Modular I/O Solutions Designed for Open Network Systems

Similar documents
RZXS CONFIGURATOR. (model: RZMSCFG) Users Manual. Contents 1. GENERAL...2

MODEL: MSRPAC PC Recorder Series

Model R5H-RS PC CONFIGURATOR (model: R5HRSCFG)

Model M3LR PC CONFIGURATOR (model: M3LRCON)

MODEL: R3. Remote I/O R3 Series

Model B6U / B6U-B PC CONFIGURATOR (model: B6UCON)

MODEL: MSR2K-V6. PC Recorder Series

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

R7X CONFIGURATOR. (model: R7CON) Users Manual , Minamitsumori, Nishinari-ku, Osaka JAPAN Tel: Fax:

No.170. R7L Series I/O Type Addition. February 2009 I N S I D E

MODEL: 73VR3100. Paperless Recording System

R6-NC1 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL CC-Link INTERFACE MODULE MODEL. (CC-Link Ver.1.10; for 16-point analog signals)

Remote I/O Modules EH-RIO2 Series

DISCONTINUED MODEL Replaced with Model MSRPAC-2005

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

LAUREL ELECTRONICS, INC.

Veeder-Root brand Series C628 Rate Meter (C628-4XXX)

Power Transducers. Measuring most electrical parameters

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

DISCONTINUED MODEL Replaced with Model MSRPAC-2006

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

M3S Series Super-space-saving Signal Conditioners. PC CONFIGURATOR SOFTWARE Model: M3SCFG. Users Manual

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

MTS-2000 USER S MANUAL

MODEL: R1M-GH. PC Recorders R1M Series

Max. I/O units. consumption

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Drawings. Model UT35A Digital Indicating Controller (UT35A-NNN-xx-xx/x) SD 05P01D41-05EN. External Dimensions. Panel Cutout Dimensions.

Piccola Smart Box Member of Modul MAS family

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

APPLICATION. Data acquisition Remote I/O I/O extension DESCRIPTION CONSTRUCTION

Series S628 AC Volts/Amps (S628-3XXX) Veeder-Root brand. Technical Manual

LAUREL ELECTRONICS, INC.

Digital Lighting Systems, Inc.

R3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

V E2B Snap-in I/O Module

-Camille Bauer Div. of Absolute Process Instruments, Inc. Phone: Fax: J-1

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

PIM-Mini Pulsed Current Source Operation Manual

PCM-7140 Pulsed Current Source Operation Manual

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

PMDX-170 Slotted Optical Sensor

V E1B Snap-in I/O Module

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

DIGITAL INDICATING CONTROLLER

Photoelectric Sensor

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Photoelectric Sensor

C160 Wall-/Pipe Mounted Universal Process Indicator

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

Wall-/Pipe Mounted Universal Process Indicator

PWR. Power Module Slots

BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection)

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

SECURE/NONSECURE LED SIGN USER MANUAL

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

S800 I/O ABB Automation

IOX-4. Installation Instructions. AXS-100 I/O Expander 1. INTRODUCTION 2. SPECIFICATIONS 3. MOUNTING DE6314 1

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

Omega and Red Lion team-up!

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

Features various encoder interfaces and controls multiple analog servo drives at high speeds

Discrete I/O connected direct onto. Input and Output Function Blocks, including Flexible Function Block (FFB) for logic execution

TSD-DA28 2x8 Balanced Line Distribution Amplifier

Powered Roller Controller for DeviceNet

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

TC /100Base-T Ethernet Fiber Optic Switch User's Manual. 4 Ethernet 10/100Base-T Auto-Sensing Twisted Pair Ports with RJ-45 Connectors

73VR3000 PAPERLESS RECORDER MODEL. Paperless Recording System. (selectable input modules) MODEL & SUFFIX CODE SELECTION 73VR3000 R3 TYPE

-Camille Bauer. Phone: Fax: American Way Libertyville, IL USA. Application Challenges! Sig. Cond.

