This specification this document to get an official version of this User Network Interface Specification

Similar documents
If you want to get an official version of this User Network Interface Specification, please order it by sending your request to:

If you want to get an official version of this User Network Interface Specification, please order it by sending your request to:

This specification this document to get an official version of this User Network Interface Specification

Suppliers' Information Note. BT International Megastream 155. Service Description

SDH Principle. Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

EUROPEAN ETS TELECOMMUNICATION April 1997 STANDARD

Final draft ETSI EN V1.4.1 ( )

CPOS Interface. Synchronous digital hierarchy (SDH), defined by CCITT (today s ITU-T), uses a SONET rate subset.

STI 25 Edition 1/May 2002

ITU-T G.832. Transport of SDH elements on PDH networks Frame and multiplexing structures

learntelecoms interactive e-learning suite of courses: SyncNet v6 SDH-based broadband networks SyncNet

TRANSPORT OF SDH ELEMENTS ON PDH NETWORKS: FRAME AND MULTIPLEXING STRUCTURES ITU-T

Customer Interface Publication: KCH CIP009. Technical Characteristics of the kbit/s (155Mbit/s) digital leased line

Technical Committee. E3 Public UNI. af-phy

Reference Access and Interconnection Offer

JJ TTC STANDARDS. Physical Layer Specifications of kbit/s Optical. Subscriber Line. Version 1. Nov

Transmission Technology Ses SDH

TELENOR SPECIFICATION

Draft EN V1.1.1 ( )

Table of Contents 1 E-CPOS Interface Configuration 1-1

What is SDH? Telecommunications Standards Primer. Plesiochronous Digital Hierarchy (PDH) Limitations of PDH Network

ITU-T G.774. Synchronous digital hierarchy (SDH) Management information model for the network element view

Tandem Connection Monitoring: Fundamentals, Operation, Test Solutions

Technical Committee. E1 Physical Interface Specification. af-phy

INTERNATIONAL TELECOMMUNICATION UNION

INTERNATIONAL TELECOMMUNICATION UNION

Tandem Connection Monitoring: Fundamentals, Operation, Test Solutions

This specification this document to get an official version of this User Network Interface Specification

INTERNATIONAL TELECOMMUNICATION UNION. SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Digital networks General aspects

SONET. By Sadhish Prabhu. Unit II

Suppliers' Information Note. BT MegaStream 622, BT MegaStream Aggregate (STM4) Service Description

INTERNATIONAL TELECOMMUNICATION UNION

COPYRIGHTED MATERIAL INTRODUCTION TO OPTICAL TRANSPORT CHAPTER 1

INTERNATIONAL TELECOMMUNICATION UNION

FPGA BASED IMPLEMENTATION OF STM-16 FRAMER IP CORE

Suppliers Information Note. Synchronisation Recommended Settings for Customer Premises Equipment

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Application Note. Re-timing: Cost-effective Synchronization via Re-timed E1 and DS1 Signals. Precision, Stability, Innovation, Support.

INTERNATIONAL TELECOMMUNICATION UNION

CMA 3000, all-in-one field tester SDH test options

Network Topologies & Error Performance Monitoring in SDH Technology

S Optical Networks Course Lecture 5: TDM-Based Networks

Customer Interface Publication: KCOM (Hull) CIP010

INTERNATIONAL TELECOMMUNICATION UNION

RECOMMENDATION ITU-R S

ES V1.1.1 ( )

EUROPEAN ETS TELECOMMUNICATION March 1998 STANDARD

ITU-T G.828. Error performance parameters and objectives for international, constant bit rate synchronous digital paths

Tandem connection monitoring

ANT-20SE Advanced Network Tester ANT-20 NEXT Network Expert Test Software

INTERNATIONAL TELECOMMUNICATION UNION INTEGRATED SERVICES DIGITAL NETWORK (ISDN) INTERNETWORK INTERFACES AND MAINTENANCE PRINCIPLES

Transport Network Technologies

)454 ' $)')4!,,).% 3934%-3 "!3%$ /. 4(% 39.#(2/./53 $)')4!, ()%2!2#(9 &/2 53% /. /04)#!, &)"2% #!",%3 $)')4!, 3%#4)/.3!.$ $)')4!,,).

