NO. REV. NO.

Installing the Cisco SFS 3504 Server Switch

A-100G6 - Basic frame assembly diagram

13 MMC for PC Option Modules

This Datasheet is for the IC693CBL300. I/O Bus Expansion Cables.

This Datasheet for the IC660BBA101. Block 115Vac/125Vdc RTD Input 6 Channels.

Junos WebApp Secure 5.0 Hardware Guide

TCNM-ACBB1 Installation Manual

Hardware Installation. In this chapter... Custom Labels EMI Noise Filter Installation Mounting DIN Clip Mounting Connections and Wiring

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication

Assembly and Setup Manual

IC693 PLC IC693ACC350, IC693ACC340/341

CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.

Read this chapter to familiarize yourself with this manual. It tells you how to use the manual properly and efficiently.

RMB Peripheral Units Installation Guide

Site Preparation CHAPTER

Installation Instructions

SUN KTL-USH0 Quick Guide. Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

The information in this chapter will enable you to: Understand the product's basic functions & features

Throughout this manual we use notes to make you aware of safety considerations:

Installation and Maintenance

TDM To MiniMech conversion ProceDure

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

You cannot install the module unless the connector is fully extended. ATTENTION: Allen-Bradley HMIs

Installation and Environmental Considerations For Kinco Motion Control Systems

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

and Network Interface Modules Installation Instructions

Hardware Installation. In this chapter... Custom Labels EMI Noise Filter Installation Mounting DIN Clip Mounting Connections and Wiring

Allen-Bradley. User Manual. ControlNet Adapter Module. (Cat. No ACN and -ACNR Series B)

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Control Box Setup - PRSalpha

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

efesotomasyon.com - Allen Bradley,Rockwell,plc,servo,drive

Attention statements help you to: identify a hazard avoid the hazard recognize the consequences

Type DH7091 Transient Protection Assembly

Dell Storage MD1400 Enclosures Hardware Owner's Manual

Kramer Electronics, Ltd. USER MANUAL. Model: WP-101. XGA/Stereo Audio Line Driver

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

AI130 AIswitch Series 130 Chassis Installation Guide

HX WCS Indoor DAS Remote Unit Quick Installation Sheet

TRC-190 User s Manual

(Cat. No P1) Installation Data

XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

PV Rapid Shutdown device

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

Installing the DX LCD Display

GF92 Installation, Operation and Troubleshooting Guide

PowerLogic High Density Metering System 1-Meter Enclosure

SM Sygnus Hybrid Quick Installation Guide Version

Sure Coat Modular Gun Control System Part C: UCS ProfiBus Interface Card. Customer Product Manual Part B

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

HD22 and HD30 Service Parts

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

OPLC Installation Guide

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

Throughout this manual we use notes to make you aware of safety considerations:

Installation Job Aid for VSP 4450GTX-HT- PWR+

Open Processor with Square D Driver

Transcription:

(Cat. No. 1771-A1B, -A2B, -A3B, -A3B1, -A4B Series B) Installation Data Make sure you have these items:

Important: Make sure you meet these minimum spacing requirements. 2

3

4

Each enclosure must contain a central ground bus. The ground bus is the common connection for each chassis within the enclosure and the enclosure itself. Use either bolts or welded studs to mount the I/O chassis and central ground bus. If you are mounting a chassis to the back panel of an enclosure, use 1/4-20 (M6 x 10) mounting bolts. ATTENTION: If the mounting brackets of a chassis do not lay flat before the nuts are tightened, use additional washers as shims so that the chassis will not be warped by tightening the nuts. Warping a chassis could damage the backplane and cause poor connections. 5

19938 6

Important: Use the following information, along with the installation manual for your programmable controller to ground the I/O chassis and your I/O modules. 7

Connect an equipment grounding conductor directly from each chassis to an individual bolt on the ground bus. If the power supply has its own groundable chassis, do not connect the GND terminal of the power supply. However, when you connect power to a power supply without a groundable chassis (such as an ac input power-supply module), you must also use 14 AWG copper wire to connect its GND terminal to the ground stud or mounting bolt connected to the ground bus. 8

The grounding-electrode system is at earth-ground potential and is the central ground for all electrical equipment and ac power within any facility. Use a grounding-electrode conductor to connect the ground bus to the grounding-electrode system. Use at minimum 8 AWG copper wire for the grounding-electrode conductor to guard against EMI. The National Electrical Code specifies safety requirements for the grounding-electrode conductor. Certain connections require shielded cables to help reduce the effects of electrical noise coupling. Ground each shield at one end only. A shield grounded at both ends forms a ground loop which could cause faulty PLC-5 processor operation. Ground each shield at the end specified in the appropriate publication for the product. Avoid breaking shields at junction boxes. Many types of connectors for shielded conductors are available from various manufacturers. If you do break a shield at a junction box: connect only category-2 conductors in the junction box do not strip the shield back any further than necessary to make a connection connect the shields of the two cable segments to ensure continuity along the entire length of the cable For more information about grounding the chassis, see Programmable Controller Wiring and Grounding Guidelines (publication 1770-4.1). 9

Set the power supply configuration jumper according to the power supply you are using. ATTENTION: If you do not properly configure the power supply configuration jumper, the processor will fail. Important: You cannot power a single I/O chassis with both a power-supply module and an external power supply. Use the installation manual for your programmable controller or adapter module to set the switches. ATTENTION: If you do not properly configure the backplane switch assembly, various system failures may occur. 10

Your I/O chassis can receive power through: processors with integral power supplies that provide 2-4A power-supply modules that provide 3-8A external power supplies that provide 6.5-16A (external power supplies are not designed for parallel operation) Power-supply modules are designed for parallel operation. See your power supply installation documentation for possible configurations. Important: The 1772-LSP, -LWP, -LXP, and -LZP processor modules already contain a power supply so you can only parallel one additional power-supply module with these processor modules. ATTENTION: Do not connect an external power supply and a power-supply module to the same I/O chassis; they are incompatible. The I/O chassis has two power connectors. You connect the external power supply or power supply chassis (1771-PSC) to the I/O chassis using these connectors and the appropriate power supply cables. Important: Use the installation data for your power supply or power supply chassis to properly mount it to your I/O chassis. ÓÔÔ ÔÔ ÑÓÔÔ ÔÔ 11

The left-most slot of each chassis accepts either a processor module or an I/O adapter module. The other slots in the chassis accept communication modules, I/0 modules and power-supply modules. To insert a module: 1. Pull the locking-bar pins to release the locking bar and swing it up. 2. Use the installation data/user manual for your module to: a. position the keying bands in the backplane connectors to correspond to the key slots on the module. This prevents you from inserting the wrong module in this slot. ATTENTION: Observe the following precautions when inserting or removing keys: insert or remove keys with your fingers make sure that key placement is correct Incorrect keying or the use of a tool can result in damage to the backplane connector and possible system faults. b. install the module. Important: Firmly press the module into the chassis backplane connector. The chassis locking bar will not close if any modules are not seated properly. 12

3. Swing the chassis locking bar down into place to secure the modules. Make sure the locking pins engage. 4. Apply the I/O group labels over the scored lines on the I/O chassis locking bar as shown below. On each label, record the I/O rack number, I/O group number and terminal numbering for each module. 5. Use your module s installation data to make other wiring connections. 6. Apply power to the system and run tests as required. 13

y 14

15

16