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

MODEL: 73VR1100. [3] OPTIONS blank: none /Q: With options (specify the specification) Paperless Recording System

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

Veeder-Root brand Series S628 Strain Gauge (S628-6XXX)

iologik 4000 Series (M) Modules

VariTrans P Standard-Signal Isolators

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

SIGNAL CONVERTERS ELECTRONIC INSTRUMENTATION FOR INDUSTRY. Small catalogue. Tel. (+34)

M-System s. 17 years of successful sales, 480,000 total units sold! selectable. Mixed Signal. Mixed Signal. Compact, Mixed Signal

CJ1W-PTS/PDC/PH41U/AD04U

DLS-E2 TELEMETERING UNIT BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (16 contact inputs & 16 open collector outputs)

Solid State Relays with Failure Detection Function

Energy Management Modular Energy meters Type EM2-96

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

Z-PC Line REMOTE I/O SYSTEM. Cost-effective & easy to manage TCP-IP

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Transcription:

M-SYSTEM WARRANTY. What is covered. M-System Co., Ltd. ( M-System ) warrants, only to the original purchaser of new M-System products purchased directly from M- System, or from M-System s authorized distributors or resellers, for its own use not for resale, that the M-System products shall be free from defects in materials and workmanship and shall conform to the specifications set forth in the product catalogue applicable to the M-System products for the Warranty Period (see Paragraph below for the Warranty Period of each product). THE ABOVE WARRANTY IS THE ONLY WARRANTY APPLICABLE TO THE M-SYSTEM PRODUCTS AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIM- ITED TO, ALL IMPLIED WARRANTIES OF MERANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE.. What is not covered. This warranty does not cover any M-System product which has been: () modified, altered or subjected to abuse, misuse, negligence or accident; () improperly installed or installed in conjunction with any equipment for which it was not designed; or () damaged or destroyed by disasters such as fire, flood, lightning or earthquake. In no event shall M-System be liable for any special, incidental, consequential or other damages, costs or expenses (including, but not limited to, loss of time, loss of profits, inconvenience or loss of use of any equipment). External Dimensions mm (inch) Exact dimensions differ from each type. Refer to the data sheets for detail. R Series 0 (.9) 0 (.) 0 (.09) (.) M TERMINALS T T T T T T T7 7 8 9 0 7 8 9 0 7 8 9 0. (.) 7 (.89) (.0) (.) FOR WALL MOUNT. 8 (.) (.0) dia. MTG HOLES CJC SENSOR (model: CJM) 0 (.7). (.9) [ (.)] mm wide Modular Solutions Designed for Open Network Systems REMOTE Supports DCS/ systems by expanding their flexibility and capabilities. Stand-alone distributed communicating with popular HMI software Broad offering; DC mv, V & ma, temperature, discrete signals and other sensor inputs are supported. Four product series are available to suit various applications. REMOTE. Remedies. If a defective product is returned to M-System in accordance with the procedures described below, M-System will, at its sole option and expense, either: () repair the defective product; () replace the defective product; or () refund the purchase price for the defective product paid by the purchaser. Except as otherwise provided by applicable state law, these remedies constitute the purchaser s sole and exclusive remedies and M-System s sole and exclusive obligation under this warranty.. Warranty Procedure. If the purchaser discovers a failure of the M-System products to conform to the terms of this warranty within the Warranty Period, the purchaser must promptly (and, in any event not more than 0 days after the discovery of such failure) notify the relevant party as described below either by telephone or in writing at the below address to obtain an Authorized Return (AR) number and return the defective product to the relevant party. The designated AR number should be marked on the outside of the return package and on all correspondence related to the defective product. The purchaser shall return, at purchaser s expense, defective products only upon receiving an AR number. In order to avoid processing delays, the purchaser must include: copies of the original purchase order and sales invoice; the purchaser s name, address and phone number; the model and serial numbers of the returned product; and a detailed description of the alleged defect.. Warranty Period. Signal Conditioner: months from the date of purchase. M-Rester: months from the date of purchase. Valve Actuator: 8 months from the date of shipment from M-System or months from the date of its installation, whichever comes first. Other Products: months from the date of purchase. 0 (.) (.0). (.). (.) 90 (.) (.) 7 8 9 0 7 8 9 0 7 7 8 8 9 9 0 0 A (.) 7 7 8 8 9 9 0 0 A 0 (.8) 0 (.7) 0 (.79). (.0).7 (.) [ (.0)] mm wide. (.9) MODEL R-BS0 R-BS0 R-BS0 R-BS08 R-BS0 R-BS R-BS R-BS 90 (.). (.) (.9) A (.0 ) (. ) 8 (. ) ( 8.8 ) 80 (.0) (.) 9 (.) 8 (7.) [ (.0)]. (.9) mm wide M-SYSTEM CO., LTD. --, Minamitsumori, Nishinari-ku, Osaka 7-00 JAPAN Phone: (0) 9-80 Fax: (0) 9-80 E-mail: info@m-system.co.jp subject to change without notice. R7 Series BASE MODULE, INPUT (.) MODEL A 7 (.) R-BS0, 0 R-BS08, 09 R-BS 7 (.8 ) ( 9.09 ) 79 (.9 ) (.) 8 (.7) mm wide --, Minamitsumori, Nishinari-ku, Osaka 7-00 JAPAN Tel: +8()9-80 Fax: +8()9-80 URL: www.m-system.com E-mail: info@m-system.co.jp 0 (.97) 7 7 M TERMINALS for NETWORK, POWER 0 7 8 7 8 9. (.). (.) 8 M TERMINALS. (.9) Your local representative is : EXTENSION MODULE. (.) 9 (.70) 7 (.) (.) 8 (.7) mm wide 0 (.97) 0 7 8 7 8 9. (.9) Visit us at www.m-system.com and are registered trademarks M-System Co., Ltd., registered in Japan, the United States, and other countries.. (.) 8 M TERMINALS EC-Z Rev. August 00

