PS-3005P Programmable DC Power Supply

Similar documents
USER MANUAL. RND 320-KA3000 Series

Multiple Channel Digital Control and Programmable DC Power Supply Model: , , and

TP3005P EN PROGRAMMABLE DC LAB POWER SUPPLY 0-30V/ USB 2.0

User s Manual PROGRAMMABLE DC POWER SUPPLY

Keysight U8030 Series Triple-Output DC Power Supplies

99 Washington Street Melrose, MA Phone Toll Free Visit us at

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

BENCHTOP INSTRUMENT. Programmable Switching DC Power Supply Operation Manual V1.0

80W (16V/5A) Power Supply with USB Output. User Manual

1. PRODUCT INTRODUCTION Description 1-2. Feature...

ETHOS Auto Ranging Digital Multimeter

Series Watt DC Power Supplies

NTP-6621 / 6631 / 6661 SWITCHING MODE POWER SUPPLY with USB REMOTE CONTROL

Economy Single Channel Output DC Power Supply

User's Guide. Model W 3-in-1 Switching DC Power Supply

User s Manual PROGRAMMABLE DC POWER SUPPLY APS-7303/7303L/7305/7305L

Laboratory Switch Mode Power Supply Series. Instruction Manual

An ISO 9001 Company. KLP POWER SUPPLY

USER S MANUAL Linear Programmable DC Power Supply APS

1-36V, 0-3A DC Power Supply

DC POWER SUPPLY. Model: PW-3063R / PW-4063R

SIM-9106/9303 High Current Switching Mode Power Supply with C.C., C.V., Remote Control & Sensing User Manual

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Table of Contents. 3.1 Front/Rear Panel and User Interface Front Panel Rear Panel User Interface...

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

Operating Instructions. LSP-KONSTANTER Series 32K Laboratory Power Supply 8/10.13

Programmable Power Supply

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

High Precision Quad Output DC Power Supply

OPERATING MANUAL FOR THE 30KV A.C. TEST SET P123. Bicotest High Voltage Products Ltd

Multi Range DC Power Supply

DC Power Supply. GPD-X303S Series USER MANUAL GW INSTEK PART NO. 82PD-433S0M01 ISO-9001 CERTIFIED MANUFACTURER

DC Power Supply. GPD-3303 Series USER MANUAL GW INSTEK PART NO.

CIRCUIT-TEST. Switching Mode Power Supply with USB Remote Control PSC VDC / 5A PSC VDC / 3A PSC VDC / 1.

2016 SIGLENT TECHNOLOGIES CO.,LTD

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

OPERATING INSTRUCTION

Intercel esam Router

Model DCP42 160W Laboratory Grade Constant Power, Switching Mode Power Supply

Mini Digital Multimeter

Autoranging True RMS Multimeter User Manual

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

±15 V Current-Limited Power Supply

RIGOL. Quick Guide. DP800A Series Programmable Linear DC Power Supply. Aug RIGOL Technologies, Inc.

LABORATORY GRADE REMOTE PROGRAMMING SWITCHING MODE DC REGULATED POWER SUPPLIES SDP / 3636 / User Manual

Features. Conducted Emission. Radiated Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors.

SAFETY TERMS AND SYMBOLS

Features. Conducted. Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Overvoltage Protection. Phase Loss.

Sorensen SG Series kw V A. Programmable Precision High Power DC Power Supply

BENCHTOP INSTRUMENT. Programmable DC Power Supply Operation Manual V1.0

1 INSTRUCTION 2 SPECIFICATIONS 3 USER GUIDE 1. Output voltage 0-32V Output current. 0-1A( CA19101DH) 0-3A( CA19103DH) 0-5A( CA19105DH) Source effect

Features. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Output Connectors. Overvoltage Protection. Over Temperature Protection

AutoRanging Digital MultiMeter

Model 9129B Triple Output Programmable DC Power Supply USER MANUAL

Sorensen SG Series - Water Cooled kw V A. Programmable Precision High Power DC Power Supply

Series MV2000 MEDIUM VOLTAGE HIGH CURRENT POWER SUPPLIES

Mini Digital Multimeter

MTP INSTRUCTION MANUAL

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

Digital Clamp Meter User Manual

3700 SERIES USER MANUAL

L300 user manual. Programmable DC Electronic Load CONTENTS. Electronic Load Software CAUTION...2 SAFETY NOTES...2

