Multi-Ser vice Access Network Features Combined SONET - SDH ADM and E1/T1- PDH multiservice DACS 6U height, full front access (ETSI) shelf TM, ADM and DCS at DS0, VC12, VC3, VC4 Dual STM-1/4 - OC-3/12 Optical Ring Uplinks Hot-swappable cross-connect modules, tributary modules and power modules. Tributary Modules (See Table1 below) High-Speed or High Density access tributary modules HS Low-Speed access tributary modules (LS) Power Modules DC (-48Vdc) *AC (90 to 240V, 50/60Hz) Dual Power (1+1) Protection Networking Tributary E1/T1: Card, Port, Line E3/T3: Card, Port, Line B155/622: MSP, SNCP Cross-connect Unit (XCU) SDH Protection MSP, SNCP PDH Protection 1+1 and w 3E1 card SNCP PDH 64K TM, ADM, and cross-connect Full cross-connect at VC11/VC12/VC3/VC4 levels External/Internal/Line timing source with SSM Ethernet supports GFP, LAPS, VCAT and LCAS Full switch Ethernet capability on EoS card DTMF Engineering Order-Wire using VoIP phone Alarm suppression, masking and report Management Console port, VT100 menu SNMP Port Telnet Centralized management EMS-GUI CXRview CXR s EMS/iNMS EMS TMN management,full FCAPS endto end circuit management SSH The HX9500 SONET/SDH-PDH is a Hybrid Multi-Service Access Multiplexer with STM-1/4 - OC-3/12 optical lines aggregate and HS tributaries and a non-blocking VC11/VC12/VC3/VC4 cross-connect together with a PDH DS0 cross-connect or DACS with Low Speed tributary modules. The 6U shelf delivers: - 4 High Speed tributary module slots - 6 Low Speed tributary module slots With up to 4 aggregate optical STM- 1/4 - OC-3/12 or electrical STM-1/OC- 3 line interfaces, the HX9500 SONET/ SDH offers service providers a versatile scheme including UPSR/SNCP and MSP(1+1) for both ring and linear network topologies. It can operate with the HX9100 and HX9400 multiplexers in the same topology. The HS tributary modules include optical STM-1/4 - OC-3/12, E3/T3, E1/T1 interfaces and Fast Ethernet over STM-1/4 - OC-3/12. Fast Ethernet signals are mapped into the SONET - SDH payload through standard techniques such as GFP, LAPS, VCAT and LCAS. These HS modules are the same models for the HX9400 SONET-SDH multiplexer. DESCRIPTION The LS tributary modules are connected through a full non-blocking DS0 crossconnect matrix so delivering an integrated mini DACS system. All interfaces are fully compliant with the relevant ITU ETSI and ANSI standards. The hybrid SONET/SDH-PDH provides full Operation, Administration, Maintenance and Provisioning (OAM&P) functionalities. Users can easily operate the HX9500R locally or remotely for centralized management together with HX9400R, QX3440/S/D and different product of CXR ranges with CXRview-Plus (EMS) and CXR-iNMS (integrated NMS).
Page 2 - Multi-Service Access Network Power THE HX9500 R Fans Connector b.d Smart Solutions for Smart Networks 4 SDH slots 6 PDH slots www.cxr.com SDH TOPOPLOGIE OF THE HX9500R The HX9500R structure with two CPU/Aggregate HX9400R-CC5 give it the possibility to deploy different topologies of SDH aggregates and tributaries. This configuration support 2 SNCP ring STM1/4 or 2 MSP 1+1 or one SNCP + MSP (1+1) STM1/4 ring with 4 fibers or 4 independent STM1/4. Each interface STM1 or STM4 are independent and can be selected by the selection of optical module or the settling for multi-rate SFP module. CXR Anderson Jacobson Rue de l'ornette 28410 Abondant - France T +33 (0) 237 62 87 90 F +33 (0) 237 62 88 01 email: contact@cxr.com
Page 3 - Multi-Service Access Network HX9500R THE RIGHT PROTECTION FOR PDH and SDH EDGE PDH ACCESS SDH CORE QX3440 QX3440S HX9400R HX9416R 1+1 SNCP-64K over PDH SNCP-64K over PDH in SDH HX9500R SNCP MSP 1+1 SNCP+MSP SNCP MSP 1+1 SNCP MESH SNCP+MSP EoPDH L2: RSTP L3: Static, RIP, OSPF EoSDH E-LINE: SNCP LCAS E-LAN: RSTP