ITU-T G.824. The control of jitter and wander within digital networks which are based on the 1544 kbit/s hierarchy

Displaying Overhead Bytes

ANT-20SE Advanced Network Tester PDH MUX/DEMUX

VCL-TP, Teleprotection Equipment

INTERNATIONAL TELECOMMUNICATION UNION

ANT-20, ANT-20E Advanced Network Tester Extended Overhead Analysis

Final draft ETSI EN V1.2.1 ( )

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Digital terminal equipments General

The Development of an SDH Simulator using a Software Defined Radio Platform

SIN 158 Issue 3.6 May 2018

JP 3GA (R99) UTRAN Iu Interface Layer 1

VePAL TX150E. Key Features. Platform Highlights. Handheld SDH/PDH Test Set. Transport Expert

Acknowledgements. No part of this guide may be reproduced in any form or by any means without the prior written permission of EXFO.

SONET network testing simplified. Key Features

3G TS V3.2.0 ( )

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

SONET Testing and Maintenance

DIGITAL TRANSMISSION MEASURING INSTRUMENTS

3GPP TS V8.0.0 ( )

DIGITAL TRANSMISSION MEASURING INSTRUMENTS

Backbone network technologies. T Jouni Karvo, Timo Kiravuo

3GPP TS V ( )

Be the First without uncertainties! Tandem Connection Monitoring. The principle of TCM TCM analysis. White Paper. July 99

NGN - SYNCHRONOUS DIGITAL HIERARCHY

)454 ) )3$.4/)3$.,!9%2 ).4%2.%47/2+ ).4%2&!#% ).4%'2!4%$ 3%26)#%3 $)')4!,.%47/2+ )3$. ).4%2.%47/2+ ).4%2&!#%3. )454 Recommendation )

Suppliers' Information Note. BT LAN Extension Service Service Description

Technical Committee. 2.4 Gbps Physical Layer Specification AF-PHY

Suppliers Information Note. BT MediaNet Plus Network Service. Interface Characteristics & Withdrawal Notification

)454 ' 3YNCHRONOUS $IGITAL (IERARCHY 3$( UNIDIRECTIONAL PERFORMANCE MONITORING FOR THE NETWORK ELEMENT VIEW

OTM2515/2516/ M/622M/2.5GSDH/SONET Test Module

VePAL UX400 Universal Test Platform

VictoriaSDH/ATM/IP. Multi-Layer Testing SDH/ATM/IP. in a single tester

Network Working Group. Category: Standards Track Overture Networks R. Cohen, Ed. Resolute Networks D. Zelig Corrigent Systems April 2007

White paper Application note

)454 ' 39.#(2/./53 $)')4!, ()%2!2#(9 3$( 0%2&/2-!.#% -/.)4/2).' &/2 4(%.%47/2+ %,%-%.4 6)%7 '%.%2!,!30%#43 /& $)')4!, 42!.3-)33)/.

For internal circulation of BSNL only

R 155. ZyFLEX. A Fiber Optical Multiplexer For Future-Proof Telecom Solutions.

ETSI TS V8.0.0 ( ) Technical Specification

Backbone network technologies. T Jouni Karvo, Timo Kiravuo

BROADBAND AND HIGH SPEED NETWORKS

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Digital networks Quality and availability targets

Customer Interface Publication: KCOM (Hull) CIP019

Configuring SDH on 1-Port OC-192/STM-64 or 8-Port OC-3/12/48/STM-1/-4/-16 Module

ETSI TS V5.0.0 ( )

ERROR RATE MODELLING. Vladislav Skorpil. Keywords: BER, SES, BBE, ESR, SESR, simulation 1. INTRODUCTION

CMA 5000 extended Transport Analysis Application

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Digital networks Design objectives for digital networks

Transcription:

This specification describes the situation of the Proximus network and services. It will be subject to modifications for corrections or when the network or the services will be modified. Please take into account that modifications can appear at any moment. Therefore, the reader is requested to check regularly with the most recent list of available specifications that the document in one's possession is the latest version. Proximus can't be held responsible for any damages due to the use of a version of this specification which is not included in the most recent list of available specifications (list always available with a request to the e-mail address mentioned in the underneath paragraph). Whilst every care has been taken in the preparation and publication of this document, errors in content, typographical or otherwise, may occur. If you have remarks concerning its accuracy, please send a mail to the following address Proximus.uni.spec@Proximus.be and your remark will be transmitted to the right Proximus department. The User Network Interface Specifications published via Internet are available for your information but have no official value. The only documents with an official value are printed on a specific paper. If you want to get an official version of this User Network Interface Specification, please order it by sending your request by mail to Proximus.uni.spec@Proximus.be

