LoadMaster Clustering

Similar documents
LoadMaster Clustering (Beta)

Migration Tool. Migration Tool (Beta) Technical Note

VMware vcenter Log Insight Manager. Deployment Guide

Moodle. Moodle. Deployment Guide

RSA Two Factor Authentication

Packet Trace Guide. Packet Trace Guide. Technical Note

Adobe Connect. Adobe Connect. Deployment Guide

Splunk. Splunk. Deployment Guide

NTLM NTLM. Feature Description

LoadMaster VMware Horizon (with View) 6. Deployment Guide

Epic. Epic Systems. Deployment Guide

Hyper-V - Windows 2012 and 8. Virtual LoadMaster for Microsoft Hyper-V on Windows Server 2012, 2012 R2 and Windows 8. Installation Guide

KEMP Driver for Red Hat OpenStack. KEMP LBaaS Red Hat OpenStack Driver. Installation Guide

SDN Adaptive Load Balancing. Feature Description

LoadMaster for Azure (Marketplace Classic Interface)

Configuring Real Servers for DSR

Edge Security Pack (ESP)

LoadMaster VMware Horizon Access Point Gateway

MS Lync MS Lync Deployment Guide

MS Skype for Business. Microsoft Skype for Business Deployment Guide

Web Application Firewall (WAF) Feature Description

VMware Horizon Workspace. VMware Horizon Workspace 1.5. Deployment Guide

GEO. Feature Description GEO VERSION: 1.4 UPDATED: MARCH Feature Description

Condor for Cisco UCS B-Series Blade Servers

Health Checking. Health Checking. Feature Description

Content Switching with Exchange and Lync-related Workloads

Kerberos Constrained Delegation. Kerberos Constrained Delegation. Feature Description

Virtual LoadMaster for Xen (Para Virtualized)

SSL Accelerated Services. SSL Accelerated Services for the LM FIPS. Feature Description

DirectAccess. Windows Server 2012 R2 DirectAccess. Deployment Guide

Virtual LoadMaster for KVM (Para Virtualized)

Bar Code Discovery. Administrator's Guide

Web User Interface (WUI) LM5305 FIPS

Tenable Hardware Appliance Upgrade Guide

Open Source Used In Cisco Configuration Professional for Catalyst 1.0

iwrite technical manual iwrite authors and contributors Revision: 0.00 (Draft/WIP)

Web User Interface (WUI) LM FIPS

Documentation Roadmap for Cisco Prime LAN Management Solution 4.2

IETF TRUST. Legal Provisions Relating to IETF Documents. Approved November 6, Effective Date: November 10, 2008

PRODUCT SPECIFIC LICENSE TERMS Sybase Enterprise Portal Version 5 Application Edition ( Program )

Simba Cassandra ODBC Driver with SQL Connector

Exchange 2016 Deployment Guide. Exchange Deployment Guide

Web User Interface (WUI)

IETF TRUST. Legal Provisions Relating to IETF Documents. February 12, Effective Date: February 15, 2009

Command Line Interface (CLI)

PRODUCT SPECIFIC LICENSE TERMS Sybase Enterprise Portal Version 5 Enterprise Edition ( Program )

Installing the Shrew Soft VPN Client

Cover Page. Video Manager User Guide 10g Release 3 ( )

Copyright PFU LIMITED

Open Source Used In TSP

KEMP 360 Central Activation Server

Enterprise Payment Solutions. Scanner Installation April EPS Scanner Installation: Quick Start for Remote Deposit Complete TM

RADIUS Authentication and Authorization Technical Note

Ecma International Policy on Submission, Inclusion and Licensing of Software

LoadMaster Deployment Guide

SDLC INTELLECTUAL PROPERTY POLICY

Ecma International Policy on Submission, Inclusion and Licensing of Software

Trimble. ecognition. Release Notes

Juniper Networks Steel-Belted Radius Carrier

Open Source Used In c1101 and c1109 Cisco IOS XE Fuji

Validating Service Provisioning

US Government Users Restricted Rights - Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.

