V8-80HS-1 SERIES OF HIGH-SPEED MOTORIZED ZOOM LENSES

Similar documents
Lens Backfocus & Adjustment Procedures. 1. Backfocus

VN-DSX-INT ViconNet ver 4/DSX Integration Software

Product Specification. S10-CH Mini Camera Dome

LTC 3783/50 Zoom Lens

INSTRUCTION MANUAL XX166-02

IR-Corrected Zoom and Varifocal Lenses

IR Varifocal IP66 Weatherproof Cameras

1/3-in. format color high-resolution IP camera; 540 TVL; 24 VAC or PoE; NTSC/PAL; ViconNet version 5 software VN-856DNV5/ VN-856DNV5-C

VPC-64/ VPX-64 VIDEO POLE CAMERA OPERATION MANUAL

TL1250 page 5. TL410 page 2. TL936 page 8. 4K Motorized Lenses Up to 12 Megapixel Resolution Superior NIR Correction Compact Size

VADDIO /CANON BU-SERIES PTZ CAMERAS

Please refer to the table below for the features of individual camera models.

INSTRUCTION MANUAL. Security Camera. Indoor/Outdoor Color Camera w/ Night Vision. Version 1.0. now you can see. Model# VU5

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

Black & White Camera Kit with Multiplexer Video Surveillance System

MODEL 9266 LITTLE LEAGUE BASEBALL SCOREBOARD. Instruction Manual

MODEL V1500X-SCCS-1 SYSTEM CONTROLLER QUICK GUIDE

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

VBAR 270. User Manual. Version 1.2

Checker is the sensor. CheckMate is the software that runs on your PC. You use CheckMate to set up Checker mm mm 4.

CF /BF SERIES CAMERAS

Unpacking. Installation

Kramer Electronics, Ltd. USER MANUAL. Model: WP-210E. XGA Line Driver

Power Supply (48Vdc, 2.5A)

Camera Installation Manual Ver 1.0. Pan, Tilt and Zoom Dome Camera / PTZ

KTC-XP1 UltraView Camera With Xposure Technology

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

LaserLyte-Flex Red & Green Alignment System

Weatherproof IR Color Day/Night Cameras

Colour Observation Camera

KTC-115CC, -215CC, -240CCE Compact Cameras

Data Sheet. V910 Impact-Resistant IP and Analog Camera Dome Series. Durable Construction and Easy Installation

WallVIEW PTZ Systems WallVIEW 50i PTZ, WallVIEW 100 PTZ and WallVIEW 70 PTZ Pan/Tilt/Zoom Camera Systems

Full HD Speed Dome IP Camera

MINIATURE FIXED-POSITION CAMERA DOMES

Nearus USB2.0 Camera Manual NU-350-USB2PTZ-B

THE INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND SHOULD CONFORM TO ALL LOCAL CODES.

ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV

DAY AND NIGHT COLOR CAMERA

DFP Series Fiber Photoelectric Amplifiers

Installation and User Guide

INSTALLATION MANUAL. ST-BTWD650IR2812 B or W Weatherproof Day/Night Infrared Color Camera

to 48V DC Power Supply

HIGH BAY PASSIVE INFRARED OCCUPANCY SENSOR

MIC400 Aluminum PTZ Camera

232iLM Keypad Installation and Programming Instructions

ACC484TP(X) 1/3 HIGH RESOLUTION FULL-FEATURED COLOR CAMERA. Features:

LED SPIDER MOVING HEAD LIGHT

General-Purpose Photoelectric Sensor

Roughneck V920D Series Camera Domes XX Quick Guide


Infrared Dome CCD Camera User Manual

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

Basketball Shot Clock Set LX2180 Manual

AC-43 Accelerometer. User Manual

Bluetooth Ceiling Fan Control with App Owner's Manual

SLM Series Slot Sensors

OPERATION MANUAL FOR MICROPLATE ORBITAL SHAKER SERIES VP 325

ACCESSORY 2 - MONITOR INSTRUCTION MANUAL

Operating instructions. Switching amplifier DN0210 DN / / 2015

INTERCOM AMBULANCE/RESCUE VEHICLE MODEL ICA100 SURFACE MOUNT SERIES MODELS ICA200, ICA300 FLUSH MOUNT SERIES MODELS ICA400, ICA500

SN680D-WNIR Network PTZ Dome XX Quick Guide

Iris Innovations. IM-PTZ-16 Micro-PTZ Camera. Iris Innovations

What s in the Box? REAR VIEW SAFETY

ACT-1B Series Panel Tachometer

SUM-40 OPERATING MANUAL. Ma0 DYNAMIC STRUCTURES AND MATERIALS, LLC REV

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

Home Automation, Inc. Model 32A00-1. OmniTouch Touchscreen

APMC4110 POWERED PMC CARRIER STANDALONE PCI INTERFACE MODULE

User Guide. Control Box. RoscoLED TM.

