Andover Continuum. Power Supplies with or without UPS

Similar documents
BACnet. b3867 Terminal Controllers

Andover ContinuumTM Infinet II

BACnet. b3810 Series Local Controllers

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

Andover ContinuumTM. b3850 Series Terminal Controllers

Andover ContinuumTM Infinet II

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

Andover ContinuumTM Infinet II

TAC I/NETTM 1284, 1280, Security Control Unit

ACX Series. Access Controller for Ethernet

using optional EMX 190 expansion modules), and makes access decisions based on its own distributed

The Infinity TCX 865 programmable Infinet terminal controller is a unique, low-cost VAV box

MAJOR VA Power Inverter

Industrial Power Supplies

550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure

lighting control. Each controller switches up to 48 high voltage, 20-amp lighting circuits, using

Industrial Power Supplies

Internet Office UPS System - All-in-one SOHO Solution

TALON Network Manager- 2 & 6 Express

Cardkey S300 Enclosures

is then retained absolutely without interruption.

SmartPro LCD 120V 1500VA 900W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

Installation Instructions for UL Rev A

AVR Series 120V 550VA 300W Ultra-Compact Line-Interactive UPS with USB port

AVR Series 120V 700VA 350W Ultra-Compact Line-Interactive UPS with USB port

Andover ContinuumTM Infinet II

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

AVR Series 120V 700VA 350W Ultra-Compact Line-Interactive UPS with USB port

DIN Rail. user manual Models , & INT /503556/ UM

SmartPro 1.5kVA 1000W Line Interactive Sine Wave UPS, 2U Rack/Tower, LCD, USB, RS232, EPO, 120V

Installation Manual for D244X Series 24-volt Power Supplies

EthernetConnect and IP/Analog Fiber Accessories POWER SUPPLIES, RACK CHASSIS WITH INTERNAL POWER SUPPLY

SmartPro LCD 120V 1200VA 700W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

Keyboard-Line Power Adapter for ServSwitch Family

TAA-Compliant AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port

PS-4100 POWER SUPPLY MANUAL

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

AC5160 SiPass integrated controller kit

SmartPro LCD 120V 1500VA 900W Line-Interactive UPS, AVR, Tower, LCD, USB, 10 Outlets

AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port

Premium Online Series

SmartPro LCD 120V 1300VA 720W Line- Interactive UPS, AVR, Tower, LCD, USB, 8 Outlets

VS Series 120V 600VA 300W Line-Interactive Desktop UPS, Tower, 6 Outlets

SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, USB, DB9 Serial

SmartPro 120V 1kVA 650W Line Interactive Sine Wave UPS, Tower, USB, DB9 Serial

SmartPro 120V 1.05kVA 705W Line-Interactive UPS, Tower, 120V, USB port

OmniSmart 1500VA 2U Rack/Tower Line-Interactive 120V UPS with LCD display and USB port

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

SmartOnline 120V 2.2kVA 1.6kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Slot, USB, DB9 Serial

AVR Series 230V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port, French/Belgian Outlets

SmartPro 120V 1kVA 750W Medical-Grade Line- Interactive Tower UPS with 4 Outlets, Full Isolation, USB, Lithium Battery

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

SmartPro UPS System Intelligent, line-interactive battery backup and network power management

OmniSmart 230V 350VA 225W CE/IEC Medical Grade Line-Interactive UPS with Built-In Isolation Transformer

UPS Series. features: uninterruptible power supply. what great systems are built on.

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out

SmartPro LCD 120V 1500VA 900W Line-Interactive UPS, Extended Run, 2U Rack/Tower, LCD Display, USB, DB9 Serial

SmartPro LCD 120V 50/60Hz 1500VA 900W Line- Interactive UPS, AVR, Tower, LCD, USB, 10 Outlets

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack, USB, DB9 Serial, LCD

SmartPro 1kVA 800W Line Interactive Sine Wave UPS, SNMPWEBCARD option, 1U Rackmount, USB, RS232, EPO, 120V

Smart Pro Rack/Tower UPS Intelligent, line-interactive network power management system

Hardwired Uninterruptible Power Supply

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

Smart-UPS APC Smart-UPS 750VA USB & Serial RM 1U 120V

AVR Series 230V 550VA 300W Ultra-Compact Line-Interactive UPS with USB port, C13 Outlets

SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, SNMPWEBCARD Option, LCD Display, USB, DB9 Serial

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial

DC Outdoor Power Supply/Chargers

SmartOnline V 1kVA 800W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial

Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Product Manual. Surge Protected Metal 7- Port USB 2.0 Hub DIN RAIL Mount Kit NEC Chip

CompactPCI SYSTEM POWER SUPPLIES. CPCI SERIES 150 to 350 Watts, Ac Input with PFC DPCI SERIES 150 to 350 Watts, 48 Vdc Input FEATURES:

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U, Extended Run, Network Card Options, USB, DB9

2U/3U Redundant Power Supply. 400W for IPC-Computer

Note: 1. All products are certified with CE, FC, ROHS. 2. All products are designed and produced by Kasman own engineers and factory. 3.

