VI Chip BCM Customer Evaluation Board User Guide

Similar documents
HD Series Brick Evaluation Board

PowerAmp Design EVAL117 EVALUATION KIT FOR PAD117A

Full-chip PRM -RS Customer Board User Guide

XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116

EFE300 / EFE400 EFE300M / EFE400M

Test Methods for DC/DC Power Modules

PowerAmp Design EVAL118. PowerAmp Design EVAL118 EVALUATION KIT FOR MODELS PAD115/ 118/ 119 EVALUATION KIT FOR MODELS PAD115/ PAD118/ PAD119.

PowerAmp Design. PowerAmp Design EVAL127 EVALUATION KIT FOR PAD127/157. Rev G

EFE300 / EFE400 EFE300M / EFE400M

UF-3701 Power Board Construction Guide

Product Manual. Surge Protected Metal 7- Port USB 2.0 Hub DIN RAIL Mount Kit NEC Chip

AC/DC Power Supply Series APPLICATION NOTE

[Note: Power adapter is not included in the kits. Users need to prepare a 9 12 V ( >300mA capacity ) DC power supply]

PFC Mini TM Power Factor Corrected AC-DC Switchers

Configuring Vicor IBC Converters with nipols

Accessories Mounti ng Supports

POL BMR465 Evaluation Board

SIM-9106/9303 High Current Switching Mode Power Supply with C.C., C.V., Remote Control & Sensing User Manual

ISOLATION RELAY RACK ISOLATION KIT 19 RACK MOUNT RELAY RACK ISOLATION KIT, SLOTTED UNEQUAL FLANGE RACK ISOLATION KIT 23 RACK MOUNT

HX4002 HX1001. White LED Backlighting Li-Ion Battery Backup Supplies Local 3V to 5V Conversion Smart Card Readers PCMCIA Local 5V Supplies

2 AA Cell to 3.3V USB On-The-Go Devices White LED Drivers Handheld Devices. The HM3200B is available in the 6-pin SOT23-6.

TEP 100WIR Series, 100 Watt

SDG1400 User s Guide

TEMPERATURE SENSOR/FAN CONTROL BOARD USER'S MANUAL

INSTRUCTION MANUAL RA 59 RACK ADAPTER. 1) This manual is valid for the following Model and associated serial numbers: MODEL SERIAL NO. REV. NO.

B.Y.O.C. MK2 Kit Instructions

INSTRUCTION MANUAL RA 19-4C RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF 300W, 600W, 1200W, 1500W SERIES POWER SUPPLIES

Ag Leader Technology. DirectCommand Installation Miller Nitro 5000 & 6000 ISO Kit

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS

Technical Manual SMART TRAC PS Card

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

USER MANUAL FOR HARDWARE REV

G SERIES ISOLATED, PROPORTIONAL DC TO HV DC CONVERTERS

EK27. Evaluation Kit APPLICABLE PARTS (SOLD SEPARATELY) INTRODUCTION PA50 PA52

EMEVB8900 EVALUATION BOARD USER GUIDE

GCI-5K INSTALLATION AND OPERATOR S MANUAL

POL BMR466 Evaluation Board

JUPITER-MM. DC/DC Power Supply PC/104 Module. User Manual V1.3

COMPACT DISC CHANGER SERVICE MANUAL CONTENTS

Software... pg3 File Maintenance Training

TEP 75WI Series, 75 Watt

High Power (15W + 15W) Stereo Amplifier

Description & Installation Guide

MAX16128/MAX16129 Evaluation Kits. Evaluate: MAX16128/MAX General Description. Features. Component List

DC-DC CONVERTERS SINGLE OUTPUT, 60 WATTS EXTREMELY WIDE 12:1 INPUT VOLTAGE RANGE: 9-75VDC, VDC RAILWAY APPLICATIONS

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Model User Manual Revision E 04/29/99. OEM Gaging System. Part Number R01

APPLICATION NOTES. Wire Gauge and Distance to Load

Model 2380 Rack-Mount Kit

TEP160-WIRCM SERIES 160 Watt High Density Brick DC-DC Converter Measures: 2.40 x 2.28 x 0.50

Tile Plow Installation Gold Digger

Simple but elegant look and ease of installation make it ideal for various industrial applications.

