H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Similar documents
HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

GENERAL PRECAUTIONS GENERAL DESCRIPTION... 6

ELV12 Series. Instruction Manual

Conductive Level Controller

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E

EX-RC1 Remote I/O Adapter

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

CUS150M1 Instruction Manual

EX-RC1 Remote I/O Adapter

TOUCH SCREEN CONTROLLER for Air Conditioning Control System

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

ERNT-AQTX10 ERNT-AQT68AD-GH. User s Manual. Mitsubishi General-Purpose Programmable Logic Controller Renewal Tool Conversion Adapter.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

V E1B Snap-in I/O Module

V E2B Snap-in I/O Module

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Component identification

DC I/O Conversion Module FA-TB32XY

EX-RC1 Remote I/O Adapter

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

User safety and equipment protection guidelines

Analog Input/Output Modules

DC I/O Conversion Module

Model 7705 Control Module

F1000 User's Manual. (Version: V1.01)

Communication & Networking

PIEZO FEEDER CONTROLLER

TM3TI4 module TM3-4 inputs temperature

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Package Contents. GP Options (Made by Digital)

V E1B Snap-in I/O Module

Analog Input Installation Manual

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

Analog Input Modules

V E5B Snap-in I/O Module

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

Analog Monitor Installation Manual

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

E2K-X4ME1 2M E2K-X4ME2 2M

Optional add-on cassette Attachment Instruction manual

DANGER. Risk of fire, electric shock, and injury. DO NOT insert or drop any object in openings, this could cause unit failure or

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

C200H-LK401/C500-LK009-V1 PC Link

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

User Manual Digital Input Module

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

IO-LC1, IO-LC3 I/O Expansion Modules 1-3 Loadcell Inputs, 1 Digital In, 2 Out

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

Twido Programmable Controllers Discrete I/O Modules

COMMUNICATION CONVERTER FOR PROFIBUS

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Making Hazardous Operations Safe and Productive

PRO-1250D CT MID DIN rail three phase four wire energy meter.

Programmable Controller Analog Terminal Block Conversion Module FA1-TBS40ADGN, FA1-TBS40ADDG, FA1-TBS40DAG User's Manual

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

USER MANUAL. WBI414F21 AC current transducer

HV-CS kv Edge Mount Triaxial Jack

NX70/NX700 Series Analog Modules (A/D, D/A, RTD, TC) User Manual

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Installation, Operation and Maintenance Manual

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

V E62B Snap-in I/O Module

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

PC-HELPER. Expansion Adapter for Express Card Slot EAD-CE-EC. User s Manual CONTEC CO.,LTD.

TM3TM3 module TM3-2 temperature inputs and 1 analog output

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

USER MANUAL. WBI412F41 AC current transducer

User s Manual. PCI Bus Expansion Adapter for PCI Bus PC-Slot EAD(PCI)BE PCI Bus Expansion Adapter for Low Profile PCI PC-Slot EAD(LPCI)BE

TM3TI4 module TM3-4 inputs temperature

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Model Number Structure

PI-EX-ME-2NAM/COC-24VDC

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

High Speed Remote I/O Module

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

MELSEC iq-r Analog-Digital Converter Module User's Manual (Startup) -R60AD4 -R60ADV8 -R60ADI8

PLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10)

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

1-36V, 0-3A DC Power Supply

MODEL: R2K-1 SEN TRONIC AG. R2K Series

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

TM3AI4 module TM3-4 analog inputs

JANOME DESKTOP ROBOT JR2000N Series. Operation Manual. <Setup> For Qualified Installer ONLY

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

Operating instructions. Switching amplifier DN0210 DN / / 2015

Transcription:

