Starbreaker Consumer Units & Devices

Similar documents
Starbreaker Consumer Units for Domestic Household - and other - Premises. Amendment No. 3 BS 7671

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its

Consumer Units IP Rated & Metal Enclosures Devices - MCBs, RCBOs & RCDs. Control Devices & Accessories

Protect Circuit Protection

EUSR. An Introduction To BS7671 Amendment 3:2015 DESIGNED FOR featuring Consumer Units for Domestic (Household) Premises as per Reg

Sentry. Flush mounting versions Flush mounting available for even neater installations.

Design Range of Consumer Units. Amendment 3 compliant

TP&N DISTRIBUTION BOARD TYPE B RANGE

Defender 1.0. Consumer Units & Devices Domestic Household Premises

Design Range of Consumer Units. Amendment 3 compliant

Defender 1.0. Consumer Units & Devices Domestic Household Premises

RCCB

Residential circuit protection buyers guide

Defender. Consumer Units & Devices Domestic Household Premises

Doepke MAIN SWITCH OPTIONS. The insulated consumer unit range consists of four enclosure sizes to enable any combination from 1 to 16 usable ways.

NEW Titan II A & B Distribution Boards

ßCompliant with Amendment 3 ßBSEN for easy cabling. accommodate RCBOs. meeting current standards

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

Technical data Consumer units and enclosures dimensions and data 12.4

The right solution for every home

F550e E-learning course Residual current devices basics RCDs Standards. ABB Group April 2, 2009 Slide 1

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip

LOADSTAR MCBs AND DISTRIBUTION BOARDS

3RV1 Circuit-Breakers

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings

Residential Distribution

Consumer Units - Metal

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

Domae and Qwikline ll. Consumer units

Dtec Consumer units and

ALPHA SIMBOX Small Distribution Boards

Sentry Technical. Consumer Units and Enclosures TD255. Standards and approvals. Description. Features. Technical specification

Design Range of Consumer Units

Design Range of Consumer Units

125A SPN, type A distribution boards Incoming devices Meterpack assemblies Surge protection devices... 34

Enclosures & Rotary Switches

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP

RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

Slimline. Technical Hotline

FAQ about Drives Technology

RCDs: everything an electrician should know

GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding

DSE201, DSE201 M Compact design with enhanced protection

B60 Domestic Voltage Optimisation Unit. Installation Manual

Talisman Plus. MCB Distribution Boards & Miniature Circuit Breakers BILL MEANS BUSINESS

SPM Series Plug-in Surge Protection

B60 Domestic Voltage Optimisation Unit

Miniature. Circuit Breakers. reliable solutions for protection of installations against over-current phenomenon. Advantages for you : Technical data :

RCDs RCBOs MCBs Isolating Switches Switchboards

Allen-Bradley 1492-RCDA4A40

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

Electrical Demand Specification (Reference SOP: )

Weathersafe Vision. Installation & Operating Instructions

Dorman Smith Loadbank 125 MCCB Panel Boards

1492-SP Supplementary Protectors

RiLine Compact The smart power distribution system

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

17 th Edition (BS 7671:2008) incorporating Amendment No 1

ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Flatwall. Aesthetic value and functional integration for home automation

SPM Series. Plug-in Surge Protection

MC 11 EB-2 Power supply cabinet with external bus, AC version

Defender B Board. Make The Switch

RB60 RANGE. Miniature circuit breakers

Prisma Plus System P Cubicles up to 4000 A

LoadCentre KQ+ Distribution boards

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches

Memguard Advantage DISTRIBUTION SYSTEM Product Guide. MCB Single Phase Distribution Boards MCB Three Phase Distribution Boards

SECTION DISCONNECT SWITCHES

phone fax post web ordering information Please call for the latest pricing or to request a free price list.

Smart solutions for electrical distribution in commercial and industrial applications

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

PDI Modular Compact Remote Power Panel

CABINETS & ENCLOSURES FOR PREPAYMENT METERS

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

CONTROL PANEL WIRING SPECIFICATIONS

SRI LANKA STANDARD CODE OF PRACTICE FOR GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS SLS 1522:2016

FIBARO SINGLE SWITCH

SECTION PANELBOARDS

AThink future. Switch to green. MCCB Panel Boards 400A / 630A / 800A.

