USER GUIDE ARDBOX ANALOG

Similar documents
USER GUIDE ARDBOX ANALOG HF. Version: IS_AB20ANA.7.1

USER GUIDE ARDBOX ANALOG

USER GUIDE ARDBOX RELAY

M-DUINO FAMILY. M-Duino 21 User Guide: 1 Index

M-DUINO R FAMILY. M-Duino 19R/38R/57R User Guide: 1 Index

USER GUIDE PLC Arduino ARDBOX 20 I/Os Analog HF Modbus

USER GUIDE. PLC Arduino ARDBOX 20 I/Os Relay HF. Cat. Nº: ABOX

M-DUINO FAMILY. M-Duino Family User Guide: Ref. IS.MDUINO.XXX

M-DUINO PLUS FAMILY. M-Duino PLUS Family User Guide: Ref. IS.MDUINO.XXX

ARDBOX FAMILY USER GUIDE

Products Datasheet. The economic automation products. ü Fast programming with internet community

ARDUINO LEONARDO WITH HEADERS Code: A000057

ARDUINO MICRO WITHOUT HEADERS Code: A000093

Sanguino TSB. Introduction: Features:

ARDUINO LEONARDO ETH Code: A000022

ARDUINO MEGA 2560 REV3 Code: A000067

Arduino Uno. Arduino Uno R3 Front. Arduino Uno R2 Front

7. Approved Standards US: UL, CSA UL: FILE No.E CSA: FILE No.LR31928) 8. Special Function None : Standard U : For ultrasonically cleanable

ARDUINO MEGA ADK REV3 Code: A000069

keyestudio Keyestudio MEGA 2560 R3 Board

ESPino - Specifications

ARDUINO UNO REV3 SMD Code: A The board everybody gets started with, based on the ATmega328 (SMD).

Arduino ADK Rev.3 Board A000069

ARDUINO UNO REV3 Code: A000066

Process displays For current and voltage

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

ARDUINO YÚN MINI Code: A000108

XH2. Half-pitch Board-to-Board Connectors

SS Series Compatible Mounting with a Simple Construction and Easy-to-Use Design Concept

Despite its ultra-slim design, a CPM2C system can provide up to 192 I/O points!

BMX DDM Mixed Relay Input/Output module

XC7. DIN Sequence Connectors. An improved DIN-standard Sequence. Connectors. connectors. Ratings and Characteristics. Materials and Finish

5. Terminal Shape P: PCB Terminals 6. Classification None : Standard ST : Stand-off 0.64 mm 15 : High-sensitivity (150 mw) Low-sensitivity

XC5. DIN-style Twin-contact Connectors. Expanding the DIN Concept. Materials and Finish. Ratings and Characteristics

ARDUINO YÚN Code: A000008

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

ARDUINO M0 PRO Code: A000111

IDUINO for maker s life. User Manual. For IDUINO Mega2560 Board(ST1026)

CPU Units with 20 I/O points

IDUINO for maker s life. User Manual. For IDUINO development Board.

FEATURES DESCRIPTION FEATURES

ARDUINO MINI 05 Code: A000087

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

Programmable Relay ZEN V2 Units

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Beetle SKU:DFR0282. Contents. Introduction

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

Model Number Structure

Safety Relay Unit (I/O Unit Type)

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

E2K-X4ME1 2M E2K-X4ME2 2M

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

Arduino Uno R3 INTRODUCTION

ARDUINO PRIMO. Code: A000135

icex-cmtm General specs and Installation guide

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

Model Number Structure

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

SmartSlice I/O Plug-and-Play I/O. System Configuration

Breeze Board. Type A. User Manual.

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

Thread length (overall length) material

Millenium II +: general characteristics

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

E2Q4 Square Proximity Sensor

Switch Mode Power Supply S8VT 120/240/480/960 W Models

NJ-Series Power Supply Unit NJ-PA/PD

Ultratronics v1.0 DATASHEET

RS 485 Mini Modbus 1AO

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

V E2B Snap-in I/O Module

TCNM-ACBB1 Installation Manual

PK2200 Series. Features. C-Programmable Controller. Specifications Board Size Enclosure Size Operating Temp.

KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual

RS485 MODBUS Module 8I8O

IST ULTRASTAB Power Supply for high precision transducers

Making Hazardous Operations Safe and Productive

V E1B Snap-in I/O Module

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Model Number Structure

Solder terminals D2FD-2L0-1H D2FD-01L0-1H. PCB terminals D2FD-2L0-1T D2FD-01L0-1T. Hinge lever Solder terminals D2FD-2L1-1H D2FD-01L1-1H

LVX Control Unit. Features:

Model Number Structure

GENERAL PRECAUTIONS GENERAL DESCRIPTION... 6

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

BSL Hardware Guide for MP35 and MP30-1 -

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Switched Mode Power Supply Operating manual PAP800

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

LGR-5325 Specifications

LGR-5327 Specifications

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Transcription:

USER GUIDE ARDBOX ANALOG Version: 00300170_Ardbox_Analog

Page2 Ardbox User Guide: 1 Contents 2 ARDBOX... 3... 4 3 Precautions... 4 1.1. Arduino Board... 4 1.2. Intended Audience... 4 1.3. General Precautions... 4 4 Technical Specifications... 5 4.1 General Specifications:... 5 4.2 Performance Specification:... 6 5 Software interface... 6 6 How to connect PLC Arduino to PC... 7 7 How to connect PLC to power supply... 8 8 Ardbox Analog I/O Pinout:... 9 Zone Connections... 9... 10 9 Switch configuration... 11 10 I/0 technical details... 13 11 Connector details... 15 12 ARDBOX Family Dimensions:... 17 13 DIN rail mounting:... 17

Page3 2 ARDBOX A compact PLC based in Open Source Hardware technology. With different Input/Outputs Units. COMPACT PLC ARDUINO 1224Vdc ARDBOX ANALOG Alimentation Voltage 1224Vdc Fuse protection (1A) Polarity protection Max. current consumption 0,5A Size Clock Speed Flash Memory SRAM 100x45x115 16MHz 32KB of which 4KB are used by bootlader 2.5KB EEPROM 1KB I2C Communications USB RS232 RS485 SPI TOTAL Input points 10 TOTAL Output points 10 INPUTS Digital range:12/24 Vdc (7.6 to 25.4 Vdc) Analog range: 010 Vdc Digital 10 12/24Vdc I min: 3/6 ma Separated PCB ground Analog 10 bits 9 of 10 Digital input 010V Input Impedance: 39K Separated PCB ground * Interrupt HS 1 of 10 Digital input 12/24Vdc I min: 5/10 ma Separated PCB ground *The same input is not simultaneously compatible as InterrupHS and Digital. IMPORTANT 1 Pullup resistance required for i2c (IS.ACI2C4.7K)

Page4 OUTPUTS Digital Isolated range: 5/12/24 Vdc (4.6 to 25.4 Vdc) Analog range: 010 Vdc Digital Isolated 10 5/12/24 Vdc I max: 0.3 A Galvanic INSULATION Diode Protected for Relay Analog 8 bits 7 010 Vdc I max: 40 ma Separated PCB ground PWM Isolated 8bit 6 of 10 Digital isolated Output 5/12/24 Vdc I max: 0.3 A Galvanic INSULATION Diode Protected for Relay Expandability I2C 1 RS232 RS485 SPI Reference IS.AB20AN.base 3 Precautions Read this manual before attempting to use the Ardbox and follow its descriptions for reference during operation 1.1. Arduino Board All Ardbox family PLCs include Arduino LEONARDO Board as controller. 1.2. Intended Audience This manual is intended for technicians, which must have knowledge on electrical systems. 1.3. General Precautions The user must operate Ardbox according to the performance specifications described in this manual. Before using Ardbox under different conditions from the what is specified in this manual or integrating Ardbox to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment and other systems, machines, and equipment that may have a serious influence on lives and property if used improperly, consult your INDUSTRIAL SHIELDS representative. Ensure that the rating and performance characteristics of Ardbox are sufficient for the systems, machines, and