PedalSync. 9 Switches MV-62. Chip. Module. and

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

Model 2380 Rack-Mount Kit

User s Guide. RP7000S Series Single-Ended Active Probe. Nov RIGOL Technologies, Inc.

Butterfly Laser Diode Mount

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

Replace the edrive TINI Module and Battery

S E R V I C E N O T E

Operational Amplifiers: Temperature-Controlled Fan

DC Outdoor Power Supply/Chargers

VS-P Series. TDK-Lambda INSTRUCTION MANUAL

Model 2657A-LIM-3 LO Interconnect Module

Compact Inductive Proximity Sensor

VIPAC Array Family. of DC-DC Converters Up to 750 Watts. Description & Installation Guide. Product Description

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.

Tile Plow Installation O Connell

ENG-7680: SCADA Laboratory Experiments

MicroPAC AC-DC Power Supply

DEMO MANUAL DC1520A LT3690: 36V/4A µpower Synchronous Buck Regulator DESCRIPTION PERFORMANCE SUMMARY

2015 SIMMCONN LABS, LLC. All rights reserved. NewScope-T1 Operation Manual

OPERATING INSTRUCTION

Freescale Semiconductor Data Sheet: Technical Data

Power Supply and Fan Module Installation

Low-Capacitance, 2/3/4/6-Channel, ±15kV ESD Protection Arrays for High-Speed Data Interfaces

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY I INTRODUCTION

Specifications are at T A = 25 C

T100MD (Rev D-1) PLC Installation Guide

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

TECHNICAL NOTE. VS1000: Evaluation Kit EVBA_2.0. Contents. EVBA_2.0 is a plug and play Evaluation Kit for Colibrys VS1000 accelerometers line.

Procedure to Install an IO Expansion Cage Assembly in a Maxum II Modular Oven Analyzer

DEMO MANUAL DC2016A LTM V IN, 5.4A Buck-Boost μmodule Regulator. Description

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

CP5176 Assembly guide. Soldering. CP5176 Assembly guide Main PCB PCB split. Document revision 2.1 Last modification : 12/11/17

November 2000 Mixed-Signal Products SLOU086

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

GPIB-232CT-A IBCL EPROM Installation Guide

GX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available

Analog Door Phone Model LUADS

AOZ8900. Ultra-Low Capacitance TVS Diode Array PRELIMINARY. Features. General Description. Applications. Typical Application

Global Plasma Solutions. 10 Mall Terrace, Bldg C Savannah, GA (912) ph (877) fax

CPH a b c d - 70 XX X. Standoff Height 1:0.08

DirectCommand Installation 5 Channel Spreader Control Module Technology

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

DCR1 60V/50A DC Relay Installation Guide

Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

SNA KIT Assembly Guide

Transcription:

USER GUIDE UG:001 VI Chip BCM Customer Evaluation Board User Guide Contents Page Features 1 Introduction 1 Set Up 3 Recommended 5 Hardware Thermals 5 Ordering Info 5 Introduction Oscilloscope probe jack for output voltage and ripple measurements Simple to use Ring lug or solder connections Parallelable Introduction The Customer Evaluation Board offers a convenient means to evaluate the performance of Vicor s BCM bus converter and has been optimized for user convenience. Refer to the appropriate BCM data sheet for performance and operating limits. The data sheets are available for downloading at vicorpower.com. It is important to remember the fast response of most BCMs can readily show the limitations of the source, load, and associated wiring connected to the evaluation board. Care should be exercised to minimize stray source and load impedances in order to fully exercise the BCM. Please refer to Figure 1 for locations of the input and output connections as viewed from the component side. Wires may be soldered directly to the pads instead of ring lugs if desired to minimize circuit impedances. UG:001 vicorpower.com Applications Engineering: 800 927.9474 Page 1

Figure 1. Board demo layout and dimensional drawing, component side TP5 Ø 0.20 Typ 5.08 1.65 41.9 TP2 TP1 C1 BCM J1 OUT TP7 TP6 C L IN TP4 2.52 64,0 Figure 2. BCM Customer Evaluation Board schematic TP5 +In +Out TP7 TP2 TP1 BCM -Out +Out TP6 J1 IN C1 2.2 µf 450 V TP4 -In -Out OUT UG:001 vicorpower.com Applications Engineering: 800 927.9474 Page 2