Hot Swappable, Fully Isolated Remote M-System s Remote is designed to support DCS/ systems by expanding their flexibility and capabilities in addition to providing all full channel-to-channel isolation. The Remote communicates directly to the and DCS via industry standard open-protocol networks. M-System s Remote also can be used as stand-alone distributed communicating with popular HMI software such as Citect, Intellution and Wonderware. The Remote can be located remotely in the field, or within an instrumentation cabinet such as test stands. The flexibility and scalability of M-System s Remote supports future system upgrades with full isolation between powercommunication- and between analog channels. Economical non-isolated analog modules are also selectable. Isolated analog modules provide high-performance signal conversion/conditioning and complete three-way plus channel-to-channel isolation. This ensures you a highly dependable system. Applications include: signal concentrator, data collection in flow and level monitoring, injection molding monitoring and control, test stands and prototyping, glass furnace temperature control, assembly line discrete ON/OFF, paint booth environment reporting, pharmaceutical processes. Broad Offering: Scalable and Flexible M-System, a specialist in signal conditioning, offers not only -0 ma / - V or discrete modules, but also temperature and other sensor inputs such as strain gauge, AC signals, pulse signals, etc. These modules can be mixed and mounted at any position on a backplane base. -position, 8-position and -position bases with single/dual channel analog modules are available for the. The is furthermore scalable from -position base, with - to -channel analog modules available. You can then take a minimum required number of modules and combine them to meet your specific system requirements. Redundant Communications: Reliable and Flexible Both R and supports optional redundant communications for mission critical applications. Dual network communication modules are optional. Additionally network interface modules can be placed without removing power. If you choose two different network protocols for the network modules, the remote s can be directly monitored by two different manufacturers systems. Reduce Downtime, Quick Installation All R and modules are field configurable via DIP Switches or via Configurator. DIP Switches configure the type, range and sensor failure modes (upscale or downscale). Communication module settings include baud rate and node address. Module replacement can be performed without programming or removing power. Simply remove the failed unit and replace with a good unit with the same DIP-Switch settings. No additional programming is required. Redundant Power for High Reliability Dual power supplies for the R and allow support for two different power sources. For example: the primary power can be supplied by 0 V or 0 VAC mains power while the secondary power module is connected to backup power from a UPS VDC system. Lower Total System Cost With its flexible and easy-to-use features, M-System s Remote ensures the toal cost reduction not only of hardware price but also of the time and additional resources such as specialized knowledge. Modular Solutions Designed for Open Network Systems Interface for Small Scale SCADA Interface for Large Scale SCADA Interface for LAN Ethernet Ethernet Gateway / Protocol Converter Field Network (Modbus, etc) Open Field Network (Modbus, etc) Open Field Network /DCS R Series R Series R Series R Series Remote Can Replace in -Based SCADA Systems System expansion can be done easiiy by directly connecting Remote and via a Field Network. The cost per channel is lower than using a. Easy system implementation without needing ladder programming M-System s wide variety of modules including programmable universal inputs are sure to meet your system requirements. Communication Module Field Network One Way Open Field Network (Modbus, etc) Network Module INTRODUCING REMOTE and other SCADA software R Series Better Way Remote Replacement for and DCS Appropriate type & numbers of modules can be chosen according to project needs. Minimization of total wiring cost through field network connectivity & remote distribution eliminating expensive point to point wires. M-System has a wide variety of modules including DC, T/C,, Potentiometer and more. CPU Panel Cable Signal Conditioner One Way Field Site A Power CPU Dual Redundant Power Supply (option) Panel Communication Module INTRODUCING REMOTE Field Network Dual Redundant Communication (option) Better Way Field Site B Signal Conditioner Power CPU Power Field Site C Field Site A Field Site B Field Site C