MMLG 01, 02, 03, 04 MMLB01

B60 PVM Domestic Voltage Optimisation Unit. Installation Manual

Smart solutions for electrical distribution in commercial buildings

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A

AMIGO-Distribution Boards for flush mounting

O V E R Y E A R S O F E L E C T R I C A L E X C E L L E N C E

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

BCM2 Series Branch Circuit Monitors Quick Setup Guide

modular enclosure MUREVA, IP65 weatherproof & versatile enclosures aesthetics multi-functional evolutionary ergonomics and time saving security

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

Smart solutions for electrical distribution in commercial buildings

Energy Division. Crompton Instruments Ebony Current Transformers

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008

Transcription:

Starbreaker Consumer Units & Devices

Acknowledged as one the leading brands in the UK and in British Standard markets around the world, Crabtree offers designers & specifiers a wide range of quality products that caters for a vast array of applications including Commerce, Offices, Education, Hospitals & Health, Hotels & Leisure facilities, in fact wherever quality products are required. Crabtree factories operate a series of internationally recognized standards including ISO9001 for quality, OHSAS 18001 for Health & Safety and ISO14001 for Environmental Management. The UK production locations are home to the product management, engineering, design, quality & logistics teams. In the UK Crabtree operates two UKAS accredited Laboratories that carry out R&D and compliance testing on all Crabtree products, these highly accredited facilities ensure that safety, quality & reliability remain consistent with UK & EU legislation regulations & Siemens internal standards, policies and practices. Crabtree products are all designed manufactured and tested in accordance with the recognised product standards, and backed by standard & extended guarantees. Crabtree also operates to recognised standards for product safety & sustainability, Crabtree wiring accessories are RoHS and REACH compliant often in excess of the UK market standards. Crabtrees WEEE compliance process and recycling scheme ensures that the end of product life circumstances are catered for in line with UK & EU Legislation. Recycled materials are used in product packaging, and declared into a recycling scheme locally to control environmental impacts and assure that the maximum level of recycling of materials and use of recycled materials is achieved. As a Siemens company Crabtree also operates a zero harm scheme within all of its manufacturing, logistics & sales facilities, and is proud to have achieved a 5 star Health & Safety rating.

CONSUMER UNITS FOR USE IN DOMESTIC HOUSEHOLD PREMISES Contents REGULATIONS 2 CONSUMER UNIT OVER VIEW 4 STARBREAKER CONSUMER UNITS 5 STARBREAKER MCBs & RCBOs 10 STARBREAKER AFDDs 10 DIN DEVICES 11 DIMENSIONS 12 1. Cannock Commercial Headquarters Home to Sales & Marketing, Supply Chain Management, Finance & Customer Service. 2. Wythenshawe Manufacturing location for domestic & commercial circuit protection, with R&D, UKAS test laboratory ISO9001 production facilities. 3. Hindley Green Production location for wiring accessories & domestic circuit protection with R&D, UKAS test laboratory ISO9001 production, warehouse, distribution & logistics facilities. All Crabtree products comply with the applicable British Standard specification and should be installed by suitably qualified personnel in accordance with the requirements of relevant legislation, regulations (including IET Wiring Regulations) and the accepted practice in the industry. The products listed or described in this publication may be protected by one or more patents, and/or registered designs and/or applications. A full list of patents registered designs and applications may be obtained from the company secretary of Electrium Limited. 1

THE WIRING REGULATIONS & DOMESTIC HOUSEHOLD PREMISES NON COMBUSTIBLE CONSUMER UNIT ENCLOSURES BS 7671 (IET Wiring Regulations) prescribe that within domestic household premises consumer units & similar switchgear assemblies must have the enclosures manufactured from noncombustible material e.g. steel, and comply with BS EN 61439-3. The term enclosure includes the box, cover, door, hinges, & fixing screws, all of which must be noncombustible. It can also include the blanks that are used in the cover where there are unused ways. Similar switchgear includes domestic switch fuse units, small consumer units that may be used in detached garages & outbuildings, and other circuit protection assemblies that are used in domestic household premises. ADDITIONAL PROTECTION BY 30mA RCD Several regulations call for additional protection by use of 30mA RCBO / RCD these requirements apply to circuits & accessories in domestic applications including; all lighting circuits, all socket outlets up to & including 32A rating, any mobile equipment for use outdoors up to & including 32A rating, all circuits buried an walls or partitions (at less than 50mm depth) and without earthed mechanical protection, all circuits serving a room with a fixed bath or shower, and all circuits passing through a room with a fixed bath or shower. DIVISION OF THE INSTALLATION Chapter 31 requires the installation to be divided into as many circuits as necessary to avoid danger in the event of a fault. Take account of hazards that may arise from the failure of a single circuit e.g. lighting circuit. Prevent unwanted tripping of RCDs due to PE (non-fault) leakage currents and to allow safe testing & maintenance. UNWANTED TRIPPING OF RCDs Chapter 53 provides guidance on ways to maintain power continuity & avoid unwanted tripping. Designers & installers can use an individual RCBO on each circuit, or ensure that any standing leakage current (from equipment- not from fault conditions) is less than 30% of the RCD trip rating e.g. 30% of 30mA. This is in addition to the requirements of Chapter 31 above. OVERVOLTAGE PROTECTION & SURGE PROTECTION DEVICES Individual dwelling units will require surge protection devices where the value of the installation and all of the equipment connected to it justifies the investment in SPD protection see 443.4. AFDDs ADDITIONAL PROTECTION AGAINST ELECTRICAL FIRES Chapter 42 deals with protection against thermal effects and includes regulations that deal with devices that provide protection against the risk of electrical fires i.e. RCDs and AFDDs (arc fault detection devices) AFDDs are recommended for the specific purpose of providing additional protection against fires caused by arc faults in 230v AC final circuits. AFDDs are combined with RCBO technology and should be installed at the origin of each circuit that is being protected i.e. in the consumer unit. The combined technology in AFDDs will provide overcurrent protection, short circuit protection, earth leakage protection & additional protection against fires caused by arc faults. METER TAILS FIXINGS & CABLE ENTRIES Chapter 52 incudes requirements for cables (including meter tails) to be installed to avoid any undue strain on conductors and terminations. Where necessary this will mean clipping / fixing meter tails to make sure that stresses & strains are not placed on the tails inadvertently. This is in addition to any other requirements for protecting meter tails at the point of entry into metal consumer unit enclosures. 2 This guide to Starbreaker consumer units is not intended as a substitute for the standards and regulations that should always be used for all types of electrical installation design & installation work.