User Manual. Date Aug 30, Enertrax DAS Download Client

Panasonic Audio Player 2 User Guide

Cover Page. Site Studio Tutorial Setup Guide 10g Release 3 ( )

Polycom RealPresence Resource Manager System

Table of Contents Overview...2 Selecting Post-Processing: ColorMap...3 Overview of Options Copyright, license, warranty/disclaimer...

XEP-0099: IQ Query Action Protocol

User Guide. Calibrated Software, Inc.

SkyPilot OS Installation: Fedora Core 5

Technics Audio Player User Guide

Data Deduplication Metadata Extension

Additional License Authorizations for HPE OneView for Microsoft Azure Log Analytics

Migrating Performance Data to NetApp OnCommand Unified Manager 7.2

Open Source and Standards: A Proposal for Collaboration

KEMP LoadMaster. KEMP LoadMaster. Product Overview

CA File Master Plus. Release Notes. Version

Fujitsu ScandAll PRO V2.1.5 README

HALCoGen TMS570LS31x Help: example_sci_uart_9600.c

Microsoft Exchange Microsoft Exchange Deployment Guide

This file includes important notes on this product and also the additional information not included in the manuals.

Polycom RealPresence Access Director System, Virtual Edition

Conettix Universal Dual Path Communicator B465

Copyright PFU LIMITED 2016

Microsoft Hyper-V Installation Guide

Bar Code Discovery. Administrator's Guide

FOR TCG ACPI Specification

Intel Stress Bitstreams and Encoder (Intel SBE) 2017 AVS2 Release Notes (Version 2.3)

OnCommand Unified Manager 7.2: Best Practices Guide

PageScope Box Operator Ver. 3.2 User s Guide

Hyperscaler Storage. September 12, 2016

SMS2CMDB Project Summary v1.6

ColdFusion Builder 3.2 Third Party Software Notices and/or Additional Terms and Conditions

NetApp Cloud Volumes Service for AWS

HIS document 2 Loading Observations Data with the ODDataLoader (version 1.0)

The Privileged Appliance and Modules (TPAM) 1.0. Diagnostics and Troubleshooting Guide

MagicInfo Express Content Creator

Management Software Web Browser User s Guide

CB-RBE231 PRODUCT GUIDE

This file includes important notes on this product and also the additional information not included in the manuals.

Transcription:

Introduction LoadMaster Clustering Feature Description VERSION: 9.0 UPDATED: JULY 2016

Copyright Notices Copyright 2002-2016 KEMP Technologies, Inc.. All rights reserved.. KEMP Technologies and the KEMP Technologies logo are registered trademarks of KEMP Technologies, Inc.. KEMP Technologies, Inc. reserves all ownership rights for the LoadMaster product line including software and documentation. The use of the LoadMaster Exchange appliance is subject to the license agreement. Information in this guide may be modified at any time without prior notice. Microsoft Windows is a registered trademarks of Microsoft Corporation in the United States and other countries. All other trademarks and service marks are the property of their respective owners. Limitations: This document and all of its contents are provided as-is. KEMP Technologies has made efforts to ensure that the information presented herein are correct, but makes no warranty, express or implied, about the accuracy of this information. If any material errors or inaccuracies should occur in this document, KEMP Technologies will, if feasible, furnish appropriate correctional notices which Users will accept as the sole and exclusive remedy at law or in equity. Users of the information in this document acknowledge that KEMP Technologies cannot be held liable for any loss, injury or damage of any kind, present or prospective, including without limitation any direct, special, incidental or consequential damages (including without limitation lost profits and loss of damage to goodwill) whether suffered by recipient or third party or from any action or inaction whether or not negligent, in the compiling or in delivering or communicating or publishing this document. Any Internet Protocol (IP) addresses, phone numbers or other data that may resemble actual contact information used in this document are not intended to be actual addresses, phone numbers or contact information. Any examples, command display output, network topology diagrams, and other figures included in this document are shown for illustrative purposes only. Any use of actual addressing or contact information in illustrative content is unintentional and coincidental. Portions of this software are; copyright (c) 2004-2006 Frank Denis. All rights reserved; copyright (c) 2002 Michael Shalayeff. All rights reserved; copyright (c) 2003 Ryan McBride. All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. THIS SOFTWARE IS PROVIDED BY THE ABOVE COPYRIGHT HOLDERS ''AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE ABOVE COPYRIGHT HOLDERS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. The views and conclusions contained in the software and documentation are those of the authors and should not be interpreted as representing official policies, either expressed or implied, of the above copyright holders.. Portions of the LoadMaster software are copyright (C) 1989, 1991 Free Software Foundation, Inc. -51 Franklin Street, Fifth Floor, Boston, MA 02110-1301, USA- and KEMP Technologies Inc. is in full compliance of the GNU license requirements, Version 2, June 1991. Everyone is permitted to copy and distribute verbatim copies of this license document, but changing it is not allowed. Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 2