R7 NEW PRODUCT Compact all-in-one package Multi-channel, Mixed Signal Remote Wide selection of modules and network modules. Cost Lower Fieldbus Smaller Space Great flexibilities in number and type of signals: DC current/voltage, temperature, strain gauge, AC current/voltage, AC power, etc. Economical DC input module can handle fullyisolated points up to non-isolated points. Hot-swappable modules Dual redundant communication networks and power supplies 00 Vac isolation Palm-top size compact module can handle analog or discrete signals. The,network and power input modules are in one packege. Extension module Additional Functions Higher Integrity 7 types of open network protocols thr. analog channels per module thr. modules per node Typical Signals,, DC voltage/current, two-wire transmitter, potentiometer, strain gauge, AC power, PT/CT, pulse & discrete. Typical Output Signals DC voltage/current, totalized pulse & discrete LONWORKS discrete input or output module can be attachea to the base module. Analog and discrete signals can be mixed by combining a discrete module with an analog module. 00 Vac isolation for analog modules Fully isolated between, network and power input. Channel-to-channel isolation is also provided. Compact, Mixed Signal Remote Free combination of modules, network modules and power modules. Cost Lower R Series Fieldbus Additional Functions Smaller Higher Space Integrity Single analog module can handle fully-isolated points. Hot-swappable modules Dual redundant communication networks and power supplies 00 Vac isolation Space-saving DIN terminal block or heavy-duty screw terminal block selectable for types of open network protocols thr. analog channels per module thr. modules per node Typical Signals,, DC voltage/current, two-wire transmitter, potentiometer, CT, totalized pulse & discrete. Typical Output Signals DC voltage/current, totalized pulse & discrete Compact Size BASE MODULE Dry contact input, points NPN transistor output, points PNP transistor output, points DC voltage / ma input, points input, points input, poins DC voltage output, points DC current output, points Network Modbus DeviceNet CC-Link R7M-DA R7M-DCA R7M-DCB R7M-SV R7M-TS R7M-RS R7M-YV R7M-YS R7D-DA R7D-DCA R7D-DCB R7D-SV R7D-TS R7D-RS R7D-YV R7D-YS R7C-DA R7C-DCA R7C-DCB R7C-SV R7C-TS R7C-RS R7C-YV R7C-YS Compact, Multi-point Remote Economical all-in-one module for Modbus, CC-Link and DeviceNet Cost Lower Fieldbus Smaller Space 8/-point TC/DC input (isolated/non-isolated), 8- point /potentiometer input, -point discrete, -point totalized counter input modules Alarm contact output types of open network protocols 8 thr. analog channels per module EXTENSION MODULE Dry contact input, points NPN transistor output, points PNP transistor output, points Network Modbus DeviceNet CC-Link R7M-EA R7M-ECA R7M-ECB R7D-EA R7D-ECA R7D-ECB R7C-EA R7C-ECA R7C-ECB CC-Link discrete output modules (s R7C-DCA and DCB) can be extended only with the discrete output module (s R7C-ECA or DCB). Additional Functions Higher Integrity Typical Signals,, DC voltage, potentiometer, totalized pulse & discrete. Typical Output Signals Discrete Compact Size