User Guide True RMS Multimeter Extech EX205T

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

DC Power Supply SPD-3606 USER MANUAL

AIM & THURLBY THANDAR INSTRUMENTS

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

2260B Series Multi-Range Programmable DC Power Supplies Quick Start Guide A Greater Measure of Confidence A Tektronix Company

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

DP700 Series. Programmable Linear DC Power Supply. Batter Fly s.r.l. - Tel

AIM & THURLBY THANDAR INSTRUMENTS

EPS Stromversorgung PSE U. Operating Guide. DC High Efficiency Power Supply

MX100T & MX100TP. Triple Output Multi-Range DC Power Supply INSTRUCTION MANUAL

HCS-3200/3202/3204 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Autoranging Mini Multimeter

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems

Test Report S

User's Guide. Model High Precision Quad Output DC Power Supply

ODP Series Linear Programmable DC Power Supply User Manual

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

ODP3031 Linear Programmable DC Power Supply User Manual

PS U Series W to 3000 W. Programmable DC Power Supplies THE POWER TEST EXPERTS.

USER S GUIDE Programmable DC Power Supply Model EA-PSI 6000 Series

USER MANUAL 8500 SERIES DC ELECTRONIC LOADS. Models 8500, 8502, 8510, 8512, 8514, 8518, 8520, 8522, 8524 & 8526

Mini Digital Multimeter Model MN15. User's Guide

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

ODP Series Dual Output Linear Programmable DC Power Supply User Manual

MX180T & MX180TP. Triple Output Multi-Range DC Power Supply INSTRUCTION MANUAL

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

USER MANUAL 8500 SERIES DC ELECTRONIC LOADS

Programmable Switching DC Power Supply

AIM & THURLBY THANDAR INSTRUMENTS

USER MANUAL 8500 SERIES DC ELECTRONIC LOADS

Model R5010. TRMS Digital Multimeter. Instruction Manual

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

EPS Power Supply

Programmable DC Electronic Loads

Model A Mini AC/DC Clamp Meter. User's Guide

Transcription:

PS-3005P Programmable DC Power Supply (0-30V, 0-5A) Part of the PS-3000 Series User Manual Head Office - Wavecom Instruments Pty Ltd 257 Grange Road, Findon SA 5023 Phone: (+61) 08 8243 3500 Fax: (+61) 08 8243 3501 Email: sales@wavecom.com.au Web: www.wavecom.com.au Perth Unit 2/17 Casino Street, Welshpool, WA Phone: (+61) 08 9353 1943 Fax: (+61) 08 9353 4319 Email: saleswa@wavecom.com.au Web: www.wavecom.com.au Melbourne Office 772A Station Street, Box Hill, Victoria 3128 Phone: 1300 793 301 Fax: (+61) 03 9897 4766 Email: salesvic@wavecom.com.au Web: www.wavecom.com.au

Table of Contents SAFETY INSTRUCTIONS...3 Safety Symbols... 3 Safety Guidelines... 4 AC Input... 4 Environmental Requirements... 4 Fuse... 5 OVERVIEW...5 Main Features... 5 Front Panel Overview... 7 Displays...8 Status Indicators... 8 Front Panel Buttons and Terminals... 9 Rear Panel Overview... 11 OPERATION... 12 Power Up...12 Output ON/OFF... 13 Beep ON/OFF... 13 Front Panel/Key Lock... 14 Setting Output Parameters... 14 Save/Recall Setup... 16 REMOTE CONTROL... 17 FAQ... 19 SPECIFICATIONS... 20 Page 2

SAFETY INSTRUCTIONS This chapter contains important safety instructions that you must follow when operating the PS-3000 series and when keeping it in storage. Read the following before any operation to ensure your safety and to keep the product in the best condition. Safety Symbols These safety symbols may appear in this manual or on the series. WARNING DANGER High Voltage Earth (Ground) Terminal Page 3