Page A

Table of Contents 0. 1. DOCUMENT HISTORY...1 INTRODUCTION...2 2. 3. CONNECTION CHARACTERISTICS...4 2.1. Common characteristics of STM-4 (4 VC-4 into 1 STM-4) and VC-4-4c (1 VC-4-4c into 1 STM-4) leased line connections...4 2.1.1. Tolerance of VC timing...4 2.1.2. Transfer delay for VC-4...4 2.1.3. Transfer delay for VC-4-4c...4 2.1.4. Jitter...4 2.2. Specific characteristics of a STM-4 (4VC-4 into 1 STM-4) leased line connection...5 2.2.1. Information transfer susceptance...5 2.2.2. Performance objectives...5 2.3. Specific characteristics of a VC-4-4c (1 VC-4-4c into 1 STM-4) leased line connection...6 2.3.1. Information transfer susceptance...6 2.3.2. Performance objectives...7 THE NTP (STM-4 INTERFACE)...8 3.1. 3.1.1. 3.2. 3.3. 3.4. 3.5. 3.6. Physical section layers...8 STM-4 optical interface...8 STM-4 regenerator and multiplex section layers...9 Path layer functions... 10 Safety... 10 ElectroMagnetic Compatibility (EMC)... 10 TU/VC numbering scheme... 11 4. TERMINAL EQUIPMENT... 12 ANNEX 1... 13 ANNEX 2... 14 Page a

0. Document history Every update of this document results in a complete new version with new version number and release date. Version Date Main or important changes since previous version 1.0 10 DEC 2002 First version Page 1

1. Introduction This document contains the technical specifications for the Proximus STM-4 (4 VC-4 into 1 STM-4) and VC-4-4c (1 VC-4-4c into 1 STM-4) digital leased line services. The digital leased line provides a bidirectional point-to-point digital connection within a STM-4 frame in accordance with ITU-T Recommendation G.707. The network interface presentation offered to a STM-4 (4 VC-4 into 1 STM-4) and a VC-4-4c (1 VC-4-4c into 1 STM-4) leased lines customer is based on the G957-interface. The rules applied by PROXIMUS for interfacing the customer's equipment with the PROXIMUS SDH network are based on the G.707 and G.957 ITU-T recommendations. Only Optical interfaces are available. The network cabling follows the standard Proximus rules. These leased line specifications are based on a generic model as shown in figure 1. The SDH connection is presented to the customer via an "interface presentation" at the Network Termination Point (NTP) which comprises all physical connections and their technical access specifications that form part of the Proximus SDH leased line network. This connection includes a series of SDH sections, providing the point-to-point transfer of signals between the terminal equipment of the customer. The NTP is also the point at which the terminal equipment of the customer is attached to the SDH leased line offering an STM-4 interface; the attachment requirements for the customer's terminal equipment are also mentioned in this document. The STM-4 (4 VC-4 into 1 STM-4) digital leased line service can be offered everywhere in the SDH Proximus network. The VC-4-4c (1 VC-4-4c into 1 STM-4) digital leased line service can only be offered in the Proximus ZTC and LTC where MSH51c or MSH64 are installed. Throughout this document, reference is made to several national and international standards; details of these publications are given in annex 2. In addition, the list of the abbreviations which apply to this document, can be found in annex 1. Page 2

Generic model for STM-4 and VC-4-4c Leased Line Specifications Proximus network VC-4 or VC-4-4c available NTP STM-4 SDH Equipment MSH51c MSH64 Customer Terminal Customer Terminal STM-4 STM-4 SDH Equipment SMA Customer Terminal VC-4 only available EP Figure 1 The drawing represents a point-to-point digital leased lines service. Page 3

2. Connection characteristics The STM-4 (4 VC-4 into 1 STM-4) and VC-4-4c (1 VC-4-4c into 1 STM-4) SDH leased line provide a bidirectional and symmetrical leased line connection of SDH virtual containers, i.e. VC-4 and VC-4-4c, which are transferred transparently throughout the Proximus network, except the N1 bytes. Signals transmitted across the SDH leased line connections, are subject to restrictions and to impairments such as transfer delay, jitter, wander, etc. This paragraph defines the technical specifications for the bidirectional and symmetrical leased line connections of SDH virtual containers VC-4 and VC-4-4c. 2.1. Common characteristics of STM-4 (4 VC-4 into 1 STM-4) and VC-4-4c (1 VC-4-4c into 1 STM-4) leased line connections 2.1.1. Tolerance of VC timing The SDH leased line connection shall carry the customer timing with a tolerance of 20 ppm (G.783). 2.1.2. Transfer delay for VC-4 The one way end-to-end delay of the SDH leased line is less than (10 + 0,005G) ms, where G is the length of the optical fibres in kilometers. If this length is unknown, the one way end-to-end delay of the SDH leased line is less than (10 + 0,01G) ms, where G is the geographical distance in kilometers. 2.1.3. Transfer delay for VC-4-4c The one way end-to-end delay will be less than 250 ms. 2.1.4. Jitter The SDH leased line connection shall operate as specified in this document when the jitter at the leased line input is within the limits given in paragraph 3 ("Network interface presentation"). Page 4