R Multi-channel, Mixed Signal Remote Wide selection of modules and network modules. Great flexibilities in number and type of signals: DC current/voltage, temperature, strain gauge, AC current/voltage, AC power, etc. Economical DC input module can handle fully-isolated points up to non-isolated points. Hot-swappable modules and power supplies Dual redundant communication networks 00 Vac isolation MINIMUM SYSTEM CONFIGURATOR SOFTWARE RCON ON-LINE DOWNLOAD CABLE MCN-CON BASE mm / 8.8 in. (8-position base) 0 mm.7 in. 0 mm. in. MODULES POWER MODULE(S) NETWORK MODULE(S) The Power Supply Module is located at the right end, with Network Module inserted at its left. Network Module with incorporated power supply is available for small systems. Multiple modules can be mounted; No. at the extreme left end, No. and following modules to its right. M screw terminal block is used for modules. The removable terminal block is convenient for maintenance. Network Module and Power Supply Module in one housing. One module plus one Network Module with power supply is the minimum unit: Space-saving and economical solution. POWER MODULES R-PS R-PS NETWORK MODULES R-NE R-NM R-ND R-ND R-ND R-NP R-NC R-NC R-NC R-NL R-NL R-NF BASES R-BS R-BSW Rating 0V 70mA 0V.0A (double width) Capacity Modbus/TCP (Ethernet) Modbus Analog ch. DeviceNet Analog ch. Analog ch. PROFIBUS-DP CC-Link LONWORKS T-Link Same Protocol Ver. ; Analog ch. Ver. ; Analog ch. Ver. Network to Positions to Positions, free address Different Protocols Dual network communication modules are optional for mission critical applications. If you choose two different network protocols for the network modules, the remote s can be directly monitored by two different manufacturers systems. ANALOG INPUT MODULES Output R-TS (isolated) : K, E, J, T, B, R, S, C, N, U, L, P R-YV (isolated) Output: ±0V, ±V, ±V, 0 0V, 0 V, V, 0 V Accuracy: ±.0 C Accuracy: ±0.0% (±0.% for R-YV8) R-TS8 8 (isolated) Conversion rate: 0 ms or s R-YV8 8 (isolated) Response time: Max. 0. s (0 90%) R-RS (isolated) : Pt00, Pt000*, Pt0, Ni00, Ni000*, Output: 0mA Ni08.*, Cu0, Cu0 (*R-RS only) 8 (isolated) Accuracy: ±0.% R-RS8 Accuracy: ±.0 C Conversion rate: 0 ms or s DC Current R-YS (isolated) Response time: Max. 0. s (0 90%) : Pt00, -0 to +00 C Accuracy: ±0. C R-RS8A 8 (isolated) Resolution: 0.0 C Conversion rate: 0 ms or s : Open collector Rated load: Vdc R-SV, B (isolated) Pulse R-A : ±0V, ±V, ±V, 0 0V, 0 V, V, 0 V Max. frequency: 00Hz R-SV8, 8B 8 (isolated) Wide span input: ±0V, ±V, 0 0V, 0 V (R-SVxB) Totalized count: to 0000 R-SV8N 8 (non-isolated) : ±0V, ±V, 0 0V, 0 V, V R-SVN (non-isolated) ALARM MODULES R-SVA (isolated) : ±00mV, ±0mV, 0 00mV, 0 0mV, DC Millivolt 0 0mV R-SV8A 8 (isolated) (isolated) : ±0mA, 0 0mA, 0mA (0Ω) R-SS R-AT R-SS8 8 (isolated) : ±0mA, 0 0mA, 0mA (0Ω) R-AR DC Current R-SS8N 8 (non-isolated) : 0mA (0Ω) R-AV Setpoint range: -.00 to +.00% Deadband range: 0.00 to 00.00% R-SSN (non-isolated) : ±0mA, 0 0mA, 0mA (Ω) DC Current R-AS -0mA R-DS (isolated) : 0mA Supply output: 8V (Max. ma) -0mA with Excitation R-AD with Excitation R-DS8N 8 (non-isolated) : 0mA Supply output: V (Min. 00mA) R-MS (isolated) : 00Ω to 0kΩ Potentiometer R-MS8 8 (isolated) : 00Ω to 00kΩ DISCRETE MODULES Strain Gauge R-LC (isolated) : 0.0.0mV/V, 0.0.0mV/V CT R-CT (isolated) : 0 Aac, 0 Aac (RMS sensing) -point Dry Contact R-DA : Dry contact R-CTA, B (isolated) Clamp-on current sensor input CLSA: Sensing: Vdc AC Current 0 80Aac, 0 0Aac, 0 00Aac, 0 00Aac (R-CTxA) -point Contact with External Exc. R-DAA (external exc. for R-DAA) CLSB: 0 0Aac, 0 00Aac, 0 00Aac, 0 00Aac, R-CT8A, 8B 8 (isolated) 0 00Aac (R-CTxB) -point AC Contact R-DAB : 00 0Vac AC Voltage Watt Multi Power Pulse Totalized Pulse Encoder R-PT R-WT R-WTA R-WTB R-WT R-WTA R-WTB R-PA R-PAA R-PA R-PA (isolated) (isolated) system (isolated) (isolated) (isolated) : 0 0Vac, 0 0Vac System configuration: -phase/-wire, single-phase/- or -wire VT/CT input: 0Vac or 0Vac, A or A VT/Clamp-on current sensor input: 0Vac or 0Vac, 80A or 0A (R-WTA) / 0A or 00A (R-WTB) System configuration: -phase/-wire, single-phase/- or -wire VT/CT input: 0Vac or 0Vac, A or A VT/Clamp-on current sensor input: 0Vac or 0Vac, 80A or 0A (R-WTA) / 0A or 00A (R-WTB) Measurands: Active power / reactive power / power factor / frequency / active energy / reactive energy : Voltage pulse or open collector Max. frequency: 00kHz Totalized count: to 00000000 : Dry contact Sensing: Max. V (internal or external) Max. frequency: 00Hz Totalized count: to 0000 : RS- line driver Max. frequency: 00kHz ANALOG OUTPUT MODULES -point Dry Contact -point Dry Contact -point Relay Output -point Open Collector Output -point Open Collector Output -point Open Collector Output -point Triac Output BCD CODE MODULES R-DAA R-DAA R-DC R-DCA R-DCA R-DCA R-DCB : Dry contact Ext. excitatlion: Vdc Output: Relay contact Rated load: 0Vac/0Vdc 0.A Output: Open collector Rated load: Vdc Output: Triac Rated load: 00 0Vac : BCD code, 7 digits ( channels/digit) BCD Code R-BAA Ext. excitation: Vdc Output: Open collector BCD Code Output R-BCA Rated Load: Vdc

