Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Similar documents
Basketball Shot Clock Set LX2180 Manual

Instruction Manual. Liquitron DP5000 Series ph Controller. For file reference, please record the following data:

SAVE THESE INSTRUCTIONS

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Screw. Nut Guide. Features

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

MAXIMA + Series ROTARY LEVEL CONTROL

Sidewinder Pumps Inc. AC C1D2 Timer/Controller

Instruction Manual. Liquitron DR5000 Series ORP (Redox) Controller. For file reference, please record the following data:

MAXIMA+ Series Rotary Level Indicator

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Series Amp Pad Mount Quick Connect Input and Output Power Panels

PV Rapid Shutdown device

********SERVICE MANUAL******** MODELS:

Service Instructions. Conductor 420

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

RAIN BIRD RC-4Bi, RC-7Bi, RC-1260Bi SERIES INSTRUCTION MANUAL

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Connections 6.

INSTRUCTION MANUAL. ph/mv CONTROLLER/RECORDER

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Ratio Feeder Series J+ Advanced Pumper Controller

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures)

INSTALLATION AND MAINTENANCE INSTRUCTIONS For Chemline A- & Q-Series Actuator with Digital (AC) Positioner

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

SDG1400 User s Guide

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

PEREGRINE SERIES RETROFIT INSTALLATION GUIDE

TRC-190 User s Manual

SIM-9106/9303 High Current Switching Mode Power Supply with C.C., C.V., Remote Control & Sensing User Manual

Differential Liquid/Gas Pressure Transmitter

Sidewinder Pumps Inc. AC Timer/Controller

NT PRESSURE TRANSDUCER MODELS 4100, 4210, 4130, 4230

MT400 MOTION CONTROLLER

Tempco Instruction Manual

PM Series Power Meter

Scanner 2000 Steam Mass Flow Transmitter

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS

InView Marquee Message Display

TRC-190 User s Manual

DirectCommand Installation RoGator Model Year Ag Leader Technology

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

Installation Instructions

ReFlx 100 PLUS COLLISION AVOIDANCE SYSTEM

Ag Leader Technology. DirectCommand Installation RoGator Model Years

Rotork Fairchild PAX1 Linear Actuator User s Manual

INSTALLATION INSTRUCTIONS

Component identification

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1

INTERCOM AMBULANCE/RESCUE VEHICLE MODEL ICA100 SURFACE MOUNT SERIES MODELS ICA200, ICA300 FLUSH MOUNT SERIES MODELS ICA400, ICA500

KTD-125/ KTD-125P/125P-24 KTD-127/127W PTZ Receivers

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112

* * Agilent Power Distribution Unit (PDU) Installation Guide

Total Home Surge Protection for Point-of-Entry. FirstSurge TM. User Manual - Canada (English)

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

FT400-Series RATE/TOTAL INDICATOR INSTRUCTIONS FT415 FT :2008 ISO CERTIFIED COMPANY FT400-SERIES RATE TOTAL/INDICATOR INSTRUCTIONS

M215 (M215-60) Safety

Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection

Thermometer / Barometer System

ACT-1B Series Panel Tachometer

Instruction Manual. ROYTRONIC EXCEL Series AD9 Programming Guide Electronic Metering Pumps

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

VibraLINK switchable junction boxes Installation and operating guide VLL series

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

TARA CONTROLS AGC-5. UCI Random Start USER S GUIDE. With Optional Warning Flashes for the Hearing Impaired. TARA CONTROLS by Cartessa Corporation

Signet Pressure Transmitter

CDD4 Duct Carbon Dioxide Transmitter

Rack Mount Power Supplies

BCM2 Series Branch Circuit Monitors Quick Setup Guide

TPE 1464 Series Pressure Transducer

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Instruction Sheet Board Style Low Water Cutoff

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

HypotULTRA. Quick Start Guide SAFETY CHECKLIST. Survey the test station. Make sure it is safe & orderly.

