ENGLISH. Terminals 13, 14, 23, 24, 43, 44, 53, Web: Phone: Toll Free:

Similar documents
Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6960

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6961

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

Safety Technique. SAFEMASTER Light Curtain Controller With Selectable Operating Modes BH 5902/01MF2

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Installation / Control Technique

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Original operating instructions Safety relay with relay outputs G1501S / / 2016

PSR DC/ESP4/2X1/1X2

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

PSR UC/ESAM4/3X1/1X2/B

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

E-STOP relays, safety gate monitors

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

Dold BH5928 Series 2-Channel Emergency Stop and Safety Gates with Delay

PNOZ s1. Safety relays. Operating Manual EN-07

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Electronic timer CT-ERD.12

Datasheet - SRB 402EM-24V

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

SNO 4003 K plus. Areas of application for the unit. Connection circuit diagrams. Intended use. Competent persons. Equipment and functional description

Electronic timer CT-AHD.22

Datasheet - SRB 301LC/B-24V

Operating instructions. Speed monitor D / / 2014

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

Two-hand control unit

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

E-STOP relay, safety gate monitor

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

MSR178DP. Description. Features. Specifications

E-STOP relays, safety gate monitors

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Electronic timer CT-ERS.21

Safe timer relay/contact expansion modules

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

Original operating instructions Fail-safe inductive sensor GG711S

PNOZ s2. Safety relays. Operating Manual EN-07

MSI-RM2 Safety Relays

Operating instructions Safety-monitoring module SRB 100DR. 1. About this document. Content

Original operating instructions Fail-safe inductive sensor GI712S

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Two-hand control unit

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Electronic timer CT-ARS.11

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Datasheet SRB301ST 24V (V.2)

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Operating instructions. Standstill monitor A / / 2011

E-STOP relays, safety gate monitors

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

SNO 4062K SNO 4062KM SNO 4062 K / KM. Circuit diagram. Applications. Function. Function (Continued)

E-STOP relays, safety gate monitors

Power supply CP-C 24/5.0

MINI-PS AC/10-15DC/8

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous

Two-hand control unit

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Safety relay emergency stop/protective door, 230VAC, 3 enabling paths

PNOZ s9. Safety relays. Operating Manual EN-08

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Safety relay emergency stop/protective door, 24V-230VDC/AC, 3 enabling paths

Operating Instructions

Operating instructions Safety-monitoring module SRB 301MC SRB 301MC-ST. 1. About this document. Content

E-STOP relay, safety gate monitor

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Safety relay emergency stop/protective door, 24VDC/AC, 3 enabling paths

Operating instructions. Switching amplifier DN0210 DN / / 2015

Contact protection relay

Operating instructions Safety-monitoring module SE-304 C. 1. About this document. Content

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

BT50(T) Safety relay / Expansion relay

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Operating instructions Fail-safe standstill monitor FWS About this document. Content

ELR H3-IES-PT- 24DC/500AC-...

E-STOP relay, safety gate monitor

PHOENIX CONTACT - 07/2006

Safety relays PNOZsigma

Operating instructions (short version) Safety monitor AS-Interface Safety at Work ASM E1-R2 ASM E2-R2/R2. 1. About this document.

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Operating instructions Safety-monitoring module SSW 301HV. 1. About this document. Content

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

Power supply CP-D 12/2.1 Primary switch mode power supply

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Phone: Fax: Web: -

Controller CMXH. Description STO. Safe Torque Off (STO) [ ]

E-STOP relays, safety gate monitors

Original instructions Vital 1 Safety module

BETRIEBSANLEITUNG TECHNICAL INSTRUCTION INTERFACE PSE2-SC-02 (24 V AC/DC) Version 1.4

User's Manual. english

Transcription:

Operating Manual ENGLISH 0266691 PRSU/M2SI Multifunctional Downstream Device ORIGINAL Before installing, operating or maintaining the device, read underst this manual. DANGER Dangerous tension. Danger to life or serious injury. Disconnect the system device from the power before starting work. ATTENTION A secure device function is only guaranteed with certified components! Hints The products described here are designed to perform safety-related functions as part of an overall plant or machine. A complete safetyrelated system usually contains sensors, evaluation units, signaling devices concepts for safe shutdowns. It is the responsibility of the manufacturer of a system or machine to ensure the correct overall function. Tapeswitch is unable to guarantee all the features of a complete system or machine that was not designed by Tapeswitch. The overall concept of the controller in which the device is integrated must be validated by the user. Tapeswitch also assumes no liability for recommendations that are given or implied by the following description. Due to the following description, no new warranty, warranty or liability claims beyond the general tapeswitch delivery conditions can be derived. - - Safety Regulations The device may only be installed commissioned by knowledgeable persons who are familiar with this operating manual with the applicable regulations on occupational safety accident prevention. Observe the VDE local regulations, especially with regard to protective measures. - Opening the case or unauthorized modifications will invalidate any warranty. - Mount the device in a control cabinet with degree of protection IP 54 or better; Dust moisture can otherwise lead to impairments of the functions. - Provide sufficient protective wiring at all output contacts for capacitive inductive loads. - The safety function must be triggered during commissioning. Intended Use If used as directed in accordance with this manual, no residual risks are known. Failure to do so may result in personal injury property damage. The PRSU / M2SI is used for the safety-related release interruption of a safety circuit. It can be used to protect people machinery in applications with emergency stop pushbuttons, safety gates, self-test (type 4) photocells in accordance with IEC / EN 61 496-1, two-h switches for metalworking presses, other working machines with dangerous closing movements (Type III C according to EN 574) for safety-related safety mats, safety edges b switches. Device Properties Your advantages two independent safety functions adjustable out: - Safety mat / strip, b switch - photocell - Emergency stop switch - Safety gate - two-h control - Antivalent switch only one device type, two safety functions at the same time manual or automatic start Characteristics complies - Performance Level (PL) e Category 4 according to EN ISO 13849-1: 2008 - SIL claim limit (SIL CL) 3 according to IEC / EN 62061 - Safety Integrity Level (SIL) 3 according to IEC / EN 61508 IEC / EN 61511 according to EN 50156-1 for combustion plants Line fault detection on the ON button Activation via on-button or automatic on-function with or without cross-circuit detection 2-channel design positively driven output contacts Output: 2 NO contacts per safety function 1 semiconductor output per safety function LED indicators operating voltage, safety function 1, 2 error Device connections: pluggable terminal blocks with screw terminals Safety Instructions ATTENTION - AUTOMATIC START! According to IEC / EN 60 204-1 point 9.2.5.4.2, no automatic start must be made after stopping in an emergency. Therefore, in the modes with automatic start, a higher-level control must prevent an automatic start after an emergency stop. Terminals Terminal Designation A1 + A2 13, 14, 23, 24, 43, 44, 53, 54 Signalbeschreibung DC24V 0V Normally open for release circuit 38, 68 Semiconductor monitoring output GND Reference potential for semiconductor signal outputs S11, S21, S31, S41 control outputs S12, S22, S32, S42, ST1, ST2, RES control outputs E-mail: sales@tapeswitch.com Web: www.tapeswitch.com Phone: 631-630-0442 Toll Free: 800-234-8273 All information in this manual corresponds to the technical state at the time of issue. We reserve the right to make technical improvements changes at any time. 1 10/2015 EN

Operating instructions ENGLISH 0266691 PRSU/M2SI Multifunctional Control Unit ORIGINAL Before installing, operating or maintaining this device, these instructions must be carefully read understood. DANGER Dangerous voltage. Electric shock will result in death or serious injury. Disconnect all power supplies before servicing equipment. CAUTION Safe operation of the device is only guaranteed when using certified components! Important Notes The product hereby described was developed to perform safety functions as a part of a whole installation or machine. A complete safety system normally includes sensors, evaluation units, signals logical modules for safe disconnections. The manufacturer of the installation or machine is responsible for ensuring proper functioning of the whole system. Tapeswitch cannot guarantee all the specifications of an installation or machine that was not designed by Tapeswitch. The total concept of the control system into which the device is integrated must be validated by the user. Tapeswitch also takes over no liability for recommendations which are given or implied in the following description. The following description implies no modification of the general Tapeswitch terms of delivery, warranty or liability claims. Safety Regulations - This device must be installed operated by trained staff who are familiar with these instructions with the current regulations for safety at work accident prevention. - Pay attention to applicable local regulations, especially regarding safety measures. - Opening the device or implementing unauthorized changes voids any warranty - The unit should be panel mounted in an enclosure rated at IP 54 or superior. Dust dampness may lead to malfunction. - Adequate fuse protection must be provided on all output contacts with capacitive inductive loads. - The safety function must be triggered during commissioning Main Features Your Advantage 2 independent, separately adjustable safety functions: - Safety mat / Safety edge / Tapeswitch - Light curtain - E-Stop - Safety gate - Two-h control - Exclusive or contacts Only one device, two safety functions at the same time Manual or auto start Features According to - Performance Level (PL) e category 4 to EN ISO 13849-1: 2008 - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061 - Safety Integrity Level (SIL) 3 to IEC/EN 61508 IEC/EN 61511 Acc. to EN 50156-1 for furnaces Line fault detection on On-button: Manual restart or automatic restart With or without cross fault monitoring 2-channel Forcibly guided output contacts Output: 2 NO contacts per safety function 1 semiconductor output per safety function LED indicator for operation, safety function 1, 2 failure Removable terminal strips: plug in screw terminals Safety Notes ATTENTION - AUTOMATIC START! According to IEC/EN 60 204-1 part 9.2.5.4.2 10.8.3 it is not allowed to restart automatically after emergency stop. Therefore the machine control has to disable the automatic start after emergency stop. Designated Use When used in accordance with its intended purpose following these operating instructions, this device presents no known residual risks. Nonobservance may lead to personal injuries damages to property. The PRSU/M2SI is used to enable interrupt a safety circuit in a safe way. It can be used to protect people machines in applications with e-stop buttons, safety gates, light curtains with selftesting (Type 4) acc. to IEC/EN 61 496-1, 2-h controls for presses as well as other production machinery with dangerous closing action (Type III C to EN 574) for safety mats, safety edges tape switches. Connection Terminals Terminal designation A1 + A2 13, 14, 23, 24, 43, 44, 53, 54 Signal designation DC 24 V 0 V Forcibly guided NO contacts for release circuit 38, 68 Semiconductor monitoring output GND S11, S21, S31, S41 control output S12, S22, S32, S42, ST1, ST2, RES Reference potential for Semiconductor monitoring output control input All technical data in this manual relate to the state at the moment of edition. We reserve the right for technical improvements changes at any time. 2 10/2015 EN