S I 0 INSTALLATIONS IN DOMESTIC HOUSEHOLD PREMISES l Lighting circuits in domestic dwellings must be protected by 30mA RCD l All socket outlets should be protected by 30mA RCD* l All circuits serving or passing through a room with a fixed bath or shower should be protected by one or more 30mA RCDs** l All cables buried beneath the plaster surface of the wall or partition (at less than 50mm) should be protected by 30mA RCDs*** REGULATIONS RELATING TO: EXAMPLES ADDITIONAL PROTECTION Upstairs Sockets Downstairs Sockets 411.3.3* 701.411.3.3** 522.6.200 series*** and 560.7.1***** Sockets up to a 32A rating All circuits serving a room containing a fixed bath or shower or circuits not serving but passing through zones 1 or 2 of a room containing a fixed bath or shower. 411.3.4 Luminaire circuits All circuits buried in a wall or partition at less than 50mm and without mechanical protection l All cables concealed in metal stud partitions (common in new builds) should be protected by 30mA RCDs*** l Installations should be divided up into circuits so as to take account of danger and inconvenience caused by a single fault - e.g. such as a lighting circuit**** l Installations should be designed and arranged so as to prevent unwanted tripping of RCDs**** l Safety services such as smoke alarms should be on independent circuits***** Kitchen Sockets Cooker outlet with integral 13A socket Garage Sockets Plus any other sockets up to 32A rated Shower circuit Lighting circuit Heating circuit Ventilation circuit Plus other circuits Upstairs Lighting Downstairs Lighting Plus other lighting circuits Downstairs Lighting Upstairs Lighting Immersion heater Smoke Alarms (Safety service) Burglar Alarm Plus any other circuits 30mA RCDs Taking into account 3.14.1 **** 3.14.2 **** 1 The IET onsite guide also recommends that where metal consumer units are installed into TT systems protection from faults arising from the possibility of mains tails becoming loose and making contact with the metal enclosure by incorporating into the installation a 100mA time delayed (S type) RCCB. 2 Furthermore in all cases the mains tails should be protected at the point of entry into the metal enclosure by use of a mains tails gland to protect against the possibility of mechanical damage and or disturbance that could lead to tails becoming loose and making contact with the metal enclosure. ALL INDEPENDENT CIRCUITS Full metal Main Switch unit with RCBOs SOME INDEPENDENT CIRCUITS Full metal High Integrity unit with RCBOs and MCBs 2 2 HALF INDEPENDENT CIRCUITS Full metal Split Load unit with RCBOs and MCBs NO INDEPENDENT CIRCUITS Full metal Dual RCD unit with MCBs TT SYSTEM All independent circuits & 100mA Time Delay RCD * Regulation 411.3.3 socket outlets with a rated current not exceeding 32A. ** Regulation 701.411.3.3 Additional protection shall be provided for all circuits serving the location and any circuits not serving but passing through zones 1 or 2 of the location by use of one or more 30mA RCD. *** Regulations in the 522.6.200 series, cables concealed in a wall or partition at less than 50mm depth and without earthed mechanical protection e.g. conduit. **** Regulation 314.1 Every installation shall be divided into circuits as necessary to avoid danger and inconvenience in the event of a fault, take account of danger that may arise from the failure of a single circuit such as a lighting circuit, reduce the possibility of unwanted tripping of RCDs etc. **** Regulation 314.2 Separate circuits to be provided for parts of the installation that need to be separately controlled in such a way that those circuits are not affected by the failure of other circuits. ***** Regulation 560.7.1 Chapter 56 circuits for safety services shall be independent of other circuits. In addition Chapter 51 requires designers/installers to take account of all relevant British Standards and manufacturers instructions. For example BS5839 Part 6 is the British Standard for fire detection and alarm systems in dwellings. It states that power supplies to Grade D smoke alarms should be an independent circuit at the consumer unit, or a separately electrically protected local lighting circuit. Regulation 416.2.2 requires that the installed consumer unit achieves IP4X (1mm probe) on the top elevation. All other elevations should be to IP2XC (2.5mm probe). 2 2 1 2 17th EDITION WIRING REGULATIONS INCLUDING AMENDMENT No.3 3