H Series PLC EH-150 Analog input module EH-AXH8M Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction manual and all the user manuals carefully. Please be sure to use the latest versions of user manuals and keep them at hand of end users for future reference. Caution 1. All rights reserved. 2. The content of this manual may be changed without notice. 3. While efforts have been made on this manual to be accurate, please contact us if any mistakes or unclear part is found. Safety precautions Definitions and Symbols!! DANGER CAUTION : Indicates prohibition! : Indicates Compulsion Indicates a potentially hazardous situation which, if not avoided, can result in serious injury or death. Indicates a potentially hazardous situation which, if not avoided, can result in minor to moderate injury, or serious damage of product. Warranty period and coverage The warranty period is either 18 months after manufacturing date (MFG No) or 12 months after installation. Examination and repair within the warranty period is covered. However within the warranty period, the warranty will be void if the fault is due to; (1) Incorrect use from instructed in this manual and the application manual. (2) Malfunction or failure of external other devices than this unit. (3) Attempted repair by unauthorized personnel. (4) Natural disasters. The warranty is for the PLC only, any damage caused to third party equipment by malfunction of the PLC is not covered by the warranty. Repair Any examination or repair after the warranty period is not covered. And within the warranty period any repair and examination which results in information showing the fault was caused by any of the items mentioned above, the repair and examination cost are not covered. If you have any questions regarding the warranty or repair cost, please contact your supplier or the local Hitachi Distributor. (Depending on failure part, repair might be impossible.) Ordering spare parts and inquiries Please contact your local suppliers for ordering products/spare parts or any inquiries with providing the following information. (1) Product name (2) Manufacturing number (MFG No.) (3) Details of failure DANGER - Do not touch terminals while power ON. There is a danger of electric shock and/or injury. - Be sure to install external safety devices outside of the PLC like emergency stop circuit or interlock circuit. CAUTION - Be sure that the rated voltage matches the power supply voltage of the unit. Otherwise, there is a danger of breakdown and/or injury and/or fire. - Only qualified personnel shall carry out wiring work. Otherwise, there is a danger of breakdown and/or injury and/or fire. COMPULSION - Be sure to ground the unit. Otherwise, there is a danger of electric shock and/or malfunction. PROHIBITION - Do not attempt to modify nor disassemble the unit. There is a danger of breakdown and/or injury and/or fire. Mounting!! - Mount the PLC on a metal plate and install in a cabinet as follows. - Be sure to ground the cabinet and the metal plate, otherwise there is a risk of malfunction. - Install the PLC as described in user manual. - Take appropriate measures when the PLC system installed in locations : Influenced easily due to noise or static electricity or other forms of noise. Under strong electromagnetic field. Close to power supplies. - Be sure to tighten mounting screws, terminal screws and connector screws. - Be sure to check that devices with lock mechanism, such as an expansion cable or terminal blocks, are locked properly. 1 NJI-446(X)

Grounding Metal plate Power Supply AC Earth leakage Breaker Enclosure AC AC Basic Unit CPU Expansion Unit Net filter (Recommended) Grounding Insulation transformer (recommended) Figure 1 Power wiring example Table1 Specifications of the net filter Item Spec. Rated voltage 250 VAC Rated current 5 A Withstand voltage (V) 1500 V (between Terminal and case) Insulation resistance (M ) (500VDC, 1 min., between terminal and case) min. 100 M Attenuation Frequency range Differential mode, more than 40dB 0.5-30 (MHz) Common mode, more than 40dB 0.15-30 Reference : EMC filter ZAC2205-00U (TDK) Power Wiring - Appropriate emergency circuitry, interlock circuitry and similar safety measures should be added to the system. - Appropriate safety measures should be included in the system for unexpected breaking of wire or malsignal caused from instantaneous power failure. - Applied voltage must be in the range specified in the manual. Otherwise, there is a danger of breakdown and/or injury and/or fire. - Install an external earth leakage breakers to avoid short circuit accident. - In case of the following operations, turn off power. Otherwise, there is a danger of breakdown and/or injury and/or fire. Mounting or dismounting CPU and I/O modules. Assembling cabinet or machine including PLC. Wiring. - Install net filter specified in table-1 or similar. The input and output cable of the net filter should be separated as much as possible. Be sure to ground the net filter. - A shielded and insulated transformer is recommended. - The basic and expansion unit should be connected to common power source and powered up together as shown in fig.1. I/O Wiring - Be sure that the input/output voltage matches the specified voltage. Otherwise, there is a danger of breakdown and/or fire. - Use shielded cable for relay outputs module, and connect shields to a functional ground for one side or both sides depending on applications. - Route the AC power line and I/O lines separated as much as possible. Do not route both cables in a same duct. - Route the I/O lines and data lines as close as possible to the grounded surfaces such as cabinet elements, metal bars and cabinets panels. Common precautions - Use proper cable ferrules for terminals. Using improper cable ferrules or connecting bare wires to terminals directly might result in fire. - Do not turn on power, if the unit appears damaged. - Be sure to check all the field wiring before PLC power on. Otherwise, there is a risk of fire. - Do not attempt to disassemble, repair or modify any part of the PLC. - Do not pull on cables or bend cables beyond their natural limit. Otherwise, there is a risk of breaking of wire. - Keep PLC modules in their boxes during storage and transport. - Check carefully your PLC program before operation. Installation environment Avoid the following locations to install the PLC. - Excessive dusts, salty air, or conductive materials (iron powder, etc.) - Direct sunlight. - Temperature less than 0 C or more than 55 C. - Humidity less than 20% or more than 90%. - Dew condensation. - Direct vibration or impact to the unit. - Corrosive, explosive or combustible gases. - Water, chemicals or oil splashing on the PLC. - Close to noise emission devices. Reference Manual Read the following application manual carefully to use the PLC safely and properly. Be sure to keep the latest version. Manual name EH-150 APPLICATION MANUAL Manual No. NJI-281* (X) * : The alphabet between 281 and (X) means version (A,B ). 2 NJI-446(X)