Practical Notes Operation mode With the potentiometer on the front plate the operartion mode can be adjustet. The adjustment must be required before energizied. Adjustment during energization is not allowed. Only an automatic start at safety function two-h control (3) is possible. Start Fkt. 1 Fkt. 2 1 MANUAL MANUAL 2 MANUAL AUTO 3 AUTO HAND 4 AUTO AUTO MANUAL with common 5 button Line fault detection e.g. monitoring of ON-button If the On-button pressed more than 3 s the adequate output contacts of the safety function can't be switch. The output contacts can be energized when the On-button pressed again (0.1 s < t ON < 3 s). A line fault is detected if the On-button more than 10 s is actuated. The output contacts of the adeauate safety function can only be energized with a reset or re-start with on an off switching of power supply. ATTENTION - AUTOMATIC START! According to IEC/EN 60 204-1 part 9.2.5.4.2 10.8.3 it is not allowed to restart automatically after emergency stop. Therefore the machine control has to disable the automatic start after emergency stop. Reset external failures: The reset input is used to reset external failures (application failures or removable external failures as e.g. a line fault on reset button). If the reset signal is connected to the input for more than 3 sec the unit unit makes a reset. A new reset is only possible when the reset signal had been switched off temporarily. If an external failure occurs because both input channels of a safety function did not switch on or off within the simultanious time, a reset is only possible if both channels are switched to off state after removing failure cause. If an external failure occurs in only one safety function, only this function will be disconnected. The second safety function still continuous to work. Operating Potentiometer Poti "Start" Indicators green LED ON: red LED ERR: green LED K1/K2: green LED K3/K4: Adjustment of operating mode Manual- or auto start for Fkt.1 Fkt. 2. Poti "Fkt.1" Adjustment of safety function 1 Poti "Fkt.2" Adjustment of safety function 2 Fault Indication by Flashing Code Potentiometer or adjustment failure line fault across start button Cross fault or wiring fault simultaneity error on, when supply connected on, at internal error flashes at external error on, when relay K1 K2 energized (safety function 1) flashes at external errors of safety function 1 on, when relay K3 K4 energized (safety function 2) flashes at external errors of safety function 2 M10697_a Function setting The variants with selectable safety functions have 2 potentiometers Fkt.1 Fkt.2 to select the required function. The following functions are possible: Fct. 1 / Fct. 2 Safety function 1 E-Stop 2 Safety gate 3 Two-h control 4 Safety mat / Safety edge 5 Exclusive or contacts 6 E-Stop 7 Safety gate 8 Light curtain cross fault detection without cross fault detection 3 10/2015 EN