Page5 equipment, and be sure to provide the systems, machines, and equipment double safety mechanisms. This manual provides information for programming and operating the Ardbox. Warnings: Unused pins should not be connected. Ignoring the directive may damage the controller. Improper use of this product may severely damage the controller. Refer to the controller s User Guide regarding wiring considerations. Before using this product, it is the responsibility of the user to read the product s User Guide and all accompanying documentation. 4 Technical Specifications 4.1 General Specifications: Power supply voltage DC power supply 12/24Vdc Operating voltage range DC power supply 11.4 to 25.4Vdc Power consumption DC power supply 30VAC max. External power supply Power supply voltage Power supply output capacity 12/24Vdc 700Ma Insulation resistance Dielectric strength Shock resistance 20MΩ min.at 500Vdc between the AC terminals and the protective earth terminal. 2.300 VAC at 50/60 HZ for one minute with a leakage current of 10mA max. Between all the external AC terminals and the protective earth terminal. 80m/s2 in the X, Y and Z direction 2 times each. Ambient temperature (operating) 0º to 45ºC Ambient humidity (operating) 10% to 90% (no condensation) Ambient environment (operating) With no corrosive gas Ambient temperature (storage) 20º to 60ºC Power supply holding time 2ms min. Weight 340g max.

Page6 4.2 Performance Specification: Arduino Board Control method I/O control method Programming language Microcontroller Flash Memory Program capacity (SRAM) EEPROM Clock Speed ARDUINO LEONARDO Stored program method Combination of the cyclic scan and immediate refresh processing methods. Arduino IDE. Based on wiring (Wiring is an Open Source electronics platform composed of a programming language. similar to the C. http://arduino.cc/en/tutorial/homepage ATmega32u4 32kb of which 4 kb are used by bootloader 2.5kb 1kb 16MHz 5 Software interface Industrial Shields programming environment is Arduino IDE. https://www.arduino.cc/en/main/software You can download start code for Ardbox Relay at www.industrialshields.com, section 20 IOs PLCs /Ardbox Relay / Document files.

Page7 6 How to connect PLC Arduino to PC Connect USB cable from PLC to PC. NOTE: Ardbox Family use micro USB cable. Open Arduino IDE interface: Available at: http://arduino.cc/download.php?f=/arduino1.0.6windows.exe Select Arduino Board NOTE: Ardbox integrates Arduino Leonardo as controller board. Select correct port. IMPORTANT: Verify the USB port is detected:

Page8 7 How to connect PLC to power supply Ardbox Family PLCs are 1224Vdc supplied. IMPORTANT: The polarity IS NOT REVERSAL! Make sure that the live and GND connector of the power supply match the PLC. Make sure that the power supply mains output is not higher than 24Vdc. Suggested power suppliers * Not recommended for industrial applications. The Jack connector needs to be removed and use the live and GND connectors.

Page9 Ardbox Connector Arduino Pin Function Ardbox Connector Arduino Pin Function 8 Ardbox Analog I/O Pinout: Zone Connections Base (common unit) RIGHT Zone RIGHT Zone A0.6 A0.5 A0.4 A0.3 A0.2 A0.1 A0.0 Q0.9 3 5 6 9 10 11 13 0 Analog Out Analog Out Analog Out Analog Out Analog Out Analog Out Analog Out Digital Output Switch config* (see section 9 for Analog/Digital Outputs configuration) Analog Outputs pinout Q0.8 1 Digital Output Q0.7 7 Digital Output Q0.6 Q0.5 Q0.4 Q0.3 Q0.2 Q0.1 Q0.0 GNDCOM 24VCOM 3 5 6 9 10 11 13 PWM/digital Output PWM/digital Output PWM/digital Output PWM/digital Output PWM/digital Output PWM/digital Output PWM/digital Output Isolated GND Isolated VIN Digital/PWM Output pinout Isolated VIN/GND for Outputs Power supply connectors (24Vdc Gnd) Base (common unit) LEFT Zone LEFT Zone RE DE SCL SDA TX RX A B GND 5V RESET SCK MOSI MISO I0.9 I0.8 I0.7 I0.6 I0.5 I0.4 I0.3 I0.2 I0.1 I0.0 7 4 3 2 0 1 A0 A1 A2 A3 A4 A5 4 8 12 2 RS485/SPI(SS) RS485/SPI(SS) I2C/SPI(SS) I2C/SPI(SS) RS232 RS232 RS485 RS485 GND 5V OUT RESET SPI SPI SPI Analog/Digital Input Analog/Digital Input Analog/Digital Input Analog/Digital Input Analog/Digital Input Analog/Digital Input Analog/Digital Input Analog/Digital Input Analog/Digital Input Digital interrupt Switch config* (see section 9 for Switch configuration. Enabling Communications disables some I/Os) Communications pinout (SPI, I2C, RS485, RS232) Inputs pinout