2.2. Specific characteristics of a STM-4 (4VC-4 into 1 STM-4) leased line connection 2.2.1. Information transfer susceptance The STM-4 (4VC-4 into 1 STM-4) leased line connection shall be capable of transferring transparently from 1 to 4 complete bi-directional VC-4 except the N1-byte, provided that the VC-4 is generated according to the specifications mentioned in paragraph 4 ("terminal equipment"). The structure of a VC-4 is shown in figure 2. The bytes of a VC-4 are transmitted with a frequency of 8 khz; i.e. the frame length is 125 s. Figure 2 Note: the content of the B3 byte may change at Proximus tandem connection monitoring processes; however, the integrity of B3 parity information is maintained through the VC-4 leased line connection. An AU-4-AIS shall occur at the far end output of the VC-4 leased line connection when a defect occurs along the SDH leased line connection or at the leased line input. [AU-4-AIS is a STM-N signal in which the entire capacity of an Administrative Unit 4 (AU-4) is set to logic "1".] 2.2.2. Performance objectives The error performance level of a VC-4 leased line connection is specified in terms of errored seconds, severely errored seconds and background block errors; these performance parameters are as those defined in ITU-T Recommendation G.826. Page 5

2.3. Specific characteristics of a VC-4-4c (1 VC-4-4c into 1 STM-4) leased line connection 2.3.1. Information transfer susceptance The VC-4-4c (1 VC-4-4c into 1 STM-4) leased line connection shall be capable of transferring transparently 1 complete bi-directional VC-4-4c except the N1-bytes, provided that the VC-4-4c is generated according to the specifications mentioned in paragraph 4 ("terminal equipment"). The structure of a VC-4-4c is shown in figure 3. The bytes of a VC-4-4c are transmitted with a frequency of 8 khz; i.e. the frame length is 125 s. In the figure 3, N=4, X=4. N 270 bytes N 9 N 261 bytes STM-N 3 RSOH 1 AU-n PTRs VC-4-Xc 5 MSOH J1 B3 C2 G1 F2 H4 F3 K3 N1 Fixed stuff C-4-Xc 1 X-1 X 260 X 261 bytes T1518230-95 PTR Pointer Figure 3 Note: the content of the B3 byte may change at Proximus tandem connection monitoring processes; however, the integrity of B3 parity information is maintained through the VC-4-4c leased line connection. An AU-4-4c-AIS shall occur at the far end output of the VC-4-4c leased line connection when a defect occurs along the SDH leased line connection or at the leased line input. [AU-4-4c-AIS is a STM-N signal in which the entire capacity of a AU-4-4c is set to logic "1".] Page 6

2.3.2. Performance objectives The error performance level of a VC-4-4c leased line connection is specified in terms of errored seconds, severely errored seconds and background block errors; these performance parameters are as those defined in ITU-T Recommendation G.826.Network interface presentation. Page 7