Portions of this software are Copyright (C) 1988, Regents of the University of California. All rights reserved. Redistribution and use in source and binary forms are permitted provided that the above copyright notice and this paragraph are duplicated in all such forms and that any documentation, advertising materials, and other materials related to such distribution and use acknowledge that the software was developed by the University of California, Berkeley. The name of the University may not be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED ``AS IS'' AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Portions of this software are Copyright (C) 1998, Massachusetts Institute of Technology Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions: The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software. THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE. Portions of this software are Copyright (C) 1995-2004, Jean-loup Gailly and Mark Adler This software is provided 'as-is', without any express or implied warranty. In no event will the authors be held liable for any damages arising from the use of this software. Permission is granted to anyone to use this software for any purpose, including commercial applications, and to alter it and redistribute it freely, subject to the following restrictions: 1. The origin of this software must not be misrepresented; you must not claim that you wrote the original software. If you use this software in a product, an acknowledgment in the product documentation would be appreciated but is not required. 2. Altered source versions must be plainly marked as such, and must not be misrepresented as being the original software. 3. This notice may not be removed or altered from any source distribution. Portions of this software are Copyright (C) 2003, Internet Systems Consortium Permission to use, copy, modify, and/or distribute this software for any purpose with or without fee is hereby granted, provided that the above copyright notice and this permission notice appear in all copies. THE SOFTWARE IS PROVIDED "AS IS" AND THE AUTHOR DISCLAIMS ALL WARRANTIES WITH REGARD TO THIS SOFTWARE INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS. IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY SPECIAL, DIRECT, INDIRECT, OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS, WHETHER IN AN ACTION OF CONTRACT, NEGLIGENCE OR OTHER TORTIOUS ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS SOFTWARE. Used, under license, U.S. Patent Nos. 6,473,802, 6,374,300, 8,392,563, 8,103,770, 7,831,712, 7,606,912, 7,346,695, 7,287,084 and 6,970,933 Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 3

Table of Contents 1 Introduction... 5 1.1 Document Purpose... 5 1.2 Intended Audience... 5 2... 6 2.1 Prerequisites... 6 2.2 Restrictions... 6 2.3 Clustering Overview... 7 2.4 Configuring Clustering... 7 2.4.1 Create a New Cluster and Add Nodes to it... 8 2.4.2 Remove a Node LoadMaster from the Cluster... 13 2.4.3 Changing the Cluster Parameters... 14 2.4.4 Backing Up and Restoring the Configuration... 15 2.5 Cluster-Wide Software Updates... 15 2.6 Clustering WUI Options... 17 2.6.1 General WUI Options... 17 2.6.2 Cluster Control WUI Options... 18 2.6.3 Cluster Interface Options... 22 2.6.4 Cluster-Wide Software Update WUI Options... 22 2.7 Application Program Interface (API) Commands... 23 2.8 Troubleshooting... 23 References... 25 Document History... 26 Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 4