1 Name and function Name and function Type EH-AXH8M 1] Lock button 4] Function switch Weight Dimension (mm) Approx. 150 g 6] LED cover 30 95 2] I/O cover 5] Current/ Voltage switch 100 3] Terminal block No. Name Function Remarks 1] Lock button When dismounting the module from a base unit, press this button and lift up the module. The module can be fixed firmly by a screw (M4, 10 mm (0.39 in.)) 2] I/O cover This is the cover attached to the terminal block 3] Terminal block This is the terminal block for connecting input signals. The terminal block is removable. 4] Function switch To configure input range, enable/disable of input filter and resolution. Refer to 4.Setting switch. 5] Current / voltage switch To configure current or voltage input. 6] LED cover Status of module and input signal indicated. OK LED lights in normal operation. Input LED blinks when input current is less than 2mA in case of 4-22mA range. (Mode 10) Refer to 4.Setting switch. For wire breaking detection Item Description Remarks Operation The module receives input signals from external devices. The CPU module recognizes the status of the loaded module and when it matches the I/O assignment information included in the user program, input information is received according to the contents of the user program. Terminal block The screws for the terminal block are M3 screws. Use a crimp terminal that fits the screw diameter. The maximum thickness of the cable should be only up to 0.75 mm 2. (Use 0.5 mm 2 cable when two crimp terminals are attached to the same terminal.) The recommended crimp terminal is indicated below. 6 (0.24) (Recommended) 6 (0.24) Tighten screw firmly since it may fall off if the screw is loosen. Unit: mm (in.) 3 NJI-446(X)

2 Specification Function specification Model name item Specification EH-AXH8M Input range Voltage input 0 to 10 V DC -10 to 10 V DC (Selected by the switch.) Current input 0 to 22 ma 4 to 22 ma Resolution 0 to 10 V 1 mv or 1/16384 (14 bits) -10 to 10 V 1 mv or 1/16384 (14 bits) (Selected by the switch) 0 to 22 ma 0.002 ma or 1/16384 (14 bits) Conversion time 4 to 22 ma 0.002 ma or 1/16384 (14 bits) 8.9 ms / 8 channels Overall accuracy Voltage input ±0.5 % or less (Full scale) Linearity Current input ±0.8 % or less (Full scale) ±0.1 % or less (Full scale) Input filter Enable Approx. 90 ms (to reach 90% after step input) (Selected by the switch) Disable 18 ms or less (to reach 90% after step input) Input impedance Voltage input Differential 200 kω Isolation Number of input channel Weight Wiring Internal current consumption (5VDC) External power supply Current input Between channel and internal bus Between channels 249 Ω Photo coupler Not isolated Differential voltage input 8 ch. or Current input 8 ch. (selected per 4 ch.) Approx. 0.15 kg Removable terminal block (M3) Max. 70mA 24 V DC (+20 %, -15 %) Approx. 0.04 A (Approx. 0.3 A at power on) Cable Shielded pair cable (Max. 20m) I/O assignment Operational temperature / humidity Storage temperature / humidity X8W 0-55 C / 20-90%RH (no condensation) -10-75 C / 10-90%RH (no condensation) 4 NJI-446(X)

3 Terminal layout and internal circuit Terminal layout Internal circuit No. Signal name 0+ OK 0 1 2 3 4 5 6 7 1] 0 + 2] 1 + 0- V / ma switch A N A L O G I N E H -A X H 8 M 1] 2] 3] 4] 5] 6] 7] 8] 9] 10] 11] 12] 13] 14] 15] 16] 17] 18] 3] 2 + 4] 3 + 5] 4 + 6] 5 + 7] 6 + 8] 7 + 9] 24VDC+ 10] 0-11] 1-12] 2-13] 3-14] 4-15] 5-16] 6-17] 7-1+ 1-7+ 7- Ex. Power supply 24V DC + 24V DC - V / ma switch V / ma switch Power circuit Intenal circuit 18] 24VDC- 5 NJI-446(X)

