icam7000s SERIES HARDWARE GUIDE Packing List CONTACTLESS CARD READER RECESS MOUNT (Optional) ISO/ANSI COMPLIANT EASY INSTALLATION What s in the Box

Similar documents
Zodiac FR100 TM INSTALLATION MANUAL

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

VC 220 Dome WDR Day/Night PoE Network Camera

Nearus USB2.0 Camera Manual NU-350-USB2PTZ-B

Installation & User Manual

smartentry Wireless Video Doorphone User Manual

GV-IPCam H.264. Hardware Manual. Vandal Proof IP Dome Target Vandal Proof IP Dome

Network Camera. Installation Manual Before operating the unit, please read this manual thoroughly and retain it for future reference.

Quick Start Guide. GV-Video Server. 1 Introduction. Packing List

Installation & User Manual V2.08

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3

Quick Start Guide. GV-CS1320 Camera Access Controller

Quick Start Guide. GV-Video Server

Quick Start Guide. GV-Video Server

Yeastar S100 VoIP PBX

2M Outdoor Motorized Bullet Camera

ACCESS CONTROL SYSTEM

GV-Card Reader. User s Manual

7 S-Series HMI W07FA3S-PCM1AC-PoE W07FA3S-PCM1-PoE. Quick Start Guide V1.0

Digital Keypad Introduction

MS-7000: SuperStar Reader

GV-IPCam H.264. Hardware Manual. Bullet Camera Ultra Bullet Camera Target Bullet Camera

ZAVIO Outdoor IR Mini Dome. Quick Installation Guide

Sarix Professional IMP Series 3.75 Indoor Dome. Quick Start Guide IMP121-1IS IMP221-1IS IMP321-1IS IMP521-1IS C2291M-B-EN (12/16)

UC-2000 Installation Manual Unicorn Computers Technology Limited

Yeastar S300 VoIP PBX. Installation Guide

Next Gen Sarix Enhanced IXE Series Box Cameras

EP/2 Installation Instructions

Full HD WDR Mini Dome IP Camera

IP Speaker System. Users Guide

Hardware Installation

Roughneck V920D Series Camera Domes XX Quick Guide

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

INSTRUCTION/INSTALLATION SHEET lyriq High Performance Keypad Volume Control With IR

BioEnable Iris Recognition Solutions

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

USER MANUAL MINI WILDLIFE CAMERA

CR3000 Copy Reader. Installation Guide

Two-door Access Controller

TEL: / FAX:

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

ZAVIO Indoor Box Camera. Quick Installation Guide

VITEK VTD-TND4RMS FEATURES

Outdoor Motorized Dome. Quick Installation Guide 86085A

User Guide. V and V Series Network Panoramic Cameras XX Vicon Industries Inc. Tel: ) Fax:

Click Save to return to the main Setup screen.

EN - 1. Warning Before Installation. Package Contents. Refer to your user s manual for the operating temperature.

GENERAL QUICK START GUIDE

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

MGate 5111 Quick Installation Guide

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

Installing the Camera

INNOMETRIKS INC. Rhino Quick Start Guide

F7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions

EL-ST100 KEYPAD CONTROLLER

Contents Installation Instructions 3 Installation Diagrams System Overview Wiring Diagrams Network Diagrams

GV-IPCam H.264. Hardware Manual. Bullet Camera Ultra Bullet Camera Target Bullet Camera

MS-5000: MiniStar Reader

Quick Start Guide. 2MP 4X PTZ IP Camera O2P4X

DOLXFD1000B. Waterproof Access Control/Reader

VDC-HD3500/HD3500P. Introduction1/16

2M IR Mini Dome Quick Installation Guide

Industrial Serial Device Server

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

GV-IPCam H.264. Hardware Manual. Cube Camera Mini Fixed Dome Mini Fixed Rugged Dome Target Mini Fixed Dome Target Mini Fixed Rugged Dome

INSTRUCTION/INSTALLATION SHEET lyriq Studio High Performance Keypad

FACIAL RECOGNITION TERMINAL SYSTEM

RТTH DUAL ROOM SWITCH

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

RXTP ROOM TEMPERATURE

Operation manual For NG BIOSINGLE Version 1.1

UR72 & UR75 Industrial Cellular Router

Quick Start Guide. Reolink Argus 2. Technical Support QG2_A. For more troubleshooting, please go to FAQs on our website:

The Nureva Span ideation system. Installation guide. Single panoramic system

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-74DL Master Room Controller. P/N: Rev 5

DEFLECTION AND TWIST MEASUREMENT SYSTEM (DTMS) Model 47

Full HD IP Vandal Dome Camera

USER MANUAL. RC-76R/RC-78R Room Controllers MODEL: P/N: Rev 2

REX F-0-9 Standalone or Access Controller

Model HM-535 Power Supply Installation and Service Instructions

E92. Hardware User s Manual. 3MP Indoor Mini Dome with Basic WDR, Fixed lens. (PoE) Ver. 2013/02/04

RFT1000 reader in RACS 5. User Manual

UR51 Industrial Cellular Router

Mobile Access, TimeTec Smart Flap Turnstile FTS 2100B & 2200B Installation Manual

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Warning Before Installation. Package Contents EN - 1. Refer to your user s manual for the operating temperature.

GV-IPCamera. Quick Start Guide. Vandal Proof IP Dome Target Vandal Proof IP Dome

USER MANUAL. RC-74DL Master Room Controller MODEL: P/N: Rev 4

700TSU INSTALLATION MANUAL

AMP20. User Manual.

Industrial PoE Plus Outdoor IR IP Camera ICA-2250VT

SLIMBAT2 wireless photocell MANUAL

QUICK START GUIDE. OE-C97512 Fisheye IP Camera CAMERA. Waterproof Cable

4" AMPLIFIED RECESSED CEILING SPEAKERS 8" AMPLIFIED RECESSED CEILING SPEAKERS

IQeye 7 Series Megapixel Indoor IP Camera. Quick Install Guide

Two Door Controller GEN-045

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers. P/N: Rev 5

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Installation Instructions (KF-2000)

Omega 4K / UHD Three-Input Switcher for HDMI and USB-C with HDBaseT and HDMI Outputs

Transcription:

icam7000s SERIES HARDWARE GUIDE ADVANCED MULTIFACTOR BIOMETRIC IRIS READER VERSION 1.0 icam7000s-t (Titanium Color) icam7000s-b (Black Color) DUAL IRIS ISO/ANSI COMPLIANT FACE CAMERA EASY INSTALLATION CONTACTLESS CARD READER RECESS MOUNT (Optional) Fully automatic dual iris capture Simple non-intrusive, non-contact user interface Integrated megapixel face camera with LED flash ISO/ANSI compliant iris and face images Integrated contactless smart card reader [optional] Surface mount plate included; Recess mounting kit [optional] Packing List What s in the Box icam7 series Hardware Guide L wrench Required Equipment (not included) Power Source 12-24 VDC +/- 10% / Minimum 24W (12VDC @ 2AMPS) (Measured at icam unit) Uninterruptable Power Supply (strongly recommended) Network Ethernet Wiring CAT5e Ethernet Cabling (or better) Ethernet Switch Software Software required depending on Application (See www.irisid.com for details) icam7000s-b / icam7000s-t icam7 series Hardware Guide L wrench

Hardware Information Camera Unit Alignment Guide Mirror Face Camera Screw Cap CCTV Camera (optional) Front View Up / Down Tilt Buttons Face Camera Flash Screw Cap Proximity Sensor Speaker Interface Panel Status LED Bottom View Cable Channel Tripod Socket (1/4-20 (1/4 diameter, 20 threads per inch)) Knock-out Rear View Desktop Stand Hole Surface Mounting Screw Hole Tamper Switch Gang Box Screw Hole 2 Installation Plate

Hardware Information Inside Installation Plate Screw RTC Battery Tamper Switch Wiring Legend Guide Input / Output Connections Power On/Off Switch Power LED Ethernet Connection / USB 2.0 (Bottom) Power Connection External GPIO RS232 / RS485 / RS422 Serial External Speaker Jack Factory Default Button Relay Output Wiegand Output / Input 3