Safety Guidelines Do not block or obstruct the cooling fan and side vent openings. Provide free space of at least 2.5cm. Avoid rough handling to prevent damages. Avoid discharging static electricity to output terminals. The ESD safety precautions must be observed during installation and operation. To avoid the risk of electric shock do not attempt to open the unit, no serviceable parts inside. Use only power cord supplied with the unit or a cord approved for this type of appliance. The protective grounding conductor of the AC power cord must be connected to ground to provide protection against electric shock. AC Input AC Input Voltage: 240V, 50 Hz The power cord must be connected to an earthed mains outlet/power point. Environmental Requirements Operation Location: Indoor only, no direct sunlight and dust-free. Pollution degree 2, normally non-conductive. Temperature Rating: 0-40 C Page 4

Relative Humidity (non-condensing): <80% Altitude: <2000m above sea level Storage Location: Indoor Relative Humidity: <80% Temperature: 0-60 C FUSE PS-3005D and PS3005P: T3A/250V To avoid fire hazard replace the fuse only with the specified type and rating as per rating label. Disconnect the power cord before fuse replacement. Make sure the cause of fuse blowout is fixed before fuse replacement. OVERVIEW Main Features Model V Display A Display USB/RS Resolution PS-3005D 4 digit 4 digit NO 10mV/1mA PS-3005P 4 digit 4 digit YES 10mV/1mA Page 5

Performance Low noise, the cooling fan speed is adjusted proportionally to the heatsink temperature. Compact size, light weight. Operation Constant Voltage or Constant Current operation. Output On/Off control Voltage and Current digital display Memory function, up to 5 voltage/current settings can be stored. Coarse and Fine Voltage/Current adjustments from 0 to 30V and from 0 to 5A. Software controlled output setting through RS232 or USB port on P models Beep on front panel button pressing (except LOCK button) with On/Off option Key lock Protection Overcurrent (OCP) and output overvoltage protection (OVC). Interfaces USB compatible and RS 232 for remote control via PC, P models only. Page 6

Front Panel Overview Voltage Display V PS3000 POWER SUPPLY DIGITAL CONTROL Overvoltage Protection Active Overcurrent Protection Active Constant Current Mode Current Display A M4 M5 Constant Voltage Mode Output Off/On Indicator MEMORY RECALL/SAVE UNLOCK ADJUST Memory in use indicators M1 LOCK Key Lock Button BEEP Adjust Knob Overcurrent Protection ON/OFF M2 M3 OCP OVP Digit Selectors Overvoltage ON/OFF < > Buttons for Save&Recall M4 Voltage/Current Adjustment Selection Output Off/On POWER Power ON/OFF Button Output Terminals Earth/Ground Terminal The detailed description of function of particular controls, buttons and indicators is presented in the further chapters of this instruction. Page 7

Displays Voltage: Displays the set value of the output voltage when output is switched off. It displays the actual output voltage when the output is on A Current: Displays the set value of the output current when output is switched off. It displays the actual output current when the output is on. Status Indicators OVP indicates the state of the overvoltage protection. When this function is turned on the indicator is illuminated. When the output voltage is higher than the set value due to abnormal conditions the output is switched off and OVP indicator flickers. The OVP button is to be pressed to recover the supply to its previous state OCP indicates the state of the overcurrent protection. When this function is turned on the indicator is illuminated. C.C is the constant current mode indicator. When power supply is in this mode the C.C indicator is on. C.V is constant voltage mode indicator. When power supply is in this mode the C.V indicator is on. Page 8

OUT is output state indicator. If it is ON there is voltage/current present between output terminals. Indicate which memory location is being used Front Panel Buttons and Terminals MEMORY RECALL/SAVE M1 M2 M3 M4 Save or recall front panel settings. Four memory locations are available through buttons M1-M4. The fifth is accessible by rotating the ADJUST knob clockwise while the M4 location is being used. For details refer to page 16. UNLOCK LOCK Front panel key lock function. For details refer to page 14. BEEP OCP Dual function button. Single pressure toggles the Overcurrent protection function On/Off. If depressed and held for longer than 2 seconds it toggles the Beep function On/Off. Page 9