4 Setting switch Be sure to configure the module before operation without power supplied. Switch setting is not effective while power on. If input range is changed, be sure to set current/voltage switch accordingly. [Black part is factory setting.] Table 4.1 Function switch Switch No. Setting Function 1, 2 1 2 Input range for ch.0 to 3 OFF OFF 0 to 10 V DC ON OFF -10 to 10 V DC OFF ON 0 to 22 ma ON ON 4 to 22 ma 3, 4 3 4 Input range for ch.4 to 7 OFF OFF 0 to 10 V DC ON OFF -10 to 10 V DC OFF ON 0 to 22 ma ON ON 4 to 22 ma 5 5 Intput filter OFF Eable ON Disable 6 6 Resolution mode OFF [Mode 16] Hexa-decimal (1/16384) ON [Mode 10] Decimal (0.001V or 0.002mA) 7 7 For system use OFF Set OFF 8 8 For system use OFF Set OFF Table 4.2 Voltage/current switch Switch No. Setting Function 1 to 8 1 to 4 5 to 8 Current / voltage selecting OFF OFF Ch.0 to 7 : Voltage input ON OFF Ch. 0 to 3 : Current input, Ch.4 to 7 : Voltage input OFF ON Ch. 0 to 3 : Voltage input, Ch.4 to 7 : Current input ON ON Ch.0 to 7 : Current input Function switch Protection sheet Current/voltage switch Protection sheet Put the protection sheet after setting for safety. 6 NJI-446(X)

5 Input conversion 0 to 10V 3FFFH (16383) Mode 16 Mode 10 2710H (10000) 1FFFH ( 8191) 1388H ( 5000) Input Mode 10 Mode 16 10 10000 2710H 16383 3FFFH 5 5000 1388H 8191 1FFFH 0 0 0000H 0 0000H 0 V 5 10 1 bit 1 mv 0.61035 mv 10V 2710H (10000) 1FFFH ( 8191) Mode 10 Mode 16 Mode 10 Mode 16-10 0000H(0) 0 V 10 Input 10 10000 2710H 8191 1FFFH 0 0 0000H 0 0000H -10-10000 D8F0H -8192 E000H 2 s complement E000H ( -8192) D8F0H (-10000) 1 bit 1 mv 1.22070 mv 0 to 22 ma Mode 16 10 Mode 3FFFH (16383) 2AF8H (11000) 1FFFH ( 8191) 157CH ( 5500) Input Mode 10 Mode 16 22mA 11000 2AF8H 16383 3FFFH 20mA 10000 2710H 14894 3A2EH 11mA 5500 157CH 8191 1FFFH 10mA 5000 1388H 7447 1D17H 0mA 0 0000H 0 0000H 0 ma 11 22 1 bit 2 µa 1.34277 µa 4 to 22 ma Mode 16 Mode 10 3FFFH (16383) 2328H ( 9000) 1FFFH ( 8191) 1194H ( 4500) Input Mode 10 Mode 16 22mA 9000 2328H 16383 3FFFH 20mA 8000 1F40H 14563 38E3H 13mA 4500 1194H 8191 1FFFH 10mA 3000 0FA0H 4468 1174H 4mA 0 0000H 0 0000H 0H (0) 0 F830H (-2000) 4 13 22 ma 0mA -2000 F830H 0 0000H 1 bit 2 µa 1.09863 µa 7 NJI-446(X)

6 Caution (1) Input signal out of the range Input signal out of the range is converted to the max. or min. value as follows. Ex. : -11V input for ±10V range. -10000 (Mode 10), E000H (Mode 16) Ex. : 23mA input for 0-22mA range. 11000 (Mode 10), 3FFFH (Mode 16) Ex. : 1mA input for 4-22mA range. -1500 (Mode 10), 0000H (Mode 16) (2) LED indication LED Lighting Blinking off OK Normal operation * Module error. - No power supplied (Contact your local supplier if - Module error it happens frequently.) (Contact your local supplier if it happens frequently.) 0 to 7 - Wire breaking (2mA input or less in case of 4-22mA range (Mode 10) ) Normal operation * OK LED lights without external DC24V. (3) Wiring Since analog signal is very sensitive, be sure to use shielded cable in order to protect from noise, and route the cable apart from other power/signal cables. Be sure to ground the shield at one end basically. But grounding at both ends or no grounding can be more effective depending on system environment. Analog input module Shielded cable (Twisted cable) 0+... 7+ 0-... 7- Sensor Converter Shield Grounding at the one end 8 NJI-446(X)