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack, LCD display, USB, DB9 Serial

SmartPro UPS System Intelligent line interactive medical-grade battery backup and network power management

8-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection

Model #: SU1500RTXL2U

FP-PS-4. Features. Installation

SmartPro LCD 120V 1.5kVA 900W Line-Interactive UPS, AVR, 2U Rack/Tower, LCD Display, USB, DB9 Serial

The quality management system is. Mitsubishi Electric Corporation Kobe Works has been approved to ISO9001:2000.

System Components Guide

SITOP in the SIMATIC Design

SmartPro Tower UPS System Intelligent, line-interactive network power management system

LED Indicator. Class I

MONITORING INTELLIRACK USER MANUAL

SmartPro 120V 2.2kVA 1.6kW Line-Interactive UPS, Tower, Extended Run, Network Card Options, USB, DB9 Serial

The 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN.

Chrome DC-UPS Module 24V 10A / DRU-24V10ACZ

Redundancy unit CP-A RU

SmartPro 120V 3kVA 2.88kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

Installation Manual for D155X Series of 12V Switched Mode Power Supply for Access Control

SYSTIUM MODEL 526EX UATX

Transcription:

Andover Continuum Power Supplies with or without UPS The Andover Continuum TM PS 120/240 AC 50-U, PS 120/240 AC 65-U and PS120/240 AC 85-U power supply modules are designed to provide 24 VDC power for the Andover Continuum NetController II CPU module and its associated Andover Continuum I/O modules. In addition, these models provide full UPS battery backup in the event of an AC line failure.

02 with or without UPS Features The PS 120/240 AC 50-U, AC 65-U, and AC 85-U power supplies are part of the Andover Continuum Ethernetbased intelligent building system. The Andover Continuum system allows you to cost-effectively mix and match DIN rail-mounted CPU, power supply, and various combinations of I/O modules and user interfaces to meet your control and monitoring needs. Product AT A GLANCE Power Supply Modules Provide 24 VDC Power and Battery-Backed UPS Power to Andover Continuum NetController II CPU and I/O Modules Choice of 85 Watt, 65 Watt, or 50 Watt Models Built-in Battery Charger Selection of Programmable Battery Backup Modes via Andover Plain English Programming Non-UPS Models Available for Use as an Extended Power Source -48 VDC Model Available for Telecommunications Use DIN Rail Mounting and Slide-Together Connectors for Easy Installation All the models offer an impressive array of features that reduce or eliminate the impact of power failure. In them, a built-in battery charger provides 15 watts maximum to the battery. The charger s current is limited to prevent overloading the power supply in the event of a shorted or defective battery. Using standard rechargeable lead acid batteries (not included), the 50-U model will provide full UPS operation including all I/O modules for up to 60 minutes at 35 watts power consumption; the 65-U model provides 60 minutes full UPS at 50 watts; the 85-U model provides 30 minutes full UPS at 70 watts. Both allow for full operation of the CPU module only (including modem and network interface) with no I/O power for four hours; or backup of DRAM and real-time clock for 72 hours duration. These backup modes can be selected and controlled through Andover Plain English programming. Maximum charging time of the battery charger is 48 hours using recommended batteries. Two 12V 7.0 AHr sealed rechargeable batteries are required with both models (not included). Extended backup times are available using larger batteries. The UPS circuit provides the Andover Continuum CPU with two status signals indicating the operating condition of the power supply one signal indicates an AC power failure and a change over to UPS mode and the other signal indicates when the battery voltage has reached an unsafe discharge level and will soon shutdown. A disconnect switch removes the battery and prevents further discharge of the battery.

03 with or without UPS Features (continued) A connector located on the bottom of the power supply is provided for an optional Main Power indicator LED. This option is ideal if you mount your Andover Continuum system within a larger control panel or enclosure and wish to verify power to the system from a separate location. Dimensional Drawing The power supply module features a sleek, lightweight casing designed for natural convection cooling. Built-in quick-release fasteners at the back of the module are provided for DIN rail mounting no tools required. These fasteners also snap into a locked position for panel mounting. The power supply is designed for mounting in an optional NEMA 1-style Andover Continuum enclosure. Other Available Models PS 120/240 AC 85 A non-ups version, the PS 120/240 AC 85, is also of a typical Andover Continuum system, even to remote locations. Because there is no built-in battery charger in this model, a full 85 watts of PS 120/240 AC 65 A non-ups version, the PS 120/240 AC 65, is also of a typical Andover Continuum system, even to remote locations. Because there is no built-in battery charger in this model, a full 65 watts of PS 120/240 AC 50 A non-ups version, the PS 120/240 AC 50, is also of a typical Andover Continuum system, even to remote locations. Because there is no built-in battery charger in this model, a full 50 watts of PS 48 DC 50 A PS 48 DC 50 model is available. This model accepts power from 41 to 53 VDC and allows industries such as telecommunications to provide uninterrupted power to critical environmental monitoring and control equipment using their own battery-backed power systems.