ICS150 Series Camclosure Camera System MINI DOME, IN-CEILING, WDR, LOWLIGHT, HIGH RES, STD RES

845G. Description. Features. Specifications

AD-7830 Servo Amplifier

Intelligent Channel Bank Shelf

ZEISS Compact Prime CP.3 and CP.3 XD Mount Change Instructions

Installation/ Operation Manual

Control Unit with Double Save/Recall, Cross-line and Zoom Display. Product No. OP

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

SDI Speed Dome Camera OSD Menu

MC /3-Inch Monochrome Camera

User Manual. Binocular Zoom Stereo Microscope with Boom Stand. MicroscopeNet.com

On-Screen-Menu Clear, intuitive and easy. Keep a constant overview of the current functions, settings and options.

Installation/Operating Instructions 220V VCB Silhouette/Series E Electric Video Conferencing Background by Draper

Fixed Color Cameras Installation Manual INTRODUCTION These instructions cover the American Dynamics ADCA470 and ADCA330 series of color cameras Read a

Fujitsu Stylistic ST4000 Series TABLET DOCK USER S GUIDE

Electric Actuators and Control Systems. Established Leaders in Valve Actuation AD-8140 & AD Instruction Manual. Publication P971E Issue 08/09

Varifocal Lenses. CCTV Varifocal Lenses. Certifications and Approvals. Functions. Installation/Configuration Notes.

EVERSAN. Instruction Manual MODEL 9007/9008 TENNIS SCOREBOARD. Address: 34 Main Street, Whitesboro, NY 13492

HuddleCamHD 10X-USB2

ICS090 Series Camclosure Camera System INDOOR, MINI DOME, SURFACE MOUNT/IN-CEILING, WDR, HIGH RES, STD RES

Software Quick Manual

1519L Multifunction 15-inch Desktop Touchmonitor

Compact, Low Profile High Rendering, 100% Diffusion

Custom Controller Installation Instructions

Flat-Field Mega-Pixel Lens Series

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

G500 SERIES MICROSCOPE OPERATION MANUAL For use with MFR# G502, G502T, G504, G504T, G505, G505T.

Transcription:

X684 V8-80HS-1 SERIES OF HIGH-SPEED MOTORIZED ZOOM LENSES Copyright 2000 Vicon Industries Inc. All rights reserved. Product specifications subject to change without notice. Vicon and its logo are registered trademarks of Vicon Industries Inc. VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788 TEL: 631-952-CCTV (2288) FAX: 631-951-CCTV (2288) TOLL FREE: 800-645-9116 24-Hour Technical Support: 800-34-VICON (800-348-4266) UK: 44/(0) 1489-566300 INFOFAX: 800-287-1207 WEB: www.vicon-cctv.com Vicon part number 8006-8684-02-00 Section 15 Rev 100

Introduction The information in this manual covers the installation, operation and maintenance of the V8-80HS-1 Series of High-Speed Motorized Zoom Lenses. These units should be installed by a qualified technician using approved materials in conformance with national, state and local electrical codes. Read these instructions through completely before attempting installation. The V8-80M-HS-1 lens features motorized zoom, focus and iris functions. This model is appropriate for indoor use. The V8-80MS-HS-1 lens features motorized zoom, focus, and iris and is equipped with a neutral-density spot filter to permit use in a wide range of lighting conditions. With this lens, a sensitive camera can operate effectively in both partial darkness and high-light-level conditions. The V8-80MS-HS-P-1 has the same features, but it adds preset-position potentiometers to the zoom and focus controls. The V8-80AC-HS-1 lens has the same features as the V8-80MS-HS-1 plus video-drive autoiris operation. This additional feature provides optimum viewing contrast regardless of light conditions or brightness variations within the scene. In the AC lens, the iris is controlled by a stepping motor, which is virtually unaffected by vibration or operating position. The microcomputer iris control provides precise responsive iris operation. The V8-80AC-HS- P-1 has the same features, but it adds preset-position potentiometers to the zoom and focus controls. Refer to Table 1 for a full list of models. The preset-position option consists of precision potentiometers built into the lens that provide position feedback information for zoom and focus to an appropriate control unit. Table 1 V8-80HS-1 Models Model Product Code Description V8-80M-HS-1 5863 Motorized zoom, focus and iris V8-80MS-HS-1 5864 Motorized zoom, focus and iris; neutral-density spot filter V8-80MS-HS-P-1 5864-01 Motorized zoom, focus and iris; neutral-density spot filter; preset position potentiometers V8-80AC-HS-1 5865 Motorized zoom, focus; video-drive autoiris; neutral-density spot filter V8-80AC-HS-P-1 5865-01 Motorized zoom, focus; video-drive autoiris; neutral-density spot filter; preset position potentiometers X684 Rev 100 V8-80HS-1 Zoom Lenses Introduction 1