OVP Switches the Overvoltage protection On/Off Off/On Switches the output Off/On. ADJUST Knob for Voltage/Current adjustment. Rotating clockwise increases the value. < > Voltage/ Current Digit Selection buttons. Pressing the < key shifts selection the left, > key shifts selection to the right. Voltage Current adjustment selection button. Default is Voltage. POWER On/Off Power Switch. Power is ON when switch is pressed. Output Terminals, 4mm banana sockets for 4mm banana plugs. The red terminal is positive (+) terminal and the black one negative (-). None of them is internally connected to mains Earth/Ground. Ground/Earth Terminal, connected to mains supply earth. Page 10

Rear Panel Overview Cooling fan and fan vents Communication Ports WARNING DO NOT REMOVE COVERS; SERVICING TO QUALIFIED VOLTAGE RATING: AC 240V FUSE RATING: 2A/250V Rating Label IEC Power Socket USB socket for connecting to PC USB port. RS232 socket for connecting to PC RS232 port. Fused Appliance Inlet/Power Socket Page 11

Before the fuse replacement make sure power cord is disconnected from the power supply. Ensure the correct type of the fuse is used, refer to rating label and Fuse chapter on page 6. OPERATION Manual Operation D and P models. During manual operation the power supply is NOT connected to the PC. Connect AC power cord of a proper type between the IEC socket on the back panel and mains supply outlet rated as per voltage/fuse rating label. Power up. Press the POWER button in the front panel to switch the power supply ON. The displays initialize showing the settings from the M1 memory location, the M1 indicator is on. The OVP, OCP, C.C, C.V and OUT indicators are off. To switch the power supply off press the POWER button again. Note: By default the output is off after power up. Page 12

Output On/Off Press the On/Off button to turn the output ON. Now the voltage as set in the memory M1 is present between (+) and (-) terminals. If a load was connected to the supply the value of the output current is shown on the A display. If no load was connected the A display shows all zeros. Pressing the Off/On button again switches the output off. Note: The output will automatically switch off if any of the following conditions occur: 1. OVP function is activated and the measured output voltage exceeds the set voltage due to external reasons. 2. Any memory M1-M4 button is pressed or ADJUST knob rotated clockwise while M4 memory location is in use. Beep On/Off By default the beep function is enabled. To turn off the beep: Press the OCP (BEEP) button for at least 2 seconds until a short beep is heard. The function is now turned off. To activate this function press and hold the same button for at least 2 seconds until a long beep is heard. The state of this function is one of the parameters stored in the internal memory, common for all locations M1-M5. Note: Pressing and holding the OCP button to disable the beep function toggles the OCP function On/Off as well. Page 13

Front Panel/Key Lock Press and hold the LOCK button for at least 2 seconds. A successful locking is confirmed by a long beep. All the function buttons and the ADJUST knob are then disabled. Unlocking is done by pressing the LOCK button again for at least two seconds. The unlocking is confirmed by a short beep. Note: Locking is not switching the output off. Setting Output Parameters 1. Select the memory location for which the settings are to be defined following instructions in Save/Recall Setup section. 2. With output switched off press the Voltage/Current selection button to set the output voltage. One of the digits in the V display will flash. By default this is the second digit from the left. 3. Adjust the voltage to the required value by rotating the ADJUST knob. The precision of adjustment can be changed by selecting digits in the voltage readout with the < and > buttons. Rotating the knob clockwise increases the value while anticlockwise- decreases. In the constant voltage mode (CV) the set value is the desired output voltage. In the constant current mode (CC) this is the output voltage limit. With over-voltage protection (OVP) ON the output switches off if the voltage exceeds this value. 4. Press the Voltage/Current button again to adjust the current. Now Page 14

a digit in the A display will start flashing. Set the current using the same procedure as for voltage adjustment. In the constant voltage mode (CV) the set value is the current limit. In the constant current mode (CC) this is the output current. With over-current protection (OVP) on the output switches off if the current exceeds this value. 5. Press the memory button again or alternatively wait until the display stops flashing a digit. In case of M5 just wait for the display to stop flashing. Pressing the Off/On button will save the setting as well. Note 1: Adjustments of the voltage and current values is possible with the output on. In this case the output voltage or current will change on adjustment. However, pressing any of the M1-M4 buttons will store the final values but the output will be switched off. Note 2: If the current was set to 0 the output will not switch on upon pressing the Off/On button. Constant Voltage and Constant Current operation. When the output current does not exceed the set value the power supply works in the constant voltage mode (C.V) with the output voltage as set and the output current depending on the impedance of the load connected. The C.V indicator is ON. When the load is causing the output current to exceed the set value the power supply switches into constant current mode (C.C) with the output current as set and the output voltage depending on the impedance of the load connected. The C.C indicator is ON. Page 15