Page10 Config switch * (see section 9 for communications configuration) Input / Output LED Power LED Arduino Reset button

Page11 9 Switch configuration General Switches Configurations TOP ZONE ENABLED CONNECTION ON OFF Q0.1 Q0.1 RO RO RO Q0.1 Q0.2 Q0.2 DI DI DI Q0.2 LEFT ZONE SWITCH CONFIGURATION ARDUINO PIN OFF* ON 7 DE Q0.7 4 RE I0.3 1 Q0.8 RX 0 Q0.9 TX 2 SDA I0.0 3 SCL Q0.6 *IMPORTANT: LEFT ZONE. To enable communication connections the switchs must be set to OFF. Set to ON position to enable I/Os PLC connection. Communications and I/Os on the chart can not work simultaneously. For exemple if DE is enabled (OFF), Q0.7 will not work. OFF position provides direct connection to Arduino Pin (NOT for TX and RX), so they can be programmed according to Arduino pin features. TOP ZONE. Communications and outputs can not work simultaneously. If Q0.1 is enabled RO must be disabled and conversely. RS 485 Switch configuration RS485 CONFIGURATION TOP ZONE LEFT ZONE Q0.1 OFF DE OFF RO ON RE OFF Q0.2 OFF RX (ON/OFF) DI ON TX (ON/OFF) SDA SCL (ON/OFF) (ON/OFF) RS485: Enable RE/DE/DI and RO internal pins with configuration switches. I0.3, Q0.1, Q0.2 and Q0.7 not available. The defined Arduino Mega pins for RS485 are showed in the chart below.

Page12 RS232 Switch configuration RS232 CONFIGURATION TOP ZONE LEFT ZONE Q0.1 (ON/OFF) DE (ON/OFF) RO (ON/OFF) RE (ON/OFF) Q0.2 (ON/OFF) RX ON DI (ON/OFF) TX ON SDA (ON/OFF) SCL (ON/OFF) RS232: Enable RX and TX connections with configuration switches. Q0.8 and Q0.9 not available I2C Switch configuration i2c CONFIGURATION TOP ZONE LEFT ZONE Q0.1 (ON/OFF) DE (ON/OFF) RO (ON/OFF) RE (ON/OFF) Q0.2 (ON/OFF) RX (ON/OFF) DI (ON/OFF) TX (ON/OFF) (ON/OFF) SDA SCL OFF OFF I2C: Enable SCL and SDA connections (direct Arduino pins) with configuration switches. I0.0 and Q0.6 not available. In order to implement this communication a 4.7kΩ pullup resistor (IS.ACI2C4.7K) is required. Analog/Digital Output Switch Configuration RIGHT SIDE SWITCH CONFIG Output ON OFF NC NC NC Q0.6 DIGITAL A0.6 Q0.5 DIGITAL A0.5 Q0.4 DIGITAL A0.4 Q0.3 DIGITAL A0.3 Q0.2 DIGITAL A0.2 Q0.1 DIGITAL A0.1 Q0.0 DIGITAL A0.0

Page13 10 I/0 technical details Digital Output Waveform Digital Output Turnoff PWM Waveform

Page14 Analog Out Turnon Analog Out Turnoff Analog/Digital Input Turnon

Page15 Analog/Digital Input Turnoff 11 Connector details The connector inside the PLCs that mounts on the PCB is MC 0,5/10G2,5 THT 1963502 from Phoenix contact. MC0,5/10G2,5THT For I/O and power supply there is a FKMC 0,5/10ST2,5 1881406 connector from Phoenix contact. FKMC 0,5/10ST2,5 Connection details: Article reference Height MC 0,5/10G2,5 THT 8,1mm Pitch 2,5mm Dimension 22,5mm Pin dimensions 0,8x0,8mm Pin spacing 2,50mm

Page16 Article reference Rigid conduit section min. FKMC 0,5/10ST2,5 0,14 mm² Rigid conduit section max. 0,5 mm² Flexible conduit section min. 0,14 mm² Flexible conduit section max. 0,5 mm² Conduit section AWG/kcmil min. 26 Conduit section AWG/kcmil max. 20

Page17 12 ARDBOX Family Dimensions: 13 DIN rail mounting: 45mm width

Page18 About Industrial Shields: SPAIN Divina Pastora 1315 Baixos 3 08241 Manresa (Barcelona) Tel.+34 635693611 Mail: industrialshields@industrialshields.com