Notes 2 Introduction X684 Rev 100 V8-80HS-1 Zoom Lenses

Installation Unpacking and Inspection All Vicon equipment is tested and inspected before leaving the factory. It is the carrier s responsibility to deliver the equipment in the same condition as it left the factory. Inspect the cartons upon delivery and, if damage is present, make detailed notes on the carrier s bill. Then obtain the carrier s agent signature and file a damage claim as soon as possible. Open the cartons and inspect the equipment for damage. Save the cartons and packing material. If damage is present, contact the carrier and file a damage claim immediately. If the equipment must be returned for repair, refer to the Shipping Instructions Section of this manual. Mounting the Lens Do not exceed the maximum recommended distances between a lens and its control unit. Note: The front element of a zoom lens moves in and out as the lens focus is changed. The closest focusing position corresponds to the greatest extension of the lens. When installing a lens in a housing, make sure that the lens is fully extended. Allow ¼-inch (6 mm) of clear space between the extended lens and the window. Caution: Control units having the three-position distance switch MUST NOT be set for longer than recommended distances or the lens may be seriously damaged. Caution: Do not mount an autoiris lens on a camera that is installed on an autopanning unit. Such use causes excessive wear, as the iris mechanism constantly compensates for different light levels. 1. Screw the lens firmly into the mount on the camera (V8-80HS-1 lenses have C mounts). If the lens is not oriented correctly after screwing it into the camera, proceed with step 2. 2. Rotate the lens in either direction against the friction clutch in the lens mount to obtain the best installation angle. Wiring the M and MS Lenses The M and MS lenses are supplied with AMP Miniature Rectangular (MR) connectors for zoom, focus, iris, and preset functions. The lens has a single cable with multiple conductors. The number of conductors depends on the lens model. Connect cables from the lens control to the MR mating connector in the accessory pack. Lenses without the preset function are supplied with a 6-pin connector, while lenses with presets have a 9-pin connector. The wiring of both connectors is shown in Figure 1. Tables 2 and 3 show the color-coding of the cables from the lens. X684 Rev 100 V8-80HS-1 Zoom Lenses Installation 3

Table 2 Table 3 Wiring for M and MS Lenses Wiring for M and MS Lenses with Presets Pin Number Wire Color Function Pin Number Wire Color Function 1 White Iris drive 1 White Iris drive 2 Red Zoom drive 2 Red Zoom drive 3 Green Focus drive 3 Green Focus drive 4 Black Common 4 Black Lens common 5 - Not used 5 Gray Potentiometer return (-) 6 White/Black Ground or shield 6 Brown Potentiometer supply (+) 7 Blue Zoom wiper 8 Yellow Focus wiper 9 White/Black Ground or shield Figure 1 Connector Diagram, M and MS Lenses 4 Installation X684 Rev 100 V8-80HS-1 Zoom Lenses