3. The NTP (STM-4 interface) The SDH leased line connection is presented to the customer via interfaces at the Proximus Network Termination Points (NTP). This paragraph specifies the NTP technical characteristics; it defines its specifications for the physical section layer, the regenerator & multiplex section layers, and the SDH path layers. In principle, the NTP of the SDH leased line will be provided with a STM-4 interface, complying with the ITU-T Recommendations G.707 and G.783. 3.1. Physical section layers The NTP of the SDH leased line shall be provided with one STM-4 optical interface. 3.1.1. STM-4 optical interface The optical characteristics of the SDH leased line NTP, equipped with a STM-4 optical interface, are in accordance with ITU-T Recommendation G.957; this SDH leased line NTP interface is designed for operation on single-mode optical fibres. The jitter and wander tolerance of the SDH leased line input port, as well as the output jitter and wander generation at the NTP are in accordance with ITU-T Recommendations G.825 & G.783. The SDH leased line NTP, equipped with an optical STM-4 interface, shall be provided with two optical sockets, one each for transmit and receive. The STM-4 boards are connected to the optical fibre. This fibre is terminated onto an optical distribution frame (OSDF, OMDF or cable head). The optical connectors that have to be mounted on the fibre cord relaying the optical distribution frame are of the type optoclip 2. The Optoclip 2 connectors have the following characteristics: - attenuation (25 C) : - Less than to 0.3 db. - Mean value (measurement on more than 10 samples): < 0.25 db. - After 200 connections/disconnections (15 <T<35 ): < 0.4 db and mean value (measurement on more than 10 samples): < 0.35 db. - Return loss : - More than 50 db. - Mean value (measurement on more than 10 samples): more than 54 db. - Thermal behaviour : - Variation in attenuation between -20 C and 50 C: less than 0.004 db/ C. - Mean value (measurement on more than 10 samples): < 0.003 db/ C. Page 8

3.2. STM-4 regenerator and multiplex section layers As the STM-4 signal of the SDH leased line network interface complies also with ITU-T Recommendation G.707, regenerator and multiplex Section OverHead (SOH) information is added to the customer's information payload to create the STM-4 signal. The rows 1-3 of the SOH are designated as Regenerator Section OverHead (RSOH) while rows 5-9 are designated to be Multiplex Section OverHead (MSOH). This is illustrated in figure 4. The definitions of the SOH bytes (such as A1, A2, JO,...) are mentioned in ITU-T Recommendation G.707. Currently, the unmarked bytes in the SOH of figure 4, are undefined. 36 bytes A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 J0 Z0 Z0 Z*0 * ** * * * * * * * B1 E1 F1 RSOH D1 D2 D3 Administrative Unit pointer(s) 9 rows B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 K1 D4 D5 D6 K2 D7 D8 D9 MSOH D10 D11 D12 S1 M1 E2 T1518310-95 Bytes reserved for national use * Unscrambled bytes. Therefore care should be taken with their content NOTE - All unmarked bytes are reserved for future international standardization (for media dependent, additional national use and other purposes). Figure 4 The unscrambled bytes of figure 4 can not be taken with their content but must be filled by "1" and "0" in alternance. Regarding the SOH bytes of the SDH leased line network interface, an overview of their functionalities is given in table 1. Just to be clear, the following definitions apply: required: these signals at the interface shall contain valid information as defined by ITU-T Recommendation G.707. optional: valid information may or may not be present in these signals; as a consequence, the use of these functions shall be mutually agreed by the customer and Proximus. not applicable: this function is not defined at the interface; as a consequence, the customer's terminal and the SDH leased line NTP have to be capable of functioning properly with an incoming STM-4 signal programmed with this "undefined" SOH byte. Page 9

SOH-byte A1-A2 JO B1 E1, E2 F1 D1-D12 B2 K1 & K2(bits 1-5) K2(bits 6-8) S1 (bits 5-8) M1 other bytes functionality requirement required optional required not applicable not applicable not applicable required not applicable required required optional not applicable Remarks By mutual agreement between Proximus and the customer a Section Access Point Identifier may be used, conform to ITU-T Recommendation G.707. Required if APS (MSP) is provided MS-RDI is used for MS-FERF and MS-AIS. Table 1 3.3. Path layer functions The path layer forms the end-to-end connection of the SDH leased line. Two types of VCs are offered by the Proximus STM-4 and VC-4-4c leased line services, namely: VC-4, and VC-4-4c. The formats of these VCs are defined in ITU-T Recommendation G.707. Each VC-n includes a payload and a path overhead (POH). Please note that the path overhead of a VC-n, transmitted across the SDH leased line connection, has to be generated and terminated by the customer's terminal equipment. The Proximus SDH leased line shall transport these virtual containers transparently, except the network operator byte N1: The N1-byte could be used by Proximus to determine the quality of the received and transmitted VC-4 path signals. The content of the B3-byte may change at the Proximus tandem connection monitoring processes; however, the integrity of the parity information of the B3-byte will be maintained through the Proximus SDH leased line. 3.4. Safety The SDH leased line NTP complies with the requirements for accessible parts of a SELV circuit (in accordance with EN 60950). 3.5. ElectroMagnetic Compatibility (EMC) The NTP complies with the EMC requirements which are imposed under the EMC Directive (89/336/EEC). Page 10