CONSUMER UNITS FOR USE IN DOMESTIC HOUSEHOLD PREMISES l Fully compatible with Arc Fault Detection Devices (AFDD) contact Crabtree technical for further details l Fully compatible with miniature RCBOs with switched neutral as standard l Full metal enclosure, no exposed plastic parts l Low Smoke & Fume paint l Top hinged self closing, stay shut door & metal hinges l Cable entry knockouts on all sides & large square knockouts on the rear l Mains tails cable entry gland for supplementary insulation similar to Class II level of protection to tails l Non combustible cover blanks for unused ways l Plug in MCB & RCBO 25% fewer connections to make - reducing risk of loose connections MINIATURE RCBO l Add or upgrade circuits without removing busbar - no need to disturb adjacent devices - reducing risk of installation errors 4 l RoHS compliant in excess of UK standards l UKAS certified to BS EN 61439-3 l Finger safe, insulated busbar assembly - provides greater personal protection l Permanent factory fitted, non removable busbar shield - can t be lost or left out l Plug in MCB and RCBOs for instant guaranteed connections l Extra height for added wiring space with single module RCBOs l DIN control devices can be fitted in any position along the DIN rail - without affecting any other devices or busbar connections l High capacity neutral & earth terminals l Factory fitted incoming devices for reduced installation time AFDD

MAIN SWITCH UNITS MS Total MCB/ Main Rating RCBO Ways Switch Metal 40A 2* 2 502/2B 63A 2* 2 502/26B 100A 4 4 504/2B 100A 7 7 507/2B 100A 10 10 510/2B 100A 13 13 513/2B 100A 18 18 518/2B *RCBOs are not recommended for use within 502/-- units. 518/2B 515/2963B 515/2883B SPLIT LOAD UNITS 100A SWITCH 63A 30mA RCCB MS Total Main Rating Ways Switch RCCB Metal 100A 4 2 2 504/2263B 100A 7 2 5 507/2263B 100A 7 3 4 507/2363B 100A 7 4 3 507/2463B 100A 7 5 2 507/2563B 100A 10 3 7 510/2363B 100A 10 4 6 510/2463B 100A 10 5 5 510/2563B 100A 10 6 4 510/2663B 100A 10 7 3 510/2763B 100A 15 5 10 515/2563B 100A 15 6 9 515/2663B 100A 15 7 8 515/2763B 100A 15 8 7 515/2863B 100A 15 9 6 515/2963B 100A 15 10 5 515/2163B Both MCBs and RCBOs may be included for final circuit positions that are not protected by resident RCCBs. SPLIT LOAD UNITS 100A SWITCH 80A 30mA RCCB MS Total Main Rating Ways Switch RCCB Metal 100A 7 2 5 507/2283B 100A 7 3 4 507/2383B 100A 7 4 3 507/2483B 100A 7 5 2 507/2583B 100A 10 3 7 510/2383B 100A 10 4 6 510/2483B 100A 10 5 5 510/2583B 100A 10 6 4 510/2683B 100A 12 6 6 512/2683B 100A 15 6 9 515/2683B 100A 15 7 8 515/2783B 100A 15 8 7 515/2883B 100A 15 9 6 515/2983B 100A 15 10 5 515/2183B Both MCBs and RCBOs may be included for final circuit positions that are not protected by resident RCCBs. For consumer unit components see page 12. STARBREAKER ALL METAL CONSUMER UNITS 5