Capacitive Proximity Sensor E2K-C

GF92 Installation, Operation and Troubleshooting Guide

Instruction Manual. For file reference, please record the following data:

ORB TM 4-20 ma Input Box Installation & Operation Manual

ELECTRO-MECH SCOREBOARD CO.

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

I ntroduction. RA Fast Running Electric Actuator. Features and Benefits

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

MODELS PD230 AND PD1230 Installation Instructions

E2K-C25MY1 E2K-C25MY2

PLC Racks IC697CHS782/783

NightStar. Installation, Operation, & Maintenance Instructions M /04/2016

VM 6.1. Capacitive Air Gap Measuring Chains User s Manual P/N: M7A-110

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Transcription:

Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your LMI Controller or accessory, please include the complete Model Number and Serial Number of your unit. 8 Post Office Square Acton, MA 01720 USA TEL: (978) 263-9800 FAX: (978) 264-9172 http://www.imipumps.com Replaces same of Rev.B 5/99 1914.C 7/99

! CAUTION WARNING: THIS M PUMP MOTOR CONTROLLER IS DESIGNED FOR USE WITH LMI SERIES M PUMPS ONLY. OPERATION WITH OTHER PUMPS OR PRODUCTS MAY CAUSE DAMAGE TO CONTROLLER, PUMP, OR BOTH. THE M PUMP MOTOR CONTROLLER IS DESIGNED TO OPERATE SERIES M PUMPS AT 100 STROKES PER MINUTE (SPM). SERIES M OUTPUTS MAY BE REDUCED UP TO 30% FROM RATED OUTPUT DEPENDING ON MOTOR ON-TIME ADJUSTMENT. 2

Contents 1.0 Introduction...4 1.1 Operating Principle... 4 2.0 Installation...5 2.1 Mounting the Controller Enclosure... 5 2.2 Enclosure Mounting Dimensions... 5 2.3 Electrical Wiring Information...6 2.4 Terminal Strip Layout...6 2.5 Input Signals...7 2.5.1 Input Power to Controller...7 2.5.2 Output Power to M Pump...7 3.0 M Pump Controller Input Signal Connections... 8 3.1 Pulse Signals...8 3.2 4-20 ma Analog Signals... 8 3.3 Low Level Input (Optional)... 8 4.0 Procedures Before Initial Start-up...9 4.1 Checking of Motor Connections... 9 4.2 Checking of 4-20 ma Analog Signal Generator Connections...9 4.3 Adjustment of 'Motor On-time'...9 5.0 Operating the Controller...9 6.0 Troubleshooting...10 7.0 Product Exploded View...11 8.0 Product Parts List...11 3

1.0 Introduction LMI's M Pump Motor Controller provides external control for your Series M Pump for applications that require flow proportional chemical feed or response to control instrumentation. The motor controller will provide one stroke from the pump for each pulse input or will provide direct proportional response to a 4-20 ma input signal. 1.1 Operating Principle The M Pump Motor Controller utilizes phase control technology to pulse the motor. No special motor or drive is required. Because of variables in pumping systems, a motor on-time feature is provided. This enables the pump to be adjusted to provide one complete stroke during each cycle. The motor controller will operate externally from 1-100 strokes per minute or internally from 5-100 strokes per minute. For proper operation, the M pump motor controller must be set and adjusted in compliance with the instructions given in this manual. Pump output may be reduced up to 30% from rated output depending on motor on-time adjustment. 4 Figure 1

2.0 Installation 2.1 Mounting the Controller Enclosure The M pump motor controller is supplied with integral wall-mounting flanges. It should be mounted with the display at eye level on a vibration-free surface. All accessible mounting holes should be utilized. The maximum operating temperature is 122 F (50 C). This should be considered if installation is in a high-temperature location. Maximum distance between motor controller and M pump is 600 ft. (200 meters). Maximum distance between motor controller and external signal is 300 ft. (100 meters). 2.2 Enclosure Mounting Dimensions When using the pre-wired unit, the enclosure is configured as NEMA 12X. If the unit is connected through watertight conduit, the enclosure is configured as NEMA 4X. The following clearances should be observed for proper mounting. Figure 2 5

