OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

Similar documents
Prisma II Platform. Optoelectronics

Junos WebApp Secure 5.0 Hardware Guide

EOS-6000 Series Optical A/B Switch User Manual DC Version

ChromaFlex Chassis. Hardware Interface Manual

Installing the Cisco MDS 9020 Fabric Switch

NI PXIe-1062Q Power Supply Shuttle

Cisco Prisma II Platform

TRC-190 User s Manual

Perle MCR200 Installation Guide

Replacing the Power Supply

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

Dell SC7020 Storage Controller Getting Started Guide

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

TABLE OF CONTENTS 1. OVERVIEW... 1

Technical Manual SMART TRAC PS Card

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

OTEB-CO-P PRE-AMP EDFA INSTRUCTION MANUAL

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

PT-7728/7828 Quick Installation Guide

NI PXI-1042 Series Power Supply Shuttle

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Replacement Instructions. Backplane PCA for the HP Router 650

1. Unpacking the System

Dell Networking S4810 Open Networking (ON) Getting Started Guide

MPP1700 User s Manual

OTEB-CO-B Series. Booster EDFA OPERATING MANUAL

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

EMC1600 Series Media Converter and Ethernet Extender Chassis

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

Installing the Cisco SFS 3504 Server Switch

Installation Job Aid for Ethernet Routing Switch 5900 Series

imaging Series Quartet Guide to Installation and Operation M

MIC Advantech CompactPCI. Modular Industrial Computer. 10U high 8-slot enclosure with CT bus and rear I/O for CompactPCI backplane

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

DMC-1000 Chassis-Based Media Converter

TRC-190 User s Manual

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual

Installation and Maintenance

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

AI130 AIswitch Series 130 Chassis Installation Guide

HP ProLiant DL165 G7 Server

Installation Job Aid for Ethernet Routing Switch 3600 Series

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

LASER PLUS OPERATING INSTRUCTIONS

Storage/Control I/O Module

Chassis Overview. About the Cisco NCS 4016 Chassis. This chapter provides an overview of the Cisco NCS 4016 chassis and components.

Analog Monitor Installation Manual

NT1B-300 Rack Installation Instructions

AI180I AIswitch Series 180 Integrated Chassis Installation Guide

Summit Virtual Chassis Design and Installation Guide

PEM Faults and Blower Failures

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

iconverter 2-Module Power Chassis

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Rack Installation Instructions

Power Supply and Fan Module Installation

Remote RMM-1400 Intelligent Remote Site Management Device. Installation Guide

Enclosure TS-530 User Manual

Dell Networking S4100-ON Series. Set-Up Guide

TN-5308 Quick Installation Guide

IKS-G6524A/G6824A Series Quick Installation Guide

MONITORING INTELLIRACK USER MANUAL

EL1142 Series. IEC / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter. User s Guide

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Dell MD1280 Storage Enclosure Getting Started Guide

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

IMC-21 Quick Installation Guide

2201 Rack Chassis User Manual

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

OV-MCR116. Media Converter Chassis System. User s Manual

28-Position 23 Rack Mounting Model RM23-20X

Xpander Rack Mount 16 5U Gen 3 with Redundant Power [Part # XPRMG3-1625URP] User Guide

PTC-101 Quick Installation Guide

S5048F-ON. Set-up Guide

Rack Installation Instructions

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

E-Series Site Preparation Guide

INJ-24A Series Quick Installation Guide

Maintaining E-Series Routers

Cisco ONS CL Shelf Assembly Hardware

MIC-3001/8. 3U/4U CompactPCI Enclosure for Rack Mounting. User Manual

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

CPCI System Subrack 1 U

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

SATA II HDD Canister KISS DA 435 Quick Reference Guide

PTC-101-M12 Hardware Installation Guide

GOLDENI. Owners Manual & Safety Instructions. English. model# GOLDi600. Copyright 2017 Smart Grow Technologies, INC All Rights Reserved

Dell SC460 Expansion Enclosure Getting Started Guide

imediachassis Series imediachassis/20 imediachassis/6 imediachassis/3 Operation Manual

S4112-ON Series. Setup Guide

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Transcription:

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-CH Rev. X1 E-Mail: salessupport@olsontech.com www.olsontech.com 10/7/2010