Page 4 - Multi-Service Access Network SPECIFICATIONS Physical/Electrical HX9500R-6U HX9x00R-FILTER HX9x00R-FILTER-CBL-T 6U chassis 433mm x 264mm x 223,5mm (W/H/D) 0,5U chassis 433mm x 22mm x 223,5mm (W/H/D) 2U chassis 433mm x 88mm x 223,5mm (W/H/D) AC Power 90 to 240 VAC, 50/60Hz * DC 48v Power -36 to 72 Vdc ± 15% DC 24v Power Temperature By use of DC 48v card and a 1U 19 chassis with dual channel converter 24V to 48V the DCDC-2X24-48-300W-1U DC 17 to 31 V to DC 48 V 300W each channel -5 to +55 C Humidity Mounting EOW LAN port Console port E1/T1 interface connector Optical Interface connector Number of Optical STM-x Number of E1/T1 channels 0-95%RH (non-condensing) Desk-top stackable, 19/23 inch rack mountable supply with brackets, and wall mountable 2 * RJ-11 FXS, for Analog Circuit Telephone Device (Tip/ Ring), including SIPv2 technology 2* RJ-45, Lan ports for SNMP administration, 100BT DB-9F SCSI-II 68 pins SFP module with LC connectors Up to 6 STM4 or 10 STM1 Card of 16E1/T1, 32 E1/T1 or 63 E1/ 63T1 Smart Solutions for Smart Networks www.cxr.com Clock Source Up to 4 clocks with priority from : Internal, STM-N Line 4 aggregate, 2 External input 2MHz or G704 w or w/o SSM, E1 PDH source, 2 output clocks Management Interface Console port Standard OSS interface NE/NE interface Alarm Input/Output Standards Compliance DB9F, RS232 DCE, user interface VT100 menu driven SNMP V1 and V3 (RFC1213, RFC2571 to RFC2575) 10/100BaseT FE (IEEE 802.3u ), Telnet and SSH V2 DCC/HDLC/Ethernet type II Inputs Ports 4 Activation current 3 ma Internal resistance 1K Deactivation current 1.5 ma Connectors Outputs RJ45 Ports 4 Maximum switching voltage 110 Vdc, 125 Vac Initial insul. resist. Connectors Use ITU-T Min. 100M ohm (at 500Vdc) ANSI T1.105, T1.107 RJ45 SNMP TRAP or Transmission from Input to Output G.703, G.707, G.751, G.747, G.7041, G.7042, G.775, G.783, G.806, G.813, G.823, G.824, G.826, G.841, G.747, X.86, G.664 IEEE 802.1q & 802.1ad(VLAN), 802.1w(RSTP), 802.1s(MSTP), 802.3x(flow control), 802.3u, 802.1p(QoS) Certification CXR Anderson Jacobson Rue de l'ornette 28410 Abondant - France T +33 (0) 237 62 87 90 F +33 (0) 237 62 88 01 email: contact@cxr.com EMC: FCC Part 15 Subpart B, Class A; EN 55022, Class A; EN55024; EN300 386 * In test for DC48v only: IEC61850-3, IEEE1613 for utilization in electric substation The information contained in this document are provided without warranty and do not constitute a contractual document. In order to improve its products, CXR reserves its right to modify, without notice, any part of this document and the specification it contains.
Page 5 - Multi-Service Access Network HX9500R CAPACITY WITH 2 CC4 TRIBUTARY TG 1 TG2 AGGREGATES PDH Tributaries GROUP SLOTS TRIB 1 TRIB 2 TRIB 3 TRIB 4 CC4 W CC4 E T1 T2 T3 T4 T5 T6 GLOBAL 4 X 155M N/A 2 X 155M N/A 2 x 622M 2 x 622M 4 x 2M 4 x 2M 4 x 2M 4 x 2M 4 x 2M 4 x 2M PAYLOAD 2 x 155M 2 x 155M 1 x 155M 1 x 155M Link without MSP Link with MSP (1+1) STM-1 STM-1 STM-4 STM-4 N/A STM-4 No SDH Maxi 252 E1 63 E1 63 E1 63 E1 63 E1 or 126 (1+1) 63 E1 63 E1 (P) 63 E1 63 E1 (P) Max. 12 E3 3 E3 3 E3 3 E3 3 E3 or 6 (1+1) 3 E3 3 E3 (P) 3 E3 3 E3 (P) 32 FE or 4 GE w/o 16 FE or 2 GE w 1+1 Maximum 6 x 4E1, unique clock Maximum 3 x 4E1, unique clock, 1+1 Maximum 6 x 3E1, unique clock, SNCP * Maximum 3 x 3E1, unique clock, 1+1 and SNCP * 8 FE or 1 GE 8 FE or 1 GE 8 FE or 1 GE 8 FE or 1 GE 8 FE 8 FE 8 FE 8 FE 8 FE 8 FE BUS SDH to this 6 PDH 8 FE or 1 GE 8 FE or 1 GE Cards 8 FE or 1 GE 8 FE or 1 GE EoPDH 64k to 2M to 8M per card Protection Protection of 21E1 to 21 VC12 28 FOM w/o 14 FOM w 1+1 Protection Protection Use All QX3440 card 1 and 2 slots HX9500 TRIBUTARY MODULES High-Speed or High Density Access Tributary Modules (HS) plug-in Interface cards STM-1/4 - OC-3/12 tributaries 63x ports E1/T1 tributaries 32x ports E1/T1 tributaries 16x ports E1/T1 tributaries 3x ports E3/T3 tributaries EoS (8xFE+1xGBE) Ethernet card with built in a L2 switch (E-Line/E-LAN) EoS (8xFE+1xGBE) Ethernet card without switch (E-Line) The High Speed card are can be used in HX9400R or HX9500R without modification. Please looks to HX9400R datasheet for tributary specifications. Low-Speed Access Tributary Modules (LS) plug-in Interface Cards 4x channel E1/T1 3 x channel E1 with SNCP 64K support* 8x channel Dry Contact I/O 8x channel 2W/4W E&M 8x channel G703-64K Codirectionnal 2x channel G.SHDSL (2 pairs) 4x channel G.SHDSL (1 pairs) 12x channel FXS 12x channel FXO 8x channel OCU-DP 1x or 4x channel C37.94 (low speed optical) 8x port Bridge/Router EoPDH 64Kbps to 2M to 8Mbps 6x channel V.35 6x channel V.36 6x channel X.21 8x channel RS232, 8 RS485 and 8 Bridge RS232 The Low Speed PDH cards are can be used in QX3440/QX3440S or HX9500R without modification. Please looks to QX3440 datasheet for tributary specifications.
Page 6 - Multi-Service Access Network