Sun Netra TM X4200 M2 Server Product Notes

Similar documents
Sun Control Station. Performance Module. Sun Microsystems, Inc. Part No September 2003, Revision A

Sun Management Center 3.6 Version 7 Add-On Software Release Notes

Solaris 9 9/04 Installation Roadmap

Sun Management Center 4.0 Version 4 Add-On Software Release Notes

Sun Management Center 4.0 Version 3 Add-On Software Release Notes

Sun Management Center 4.0 Version 2 Add-On Software Release Notes

Cable Management Guide

Brocade 5100 Switch Hardware Release Notes

Sun StorEdge Network 2 Gb Brocade SilkWorm 3200 and 3800 Switches Release Notes

SunVTS Quick Reference Card

Sun Fire V100 Server Product Notes

Sun Fire V60x and V65x Servers ReadMe

Sun Management Center 3.5 Supplement for VSP High-End Entry Servers (Workgroup Servers)

Sun StorEdge 3310 SCSI Array Best Practices Manual

Memory Hole in Large Memory X86 Based Systems

Sun Ultra TM. 5 and Ultra 10 Product Notes. Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA U.S.A.

StorageTek Host Software Component (HSC) MVS Software

Solaris 8 6/00 Sun Hardware Roadmap

Sun Remote System Control (RSC) Release Notes

Sun StorageTek Backup Manager Release Notes

System Management Services (SMS) 1.6 Software Release Notes

man pages section 6: Demos

Sun Java System Connector for Microsoft Outlook Q4 Installation Guide

Sun Fire V60x and V65x BIOS and Firmware Update ReadMe

Sun Control Station. Software Installation. Sun Microsystems, Inc. Part No January 2004, Revision A

Rackmount Placement Matrix

Sun StorEdge T3 Disk Tray Cabinet Installation Guide

Sun Fire V125 Server Getting Started Guide

Solaris 8 User Supplement. Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA U.S.A.

Sun Update Manager 1.0 Administration Guide

Sun Blade 6048 Modular System Overview

Sun Fire V20z Server Installation Guide

Sun Fire V210 and V240 Servers Getting Started Guide

Sun Remote System Control (RSC) 2.2 Release Notes

Sun Blade 1000 and Sun Blade 2000 Product Notes

Sun Fire V490 Server Product Notes

Java Desktop System Release 2 Installation Guide

Sun Cluster 2.2 7/00 Data Services Update: Lotus Domino 4.6.3

Cluster Platform 15K/9960 System

Sun Multipath Failover Driver 1.0 for AIX User s Guide

Sun StorEdge Enterprise 2 Gb FC Single and Dual Port Host Bus Adapter Release Notes

UltraSPARC - IIs CPU Module Installation Guide

Solaris 8 User Supplement. Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA U.S.A.

Ultra Enterprise 6000/5000/4000 Systems Power Cord Installation

Sun Patch Manager 2.0 Administration Guide for the Solaris 8 Operating System

Traditional Chinese Solaris Release Overview

Font Administrator User s Guide

Sun StorageTek Common Array Manager Software Installation Guide

Sun Blade 1500 Product Notes

Java Desktop System Release 3 Troubleshooting Guide

Scenario Planning - Part 1

Font Administrator User s Guide. Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA U.S.A.

The Solaris Security Toolkit - Quick Start

Sun Management Center 3.6 Supplement for the Sun Fire, Sun Blade, and Netra Systems

Sun Storage J4200/J4400 Array Hardware Installation Guide

Solaris 8 Desktop User Supplement. Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA U.S.A.

Sun Cooling Door 5200 Installation and User s Guide

Integrated Lights Out Manager (ILOM) Supplement for Sun Blade X6220 Server Module

Sun Fire V480 Server Product Notes

Sun Enterprise System 336-Mhz Processor Upgrade Instructions

Sun StorageTek Backup Manager Administration Guide

SunPCi Release Notes

Provisioning in Replicated, Mission-Critical Environments

System Controller CPU Board, Netra CompactPCI, Installation Guide. Sun Fire E25K/E20K Systems Sun Fire 15K/12K Systems

Sun StorEdgeT 3310 SCSI Array Release Notes

Sun StorEdge Network 2 Gb Brocade SilkWorm 3200, 3800, and Core Fabric Switches Guide to Documentation, 3.x / Firmware