Function diagram t diff : max. time delay for simultaneity dem dependent on selected safety function Safety mat, Sensing Edge, Tapeswitch, E-Stop, Safety Gatet diff = max. 3s Light curtain t diff = max. 1s Two-h control t diff = max. 0,5s other times on request t On : max. actuation time of start button Stard t On : max. 3s other times on request Technical Data Input Nominal voltage U N : DC 24 V Voltage range: 0.8... 1.1 U N Nominal consumption: typ. 3.2 W Short-circuit protection: Internal PTC Overvoltage protection: Internal VDR Duty-cycle ON button: 0.1 s < t EIN < 3 s Duty-cycle Reset button: > 3 s Safety function Safety mat / safety edge / Tapeswitch (4) max. permitted safety edge contact resistance: 1000 Ω switching current at short circuit: typ. 15 ma at U N Light curtains (8) control current via S12, S22 e.g. S32, S42: typ. 8 ma at U N Min. voltage on terminals S12, S22 e.g. S32, S42 when relay activated: DC 10 V Output Contacts 2 NO contacts per safety function The NO contacts can be used for safe braking. Thermal current Strom I th : max. 8 A Technical Data Safety function E-Stop (1) (6), Safety gate (2) (7), Exclusive or contacts (5) Start up at U N : < 65 ms disconnecting the supply: < 40 ms disconnecting S12,S22 or S32, S42: < 60 ms Two-h control (3) Start up at U N : < 110 ms disconnecting the supply: < 40 ms disconnecting S12,S22 or S32, S42: < 60 ms simultaneity dem: max. 0,5 s Safety mat (4) / Safety Edge / Tapeswitch Start up at U N : < 85 ms disconnecting the supply: < 40 ms disconnecting S12,S22 or S32, S42: < 60 ms Light curtains (8) Start up at U N : < 35 ms disconnecting the supply: < 40 ms disconnecting S12,S22 or S32, S42: < 25 ms 4 10/2015 EN

Technical Data Switching capacity to AC 15 NO contacts: 3 A / AC 230 V IEC/EN 60 947-5-1 to DC 13 NO contacts: 2 A / DC 24 V IEC/EN 60 947-5-1 Electrical life at 5 A, AC 230 V cos j = 1: > 1.5 x 10 5 switching cycles Permissible operating frequency 1. safety function: max. 1800 switching cycles / h 2. safety function: max. 360 switching cycles / h Short circuit strength max. fuse rating: 6 A gl IEC/EN 60 947-5-1 Mechanical life: 10 x 10 6 switching cycles Semiconductor monitoring output (not safety): General Data 1 per safety function max. 50 ma DC 24 V, plus switching Nominal operating mode: continuous operation Temperature range Operation: - 15... + 55 C Storage: - 25... + 85 C Altitude: < 2.000 m Clearance creepage distance rated impuls voltage / pollution degree: 4 kv / 2 IEC 60 664-1 EMC Electrostatic discharge (ESD): 8 kv (air) IEC/EN 61 000-4-2 HF irradiation: 10 V / m IEC/EN 61 000-4-3 Fast transients: 2 kv IEC/EN 61 000-4-4 Surge voltage between wires for power supply: 1 kv IEC/EN 61 000-4-5 between wire ground: 2 kv IEC/EN 61 000-4-5 HF-wire guided: 10 V EN 61 000-4-6 Interference suppression: Limit value class B EN 55 011 Degree of protection Housing: IP 40 IEC/EN 60 529 Terminals: IP 20 IEC/EN 60 529 Housing: thermoplastic with VO behaviour according to UL subj. 94 Vibration resistance: Amplitude 0,35 mm Frequency 10... 55 Hz, IEC/EN 60 068-2-6 Klimate resistance: 15 / 055 / 04 IEC/EN 60 068-1 Terminal designation: EN 50 005 Wire connection: DIN 46 228-1/-2/-3/-4 Wire fixing: captive slotted screw Troubleshooting Failure LED "ON" does not light up LED "ERR" flashes in relation 1:1 LED "ERR" flashes in relation 4:1 LED "ERR" continuously on Maintenance Repairs Potential cause - Power supply A1+/A2 not connected - Under- or overvoltage (check power supply A1+/A2) - external failure (see flashing code) - system error (if cannot be removed after restart unit must be replaced) - The device contains no parts that require maintenance. - In case of failure, do not open the device but send it to manufacturer for repair. Mounting: DIN rail IEC/EN 60 715 Weight: approx. 275 g UL-Data The safety functions were not evaluated by UL. Listing is accomplished according to requirements of Stard UL 508, general use applications Switching capacity: Ambient temperature 55 C Ambient temperature 40 C: Wire connection:: Terminal: Pilot duty B300, Q300 5A 250Vac Resistive or G.P. 5A 24Vdc Resistive Pilot duty B300, Q300 8A 250Vac Resistive or G.P. 8A 24Vdc G.P. 60 C / 75 C copper conductors only AWG 28-12 Sol/Str Torque 0.5 Nm 5 10/2015 EN