PRECAUTIONS Failure to comply with these general safety precautions and with the specific precautions described elsewhere in this manual violates the safety standards of the design, manufacture, and intended use of the device. Olson Technology Inc. assumes no liability for the customer s failure to comply with these precautions. CAUTION: Ensure that the voltage visible through the Line Voltage Indicator window on the AC power entry port of the power supply module corresponds to the range in the specifications (85 to 264 V ). AC CAUTION: Do not operate the chassis or power supply outside of their maximum ratings. Doing so may result in unsatisfactory performance, unit failure, shortened unit life span, or a safety hazard. CAUTION: Do not attempt to modify or service any part of this chassis not specifically referred to as replaceable in this manual. Doing so voids the warranty. Return the chassis to Olson Technology Inc. for service and repair. CAUTION: No chassis should be operated in an ambient environment above 50ºC (122ºF). CAUTION: Do not restrict airflow in front or back of the chassis. The OTOHP-PS power supply module should be operated in an ambient environment between 0 and 50ºC (32 and 122ºF) for a continuous output of 200 watts. CAUTION: Store the chassis and power supply module away from corrosive materials, at a temperature between -40 and +70ºC (-40 to +158ºF), and with no more than 85% humidity, non-condensing.

INTRODUCTION The Olson Technology, Inc. Model OTOHP-CH is a standard 19-inch width, 3RU high chassis that is the heart of Olson Technology s OHP (Optical Headend Platform) system. The chassis is 3RU high and has seventeen(17) slots to accommodate all module types. The chassis will hold up to fifteen (15) modules and one (1) OTOHP-PS power supply or thirteen (13) modules and two redundant power supplies. A backplane interface provides inter-module communication and power distribution. OTOHP-BP blank panels can be ordered to cover the slots not being used by a module. The OTOHP-PS power supply module provides stable powering for all modules in the chassis. The auto-recovery short circuit protection function of the power supply improves the reliability of the platform. On the front panel, LED s indicate the module status and health and DC voltage output status. OTOHP-PS also provides a +24VDC test point voltage testing for output. POWER SUPPLY ELECTRICAL & ENVIRONMENTAL CHARACTERISTICS Min Typ Max Units Input AC Voltage 85 264 V AC Output DC Voltage 24 V DC Output Pwr. Capability 300 W Efficiency 1 86 % Efficiency 2 84 % Operating Temp. Range 0 +50 C Storage Temp. Range -40 +70 C Relative Humidity 3 5 85 % Weight 2 kg 4.4 lbs. Input Connector IEC Male Short Circuit Protection Yes Dimensions 395 x 48 x 128 mm 15.6 x 1.89 x 5.04 in. NOTES 1) 230V AC - Full Loading 2) 115V AC - Full Loading 3) Non-condensing

INSTALLATION / ENVIRONMENTAL CONSIDERATIONS CAUTION: Two people are required to install the chassis. Due to the weight of a loaded chassis, the chassis should be installed without modules. The chassis is designed to be installed into a standard EIA 19 inch rack in an indoor environment following the guidelines below. 1. Do not block the front or back panel of any chassis and maintain sufficient space in front of and behind the rack for air circulation. 2. Align the mounting holes in each of the front flanges of the chassis with holes in the rack. 3. Install and tighten all four mounting flange screws securely. 4. If one or two OTOHP-PS power supply modules will be installed in the chassis, verify that the voltage visible through the Line Voltage Indicator window on the AC power entry port of the p o w e r s u p p l y m o d u l e corresponds to the range in the specification sheet (85 to 264 V ). AC 5. Install the power supply module(s) into the chassis. The OTOHP-PS power supply module is a dual-width module requiring two adjacent slots (slot 1 can only be used for OTOHP- NMS installation). 6. Set the power switch on the Standard 19" Rack OTOHP-CH 3RU Chassis w/ OTOHP Modules front of the power supply module to the ON position. The power indicator should light and the eight (8) cooling fans located on the rear panel of the chassis should run, indicating proper operation of the chassis. 7. Install all the appropriate modules into the chassis.

OPERATION PANEL DESCRIPTIONS The components and features of the chassis and power supply are described below. 3 7 5 6 8 1 9 2 4 1. Handle: For handling the chassis when installing or uninstalling from the rack. 2. Mounting hole (four locations): Fixes the chassis to the standard rack. 3. Chassis backplane: Provides signal and power connections to modules. 4. Slot: Guide for application module installation. 5. Fan: For heat dissipation. 6. Grounding Screw: For chassis grounding. 7. ID Selector: Select chassis ID for cascade application. 8. Grounding Screw: For chassis grounding. 9. RS-485 Port: Provide connect port for cascade application. 10 11 1 2 3 4 5 6 12 7 8 9 1. STA LED: Green indicates the module is operating properly. Red indicates the module has alarms. 2. DC Out LED: Green indicates the module is putting out DC power. If the LED is dark, the power supply is not putting out DC power.