Introduction 1 Introduction Clustering involves deployment of multiple LoadMaster instances (nodes) as a single management and control domain where each node is actively passing traffic. If any of these nodes fail - the remaining nodes continue to provide service to the remote client, providing resilience. Clustering supports scaling - LoadMaster nodes can be added to or removed from a cluster so that capacity can be dynamically adjusted to match business requirements. Each additional LoadMaster node which is added to the cluster can provide a linear increase in throughput and performance. The maximum number of nodes that can be added to a cluster is defined by your license agreement. An example use case is - if a website experiences higher than usual traffic during a holiday period and the amount of traffic cannot be predicted in advance - often the capacity is over-provisioned to handle these requests that come in spikes. One of the simplest solutions is to deploy LoadMasters in a cluster and then add new nodes as the capacity requirements (concurrent connections and performance requirements) increase. 1.1 Document Purpose The purpose of this document is to provide information on the LoadMaster clustering feature and step-by-step instructions on how to set up and configure clustering. 1.2 Intended Audience This document is intended to be read by anyone who is interested in finding out more about LoadMaster clustering. Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 5

2 2.1 Prerequisites There are some prerequisites to be aware of before clustering LoadMasters: A minimum of three LoadMasters are needed to set up clustering. However, four LoadMasters are recommended. All of the LoadMasters in the cluster must be physically identical in terms of the hardware used. Clustering also works with Virtual LoadMasters but the Virtual Machines must have the same resources assigned; this includes CPU, memory and Hard Disk Drive (HDD). Once an empty machine is brought into the cluster, all parameters from the other machines (network interfaces, etc.), are copied over onto the new machine. Local addresses for network interfaces must then be set. 2.2 Restrictions Most functionality that is available in a single LoadMaster is available when a LoadMaster environment is clustered. The only restrictions are listed below: All Virtual Services must operate at Layer 7 Transparency cannot be enabled Subnet originating addresses are always enabled Non-local Real Servers are not supported High Availability (HA) mode cannot be used VXLAN and IPsec tunneling are not supported Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 6

2.3 Clustering Overview Figure 2-1: LoadMaster clustering - example architecture With LoadMaster clustering, the load-balancing capability can be extended as needed by adding additional LoadMasters for the same Virtual Service. Traffic which is intended for a failed node is either passed on to an existing node or load-balanced across the remaining nodes. The LoadMasters all work in parallel. If a LoadMaster node fails, traffic is redistributed amongst the remaining nodes. Health checking is performed on each of the LoadMasters. Most administrative changes should be made on the shared IP address interface. These changes are then propagated to the LoadMasters in less than a second. Local administration of the individual LoadMasters can also be performed by accessing the WUI of the units directly. The WUI of the local LoadMasters contains limited configuration options. 2.4 Configuring Clustering If clustering is enabled on the LoadMaster, the Cluster Control menu item will be available under System Configuration in the main menu of the LoadMaster WUI. If clustering functionality is not enabled and you would like to use it, please contact your KEMP representative. Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 7

2.4.1 Create a New Cluster and Add Nodes to it To set up a cluster and add LoadMaster nodes to it, follow the steps in the sections below, in order. 2.4.1.1 Create a New Cluster To create a new cluster, follow the steps below on a LoadMaster WUI: 1. In the main menu of the LoadMaster WUI, go to System Configuration > HA and Clustering. Figure 2-2: HA Mode or Clustering 2. This screen describes both HA Mode and Clustering. Select Clustering and click Confirm. Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 8