Application examples with safety function PRSU/M2SI Operating mode: 3 (Fkt1=AUTO ; Fkt2=MANUAL) Safety function 1: see page 7, Auto-Start Safety function 2: see page 7, Manual-Start PRSU/M2SI Operating mode: 5 (MANUAL with common button) Safety function 1: see page 7, Manual-start with common button Safety function 2: see page 7, Manual-start with common button 6 10/2015 EN

Application examples with safety function 1 Schiebeschutztür geschlossen Not- Aus S1 S2 Fct.: E-stop (1), with cross fault detection M10757 Fct.: Safety gate (2), with cross fault detection M10756 Fct.: Two-h control (3), with cross fault detection Type III C to EN 574 M10750 Schaltleiste S1 Not- Aus M10754 Fct.: Safety mat / Safety edge / Tapeswitch (4), with cross fault detection Fct.: Exclusive or contacts (5), with cross fault detection M11124 M10753 Fct.: E-Stop (6), without cross fault detection 1) Schiebeschutztür geschlossen DC 24V 0V Empfänger Sender OSSD1 OSSD2 S21 S22 S11 S12 M10752 Fct.: Safety gate (7), without cross fault detection 1) Fct.: Light curtain (8), without cross fault detection 2) M10751 1 ) To achieve the stated safety classification the wiring has to be done with crossfault monitoring. 2 ) To achieve the stated safety classification light curtains with selftest (type 4) according to IEC/EN 61496-1 have to be used. Application examples with safety function 2 The safety function 2 is connected as well as safety function 1, but S11 S31, S12 S32, S21 S41 S22 S42. 7 10/2015 EN

Labeling connections Circuit diagram 13 14 23 24 A1+ A2 ST1 38 S11 S12 S21 S22 K1 K2 13 23 + 43 53 K1/K2 K3 K4 14 24 38 44 54 + K3/K4 68 S31 S32 S41 S42 RES GND ST2 68 M10501_a 43 44 53 54 M10707 M4288_a DIN 5264-A; 0,6 x 3,5 0,5 Nm 5 LB. IN A M10248 A M10249 A M10250 A = 7 mm 1 x 0,2... 2,5 mm 2 1 x AWG 24 to 12 2 x 0,2... 1,0 mm 2 2 x AWG 24 to 18 A = 7 mm 1 x 0,25... 2,5 mm 2 1 x AWG 24 to 12 2 x 0,25... 1,0 mm 2 2 x AWG 24 to 18 A = 7 mm 1 x 0,2... 2,5 mm 2 1 x AWG 24 to 12 2 x 0,2... 1,5 mm 2 2 x AWG 24 to 16 Dimensions (dimensions in mm) Mounting / disassembly of the terminal blocks +0,7 122,6-0 B +0,7 115,3-0 M4345_a 35 106,9 A M4345_a A B PRSU/M2SI 110 ± 1 22,5 8 10/2015 EN

Safety related data CE-Declaration of Conformity EN ISO 13849-1: Category: 4 PL: e MTTF d : 134,5 a (year) DC avg : 99,0 % d op : 365 d/a (days/year) h op : 24 h/d (hours/day) t cycle : 3600 s/cycle = 1 /h (hour) IEC/EN 62061 IEC/EN 61508 IEC/EN 61511: SIL CL: 3 IEC/EN 62061 SIL: 3 IEC/EN 61508 / IEC/EN 61511 HFT *) : 1 DC avg : 99,0 % SFF: 99,6 % PFH D : 3,89E-10 h -1 PFD: 3,27E-05 T 1 20 a (year) *) HFT = Hardware failure tolerance nfo The values stated above are valid for the stard type. Safety data for other variants are available on request. The safety relevant data of the complete system has to be determined by the manufacturer of the system. Approvals Markings Dem to our device based on the evaluated neccessary safety level of the application. Intervall for cyclic test of the safety function TÜV Baumuster geprüft EN ISO 13849-1 IEC/EN 62061, IEC/EN 61508 PL e with Cat. 3 or Cat. 4 PL d with Cat. 3 SIL CL 3, SIL 3 with HFT = 1 SIL CL 2, SIL 2 with HFT = 1 once per month once per year once per month once per year EN 61511, EN 50156-1 SIL 3 once per year Tapeswitch Corporation e-mail: sales@tapeswitch.com web: http://www.tapeswitch.com Phone: 631-630-0442 Toll Free: 800-234-8273 9 10/2015 EN