04 with or without UPS Specifications Electrical Input Voltages 100 to 240 VAC, 50/60 Hz -41 to -53 VDC (PS 48 DC 50 model only) Output Voltages 24 VDC, ±5% (all models) Output Power Available 70 watts (PS 120/240 AC 85-U model) 85 watts (PS 120/240 AC 85 model) 50 watts (PS 120/240 AC 65-U, PS 120/240 AC 50 and PS -48 DC 50 models) 65 watts (PS 120/240 AC 65 model) 35 watts (PS 120/240 AC 50-U model) Overload Protection Short circuit protection Overvoltage protection Fuse protection on inputs MOV protection on inputs Mechanical Operating Environment 32 to 120 F, (0 to 49 C), 10 to 95%RH (non-condensing) Size 9.0 W (228.7mm) 7.2 H (182.88mm) (with mounting clips extended) 6.2 H (157.48mm) (with mounting clips closed) 2.5 D (96.5 x 170.2 x 63.5mm) Weight 1.75 lbs (0.79kg) Enclosure Type UL open class, flammability rating of UL94-5V, IP 10 Mounting Mount on DIN rail or wall-mount using attached fasteners. Andover Continuum NEMA 1-style enclosure available. Battery Battery Backup Battery backup UPS circuit with built-in battery charger provides automatic battery backup UPS power in event of AC line failure. Two 12V 7.0 AHr sealed rechargeable batteries (not included), connected with 5 amp pico fuse, provide a 24 VDC battery source. Battery Backup Duration 60 minutes @ 35 watts power consumption full UPS to CPU plus I/O power (PS 120/240 AC 50-U model), 60 minutes @ 50 watts power consumption full UPS to CPU plus I/O power (PS 120/240 AC 65-U model) and 30 minutes @ 70 watts (PS 120/240 AC 85-U model); 4 hours CPU module only (including modem and network interface) with no I/O; or 72 hours DRAM and real-time clock. Expandable by use of greater amp hour batteries. For example, for a 4-hour full backup time, minimum of 2-12V 28 AHr batteries must be provided. Battery Charging Time 48 hours maximum for built-in 15 watt battery charger to fully charge battery from lowest system battery discharge point. Connections AC Input 50, PS 120/240 AC 65-U, PS 120/240 AC 65, PS 120/240 AC 85, and PS 120/240 AC 85-U models only) Three-position screw connector DC Input (PS 48 DC 50 model only) Three-position screw connector Battery, 24 VDC Two-position plug-in screw connector External Power Indicator Two-position connector for optional power indicator LED (optional cable assembly available). User LEDs/Switches Status Indicator LEDs MAIN POWER AC (or DC) Power ON/OFF Status Indicator UPS POWER UPS Power ON/OFF Status Indicator

05 with or without UPS Specifications (continued) Switches ON/OFF Turns AC (or DC) power ON and OFF. Located on top left side of module. Indicated by MAIN POWER LED. Agency Listings UL/CUL 916, FCC CLASS A, CE, UL 864 (PS 120/240 AC 65-U and PS 120/240 AC 65 only) UL 294 (PS 120/240 AC 50-U, PS 120/240 AC 50, PS 120/240 AC 65-U, PS 120/240 AC 65, PS 120/240 AC 85-U, PS 120/240 85) UL1076 (PS 120/240 AC 50-U, PS 120/240 AC 65-U and PS 120/240 AC 85-U only) Options External Power Indicator LED Cable Assembly Approximately 2 ft. in length. (P/N: 01-0100-422) Two 12V 7.0 AHr Sealed Rechargeable Batteries Only (P/N: 01-2100-423) Battery Bracket & Cable Only (P/N: 01-0010-868) Two 12V 7.0 AHr Sealed Rechargeable Batteries plus Battery Bracket & Cable (P/N: 01-0010-842) All brand names, trademarks and registered trademarks are the property of their respective owners. Information contained within this document is subject to change without notice. On October 1st, 2009, TAC became the Buildings Business of its parent company Schneider Electric. This document reflects the visual identity of Schneider Electric, however there remains references to TAC as a corporate brand in the body copy. As each document is updated, the body copy will be changed to reflect appropriate corporate brand changes. 2010 Schneider Electric. All rights reserved. May 2010