513/236565B HIGH INTEGRITY DUAL RCD UNITS RCCB 1 RCCB 2 MS Total Main 63A 63A Rating Ways Switch 30mA 30mA Metal 100A 8 2 3 3 508/226363B 100A 13 2 6 5 513/226665B 100A 13 2 7 4 513/226764B 100A 13 2 8 3 513/226863B 100A 13 3 5 5 513/236565B 100A 13 3 6 4 513/236664B 100A 13 3 7 3 513/236763B 100A 13 4 5 4 513/246564B 100A 13 4 6 3 513/246663B 100A 13 5 4 4 513/256464B 100A 13 5 5 3 513/256563B 100A 13 6 4 3 513/266463B Total RCCB 1 RCCB 2 MS MCB Main 80A 80A Rating Ways Switch 30mA 30mA Metal 100A 9 1 4 4 509/218484B 100A 13 3 5 5 513/238585B STARBREAKER A LL METAL CONSUMER UNITS 513/2837636B 518/383B Total RCCB 1 RCCB 2 MS MCB Main 80A 63A Rating Ways Switch 30mA 30mA Metal 100A 13 3 5 5 513/238565B 100A 13 2 6 5 513/228665B DUAL RCD SPLIT LOAD UNITS Total RCCB 1 RCCB 2 MS MCB Main 63A 63A Rating Ways Switch 30mA 30mA Metal 100A 13 0 7 6 513/2637636B 100A 13 0 8 5 513/2638635B 100A 13 0 9 4 513/2639634B Total RCCB 1 RCCB 2 MS MCB Main 80A 63A Rating Ways Switch 30mA 30mA Metal 100A 8 0 4 4 508/2834634B 100A 13 0 7 6 513/2837636B 100A 13 0 8 5 513/2838635B 100A 13 0 9 4 513/2839634B RCD INCOMER UNITS RCCB Total MCB Rating Ways RCCB Metal 40A 30mA 2 2 502/343B 63A 30mA 2 2 502/363B 40A 30mA 4 4 504/343B 80A 30mA 4 4 504/383B 40A 30mA 7 7 507/343B 80A 30mA 7 7 507/383B 80A 30mA 10 10 510/383B 100A 30mA 10 10 510/313B 80A 30mA 13 13 513/383B 100A 30mA 13 13 513/313B 80A 30mA 18 18 518/383B 100A 30mA 18 18 518/313B RCD INCOMER UNIT WITH MCBs RCCB Rating MCB 1 (B) MCB 2 (B) Metal 63A 30mA 2 2 6A 32A 502/363GU 6 For consumer unit components see page 12.

516/262B DUAL TARIFF UNITS Main Switch Main Switch Total MCB/ 100A 100A RCBO Ways Tariff 1 Tariff 2 Metal 5 3 2 505/232B 8 3 5 508/232B 8 4 4 508/242B 8 5 3 508/252B 8 6 2 508/262B 11 4 7 511/242B 11 5 6 511/252B 11 6 5 511/262B 11 7 4 511/272B 11 8 3 511/282B 16 6 10 516/262B 16 7 9 516/272B 16 8 8 516/282B 16 9 7 516/292B 16 10 6 516/212B 16 11 5 516/2112B 513/22623B 526/283B MULTI TARIFF UNITS Total Main Main Main MCB/ Switch Switch Switch RCBO 100A 100A 100A Ways Tariff 1 Tariff 2 Tariff 3 Metal 9 4 1 4 509/242124B 14 8 1 5 514/282125B 14 7 1 6 514/272126B SPLIT LOAD DUAL TARIFF UNITS Main Switch MS Total Main RCCB 100A Rating Ways Switch 63A 30mA Tariff 2 Metal 100A 8 2 3 3 508/22623B 100A 13 5 2 6 513/25626B 100A 13 3 6 4 513/23624B Both MCBs and RCBOs may be included for final circuit positions that are not protected by resident RCCBs. Total Main MCB/ Switch MS RCBO Main RCCB 100A Rating Ways Switch 80A 30mA Tariff 2 Metal 100A 13 3 6 4 513/23824B Both MCBs and RCBOs may be included for final circuit positions that are not protected by resident RCCBs. TWO BANK MAIN SWITCH METAL UNITS MS Rating Total Ways LIST No 100A 21 521/2B 100A 27 527/2B 100A 37 537/2B TWO BANK SPLIT LOAD METAL UNITS MS Total Main RCCB Rating Ways Switch 80A 30mA LIST No 100A 20 10 10 520/283B 100A 26 13 13 526/283B 100A 36 18 18 536/283B TWO BANK DUAL RCD SPLIT LOAD METAL UNITS MS Total Main RCCB 1 RCCB 2 Rating Ways Switch 63A 30mA 80A 30mA LIST No 100A 17 0 7 10 517/26383B 100A 23 0 10 13 523/26383B 100A 33 0 15 18 533/26383B STARBREAKER ALL METAL CONSUMER UNITS 7