Installation Guidelines 1. Recommended Mounting Information Bottom of Mirror 7.01 (178mm) 2.52 (64mm) 61 (155cm) 54.3 (138cm) NOTE 8.31 (211mm) This is based on the assumption that users average height is 5 7 (170cm) Floor The recommended mounting height for the icam7 series is 138cm (54.3inches) from the floor to the bottom of the unit. This mounting height can be adjusted to accommodate the height of the average user at the installed location. High amounts of ambient light must be avoided. Intense light sources such as sunlight or halogen lamps may reduce the image capture performance of the icam which may result in an increased failure to acquire rate. The icam was designed for indoor use only. This device is not weatherproof and must not be exposed to precipitation or extreme temperatures. If it is required to use this product in an outdoor or extreme environment, a 3rd Party enclosure may be used to protect the unit from exposure to dust, moisture, and extreme temperatures. See www.irisid.com - Support & Service for more information. Installation in a extreme environment without proper protection may cause permanent damage and void the warranty. 2. General Wiring Requirements The icam7 series requires at least the following wires: Ethernet network wiring to connect with the network switch for communication. NOTE For systems consisting of only the icam and a computer, an Ethernet cross-over cable may be used. 4 IMPORTANT: IT IS RECOMMENDED THAT THE IRISACCESS SYSTEM BE PLACED ON A PRIVATE NETWORK SEPARATE FROM GENERAL CORPORATE OR PUBLIC ACCESS. SYSTEM PERFORMANCE AND STABILITY MAY BE AFFECTED DEPENDING ON AMOUNT OF GENERAL NETWORK TRAFFIC. Power Adapter: The optional power adapter (icam7-pwr) can be used as the power source of the icam used for enrollment or other non-installed applications. The wires of the adapter should not be extended. If the power source is beyond the length of the power adapter then an external power source and wiring should be used. Be sure to observe the polarity of the adapter wires to the power screw terminals on the icam main board. OR Power and Wiring: For permanent installation it is recommended to use an external power supply and wiring. Power Supply: 12-24VDC +/- 10% - Minimum 24 Watts (24VDC @ 1AMP). Power Wiring: The recommended wire gauge for the ICU power is 18AWG (1.0 mm) wire. NOTE Use of a stable power supply and proper gauge wire is required. The wire length voltage drop must be accounted for in order to maintain the correct power at the ICU7000-2 unit. For wire lengths over 30 feet (9 meters) or if thinner gauge wire is being used (more than 18AWG) then it is required that a 24VDC power supply be used to overcome the wire length voltage drop. A 24VDC supply with 18AWG (1.0 mm) wire will allow for a distance of up to 200 feet (61 meters).

IMPORTANT: IT IS RECOMMENDED TO SUPPLY THE CORRECT AMOUNT OF POWER TO THIS UNIT. AN OVER OR UNDER VOLTAGE APPLIED TO THIS PRODUCT MAY CAUSE PERMANENT DAMAGE AND VOID THE WARRANTY. icam Installation icam7 series Mounting & Stand Solutions The icam7 series unit can be fitted to a surface mount (available out-of-the-box), recess mount (with optional recess mounting kit), or optional desktop stand. Surface Mounting The icam can be surface mounted with standard equipment provided with the contents of your unit. Review the following procedure for instruction on how to surface mount your icam7 series unit. 1 Open each cap at both sides of unit, and loosen the captive screws (with included L wrench) to release the interface panel. (Left : MIC / Screw Cap. Right : USB Connector / Screw Cap) 2 After opening the interface panel, loosen the screw. Unscrew the installation plate screw to separate from the installation plate. 3 Separate the installation plate by sliding the plate downward. Cover Rear Installation Plate 5

4 Place the installation plate on the desired wall and screw into wall. Feed any needed wiring through the installation plate hole (i.e.: Power, Ethernet, etc). Attach the installation plate to the wall surface using the appropriate fastener (recommended #10 screws) and anchors for the wall material. Another option is to mount and fasten the installation plate to a previously installed electrical gang box. Surface Mount Hole Marking Installation Plate OR Gang Box Mount Installation Plate 5 Slide the icam7 series into the installation plate and fasten the installation plate with a screw. 6

6 Remove protective film from RTC battery. OFF ON OFF ON Power Supply Connector Ethernet Cable Power on 7 Before wiring unit, confirm the power is in the off position. Route and connect the Power and Ethernet wires to icam7 series. NOTE If connecting any other wiring such as Wiegand, GPI/O to the icam, review the following section Wire Connection Details before closing interface panel and fastening screws. OFF ON 8 Turn on power source and switch the power switch of the icam7 series unit to the ON position. 9 After wiring the unit and switching it to the ON position, close the interface panel and fasten the screws. (with screw caps placed back into closed position). 7