Solaris PC NetLink 1.2 Installation Guide

Sun Java System Application Server Platform Edition Q2 Update 2 Release Notes

Crypto Key Management Station

Sun Fire X4600 Server Windows Operating System Installation Guide

Sun Fire 6800 System and Sun Fire Cabinet Rackmount Placement Matrix

SunVTS Quick Reference Card

GNOME 2.0 Desktop for the Solaris Operating Environment Installation Guide

Sun Rack Cabinet Extension Installation Guide

Automating LDAP Client Installations

Sun StorEdge RAID Manager 6.2 Installation and Support Guide

Sun Storage J4200/J4400 Array System Overview

Sun Fire E6900/E4900 Systems Service Manual

Sun Fire E6900/E4900 Systems Site Planning Guide

Simplified Chinese Solaris Release Overview

Sun StorEdge Traffic Manager 4.4 Software Installation Guide

Netra 210 Server Service Manual

Sun Java System Directory Server Release Notes for HP-UX

Sun Fire TM E2900 Systems Getting Started

Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Release Notes

Sun Management Center 3.5 Service Availability Manager User s Guide

SunVTS 6.3 Patch Set 3 Documentation Supplement for x86 Platforms

Sun Blade 2500 Workstation Product Notes

GNOME 2.0 Desktop for the Solaris Operating Environment User Guide

Sun StorEdge 5310 NAS Appliance Software Installation, Configuration, and User Guide

Security and Trust Services APIs for Java 2 Platform, Micro Edition

Sun Fire E6900/E4900 Systems Overview

Sun Fire System Controller Board, Version 2 (Enhanced Memory) Installation Guide

20-40 Gbyte 8mm Tape Drive Installation and User s Guide

WDR Installation Guide

Solaris 8 Desktop User Supplement

External I/O Expansion Unit Product Notes

Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Release Notes

Netra 1290 Server Product Notes

Tales from the Trenches: The Case of the RAM Starved Cluster

Transcription:

Sun Netra TM X4200 M2 Server Product Notes Sun Microsystems, Inc. www.sun.com Part No. 820-0067-13 May 2009, Revision A Submit comments about this document by clicking the Feedback[+] link at: http://docs.sun.com

Copyright 2009 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved. Sun Microsystems, Inc. has intellectual property rights relating to technology that is described in this document. In particular, and without limitation, these intellectual property rights may include one or more of the U.S. patents listed at http://www.sun.com/patents and one or more additional patents or pending patent applications in the U.S. and in other countries. This document and the product to which it pertains are distributed under licenses restricting their use, copying, distribution, and decompilation. No part of the product or of this document may be reproduced in any form by any means without prior written authorization of Sun and its licensors, if any. Third-party software, including font technology, is copyrighted and licensed from Sun suppliers. Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in the U.S. and in other countries, exclusively licensed through X/Open Company, Ltd. Sun, Sun Microsystems, the Sun logo, Java, docs.sun.com, Sun Netra, SunSolve Online, and Solaris are trademarks or registered trademarks of Sun Microsystems, Inc., or its subsidiaries, in the U.S. and in other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the U.S. and in other countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc. The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sun holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements. U.S. Government Rights Commercial use. Government users are subject to the Sun Microsystems, Inc. standard license agreement and applicable provisions of the FAR and its supplements. DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. Copyright 2009 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, Californie 95054, États-Unis. Tous droits réservés. Sun Microsystems, Inc. possède les droits de propriété intellectuels relatifs à la technologie décrite dans ce document. En particulier, et sans limitation, ces droits de propriété intellectuels peuvent inclure un ou plusieurs des brevets américains listés sur le site http://www.sun.com/patents, un ou les plusieurs brevets supplémentaires ainsi que les demandes de brevet en attente aux les États-Unis et dans d autres pays. Ce document et le produit auquel il se rapporte sont protégés par un copyright et distribués sous licences, celles-ci en restreignent l utilisation, la copie, la distribution, et la décompilation. Aucune partie de ce produit ou document ne peut être reproduite sous aucune forme, par quelque moyen que ce soit, sans l autorisation préalable et écrite de Sun et de ses bailleurs de licence, s il y en a. Tout logiciel tiers, sa technologie relative aux polices de caractères, comprise, est protégé par un copyright et licencié par des fournisseurs de Sun. Des parties de ce produit peuvent dériver des systèmes Berkeley BSD licenciés par l Université de Californie. UNIX est une marque déposée aux États-Unis et dans d autres pays, licenciée exclusivement par X/Open Company, Ltd. Sun, Sun Microsystems, le logo Sun, Java, docs.sun.com, Sun Netra, SunSolve Online, et Solaris sont des marques de fabrique ou des marques déposées de Sun Microsystems, Inc., ou ses filiales, aux États-Unis et dans d autres pays. Toutes les marques SPARC sont utilisées sous licence et sont des marques de fabrique ou des marques déposées de SPARC International, Inc. aux États-Unis et dans d autres pays. Les produits portant les marques SPARC sont basés sur une architecture développée par Sun Microsystems, Inc. L interface utilisateur graphique OPEN LOOK et Sun a été développée par Sun Microsystems, Inc. pour ses utilisateurs et licenciés. Sun reconnaît les efforts de pionniers de Xerox dans la recherche et le développement du concept des interfaces utilisateur visuelles ou graphiques pour l industrie informatique. Sun détient une license non exclusive de Xerox sur l interface utilisateur graphique Xerox, cette licence couvrant également les licenciés de Sun implémentant les interfaces utilisateur graphiques OPEN LOOK et se conforment en outre aux licences écrites de Sun. LA DOCUMENTATION EST FOURNIE "EN L ÉTAT" ET TOUTES AUTRES CONDITIONS, DÉCLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA LIMITE DE LA LOI APPLICABLE, Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE À LA QUALITÉ MARCHANDE, À L APTITUDE À UNE UTILISATION PARTICULIÈRE OU À L ABSENCE DE CONTREFAÇON. Please Recycle