STARBREAKER METAL CASED SKELETON UNITS - 273mm WIDE FIXING CENTRES DESCRIPTION LIST No MAIN SWITCH METAL CASED SKELETON UNITS 7 Way Main Switch Unit 607/2B l 100A DP Main Switch STARBREAKER AMENDMENT 3 SKELETON CONSUMER UNITS 607/2B 610/2B 613/2B STARBREAKER METAL CASED SKELETON UNITS - 320mm WIDE FIXING CENTRES DESCRIPTION LIST No MAIN SWITCH METAL CASED SKELETON UNITS 10 Way Main Switch Unit 610/2B SPLIT LOAD METAL CASED SKELETON UNITS 8 Way Split Load Unit, 4+4 608/2483B HIGH INTEGRITY METAL CASED UNITS 6 Way High Inegrity Unit, 2+2+2 606/228282B DUAL RCD METAL CASED SKELETON UNITS 6 Way Dual RCD Unit, 3+3 606/2833833B l 100A DP Main Switch l All RCDs have an 80A 30mA rating STARBREAKER METAL CASED SKELETON UNITS - 430mm WIDE FIXING CENTRES DESCRIPTION LIST No MAIN SWITCH METAL CASED SKELETON UNITS 13 Way Main Switch Unit 613/2B SPLIT LOAD METAL CASED SKELETON UNITS 11 Way Split Load Unit, 5+6 611/2583B HIGH INTEGRITY METAL CASED UNITS 9 Way High Integrity Unit, 1+4+4 609/218484B DUAL RCD METAL CASED SKELETON UNITS 9 Way Dual RCD Unit, 5+4 609/2835834B l 100A DP Main Switch l All RCDs have an 80A 30mA rating 8

ASSEMBLED SPINE BACKPLATES MAIN SWITCH Total MCB/ MS Rating RCBO Ways Main Switch LIST No 100A 13 13 H913/2WB 100A 18 18 H918/2WB H913/2WB SPLIT LOAD 100A SWITCH 63A 30mA RCCB MS Rating Total Ways Main Switch RCCB LIST No 100A 10 4 6 H910/2463WB 100A 10 5 5 H910/2563WB 100A 10 6 4 H910/2663WB MCBs and RCBOs may be included for final circuit positions not protected by resident RCCBs. SPLIT LOAD 100A SWITCH 80A 30mA RCCB MS Rating Total Ways Main Switch RCCB LIST No 100A 10 4 6 H910/2483WB 100A 10 5 5 H910/2583WB DUAL RCD SPLIT LOAD Total Main RCCB 1 RCCB 2 MS Rating Ways Switch 80A 30mA 63A 30mA LIST No 100A 8 0 4 4 908/2834634WB MCBs and RCBOs may be included for final circuit positions not protected by resident RCCBs. Starbreaker spine backplates (H) accept both MCBs and single module RCBOs. For use in domestic household premises these spine units must be mounted within a non-combustible enclosure. CONSUMER UNIT PATTRESSES ENCLOSURE PATTRASS LEFT/RIGHT TOP/BOTTOM WIDTH DEPTH ENTRY ENTRY 6 Module 16mm MNSPE6670/1NR MNSPE6584/1NR 9 Module 16mm MNSPE6670/2NR MNSPE6584/2NR 12 Module 16mm MNSPE6670/3NR MNSPE6584/3NR 15 Module 16mm MNSPE6670/4NR MNSPE6584/4NR 20 Module 16mm MNSPE6670/5NR MNSPE6584/5NR For use with all metal consumer units. Allows surface cable entry through rear knockouts and automatically maintains enclosure IP rating to comply with BS7671 and BSEN61439-3 l Cable entry slot may be positioned to suit l Not suitable for use with skeleton units STARBREAKER CONSUMER UNIT PATTRESSES 9

MINIATURE CIRCUIT BREAKERS (6kA) B CURVE C CURVE RATING POLES MODULES LIST NO. LIST NO. 6A 1 1 61/B06 61/C06 10A 1 1 61/B10 61/C10 16A 1 1 61/B16 61/C16 20A 1 1 61/B20 61/C20 32A 1 1 61/B32 61/C32 40A 1 1 61/B40 61/C40 50A 1 1 61/B50 61/C50 Not suitable for use in conjunction with AFDD 61/B16 61/B20 61/B40 STARBREAKER C ONSUMER UNIT OUTGOING DEVICES 61/BM0630 61/BM1030 61/BM3230 61/BM40AFD MINIATURE RCBO 6kA (MCB sized 1 module with switched neutral) RCD B CURVE C CURVE RATING RATING POLES MODULES LIST NO. LIST NO. 6A 30mA 2 1 61/BM0630 61/CM0630 10A 30mA 2 1 61/BM1030 61/CM1030 16A 30mA 2 1 61/BM1630 61/CM1630 20A 30mA 2 1 61/BM2030 61/CM2030 25A 30mA 2 1 61/BM2530-32A 30mA 2 1 61/BM3230 61/CM3230 40A 30mA 2 1 61/BM4030 61/CM4030 Type A - Pure AC and pulsating DC sensitivity ARC FAULT DETECTION DEVICES (AFDD) RCD B CURVE C CURVE RATING RATING POLES MODULES LIST NO. LIST NO. 6A 30mA 2 2 61/BM06AFD 61/CM06AFD 10A 30mA 2 2 61/BM10AFD 61/CM10AFD 16A 30mA 2 2 61/BM16AFD 61/CM16AFD 20A 30mA 2 2 61/BM20AFD 61/CM20AFD 25A 30mA 2 2 61/BM25AFD - 32A 30mA 2 2 61/BM32AFD 61/CM32AFD 40A 30mA 2 2 61/BM40AFD 61/CM40AFD Starbreaker arc fault detection devices are only available combined with Miniature RCBOs and so provide the highest levels of protection applied per circuit. For use in main switch controlled units / applications. ACCESSORIES Blanking Plate 443 Blanking Unit (960º) Blanking Plate twist fit MCB Padlocking Device CSB1 CSBC MCBLD 10