OPERATION PANEL DESCRIPTIONS (CONT.) 3. TP/24VDC: Anode for 24V DC out test point. 4. GND: Ground for 24V DC out test point. 5. Handle: Used to handle the module when being installed or uninstalled. 6. Heat dissipation hole: Air flow out of holes dissipates heat from the module. 7. Power switch: Turns the power supply module on and off. 8. Thumbscrew: Fixes the power supply module to the chassis. 9. Thumbscrew: Fixes the power supply module to the chassis. 10. 30-pin Connector: Provides power and signals to the chassis backplane; connector type is male. 11. 30-pin Connector: Provides power and signals to the chassis backplane; connector type is male. 12. IEC Male Plug: Provides input of AC power to the power supply. UNPACKING AND CHECKING All units are tested and inspected before shipment and found to be free of mechanical and electrical defects. However, upon receiving your products. 1. Examine all shipping containers for any damage caused by shipping. 2. Unpack all modules and chassis. 3. Keep all packing materials until your inspection is complete. When possible, save the shipping container for future reshipment and/or storage. If damage is discovered, file a claim with the carrier immediately and notify your Olson Technology, Inc. representative as soon as possible. Products deemed defective by the original purchaser must be returned to Olson Technology, Inc. prepaid in the original packing material (or equivalent) with a Return Material Authorization (RMA) from the Olson Technology, Inc. INSTALLING MODULES If only a single power supply module is to be installed in the chassis, refer to the section above for powering considerations. CAUTION: Some components are sensitive to electrostatic discharge (ESD)! Use a grounding strap to prevent damage to electronic components by ESD. Do not touch any components not specifically referred to in these instructions.

INSTALLING MODULES (CONT.) CAUTION: Some module pins are sensitive to electrostatic discharge (ESD)! Use a grounding strap to prevent damage to the module by ESD. CAUTION: Installing a module with bent pins will damage the backplane connector pins on the module and may damage the mating chassis backplane connector. CAUTION: If the OTOHP-NMS module is used, it should be installed in Slot 1 only. Note: Modules can be installed and removed with the chassis powered. A power supply module can also be placed in two adjacent slots. Tip: It may be beneficial to install, connect, and configure one module at a time. Also, installing similar type modules (i.e. Forward Transmitters or Return Receivers) in groups can make the process easier because you will be dealing with the same types of connections and configurations. 1. Inspect for bent pins on the backplane connector at the rear of the module. Straighten any bent pins before installing the module. 2. Gently insert each module into a slot in the front of the chassis. Be careful to align the metal guide rails on the top and bottom of the module with the nylon guides in the interior of the chassis housing. 3. Tighten the thumbscrew on the front of the module. 4. Repeat Steps 1 through 3 to install the remaining modules in the chassis. 5. On the power supply module(s) plug the power cord (shipped with the power supply module) into the IEC male receptacle and turn the power switch to the ON position. The module will start to work. 6. The application modules available for installation in the OTOHP-CH chassis are listed below. Module Forward Path 1310nm Tx Forward Rx w/ Redundant Inputs QAM 1550nm DM Tx (future) Quad RFoG Return Path Rx Quad Reverse Return Path Rx EDFA (future) Network Management System Blank Panel for Unused Chassis Slot Part Number OTOHP-FTX OTOHP-FRX OTOHP-FTX5 OTOHP-RFG OTOHP-RRX OTOHP-EDFA OTOHP-NMS OTOHP-BP

UNINSTALL THE POWER SUPPLY MODULE Note: A service outage will occur if a power Supply module is removed from a chassis if no other power supply module is installed in the chassis. 1. Turn the Power Supply module off. 2. Disconnect the power cord from the power supply module receptacle at the rear of the OTOHP-CH chassis. 3. Loosen the two thumbscrews on the front panel of the module. CAUTION: Do not pull on the thumbscrews to remove the module. Pull on the handle that the thumbscrew goes through to remove the module. STATUS LED LIGHT RED TROUBLESHOOTING 1. Check to verify that fans are running on back panel. 2. Check DC test point output voltage (spec. 24V DC 1.8V). If module has any one condition, please call customer service department. DC OUT LED NOT LIT Installation of the AC Power Supply module is explained above. Periodically verify that the DC OUT LED on the front panel of the Power Supply module(s) is lit. If this LED is not green, please check DC test point on front panel. There is a fault on a power supply module, or a short circuit in one of the modules installed in the chassis.