Figure 2-3: Convert to Cluster 3. Click Create New Cluster. Figure 2-4: Creating a New Cluster 4. Enter the desired shared IP address for the cluster. This is the address that will be used to access the shared WUI where configuration changes should be made. 5. Click Create a New Cluster. Figure 2-5: Rebooting 6. The LoadMaster will then reboot. A prompt will appear asking to reconnect to the shared IP address. 7. Click Continue. When the LoadMaster has rebooted, you will be brought to the shared IP address. The cluster is now set up. The next step is to add a LoadMaster to the cluster. Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 9

2.4.1.2 Add a Node LoadMaster to the Cluster To add a node LoadMaster to the cluster, the node LoadMaster needs to become available and then have its IP address added in the shared IP address WUI. To do this, follow the steps below: 1. In the node WUI, go to System Configuration > Cluster Control in the main menu. 2. Click Add to Cluster. Figure 2-6: Add to Cluster Figure 2-7: Waiting to Join Cluster The LoadMaster is now available to be added to the cluster. 3. Open the WUI of the shared IP address. 4. In the main menu, go to System Configuration > Cluster Control. Figure 2-8: Add New Node 5. Enter the IP address of the node LoadMaster in the Address text box. 6. Click Add New Node. This must be done while the node LoadMaster is available to join the cluster. Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 10

Figure 2-9: Reboot 7. The node LoadMaster needs to reboot to finish the conversion to cluster mode. Click Continue. Figure 2-10: Enable node 8. By default, the new node will be disabled. Click Enable to enable the node in the cluster. When a node is enabled, it will not be immediately brought into rotation. It will only come online after it has been up for 30 seconds. The page may need to be refreshed to display any state changes. If there are no Virtual Services in the node, the node will be in a Disabled state. 9. Click OK. The cluster is now configured and a node has been added. To add more nodes, repeat the steps in Section 2.4.1.2. When all nodes have been added to the cluster, other configuration changes can be made - such as creating and configuring Virtual Services. These changes will be propagated from the shared IP address to the LoadMaster nodes. 2.4.1.3 Configure the Network Interface(s) Some configuration changes are needed on the interfaces. Refer to the sections below for further details. 2.4.1.3.1 Set the Cluster Shared IP Address The cluster shared IP address needs to be set on any interfaces that will be used to handle traffic. To do this, follow the steps below: 1. In the main menu of the shared IP address LoadMaster WUI, go to System Configuration > Network Setup. Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 11

2. Click the relevant interface link. Figure 2-11: Network Interface Management 3. Enter the Cluster Shared IP address and click Set Shared address. 2.4.1.3.2 Enable the Use for Cluster Checks Option The Use for Cluster checks option must be enabled on at least one interface. To enable this option, follow the steps below: 1. In the main menu of the LoadMaster WUI, expand System Configuration. 2. Click the relevant interface. Figure 2-12: Network Interface Management 3. Tick the Use for Cluster Checks check box. 2.4.1.3.3 Enable the Use for Default Gateway Option The Use for Default Gateway option needs to be enabled on each of the LoadMasters. To do this, follow the steps below: 1. In the main menu of a node LoadMaster, expand System Configuration. 2. Click the relevant interface. Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 12

Figure 2-13: Network Interface Management 3. Tick the Use for Default Gateway check box. 2.4.2 Remove a Node LoadMaster from the Cluster It is possible to remove a node LoadMaster from the cluster which will mark the node as unavailable for new traffic (i.e. a Draining state) to facilitate the removal from the cluster. To do this, follow the steps below in the shared IP address WUI: 1. In the main menu, go to System Configuration > Cluster Control. Figure 2-14: Cluster Control 2. Click Disable on the node to be removed. Before a node can be deleted, it must first be disabled. The node must also be online. A node cannot be deleted if it is handling traffic. 3. The node will change to a Draining state. Wait for the node to finish draining and change to a Disabled state. The page will need to be refreshed to see the new state. Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 13