BELL TRANSFORMER DESCRIPTION MODULES LIST No 12V bell transformer 2 303/B12 l With overload protection. 303/B12 301/TD1 302/TD2 DIGITAL TIMESWITCHES DESCRIPTION MOD LIST No 1 Channel Digital Timeswitch 1 301/TD1 1 Channel Digital Timeswitch 2 302/TD1 2 Channel Digital Timeswitch 2 302/TD2 1 Channel Digital Timeswitch + data key facility 2 402/TD1 2 Channel Digital Timeswitch + data key facility 2 402/TD2 1 Channel Digital Astro Timeswitch + data key facility 2 502/TD1 2 Channel Digital Astro Timeswitch + data key facility 2 502/TD2 1-10 min Staircase Timeswitch 1 301/S10 Software USB/S Data Key 4/5DK Data Key 6DK 301/TQ24 303/TQ7 ANALOGUE TIMERS DESCRIPTION MODULES LIST No 24hr Analogue Quartz 1 301/TQ24 24hr Analogue Quartz 3 303/TQ24 7 Day Analogue Quartz 3 303/TQ7 24hr Analogue Synchronous 1 301/TS11 24hr Analogue Synchronous 3 303/TS24 ACCESSORIES Metal Blanking Plate 543 MCB Padlocking Device MCBLD Universal Adaptor (mains tail gland) MTCG32 See page 16 for modular control devices BELL TRANSFORMERS TIME SWITCHES 11

DIMENSIONS l METAL ENCLOSURES STARBREAKER SIZE 4 ENCLOSURE (504/0A) DIMENSIONS A =185mm B =130mm C =104mm 502/26B 502/2B 502/343B 502/363B 502/363GU STARBREAKER SIZE 6 ENCLOSURE (506/0A) DIMENSIONS A =261mm B =188mm C =121mm 504/2B 504/383B 504/343B A STARBREAKER SIZE 9 ENCLOSURE (509/0A) STARBREAKER SIZE 12 ENCLOSURE (512/0A) DIMENSIONS A =261mm B =242mm C =121mm DIMENSIONS A =261mm B =292mm C =121mm C B 504/2263B 505/232B 507/2B 507/383B 507/343B 507/2263B 507/2283B 507/2363B 507/2383B 507/2463B 507/2483B 507/2563B 507/2583B 508/232B 508/242B 508/252B 508/262B 510/2B 510/313B 510/383B STARBREAKER SIZE 15 ENCLOSURE (515/0A) STARBREAKER SIZE 20 ENCLOSURE (520/0A) DIMENSIONS A =261mm B =343mm C =121mm DIMENSIONS A =261mm B =438mm C =121mm 508/22623B 508/226363B 508/2834634B 509/242124B 510/2363B 510/2383B 510/2463B 510/2483B 510/2563B 510/2583B 510/2663B 510/2683B 510/2763B 511/242B 511/252B 511/262B 511/272B 511/282B 513/2B 513/313B 513/383B 509/218484B 513/226764B 513/226863B 513/23624B 513/236565B 513/236664B 513/236763B 513/23824B 513/246564B 513/246663B 513/25626B 513/256464B 513/256563B 513/2637636B 513/2638635B 513/2639634B 513/266463B 513/2837636B 513/2838635B 513/2839634B 514/272126B 514/282125B 515/2163B 515/2183B 515/2563B 515/2663B 515/2683B 515/2763B 515/2783B 515/2863B 515/2883B 515/2963B 515/2983B 516/2112B 516/212B 516/262B 516/272B 516/282B 516/292B 518/2B 518/313B 518/383B 512/2683B 513/226665B 513/238585B 513/238565B 513/228665B CONSUMER UNIT PATTRESSES l ENCLOSURE PATTRASS LEFT/RIGHT TOP/BOTTOM WIDTH DEPTH ENTRY ENTRY 6 Module 16mm MNSPE6670/1NR MNSPE6584/1NR 9 Module 16mm MNSPE6670/2NR MNSPE6584/2NR 12 Module 16mm MNSPE6670/3NR MNSPE6584/3NR 15 Module 16mm MNSPE6670/4NR MNSPE6584/4NR 20 Module 16mm MNSPE6670/5NR MNSPE6584/5NR For use with Crabtree All Metal consumer units. Allows surface cable entry through rear knockouts and automatically maintains enclosure IP rating to comply with BS7671 and BSEN61439-3 and the IET onsite guide. DIMENSIONS STARBREAKER TOP/BOTTOM CABLE ENTRY 16 B 255 LEFT/RIGHT CABLE ENTRY B Cable entry slot line up with rear knockouts, the minimum number of knockouts only should be removed for cable entry. Suitable for use with trunking systems. 16 12