Wire Connection Details A B C D E F A External GPIO GPIO3 and 4 can be used to control the tilt position of the tilt unit of an icam7 series. Use GPIO3 and for up tilting. Use GPIO4 and for down tilting. GPIO Specifications: For output, the GPIO can provide 5VDC @ 20mA. For Input, the GPIO is selectable between active High & active Low. Assignment of GPIO is handled through Software External Tilt GPIO3 GROUND GPIO4 GROUND Up Down External GPIO GPIO1 GPIO2 GPIO3 GPIO4 8

B RS232 Output RS232 serial communication port for connection with an access panel or to other computer equipment. When configured, the Card ID associated with the user is output from the RS232 output port upon a successful identification. TXD RXD To RS232 port of computer or access system RS232 Output 12VDC (Max 0.3A) 12VDC (Max 0.3A) 12VDC (Max 0.3A) TXD RXD RS485 Output RS485 serial communication port for connection with an access panel or to other computer equipment. When configured, the Card ID associated with the user is output from the RS485 output port upon a successful identification. TX/RX+ TX/RX- To RS485 port of computer or access system RS485 Output TX/RX+ TX/RX- RS422 Output RS422 serial communication port for connection with an access panel or to other computer equipment. When configured, the Card ID associated with the user is output from the RS422 output port upon a successful identification. TX+ RX+ TX- RX- To RS422port of computer or access system RS422 Output TX+ RX+ TX- RX- 9

C Relay Output IMPORTANT: ONLY KNOWLEDGEABLE PROFESSIONAL INSTALLERS SHOULD BE USED TO INSTALL ALL ELECTRONIC ENTRY/EXIT LOCKING DEVICES. DIRECT CONNECTION OF ELECTRONIC ENTRY/EXIT LOCKING DEVICES SHOULDN T BE MADE FROM THE RELAY OUTPUTS ON THE ICAM. IT IS THE RESPONSIBILITY OF THE INSTALLER TO ASSURE THAT THE INSTALLATION IS PERFORMED IN ACCORDANCE WITH ALL COUNTRY/STATE/ LOCAL FIRE AND SAFETY REGULATIONS AND THAT ANY 3RD PARTY PRODUCTS USED WILL NOT CREATE A HAZARD. Two independent dry contact relays. The purpose and the duration of the relays are defined by the controlling software. Typically, Relay_1 (NC_1, COM_1, NO_1) is triggered upon user acceptance (access granted). The diagram shows Relay_1 connected to indicators which changes from Red to Green for an accepted user. Relay_2 (NC_2, COM_2, NO_2) is typically used to indicate icam tamper. In this diagram the relay is activated when the icam tamper switch is triggered. The maximum electrical rating for the relay is 3A at 24VDC. NC_1 COM_1 NO_1 NC_2 COM_2 NO_2 Relay Output LIGHT POWER SUPPLY RED GREEN ALARM SYSTEM 24 HOUR ZONE D Wiegand Output The Wiegand Output from the icam7 series camera unit can be used with 3rd party devices capable of receiving Wiegand data. This Wiegand output emulates a typical Access Control Card Reader. Configuration of this output is provided through software. See the associated image for general wiring of Wiegand Output to an Access Control Panel. Wiegand Specifications: Wiegand output uses 3 wire interface (Data0, Data1, and Ground), Maximum wire length from icam to Access Control Panel is 500feet (152m). NC DATA_0 DATA_1 Wiegand Output Card Reader Interface GROUND DATA_1 DATA_0 ACCESS CONTROL PANEL 10

E Wiegand Input Wiegand input is available on the icam for connection from 3rd party proximity card readers. This connection can provide 12VDC and a maximum 300mA current to a proximity card reader. 12VDC (Max 0.3A) DATA_0 DATA_1 Wiegand Intput External Prox Card Reader 12VDC DATA_0 DATA_1 GROUND F External Speaker Out Allows for connection of an external amplified speaker. This port provides mono or stereo (single channel) audio of voice prompts and other unit sounds. Both the internal and external speakers can operate concurrently. Ground Mono Signal To amplified speaker 3.5mm Ground Stereo Left signal To amplified speaker Right signal 3.5mm 11