When a node is in the Draining state, the connections that are still being served by the node are allowed to continue for the amount of time specified in the Node Drain Time text box. For more information, refer to Section 2.6.2.1. No new connections will be handled by the node during this time. 4. Click Delete to remove the node from the cluster. 5. Click OK to confirm the removal. 6. Click OK to the confirmation message. When a node is deleted it becomes a regular single LoadMaster instance. If the LoadMaster is later added back in to the cluster, any configuration changes that have been made in the shared IP address will propagate to the node LoadMaster. 2.4.3 Changing the Cluster Parameters The cluster Virtual ID and node drain time can be updated, if needed. Refer to the sections below for further information. 2.4.3.1 Updating the Cluster Virtual ID When using multiple clusters or LoadMaster HA systems on the same network, the virtual ID identifies each cluster so that there are no potential unwanted interactions. To change the cluster ID, follow the steps below in the shared IP address WUI: 1. In the main menu, go to System Configuration > Cluster Control. 2. Click the Show Options button. 3. Change the Cluster Virtual ID value. Table 2-1: Cluster Virtual ID 4. Click Set Cluster Virtual ID. 2.4.3.2 Updating the Node Drain Time Valid values range from 1 to 255. When a node is disabled, the connections that are still being served by the node are allowed to continue for the amount of seconds specified in the Node Drain Time text box. No new connections will be handled by the node during this time. The Node Drain Time is set to 10 Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 14

seconds by default. To change the Node Drain Time, follow the steps below in the shared IP address WUI: 1. In the main menu, go to System Configuration > Cluster Control. 2. Click the Show Options button. Table 2-2: Set Node Drain Time 3. Change the value in the Node Drain Time text box. Valid values range between 1 and 600 (seconds). 4. Click Set Node Drain Time. 2.4.4 Backing Up and Restoring the Configuration Backups can be taken and restored as usual in the System Configuration > System Administration > Backup/Restore section of the LoadMaster WUI. Backups and restores should only be performed on the shared IP address because the changes made there will be propagated to the other nodes. When restoring, the individual LoadMasters will be rebooted, one at a time. There are certain settings that need to be set in the Virtual Services for them to work with clustering: Transparency must be disabled Subnet Originating Requests must be enabled All Virtual Services must operate at Layer 7. High Availability (HA) mode cannot be used As a result of these restrictions, there may be issues with restoring a backup taken from a noncluster LoadMaster on to a cluster LoadMaster and vice versa, because the settings may be incompatible. 2.5 Cluster-Wide Software Updates The firmware on all LoadMasters in a cluster can be updated via the shared IP address. Software updates require the LoadMasters to be rebooted. However, the nodes can be rebooted one by one so there is no down time. Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 15

To perform a cluster-wide software update, follow the steps below in the WUI of the shared IP address: 1. Get a LoadMaster firmware patch file. Visit support.kemptechnologies.com or Contact KEMP Support to get a LoadMaster firmware patch. 2. In the main menu, go to System Configuration > Update Software. Table 2-3: Update Cluster 3. Click Choose File. 4. Browse to and select the firmware update patch file. 5. Click Update Cluster. 6. Click OK to continue. Table 2-4: Validating software update 7. Wait for the software update to be transferred and validated. 8. Click OK to install the software update. Table 2-5: Software Update Validated Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 16

9. A message will appear saying that the new software has been installed and the Cluster Control screen will be displayed. 10. Each of the non-admin nodes need to be rebooted in order to activate the software. Click Reboot to reboot a node. 11. Click OK to the pop-up message. 12. When all non-admin nodes have been rebooted, the admin node needs to be rebooted. Click Reboot in the admin node row to reboot the admin node. 2.6 Clustering WUI Options 2.6.1 General WUI Options Figure 2-15: Cluster Control If clustering functionality is enabled on a non-node LoadMaster, a Cluster Control menu option should be available in the WUI within the System Configuration section. Figure 2-16: Convert to Cluster Before setting up clustering, clicking the Cluster Control menu item will give the option to either create a new cluster or add this LoadMaster to a cluster. Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 17