2.3 Electrical Wiring Information! CAUTION To reduce the risk of electrical shock, the controller must be plugged into a grounded outlet with ratings conforming to the specifications on the data nameplate. It must be connected to a viable ground circuit. DO NOT USE ADAPTERS (see Figure 3)! All wiring must conform to required electrical codes. Figure 3 2.4 Terminal Strip Layout To access the wiring connections inside the controller: 1. Disconnect the unit from electrical power. 2. Remove the four (4) screws and the junction box cover on the lower half of the unit. 3. Consult the specific instructions below for the connections required. AC Power Input (Controller) Hot: Neutral: Ground: T1 T2 T3 AC Power Output (Pump) Hot: Hot: Ground: T5 T6 T7 Signal Input (External) Pulse Trigger: T9 Pulse Trigger: T10-4-20 ma: T11 + 4-20 ma: T12 Figure 4: Terminal Strip Layout 6

2.5 Input Signals The motor controller is supplied with a 10 ft. (3 meter) cable fitted with a 4-pin connector for connection to the external control device. The signal can be pulse type (water meter, ph meter, etc.) or analog type (4-20 ma). Only two of the four conductors will be connected as shown in the following diagram: Pulse Input 1 : White 2 : Black Analog Input 3 : Green (-) 4 : Red (+) (Prewired 4-pin connector) Figure 5: Connection of two conductors (Analog or Pulse) 2.5.1 Input Power to Controller AC power Input (115V and 230V M pumps) The M pump motor controller is supplied with a six-foot power cord and plug. 2.5.2 Output Power to M Pump AC Output power (115V M pumps) A 6'' output power cord with receptacle supplies power to 115V Series M pump. AC Output power (230V M pumps) A PG-9 connector is supplied for hard-wire connection to the 230V Series M pump. 1. Check the M pump data plate for proper voltage (230V). 2. Remove the 4 screws to the junction box cover. 3. Cut away the M pump power cord plug. 4. Route the M pump power cord through the PG-9 connector. 5. Hard-wire the M pump cord to the controller terminal strip. 6. Reinstall the junction box cover. The maximum distance between the M pump motor controller and the M pump is 600 ft. (200 meters). 7

3.0 M Pump Controller Input Signal Connections 3.1 Pulse Signals: Using the input cable, connect the white and black conductors to your pulse output. There is no polarity requirement for the connection. The red and green conductors may be cut. Pulse inputs must be between 0-100 per minute. Pulse signals must be capable of switching 15 VDC @ 8 milliamperes. Minimum time in the low impedance state (on) is 50 milliseconds. Minimum time in high impedance state (off) is 100 milliseconds. 3.2 4-20 ma Analog Signals: Using the input cable, connect the red and green conductors to your 4-20 ma analog output. Connections must be made with respect to polarity. Connect the red conductor to positive (+) and the green conductor to negative (-). The white and black connectors may be cut. The pump will respond directly and proportionally to the 4-20 ma input. 4 ma = 0 strokes per minute (no output) 20 ma = 100 strokes per minute (max output) The maximum distance between the M pump motor controller and the pulse or 4-20 ma source is 300 ft. (100 meters). Extension cables are available from your local LMI distributor. In addition, if electrical noise is present, the installation of a sealed junction box and shielded two-conductor cable should be considered. Also note, cable should be routed via a separate electric raceway from the power supply. 3.3 Low Level Input (Optional): When used in conjunction with LMI s optional low-level switch accessory (P/N 29190), pump and controller operations are interrupted when the chemical supply is low, preventing loss of prime. The EMPTY light on the front panel illuminates alerting the operator to replenish the chemical supply. 8