R Compact, Mixed Signal Remote Free combination of modules, network modules and power modules. Single analog module can handle fully-isolated points. Hot-swappable modules Dual redundant communication networks and power supplies Space-saving DIN terminal block or heavy-duty screw terminal block selectable for 00 Vac isolation 8-POSITION BASE -POSITION BASE M. Screws Terminal Cover POWER MODULE NETWORK MODULE MODULES M. SCREW TERMINAL BLOCK modules are also available with a heavy-duty screw terminal block. The large terminal cover is easy for maintenance. Six -mm leadwires can be housed without needing to be squeezed into it. BASE POWER MODULE(S) The Power Supply Module is located at the left end, followed by slots for Network Modules, and then, 8 or slots for s. If you only need single communication, the th or 9th module can be added to the - or 8-position base. The slanted terminals are easily accessible even with high-density wiring. NETWORK MODULE(S) mm / 9. in. (8 modules) Re-Transmitted Output DC 0mA Re-Transmitted Output Network Re-Transmitted to 0 madc output is optional for local monitoring or recording. MODULES Mains 0/0 VAC UPS VDC Add another power module for a backup power source. 90 mm. in. 90 mm. in. POWER MODULES R-PSR R-PSK R-PSL R-NE R-NM R-ND R-ND R-NP R-NP R-NC R-NC R-NF BASES R-BS0 R-BS0* R-BS08 R-BS09* R-BS Same Protocol Vdc 00 0Vac 00 0Vac NETWORK MODULES Rating Network Modbus/TCP (Ethernet) Modbus DeviceNet DeviceNet, max. analog ch. PROFIBUS-DP PROFIBUS-DP, max. analog ch. CC-Link CC-Link, max. analog ch. T-Link Capacity modules modules 8 modules 9 modules modules *Single Network Module Different Protocols Dual network communication modules are optional for mission critical applications. If you choose two different network protocols for the network modules, the remote s can be directly monitored by two different manufacturers systems. ANALOG INPUT MODULES DC Current -0mA with Excitation CT Totalized Pulse R-TS R-TS RT-TS RT-TS R-RS RT-RS R-RS RT-RS R-SV R-SV R-SS R-SS R-DS R-DS RT-SV RT-SV RT-SS RT-SS RT-DS RT-DS RT-CT RT-CT R-PA RT-PA : K, E, J, T, B, R, S, C, N, U, L, P Accuracy: ±0. C Response time: Max. 0. s (0 90%) : Pt00, Pt000, Pt0 and Ni00, Ni08., Cu0, Cu0 Accuracy: ±0. C Response time: Max. 0. s (0 90%) : -0 +0V, V, etc. Accuracy: ±0.0% Response time: Max. 0. s (0 90%) : ±0mA, ±0mA, ±ma, 0 0mA, 0 0mA, 0mA, 0 ma, Accuracy: ±0.% Response time: Max. 0. s (0 90%) : 0mA Accuracy: ±0.0% Response time: Max. 0. s (0 90%) Supply output: 8V (max. ma) : 0 Aac Accuracy: ±0.%(at 00% input) Response time: Max. 0. s (0 90%) : Dry contact; Common negative Sensing: Max. V Max. frequency: 00Hz Response time: Max. 0. s ANALOG INPUT MODULES with RE-TRANSMITTED OUTPUT R-TSA R-RSA R-SVA DC Current R-SSA -0mA with Excitation R-DSA : K, E, J, T, B, R, S, C, N, U, L, P Output: 0mA : Pt00, Pt000, Pt0, Ni00, Ni08., Cu0, Cu0 Output: 0mA : ±0V, ±V, ±V, 0 0V, 0 V, V, 0 V Output: 0mA : ±0mA, ±0mA, ±ma, 0 0mA, 0 0mA, 0mA, 0 ma Output: 0mA : 0mA Supply output: 8V (max. ma) Output: 0mA ANALOG OUTPUT MODULES Output -0mA R-YV R-YV RT-YV RT-YV R-YS RT-YS R-YS RT-YS Totalized Pulse R- RT- DISCRETE INPUT MODULES Di Points R-DA RT-DA Di Points R-DA (Connector) DISCRETE OUTPUT MODULES Output Do Points R-DC RT-DC Do Points R-DC (Connector) ON-LINE DOWNLOAD Output: -0 +0V, V, etc. Accuracy: ±0.0% (-0 +0V) Response time: Max. 0. s (0 90%) Output: 0mA Accuracy: ±0.% Response time: Max. 0. s (0 90%) Output: Photo MOSFET relay; Each ch. independent Rated load: Vac/dc 0mA Max. frequency: 00 Hz Response time: Max. 0. s : Dry contact; Common per chs Sensing: V (V external supply selectable) Response time: Max. 0. s : Dry contact; Common negative Sensing: V (V external supply selectable) Response time: Max. 0. s Relay output: Common per chs Rated load: 0Vac/0Vdc 0.A Response time: Max. 0. s Open collector output: Common negative Rated load: 0V/0mA Response time: Max. 0. s CONFIGURATOR SOFTWARE RCON CABLE MCN-CON