3.6. TU/VC numbering scheme The numbering scheme must be compliant to G.707. The customer and Proximus have to use the above mentioned numbering scheme for his VC-n address, which has to be communicated to Proximus. By doing so, Proximus will be able to offer the customer an enhanced service for his STM-4 and VC-4-4c leased line services. Page 11

4. Terminal equipment The technical characteristics of the customer's terminal interface have to be in line with the relevant ETSI and ITU-T specifications and recommendations. At the NTP the customer shall provide Proximus with a grounding connection point. This grounding connection point should be easily accessible, located near the NTP, and shall enable Proximus to attach a 4 mm 2 (minimum section) ground cable with lug, bolt and washer. The characteristics of the 1grounding connection point provided by the customer must be conform to article 69 of the actual RGIE ; this grounding point shall have a resistance value not exceeding 30 Ohms. 1 RGIE: Réglement Général des Installations Electriques Page 12

ANNEX 1 Abbreviations For the purpose of this document, the following abbreviations apply: AIS AU-n AU-4-AIS BBE BIP-N EMC ES ETS ETS I ITU-T MS-AIS MS-FERF MS-RDI MSOH NTP PDH POH Ppm RGI E RSOH SDH SELV SES SOH STM-N TUG-m TU-m TU-m-AIS VC-n Alarm Indication Signal. Administrative Unit, level n. Administrative Unit (level 4) Alarm Indication Signal. Background Block Errors. Bit Interleaved Parity, width N. ElectroMagnetic Compatibility. Errored Second. European Telecommunication Standard. European Telecommunications Standards Institute. International Telecommunication Union. Multiplex Section Alarm Indication Signal. Multiplex Section Far End Receive Failure. Multiplex Section Remote Defect Indication. Multiplex Section OverHead. Network Termination Point. Plesiochronous Digital Hierarchy. Path Overhead. Parts per million. Réglement Général des Installations Electriques Regenerator Section OverHead. Synchronous Digital Hierarchy. Safety Extra Low Voltage. Severely Errored Second. Section Overhead. Synchronous Transport Module, level N. Tributary Unit Group, level m. Tributary Unit, level m. Tributary Unit, level m, Alarm Indication Signal. Virtual Container, level n. Page 13

ANNEX 2 Reference list of standards G.703 G.707 G.783 G.825 G.826 G.957 prets 300 147 ETS 300 166 ETS 300 417-1-1 ETS 300 417-2-1 ETS 300 417-3-1 ETS 300 417-4-1 IEC 169-13 IEC 874-13 EN 60950 (11/2001) Physical/electrical characteristics of hierarchical digital interfaces. (3/1996) Network node interface for the synchronous digital hierarchy (SDH). (3/2001) Characteristics of synchronous digital hierarchy (SDH) equipment functional blocks. (3/2000) The control of jitter and wander within digital networks which are based on the synchronous digital hierarchy (SDH). (2/1999 & 7/2001) Error performance parameters and objectives for international constant bit rate digital paths at or above the primary rate. (6/1999) Optical interfaces for equipment and systems relating to the synchronous digital hierarchy (SDH). (11/96) Transmission and Multiplexing (TM); Synchronous Digital Hierarchy (SDH); Multiplexing structure. (1993) Transmission and Multiplexing (TM); Physical and electrical characteristics of hierarchical digital interfaces for equipment using the 2048kbit/s based plesiochronous or synchronous digital hierarchies. (1996) Transmission and Multiplexing (TM); Generic functional requirements for Synchronous Digital Hierarchy (SDH) equipment, part 1: Generic processes and performance. (1996) Transmission and Multiplexing (TM); Generic functional requirements for Synchronous Digital Hierarchy (SDH) equipment, part 2 : Physical section layer functions. (1997) Transmission and Multiplexing (TM); Generic requirements of transport functionality of equipment; Part 3-1: Synchronous Transport Module-N (STM-N) regenerator and multiplex section layer functions. (1997) Transmission and Multiplexing (TM); Generic requirements of transport functionality of equipment; Part 4-1: Synchronous Digital Hierarchy (SDH) path layer functions. (1976) Radio frequency connectors - part 13; R.F. coaxial connectors with inner diameter of outer conductoe 5.6 mm - Characteristic impedance 75 ohms (Type 1.6/5.6) (1993) Connectors for optical fibres and cables - part 13: sectional specification for fibre optic connector - type CF08. (1992) Safety of information technology equipment including electrical equipment. Page 14