DIMENSIONS TWO BANK UNITS STARBREAKER SIZE 24 ENCLOSURE (524/2A) DIMENSIONS A =506mm B =295mm C =121mm 517/26383B 520/283B l STARBREAKER SIZE 30 ENCLOSURE (530/2A) A DIMENSIONS A =506mm B =345mm C =121mm 523/26383B 526/283B STARBREAKER SIZE 40 ENCLOSURE (540/2A) DIMENSIONS A =506mm B =440mm C =121mm 533/26383B 536/283B C B SPINE BACKPLATE ASSEMBLIES (White PVC Cover) B C STARBREAKER 15 MODULE SPINE BACKPLATE UNIT (10W & 13W) DIMENSIONS A =235mm B =335mm C =106mm D =180mm E =319.5mm H910/2463WB H910/2483WB H910/2563WB H910/2583WB H910/2663WB H913/2WB A UNIT FIXING POSITIONS D STARBREAKER 20 MODULE SPINE BACKPLATE UNIT (18W) DIMENSIONS A =235mm B =448mm C =106mm D =180mm E =435mm H918/2WB E STARBREAKER 15 MODULE DRCD (8W) DIMENSIONS A =205mm B =333mm C =106mm D =140mm E =320mm 908/2834634B STARBREAKER INCOMING DEVICES AND ENCLOSURES ENCLOSURES MODULAR WIDTH ALL METAL 4 504/0A 6 506/0A 9 509/0A 12 512/0A 15 515/0A 20 520/0A 24 524/0A 30 530/0A 40 540/0A FLUSH MOUNTING KIT MODULAR WIDTH ALL METAL 6 506/FLA 9 509/FLA 12 512/FLA 15 515/FLA 20 520/FLA 24 524/FLA 30 530/FLA 40 540/FLA REPLACEMENT COVERS FOR 5 SERIES ENCLOSURES MODULAR WIDTH ALL METAL 6 506/LID 9 509/LID 12 512/LID 15 515/LID 20 520/LID DOUBLE POLE MAIN SWITCH DISCONNECTORS RATING MODULAR WIDTH LIST No 40A 2 40/M12* 63A 2 63/M12* 100A 2 100/MI2* 100A 2 100/2MT** * Used within main switch only and split-load applications ** Used within high integrity and dual RCD applications RESIDUAL CURRENT CIRCUIT BREAKERS RATING MODULAR WIDTH LIST No 40A 30mA 2 340/030 63A 30mA 2 363/030 80A 30mA 2 380/030 100A 30mA 2 310/030 63A 30mA 3 363/S030* 80A 30mA 3 380/S030* * Dedicated as a split-load RCCB (3 modules) AM 3 UPGRADE / REPLACEMENT COVERS FOR 8 SERIES ENCLOSURES MODULAR WIDTH LIST No 6 806/LID255G 9 809/LID255G 12 812/LID255G 15 815/LID255G 20 820/LID255G D IMENSIONS STARBREAKER 13

ELECTRIUM SALES LIMITED A SIEMENS COMPANY Commercial Centre, Lakeside Plaza, Walkmill Lane, Bridgtown, Cannock WS11 0XE. email: info@electrium.co.uk Web: www.electrium.co.uk UK SALES Telephone: 01543 455010 Facsimile: 01543 455011 email: crabtree.sales@electrium.co.uk TECHNICAL Telephone: 01543 438310 Facsimile: 01543 438311 email: crabtree.technical@electrium.co.uk EXPORT SALES Telephone: +44 1543 455049 Facsimile: +44 1543 455048 email: export@electrium.co.uk Although every effort has been made to ensure accuracy in the compilation of the technical detail within this publication, specifications and performance data are constantly changing. Latest details can be obtained from Crabtree. Publication No. B2201b 7/18 @ElectriumNews or download the APP