4.0 Procedures Before Initial Start-up 4.1 Checking of Motor Connections Set the manual speed control knob to 30%. Set the MODE switch to INTERNAL. Check motor rotation, it must be in accordance with the arrow stamped on the motor. To reverse motor rotation, refer to the information contained in the motor terminal box. 4.2 Checking of 4-20 ma Signal Input Set the MODE switch to EXTERNAL. Send an input signal and check the pump response. If the pump does not respond to the signal, verify signal polarity. 4.3 Adjustment of Motor 'On-time' Adjust the potentiometer (on-time) to setting 1. To achieve accurate metering, it may be necessary to adjust the motor on-time to the service conditions. The higher the discharge pressure and stroke length, the longer on-time that is required. To modify the motor on-time, adjust the potentiometer (on-time): from 1 to 5 to increase this time, from 5 to 1 to reduce this time. This adjustment, defined for given pressure and stroke conditions may then be checked by calibration (monitoring the rate at which reagent is used). 5.0 Operating the Controller The M pump motor controller provides a switch for operation in three modes. INTERNAL: OFF: EXTERNAL: Operates the pump by means of the speed control knob from 5-100 strokes per minute. Light is ON when pump is under manual control. Pump off. Automatic and proportional control by a pulse signal (0-100 spm) or by a 4-20 ma analog signal (4 ma = 0 spm, 20 ma = 100 spm). Light is ON when pump is under auto control. 9

6.0 Troubleshooting! CAUTION Disconnect power to the controller before opening the front panel or removing the control panel! Troubleshooting and repair of a malfunctioning controller should only be attempted by qualified personnel using caution to insure safety and to limit further damage. Contact your local LMI distributor for assistance. Problem No Internal or External Light on front panel No power to pump Internal light stays ON and pump doesn't come on Motor cycles erratically Pump is not responding to pulse or ma signal Empty light stays on Possible Cause Blown fuse No power supplied Loose/incorrect wiring Incorrect wiring Pump has failed Speed set too low Pulser has failed Motor on-time adjustment set too high or too low Toggle switch set to Internal mode Wires are incorrectly connected If level switch is used, check for low level in tank If level switch is not used, switch may be faulty Solution Disconnect power supply, remove control panel and check fuse; replace if necessary. Check power source. Verify wiring connection Check wiring Plug pump directly into live outlet Increase speed Replace pulser Readjust motor on-time Set toggle switch to External mode Check wire connections. 4-20 ma must maintain proper polarity Refill tank Consult factory 10

7.0 Product Exploded View 8.0 Product Parts List Item Part Description No. No. 1 32558 Terminal Strip 2 25957-1 Cord Clamp 3 30749 Power Cord, 115 V 30751 Power Cord, 230 V US 30752 Power Cord, DIN 34783 Power Cord, UK 34754 Power Cord, AUST 34784 Power Cord, SWISS 4 33566 Terminal, Solder Lug.640 I.D. 5 35711 Cord, Power Output (115 VAC only) 6 32395 Screw, Self Tapping (8) 7 37495 Housing, Motor Controller 8 33249 Control Panel Asm. 9 33250 Filter, RFI 10 37500 Fuse Holder, 5x20 mm 11 37499 Fuse, 5x20 mm 12 37501 Screw, Self Tapping, #6x.50 FH SS (2) 13 34088 Cover, Utility Box 14 34074 Gasket, Foam 15 37494 Label, Terminal Cover, Controllers 16 30588 Label, LMI Logo 17 37493 Label, Terminal Connections 18 32186 Screw, 4-40x.37 FH SS (2) 19 32187 Nut, 4-40 Flush Threads (2) 20 32209 Latch, Liquitron Housing 21 32211 Cap (2) 22 32352 O-Ring, Sponge 23 31617 Cover 24 25628 Nut, 6-32 Hex SS (2) 25 33346 Screw, 6-32x.375 FH SS (2) 26 36739 Connector Asm, #18 Wire (4-pin connector) 27 30709B Speed Knob Not Shown 33796 External Input Cable, 10 ft. (4-20 ma or Pulse Input) 11

1999 LMI Milton Roy - All Rights Reserved Printed in USA Specifications subject to change without notice. 8 Post Office Square Acton, MA 01720 USA TEL: (978) 263-9800 FAX: (978) 264-9172 http://www.imipumps.com