icam Configuration The icam7 Series camera contains a configuration interface called the icam Configuration. This configuration interface allows the installer to setup the icam s IP Address, IrisServer connection, and other configuration options. How to access the icam Configuration interface From a PC with an internet browser connected to the network (that the icam7 series unit is connected to), type the IP address of the icam. For example, if the IP address of an icam is 192.168.5.100 (default IP), you would access the configuration web interface by typing http://192.168.5.100 from an internet browser. To login, the User ID required when prompted is icam7000. The Password is iris7000. The system is case sensitive when entering in your login credentials. Once you have connected to the icam Configuration Interface - settings, information, and options become available to further configure your system. Additional documentation for setup and configuration can be found at: http://www.irisid.com/productdocumentation 12

How to Operate 11~15 (28-38cm) Tilt down -25 Degrees Read distance 14inches away Tilt up +35 Degrees Read distance 14inches The on-unit up/down tilt buttons can be used to adjust the tilt angle; or an external mounted switch can be wired to control up/down tilt via GPI. icam activates when user approaches or when card is presented. Picture capture range is 11~15 inches (28-38cm) away. Self or auto/set height adjustment. Placing dot over the bridge of nose, easily helps alignment. Orange turns to green when user is at correct distance. Visual indication is amplified with friendly audio prompts. Right and left irides are acquired. A face picture can also be captured. Green dot = In range Orange dot = Out of range 13

Restoring The Unit to Factory Default Factory Default Button The Factory Default Button can be used to restore the settings of the icam7 Series to factory default. This button is located inside of the unit next to the power switch (see image), and can be used in two different ways: Factory Default Button Function Reset IP Address and Login Credentials Reset all settings and reload software Procedure Unit Power is ON Press and Hold the Factory Default Button for more than 3 seconds. Unit will beep when the default process has started. The icam IP Address will be reset to 192.168.5.100, The Username to icam7000, and the password to iris7000. Power Unit OFF Press and Hold the Factory Default Button (FDB) While still holding the FDB, Turn ON the unit power Keep the FDB held in for at least 10 seconds. Stop holding the FDB Do not turn off the power to the unit or remove the network connection for at least 10 minutes (the unit will reboot several times on its own during the software reload process). When complete the icam will have reloaded the software and reset IP Addresses and log-in creditenials to the defaults. 14

Memo Serial Number: Unit IP Address: Installation Date: Option 3 Iris Server IP: Option 3 Security ID: Note: 15

General Information The icam7 series multifactor iris biometric reader contains a high-speed multi-sensor optical system which provides ISO compliant iris images. The icam7 series also contains a color face camera, an intuitive user interface, a built-in iris biometric template creation and matching processor, and an optional integrated card reader. Input and Output interfaces of the icam7 series units include Wiegand, Serial, and Relay. Dimension (W x H x D) Weight Power Input / Consumtion Status LED Iris Operating Range Indicator Voice Indication Iris Capture Range Flash Face Image Camera Relays x 2 Operating Temperature Storage Temperature Humidity Iris & Face Camera Rotation Angle Communications Inputs / Outputs Equipment Supplied with icam7 series 7.01 x 8.31 x 2.52 (178mm x 211mm x 64mm) 3.3lbs (1.5kg) 12-24VDC, 2.0 Amps @ 12VDC / 24W Multi Color - Red, Green, Blue, Amber for status and alarm indication Dual Color - Orange (out of range), Green (in range) English and Korean standard, other languages available 11 ~15 (28cm ~ 38cm) High output LED flash for face capture Face camera CMOS - 5MP Control for user defined operations 32 F~113 F (0 C~45 C) -4 F~203 F (-20 C~95 C) Up to 90% non-condensing +35 /-25 Ethernet (LAN, WAN), RS232 / RS485 / RS422 Embedded Card Reader (Optional), Wiegand In, Wiegand Out, Dry Contact Relay x 2, Programmable GPIO x 4 Instruction Manual - Hardware Guide Technical Support Additional information and technical assistance is available on the Iris ID Systems support web site at www.irisid.com. Click on Support & Service then Technical Support. formerly Iris ID Systems, Inc. 8 Clarke Drive, Cranbury, NJ 08512, USA Tel. 609-819-IRIS(4747) Fax. 609-819-4736 www.irisid.com 2016 Iris ID, Inc. All rights reserved. Design and specification subject to change without notice. Printed in Korea