Set Up The Customer Evaluation Board should be set up as follows: Note: Care should be taken to avoid reversing polarities if connecting to the opposite (solder) side of the board. + IN, IN Connect a high-quality, low-noise power supply to the and IN terminals of the Customer Evaluation Board. The interconnect leads should be heavy gauge and as short as possible. Additional capacitance may have to be added on the evaluation board to make up for impedances in the interconnect leads as well as deficiencies in the source. It is important to remember that noise from the source, as well as any input source voltage drops, will appear at the output of the BCM multiplied by its K factor. Test points 4 ( IN) and 5 () can be used to monitor the input and are located on the B adjacent to the input terminals. + OUT, OUT An electronic or passive load should be connected to and OUT terminals of the Customer Evaluation Board with short heavy-gauge leads. Most commercially available electronic loads do not have current slew rates capable of fully exercising the BCM. The Customer Evaluation Board can be connected directly to the application for which the BCM is intended. However, the interconnect impedances between the Customer Evaluation Board and the application can greatly affect the transient response. For applications where transient response is critical, the user should consider mounting the BCM directly to the target application B. Test points 6 ( OUT) and 7 () can be used to monitor the output and are located on the B adjacent to the output terminals. Output Voltage Measurement Jack (J1) This connector is provided to make accurate measurements of the output voltage of the BCM. Many types of scope probes may be directly connected to this point if the probe is equipped with a removable plastic sheath. To avoid creating ground loops when making measurements of the output or input voltage, these measurements should be made separately. Paralleling The paralleling and current sharing capability of the devices can be demonstrated by stacking multiple Customer Evaluation Boards and interconnecting the inputs and outputs with standoffs of sufficient current handling capability to create a 3-dimensional array. See Figure 3. When paralleling BCMs, the ports should be connected together to ensure the outputs turn on simultaneously. UG:001 vicorpower.com Applications Engineering: 800 927.9474 Page 3

Figure 3. Paralleling connections of two Boards -IN -OUT Input Current Measurement A current probe can be passed around the +in lead connected to the BCM. Input capacitors on the Customer Evaluation Board are downstream of this measurement point. - Do not connect, for factory use only. VC - Do not connect, for factory use only. Primary Control () The can be used to disable the BCM, monitor status, or provide a primary referenced bias supply. a. Connecting to the in will disable the BCM. b. Connecting a DVM or oscilloscope between (positive) and in (negative) will indicate the status of the BCM. Please note that the BCM does not have active current sinking capability. c. Connecting a load between (positive) and in (negative) will provide a primary referenced bias supply. Efficiency Measurement As the BCM can deliver and consume large currents, the effect of the B must be considered when making an efficiency measurement. Be certain to accurately measure the voltage directly at the BCM using the appropriate pair of contact points located at the corners of the BCM. UG:001 vicorpower.com Applications Engineering: 800 927.9474 Page 4

Recommended Hardware: Quantity Description Manufacturer P/N Vicor P/N 4 ring lug Panduit LCAS6-10-L 4 #10-32 screw 4 #10 flat washer 4 #10 lock washer 4 #10 hex nut All hardware is stainless steel except the ring lug. Kit # 26647 is included with the Customer Evaluation Board. Thermals } Kit # 26647 For most lab environments a fan blowing across the evaluation board is recommended. See Application Note AN:008 at vicorpower.com or contact Vicor Applications Engineering for assistance (800) 927-9474. Caution The BCM and Customer Evaluation Board can comfortably operate at surface temperatures which may pose a thermal hazard to the operator. Be careful not to touch any exposed surface. Certain BCMs may operate at potentially dangerous voltages, use care in such cases. The Customer Evaluation Board is not intended for use in end item equipment. Ordering Information The BCM evaluation boards can be ordered from the Vicor website: vicorpower.com. To order the demo boards, substitute BCM with BCD in BCM part number. See www.vicorpower.com/dc-dc-converters-board-mount/bus-converter-module for part number listing. The Power Behind Performance Rev 1.1 08/2014 vicorpower.com Applications Engineering: 800 927.9474 Page 5