Variable Density, Closed-Loop, Water-Cooled Data Center Solution

Similar documents
Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

ENCLOSURE HEAT DISSIPATION

Data center solutions for successful companies Cooling solutions

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center

Thermal management. Thermal management

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

Closed-Loop Water-Cooled Enclosure GL840ES-3048-CLWCE. High Performance 30kW Closed-Loop Water-Cooled Enclosure COOL THE SERVERS, NOT THE ROOM!

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

To Fill, or not to Fill Get the Most out of Data Center Cooling with Thermal Blanking Panels

Recapture Capacity for Existing. and Airflow Optimization

Reducing Energy Consumption with

Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer

Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc.

Efficiency of Data Center cooling

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Impact of Air Containment Systems

A Green Approach. Thermal

Rittal Cooling Solutions A. Tropp

Reclaim Wasted Cooling Capacity Now Updated with CFD Models to Support ASHRAE Case Study Data

MSYS 4480 AC Systems Winter 2015

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42

Application of TileFlow to Improve Cooling in a Data Center

Power and Cooling for Ultra-High Density Racks and Blade Servers

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

Great Lakes Product Solutions for Cisco Catalyst and Catalyst Switches: ESSAB14D Baffle for Cisco Catalyst 9513 Switch

Total Modular Data Centre Solutions

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

1.866.TRY.GLCC WeRackYourWorld.com

ECOBAY: Closed loop water cooled server cabinet for data centers

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Rethinking Datacenter Cooling

Liebert DCW CATALOGUE

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

Data Center Airflow Management Basics: Comparing Containment Systems

High Tech Getting Too Hot? High Density Environments Require A Different Cooling Approach

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

COOLING WHAT ARE THE OPTIONS AND THE PROS AND CONS FOR THE VARIOUS TYPES OF DATACENTRES SERVER AND COMMS ROOMS

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Virtualization and consolidation

Data Center Temperature Design Tutorial. Ian Seaton Chatsworth Products

Reducing Data Center Cooling Costs through Airflow Containment

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

Next Generation Cooling

Data Center Trends: How the Customer Drives Industry Advances and Design Development

Air Containment Design Choices and Considerations

Design and Installation Challenges: Aisle Containment Systems

REPORT. Energy Efficiency of the San Diego Supercomputer Center and Distributed Data Centers at UCSD. Prepared for:

Optimization in Data Centres. Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months

Switch to Perfection

A separate CRAC Unit plant zone was created between the external façade and the technical space.

FREEING HPC FROM THE DATACENTRE

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

Rittal White Paper 506: Cold Aisle Containment for Improved Data Center Cooling Efficiency By: Daniel Kennedy

Close Coupled Cooling for Datacentres

Cabinet Level Containment. IsoFlo Cabinet. Isolated Airfl ow Cabinet for Raised Floor Data Centers

DCIM Data Center Infrastructure Management Measurement is the first step

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Effectiveness and Implementation of Modular Containment in Existing Data Centers

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

84 kw, Tier 3, Direct Expansion, 937 ft 2

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

Reverse Flow Cabinet. ContraFlo Cabinet. Reverse Flow Cabinet for Raised Floor Data Centers

System Overview. Liquid Cooling for Data Centers. Negative Pressure Cooling Without Risk of Leaks

Improving Data Center Efficiency

Retro-Commissioning Report

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

APC APPLICATION NOTE #146

Cannon T4 Modular Data Center (MDC)

INNOVATE DESIGN APPLY.

Optimizing Cooling Performance Of a Data Center

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

INNOVATE DESIGN APPLY.

Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms

HIGH DENSITY RACK COOLING CHOICES

APC APPLICATION NOTE #114

Cost Model Energy Benefits DirectAire & SmartAire Overview & Explanation

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

A LAYMAN S EXPLANATION OF THE ROLE OF IT RACKS IN COOLING YOUR DATA CENTER

ENCLOSURE THERMAL TESTING HEAT REMOVAL IN THE REAL WORLD

Ten Cooling Solutions to Support High- Density Server Deployment

Facilities Design for High density Data Centers

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

IT Air Conditioning Units

Google s Green Data Centers: Network POP Case Study

DATA CENTER LIQUID COOLING

DCIM Data Center Infrastructure Management

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

Innovative Data Center Energy Efficiency Solutions

Data Center Optimized Controls

SmartRow Intelligent, Integrated Infrastructure in a Self-Contained Line-Up. Solutions For Business-Critical Continuity

APC InfraStruXure Solution Overview

Transcription:

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

Overview Great Lakes Case & Cabinet Co., Inc. has worked with Naissus Thermal Management Solutions, of Toronto, Ontario to develop one of the most efficient and effective closed-loop water-cooled enclosures in the industry, with the ability to easily handle a 30kW load under normal conditions. Together, Great Lakes and Naissus have translated that same technology into a variable density cooling system, which is deployed in pods of up to six enclosures, supported by a single 30kW cooling station. That 30kW can then be distributed, as needed, to individual enclosures in a single grouping, in densities ranging from 5 kw to 15kW. The Great Lakes/Naissus design allows each grouping or pod of enclosures to essentially act as its own data center without any reliance on CRAC units or the over-cooling of the data center space. Utilizing dedicated chilled water delivered via a high-efficiency pumping system as its cooling medium, the cooling station serves as a heat exchanger, taking in heated exhaust from the enclosures in the pod via a proprietary plenum system, passing that hot air over a unique coil mounted within the station. The conditioned water, at a consistent temperature and flow, converts that heated exhaust into conditioned air. That conditioned/cooled air is then delivered to each of the enclosures in the pod via a proprietary plinth platform to deliver that conditioned air within a plenum chamber inside each enclosure and directly in front of the mounted equipment. High efficiency fans are located throughout the system to help drive both conditioned air and heated exhaust. High speed vanaxial fans are located in the cooling station to collect and focus exhaust and to direct it across the heat exchanger in the most efficient manner possible, while maintaining static pressure Unlike in-row/close-cooled systems, this solution maximizes the efficiency of the conditioned air by delivering it to rack mounted equipment without the risk of bypass air flow or hot air recirculation. The system is truly closed loop in nature and requires no additional air conditioning within the data center space. The system is easily installed on a slab floor with water and power delivery from above and from outside the data center space. Variable Density, Closed-Loop Water-Cooled Data Center Solution August, 2012 Page 1

Tremendous Flexibility, in Support of Future Demand While initial pod deployment may require 5KW or less per enclosure, future colocation customers may have varying needs and anticipated growth requirements which necessitate medium or high density cooling. The cooling station can be deployed as needed to support two, three, four or up to six enclosures as desired. If there is a need for even higher density, the Great Lakes CLWC (closed loop water cooled) enclosure may be included in a pod to create a 30kW option. The Pod An Example: A Pod of Six Enclosures Supported by a 30Kw Cooling Station Variable Density, Closed-Loop Water-Cooled Data Center Solution August, 2012 Page 2

Variable Density, Closed-Loop Water-Cooled Data Center Solution August, 2012 Page 3

Conditioned Air Flow Delivery and Collection of Heated Exhaust Variable Density, Closed-Loop Water-Cooled Data Center Solution August, 2012 Page 4

An Example Performance of Cooling Unit (Six Cabinets + Cooling Unit) Imperial Units SI Units Heat Load 102500 BTU/h 30 kw Water Temperature 55 F 12.7 C Water Flow 18 gpm 1.13 l/s Cold Air Supply 75 F 24 C Hot Air Return 115 F 46 C ΔT - Air 40 F 22 C ΔT - Water 11.4 F 6.3 C Air Flow 2500 CFM 1.18 m 3 /s Fan Power 4100 BTU/h 1200 W PUE 1.2 1.6 2.0 Total IT Load: 210kW 210kW 210kW Total Facility Load: 252kW 336kW 420kW Electricity Cost (KW/h): $0.10 $0.10 $0.10 Annual Power Usage: 2,207,520kW 2,943,360kW 3,679,200kW Annual Power Cost: $220,752 $294,336 $367,920 Annual Power Savings: 735,840kW 1,471,680kW Annual Cost Savings: $73,584 (25%) $147,168 (40%) Variable Density, Closed-Loop Water-Cooled Data Center Solution August, 2012 Page 5

CFD Analysis Computational Fluid Dynamics (CFD) modeling uses computer calculations to simulate the interactions of liquids and gases with various surfaces in a defined space. To better understand the role the enclosure plays in the operation of the data center, Great Lakes and Naissus Thermal Management Solutions have developed the capability to perform CFD analysis with data center specific software. We are now able to help customers to better understand what is currently happening in their data center environment, to test or plan capacity increases or, to test a data center, room or pod design before ever starting a build. Using the performance data from the variable density pod, as calculated on page 5, a simulation effort was undertaken with the primary goal of ensuing adequate airflow through the system, which would result in proper internal air temperature and cooling of the installed equipment: This thermal CFD rendering is an iso view of the variable density pod and shows how conditioned air flows from the cooling station (rack cooling unit as a 30kW heat exchanger) into the12" H bottom plinth, through the enclosures and into the exhaust chimney ducting in the top plenum of the pod Variable Density, Closed-Loop Water-Cooled Data Center Solution August, 2012 Page 6

This front view rendering shows air flow through the bottom plinth and top plenum This rear view rendering shows the heated exhaust from the servers in each enclosure, moving up through the exhaust chimneys, being collected into the top plenum and moving into the cooling station to pass across the heat exchanger. Variable Density, Closed-Loop Water-Cooled Data Center Solution August, 2012 Page 7

These front, side and iso view renderings show air flow through the cooling station, bottom plinth and top plenum Variable Density, Closed-Loop Water-Cooled Data Center Solution August, 2012 Page 8

This drawing and rendering shows a data center layout for a project which utilizes 24 variable density pods to place 144 enclosures into service. Variable Density, Closed-Loop Water-Cooled Data Center Solution August, 2012 Page 9

Variable Density, Closed-Loop Water-Cooled Data Center Solution August, 2012 Page 10