Wiring the Autoiris (AC) Lens AC lenses have two cables. One cable has a AMP MR (Miniature Rectangle) connector. This provides connection for the zoom, focus and preset controls. Lenses without the preset function are supplied with a 6-pin connector, while lenses with presets have a 9-pin connector. The wiring of both connectors is shown in Figure 2. Table 4 shows the color-coding of the control cables and Table 5 shows the color coding for the control and preset cables. The second cable is connected directly to the video drive connection on the camera and does not have a connector. Most cameras provide either a screw terminal connector or a spring-loaded pushbutton connector on the back of the camera for video-drive autoiris lenses. If the camera requires a separate connector for the autoiris cable, it is supplied with the camera and should be wired according to the instructions provided with the camera. The cable controlling the autoiris drive in an AC lens may consist of three or four conductors and a shield. For proper operation, the shield of the cable MUST be grounded to the same pin as the black (common) conductor. If the autoiris cable has four conductors, the green conductor is not used and may be cut off. Table 6 shows the coding for the autoiris cable. Table 4 Table 5 Wiring for AC Lenses Wiring for AC Lenses with Presets Pin Number Wire Color Function Pin Number Wire Color Function 1 - Not used 1 - Not used 2 Red Zoom drive 2 Red Zoom drive 3 Green Focus drive 3 Green Focus drive 4 Black Common 4 Black Lens common 5 - Not used 5 Gray Potentiometer return (-) 6 White/Black Ground or shield 6 Brown Potentiometer supply (+) 7 Blue Zoom wiper 8 Yellow Focus wiper 9 White/Black Ground or shield Figure 2 Connector Diagram, AC Lenses Table 6 Wiring for Autoiris Cable of AC Lenses Wire Color Function Red 9 10 VDC White Video X684 Rev 100 V8-80HS-1 Zoom Lenses Installation 5

Black Ground Zoom and Focus Adjustment Procedure The following procedure should be used to obtain the best results in setting optical and mechanical focus. 1. Adjust the zoom function to the maximum telephoto setting, then focus on a convenient distant object. Readjust the zoom to the maximum wide angle setting and check the focus. The focus should remain reasonably sharp. If it does not, the back focus (mechanical focus) of the camera must be adjusted according to steps 2 and 3. 2. Adjust the back focus by positioning the camera 25-50 feet (7.6-15 m) from a flat vertical surface suitable for focusing. (A textured wall or a page of a newspaper are good focusing targets.) Open the iris to its maximum. If the lens has an autoiris, reduce the lighting to open the iris up to its maximum. This is necessary to obtain the most accurate back focus adjustment. 3. Zoom in to the maximum telephoto position and focus the lens. Zoom out, watching the focus on the monitor. If the image goes out of focus, adjust the back focus. Repeat the process until optimum focus is obtained. Lock the back focus mechanism in place. Zoom Speed Control: The time required to zoom from maximum wide angle to maximum telephoto settings is adjustable from 2 to 7 seconds. To make the adjustment, remove the cap over the potentiometer and turn to adjust the speed. Turn the potentiometer clockwise to increase the speed. Refer to Figure 3. Focus Speed Control: The time required to adjust focus from the closest setting to infinity is adjustable from 2 to 8 seconds. To make the adjustment, remove the cap over the potentiometer and turn it to adjust the speed. Turn the potentiometer clockwise to increase speed. Refer to Figure 3. Iris Speed Adjustment Iris speed is adjustable on the MS lens, which provides remote manual iris control. The AC lens, which features autoiris operation, does not have an iris speed adjustment. The iris speed of the MS lens can be adjusted from full open to closed in from 1.5 to 8 seconds. Remove the cap over the potentiometer (refer to Figure 3) and turn the potentiometer to adjust the speed. Turning it clockwise increases the speed. Autoiris Adjustment Autoiris (AC) zoom lenses must be adjusted for optimum picture quality. Although two adjustments, automatic light control (ALC) and video level (LEVEL), are provided on the lens, the level control is preset at the factory and should not be readjusted unless other methods of optimizing the picture are unsuccessful. Before making any attempt to adjust the lens, perform the following monitor setup procedure: turn the BRIGHTNESS and CONTRAST controls on the monitor fully counterclockwise, then turn them back to approximately midscale. These controls vary from monitor to monitor, but these settings are adequate for initial adjustment. Automatic Light Control (ALC) This control adjusts the contrast level of the picture. The limits of the adjustment are labelled P (peak) and A (average), and the control is set at average at the factory. When making an adjustment, turn the potentiometer a 6 Installation X684 Rev 100 V8-80HS-1 Zoom Lenses

little at a time. If the contrast is too strong, turn the potentiometer clockwise, toward P; if the contrast is too weak, turn the potentiometer counterclockwise, toward A. Video Level (LEVEL) The level control is preset at the factory for optimum performance, so normally no adjustment is required. Adjusting this control when it is not necessary may spoil the picture quality. If all other adjustments fail to produce a satisfactory picture, adjust the LEVEL potentiometer. The adjustment limits are low (L) and high (H). Note: When making an adjustment, turn the potentiometer a little at a time. 1. Set the camera AGC to OFF. 2. Remove the rubber cap from the potentiometer and adjust it. If the contrast is too strong, turn the potentiometer counterclockwise, toward L; if the contrast is too weak, turn the potentiometer clockwise, toward H. 3. Reset the camera AGC to ON. Figure 3 Lens Adjustment Location X684 Rev 100 V8-80HS-1 Zoom Lenses Installation 7