Note: If the OCP function is switched ON the supply does not change to C.C mode but is switching the output off instead. Save/recall setup The following settings can be stored in one of fife memories: Output voltage and current Beep function state, on or off (for M1-M5) The following settings are not saved. Their default state on power up is off. Output on/off Key Lock on/off OCP and OVP on/off Position of the digit to be adjusted first. 1. To select the memory to be used for save/recall press one of the M1-M4 buttons. The corresponding M1-M4 indicator will come on and the parameters stored in this location will be recalled. Their values can be then changed using the procedure outlined above in Setting Output Parameters. 2. To select memory M5 select the M4 first by pressing M4 button then rotate the ADJUST knob clockwise. The M5 indicator will come on. The parameters stored in this location will be recalled and their adjustment possible. Note: Recalling values from any memory location switches the output off. Page 16

Remote Control The model with suffix P can be controlled via PC through USB or RS232 interface. The USB and RS 232 ports are located on the back of the supply. For RS232 control the setting of the appropriate COM port is as follows: Baud rate : 9600 Parity bit: None Data bits: 8 Stop bits: 1 Data flow control: None 1. Connect the RS232 or USB ports on the power supply to PC using RS232 or USB cable. (RS232 cable not provided). 2. Switch the power supply on. It will automatically establish connection - if successful a beep will be audible. Use the preinstalled PC software to set the power supply parameters. Note: When the connection with PC is established the front panel is locked, button functions are not accessible and the power supply is controlled from PC only. 3. To exit from the Remote Control mode close the remote control application and disconnect the USB/RS 232 cable from the port on the power supply. The power supply will disconnect and a beep will confirm a successful disconnection. Then it switches itself into manual mode and unlocks the front panel. Page 17

Functionality check. Run this query command via the PC terminal application such as MTTTY (Multi-threaded TTY): *Idn This should return the identification information like: manufacturer and model name, serial number, version number in format: PS3005, SN: XXXXXXXX, V.XX Remote control PC application. For details on installation and operation of the PC software refer to the used guide included with the software (for P model only). Page 18

FAQ Q1: The panel buttons don t work after power on but the V and A displays are ON. A1: The front panel is locked. Press and hold the LOCK button for at least 2 seconds, until a short beep is heard. Q2: No output after pressing Off/On button with supply powered on and displays working. A2: Current is set to 0. Q3: Output voltage rises slowly after pressing the Off/On button A3: No load connected or the set current is too small. Q4: Output switches automatically off after pressing Off/On button with OCP function activated. A4: OCP value is set too low for particular load connected. Adjust the OCP current and then press Off/On button. Page 19

SPECIFICATION Note: The specifications below are valid under test temperature of 25 C±5 C and after power supply warm-up for at least 20 minutes. Model PS-3005D/P Voltage Range 0-30V Current Range 0-5A Load Regulation Voltage Current Line Regulation Voltage Current Setup Resolution Voltage Current 0.01%+2mV 0.1%+10mA 0.01%+3mV 0.1%+3mA 10mV 1mA Setup Accuracy(25 +-5 ) Voltage Current Ripple(20Hz-20MHz) T Voltage Current Voltage Current 0.5%+20mV 0.5%+10mA 2mV rms 3mA rms 100ppm+10mV 100ppm+5mA Page 20

Read Back Accuracy Voltage 10mV Current 1mA Read Back Temp. Coef Voltage 100ppm+10mV Current 100ppm+5mA Page 21

Wavecom Instruments Pty Ltd Adelaide 257 Grange Road FINDON SA 5023 Ph: (+61) 08 8243 3500 Fax: (+61) 08 8243 3501 Email: sales@wavecom.com.au Web: www.wavecom.com.au Melbourne 772A Station Street BOX HILL VIC 3128 Ph: (+61) 03 9897 4711 Fax: (+61) 03 9897 4766 Email: salesvic@wavecom.com.au Web: www.wavecom.com.au Page 22