Figure 2-17: Local IP menu Figure 2-18: Shared IP menu When logging in to the cluster, use the shared IP address to view and set the full functionality of the cluster nodes. Logging in to the local IP address of any of the nodes displays different menu options (see menus above). Logging in to one of the nodes directly is usually reserved for maintenance. 2.6.2 Cluster Control WUI Options Figure 2-19: Cluster Options Create New Cluster: If setting up a new cluster, click this button. Add to Cluster: Add this LoadMaster to an already existing cluster. Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 18

Figure 2-20: Creating a New Cluster When the Create New Cluster button is clicked, the screen above will appear which prompts to set the shared IP address of the cluster. The shared IP address is the address which will be used to administer the cluster. Figure 2-21: Rebooting When the Create a Cluster button is clicked, the LoadMaster reboots. A message will appear asking to reconnect to the shared IP address that was just set. Figure 2-22: Cluster Control After creating a cluster, the Cluster Control screen in the WUI of the shared IP address will allow the addition of LoadMaster nodes into the cluster. A LoadMaster can only be added to a cluster when the cluster is available and waiting to join the cluster. Refer to Section 2.4.1.2 for further information and steps. Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 19

Figure 2-23: Cluster Control The Cluster Control screen, in the shared IP address WUI, displays details for each of the nodes in the cluster. Show Options: Clicking the Show Options button will display the Cluster Parameters section which contains two additional fields which can be used to set the Cluster Virtual ID and Node Drain Time. For further information, refer to Section 2.6.2.1. ID: The cluster ID. Address: The IP address of the LoadMaster node. If a second IP address appears in brackets after the first one - the second IP address is the IP address of the interface port. The IP address and status text will be coloured depending on the status: Blue: The node is the master node. Yellow: The node is disabled. Green: The node is up. Red: The node is down. Status: The status of the node. The possible statuses are: Admin: The node is the primary control node. Up: The node is up. Down: The node is down. Drain stopping: The node has been disabled and the connections are being shut down in an orderly fashion. Drain stopping lasts for 10 seconds by default. This can be updated by changing the Node Drain Time value on the Cluster Control screen. For more information, refer to Section 2.4.3.2. Starting: The node is starting Disabled: The node is disabled - connections will not be sent to that node. If there are no Virtual Services in the node, the node will be in a Disabled state. Operation: The different operations that can be performed in relation to the notes: Add new node: Add a new node with the specified IP address to the cluster. Disable: Disable the node. Nodes that are disabled will first go through drain stopping. During the drain stopping time, the connections are shut down in an orderly fashion. After the drain, the node will be disabled and no traffic will be directed to that node. Enable: Enable the node. When a node comes up, it will not be immediately be brought into rotation. It will only come online after it has been up for 30 seconds. Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 20

Delete: Delete a node from the cluster. When a node is deleted it becomes a regular single LoadMaster instance. If the LoadMaster is later added back in to the cluster, any configuration changes that have been made in the shared IP address will propagate to the node LoadMaster. 2.6.2.1 Cluster Parameters Figure 2-24: Cluster Parameters When the Show Options button is clicked, the Cluster Parameters section appears. This section contains two additional WUI options - Cluster Virtual ID and Node Drain Time. Cluster Virtual ID When using multiple clusters or LoadMaster HA systems on the same network, the virtual ID identifies each cluster so that there are no potential unwanted interactions. The cluster virtual ID is set to 1 by default, but it can be changed if required. Valid IDs range from 1 to 255. Changes made to an admin Loadmaster propagate across all nodes in the cluster. Node Drain Time When a node is disabled, the connections that are still being served by the node are allowed to continue for the amount of seconds specified in the Node Drain Time text box. No new connections will be handled by the node during this time. The Node Drain Time is set to 10 seconds by default, but it can be changed if required. Valid values range from 1 to 600 (seconds). During the drain time the status changes to Draining until the specified drain time elapses. When the drain time has elapsed the status changes to disabled. Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 21