Shipping Instructions Use the following procedure when returning a unit to the factory: 1. Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name of the Vicon employee who issued the R.A. Vicon Industries Inc. 89 Arkay Drive Hauppauge, NY 11788 Phone: 631-952-CCTV (2288); Toll-Free: 1-800-645-9116; Fax: 631-951-CCTV (2288) For service or returns from countries in Europe, contact: Vicon Industries (U.K.) Ltd Brunel Way Fareham, PO15 5TX United Kingdom Phone: 44/(0)1489/566300; Fax: 44/(0)1489/566322 2. Attach a sheet of paper to the unit with the following information: a. Name and address of the company returning the unit b. Name of the Vicon employee who issued the R.A. c. R. A. number d. Brief description of the installation e. Complete description of the problem and circumstances under which it occurs f. Unit s original date of purchase, if still under warranty 3. Pack the unit carefully. Use the original shipping carton or its equivalent for maximum protection. 4. Mark the R.A. number on the outside of the carton on the shipping label. 8 Shipping Instructions X684 Rev 100 V8-80HS-1 Zoom Lenses

Technical Information OPTICAL Focal Length: Effective Aperture Range: 8-80 mm (10X). M Lens: f/1.4.- f/22. MS, AC Lens: f/1.4.- f/360. Horizontal Angle of View: Wide: 45.9. Telephoto: 4.6. Vertical Angle of View: Wide: 34.4. Telephoto: 3.5. Diagonal Angle of View: Wide: 57.6. Telephoto: 5.7. Minimum Focusing Distance: Flange Focal Distance: 4.9 ft. (1.5 m). 0.690 in. (17.5 mm). ELECTRICAL M and MS Lenses Motor Drive Voltage: Operating Current: Connectors: Cable Requirements: AC Lenses Input Voltage: Operating Current: Connectors: 6-12 VDC. Zoom: 40 ma max. Focus: 40 ma max. Standard lens: Vicon part number 8000-9800-00 on pendant cable. (Mating connector 8000-9736-00 supplied.) Preset lens: Vicon part number 8000-9801-00 on pendant cable. (Mating connector 8000-9645-00 supplied.) Without presets: 4 conductor, shielded. With presets: 8 conductor, shielded. Iris: 8 16 VDC. Zoom and focus: 7.5 VDC. Iris: 40 ma max. Zoom and focus: 43 ma max. per motor. Iris: 3-conductor shielded pendant cable supplied for iris. Zoom and focus: Standard lens; Vicon part number 8000-9800-00 on pendant cable. (Mating connector 8000-9736-00 supplied.) Preset lens; Vicon part number 8000-9801-00 on pendant cable. (Mating connector 8000-9645-00 supplied.) X684 Rev 100 V8-80HS-1 Zoom Lenses Technical Information 9

Cable Requirements: Video: Without presets: 3 conductor, shielded. With presets: 7 conductor, shielded. Requires video from 0.5 V to 1.0 V peak-to-peak for proper iris operation. OPERATIONAL Duty Cycle: Iris Speed: Focus Speed Range: Zoom Speed Range: Intermittent. M, MS Lens: 1.5 8 sec at 8 VDC, adjustable. AC Lens: 2.0 sec, not adjustable. 2-8 sec, adjustable. 2-7 sec, adjustable. MECHANICAL Dimensions: Weight: Mount Type: Filter Threads: Maximum Lens Penetration into Camera: Mounting Hole: Height: 2.6 in. (66 mm). Width: 3.0 in. (76 mm). Length: 4.7 in. (119 mm). Optical center to bottom: 1.3 in. (34 mm). Distance from bottom mounting hole to mounting flange: 1.2 in. (31 mm). 1.43 lb (0.65 kg). C mount. Diameter: 58 mm. Pitch: 0.75 mm. 0.28 in. (7.1 mm). ¼-20 thread x ¼ in. deep. ENVIRONMENTAL Operating Temperature: Storage Temperature: Storage Humidity: 14-122 F (-10 50 C). -40 to 150 F (-40 to 65 C). Up to 90% relative, noncondensing. 10 Technical Information X684 Rev 100 V8-80HS-1 Zoom Lenses