R Compact, Multi-point Remote Economical all-in-one module for Modbus, CC-Link and DeviceNet 8/-point TC/DC input (isolated/non-isolated), 8-point /potentiometer input, -point discrete, -point totalized counter input modules Alarm contact output FRONT FRONT FRONT -POINT DISCRETE INPUT MODULE (connector type available) RM-A -POINT OPEN COLLECTOR OUTPUT MODULE (screw terminal block type available) RM-D -POINT UNIVERSAL INPUT MODULE RZMS-U9 -POINT DC/TC INPUT MODULE RC-GH REAR -POINT DC/TC INPUT MODULE RD-GH REAR -POINT DC/TC INPUT MODULE RM-GH REAR 8-POINT DC/TC INPUT MODULE, ISOLATED RMS-GH 8-POINT /POT INPUT MODULE RM-J TOTALIZED COUNTER INPUT MODULE RM-P Modbus Type : s or DC voltage, points; type and range is independently configurable for each channel. DC/TC, Points RM-GH Trigger : Dry contact, point DC/TC, 8 points Fully Isolated /POT, 8points Universal, points (isolated) Totalized Pulse, 8 points Discrete, points Discrete Output, points CC-Link, DeviceNet Type CC-Link DC/TC, points DeviceNet DC/TC, points RMS-GH RM-J RZMS-U9 RM-P RM-A RM-D RC-GH RD-GH : s or DC voltage, 8 points; type and range is independently configurable for each channel. Trigger : Dry contact, point Alarm Output: Photo MOSFET relay, point : or potentiometer resistance, 8 points; type and range is independently configurable for each channel. Trigger : Dry contact, point : DC voltage,, or potentiometer, points; type and range is independently configurable for each channel. Trigger : Dry contact, point Alarm Output: Photo MOSFET relay, point Totalized Pulse : Dry contact, points Discrete : Dry contact, 8 points (usable for totalizer) Discrete Output: Open collector, 8 points Trigger : Dry contact, point : Dry contact, points (M screw terminal block or connector) Common: All points Sensing: Approx. V (pull-up resistance kω Output: Open collector, points (M screw terminal block or connector) Common: All points Rated Load: V/0 ma (resistive load) : s or DC voltage, points; type and range is independently configurable for each channel. : s or DC voltage, points; type and range is independently configurable for each channel. CONFIGURATOR SOFTWARE RCON CABLE ON-LINE DOWNLOAD R Series GENERAL Power 00 0Vac, Vdc Dimentions W7 x H x D0mm Weight Approx. 00 g 0 00Ω, 0 00Ω, 0 kω, 0 0 kω Accuracy ±0.% RZMS-U9 Potentiometer (RM-J) ( C) Accuracy (%) JPt 00 (JIS '89) -00 +00 ±0. Pt 00 (JIS '89) -00 +0 ±0. Pt 00 (JIS '97, DIN, IEC7) -00 +80 ±0. Pt 0Ω (JIS '8) -00 +9 ±0. Ni 08.Ω -0 +00 ±0. Pt 000-00 +80 ±0. GENERAL Power 00 0Vac, Vdc Dimentions W7 x H8 x D.mm Weight Approx. 0g Potentiometer 0 00Ω, 0 00Ω, 0 kω ±0mV, ±mv, ±0mV, ±00mV, ±.0V, ±V, ±V, ±V (Rx-GH) T/C ( C) Accuracy ( C) (PR) 0 +70 ±0.* K -70 +70 ±0. E -70 +000 ±0.7 J -0 +00 ±0.7 T -70 +00 ±.0 B 0 80 ±0.7* R -0 +70 ±0.7* S -0 +70 ±0.7* C 0 +0 ±0.7 N -70 +00 ±0. U -00 +00 ±0. L -00 +900 ±0. P 0 9 ±0. * 00 C or higher / * 700 C or higher (Rx-GH) ±0V, ±V, ±V, ±0.8V, ±0.V, ±0mV, ±0mV T/C Accuracy ±0.% ( C) (PR) 0 +70 K -70 +70 E -70 +000 J -0 +00 T -70 +00 B 00 80 R -0 +70 S -0 +70 C 0 +0 N -70 +00 U -00 +00 L -00 +900 P 0 9 (RMS-GH) (PR) 0 +70 ±. K -70 +70 ±. E -70 +000 ±0.8 J -0 +00 ±.0 T -70 +00 ±. B 0 80 ±7. R -0 +70 ±.8 S -0 +70 ±. C 0 +0 ±.9 N -70 +00 ±.9 U -00 +00 ±. L -00 +900 ±.0 P 0 9 ±.7 (RMS-GH) Accuracy ±0V ±0.0% (±0mV) T/C ( C) Accuracy ( C) ( C) Pt 00 (JIS '89) -00 +0 Pt 00 (JIS '97, DIN, IEC) -00 +80 Pt 00-00 +80 Pt 00-00 +80 Pt 00-00 +80 Pt 00-00 +80 Pt 000-00 +80 Pt 0Ω (JIS '8) -00 +9 JPt 00 (JIS '89) -00 +0 Ni 00-80 +0 Ni 0-80 +0 Ni 08.Ω -0 +0 Ni-Fe 0-00 +00 Cu 0 ( C) -0 +0 MCN-CON