2.6.3 Cluster Interface Options There are a couple of fields relating to clustering in the Network Interface management screen. Figure 2-25: Network Interface Management To get to this screen, go to System Configuration > Network Setup in the main menu of the LoadMaster WUI and click one of the interfaces. The cluster-related options are described below. Cluster Shared IP address Specify the shared IP address which can be used to access the cluster. This is also used as the default source address when using Server NAT. Use for Cluster checks Use this option to enable cluster health checking between the admin Loadmaster and the nodes. At least one interface must be enabled. Use for Cluster Updates Use this interface for cluster synchronization operations. 2.6.4 Cluster-Wide Software Update WUI Options Table 2-6: Update Cluster The firmware on all LoadMasters in a cluster can be updated via the shared IP address. This can be done in System Configuration > System Administration > Update Software by using the Update Cluster option. Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 22

After the firmware update patch has been uploaded, a new Reboot button will appear on the Cluster Control screen. When you click Reboot, a pop-up message will appear saying that the node is rebooting. For more information, including step-by-step instructions on how to perform a cluster-wide software update, refer to Section 2.5. 2.7 Application Program Interface (API) Commands KEMP supports three APIs that can be used to allow remote applications to access the LoadMaster in a simple and consistent manner: RESTful API PowerShell API Java API Clustering can be configured using API commands. For details on each of the commands that can be used, refer to the relevant API Interface Description document on the KEMP documentation page: www.kemptechnologies.com/documentation. 2.8 Troubleshooting Logs are recorded to track certain clustering events, such as when a node goes offline. Viewing the logs can help to troubleshoot problems which may occur. To view the logs relating to clustering, in the LoadMaster WUI go to System Configuration > Logging Options > System Log Files. The logs relating to clustering are available in the Warning Message File and the System Message File. Some examples of log entries relating to clustering are listed and described below. The following log example shows a node failing and another node becoming the main admin node. lb100 ucarp[2994]: [WARNING] Switching to state: MASTER lb100 ucarp[21751]: [CRITICAL] Partner has failed, becoming MASTER ucarp[2995]: [WARNING] Switching to state: MASTER ucarp[2995]: [WARNING] Preferred master advertised: going back to BACKUP state ucarp[2995]: [CRITICAL] Partner Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 23

has failed, becoming MASTER lb100 l4d: HA state changed: now master. The following log example shows a node going offline. This could be because the node was rebooted. lb100 l4d: Node 3 now dead lb100 l4d: Cluster running on only 3 of 4 nodes The following log example indicates that a node has gone offline. lb100 l4d: Cluster running on 3 of 4 nodes (1 disabled) The following log example indicates that a node is alive, for example a disabled node has been enabled. lb100 l4d: Node 3 now alive Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 24

References References Unless otherwise specified, the following documents can be found at http://kemptechnologies.com/documentation. PowerShell, Interface Description High Availability (HA), Feature Description Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 25

Document History Document History Date Change Reason for Change Version Resp. Apr 2015 Initial draft First draft of document 1.0 LB June 2015 Changes to reflect beta Beta version changes 1.1 LB Aug 2015 New sections added API steps added 3.0 LB Sep 2015 Release updates Updates for 7.1-30 4.0 LB Oct 2015 Release updates Updated screenshots 5.0 LB Dec 2015 Release updates Updates for 7.1-32 6.0 LB Jan 2016 Minor updates Updated Copyright Notices 7.0 LB Mar 2016 Minor updates Enhancements made 8.0 LB July 2016 Release updates Updated for 7.1.35 9.0 LB Copyright 2002-2016 KEMP Technologies, Inc. All Rights Reserved. 26