Contents Important Information About the Sun Netra X4200 M2 Server 1 Updated Product Note Information 1 How to Obtain Updates From Sun 1 Dual-Core and Quad-Core CPU Firmware and BIOS Compatibility 2 AC Power Surge Protection 2 Quad-Core CPUs for Sun Netra X4200 M2 Server 2 DIMM Requirements for Quad-Core Sun Netra X4200 M2 Servers 3 Identifying 4-Gbyte DIMMs Not Compatible With Quad-Core Upgrades 3 Upgrading a Dual-Core Sun Netra X4200 M2 Server to a Quad-Core 4 To Upgrade Dual-Core Server to a Quad-Core Server 4 Hardware Issues 5 Possible Rear Locate Button Damage When Replacing Motherboard 5 Memory Issues 5 Software Issues 6 BIOS Issues 6 Solaris OS Issues 6 Documentation Issues 7 Option Card and Rackmount Kit Installation Instructions 8 iii

iv Sun Netra X4200 M2 Server Product Notes May 2009

Important Information About the Sun Netra X4200 M2 Server This document contains the late-breaking news and information about new features, known limitations, and documentation updates for the Sun Netra X4200 M2 server. Updated Product Note Information Updated product notes for the Sun Netra X4200 M2 server are posted on the web, as needed. For the most recent version of the product notes, go to the Sun Netra X4200 M2 server documentation page at: (http://docs.sun.com/app/docs/prod/nt4200m2.srvr#hic) How to Obtain Updates From Sun You can obtain updates and patches from your Sun authorized sales representative or service provider, or by downloading them from the SunSolve Online SM web site: (http://sunsolve.sun.com/) For patch instructions, see the Readme file that accompanies each patch. For downloads of released software and firmware, visit the Sun Download Center at: (http://www.sun.com/downloads) 1

Dual-Core and Quad-Core CPU Firmware and BIOS Compatibility TABLE 1 lists the firmware bundles and BIOS, and the compatible CPU configurations. TABLE 1 Dual-Core and Quad-Core CPU Firmware Compatibility Firmware Bundle BIOS CPU Configuration V1.0 -V1.4.1 0ABLG008-0ABLG016 Dual-core only V1.5 0ABOR005 Quad-core only (Note: V1.5 superseded by V1.6) V1.6 0ABRM001 Dual-core and quad-core AC Power Surge Protection The Sun Netra X4200 M2 server does not require an additional surge protector for the AC power configurations if the facility has a surge protector that limits voltage surges to less than 1500 volts. You can, however, install a surge protector if your site requires an additional protector. Quad-Core CPUs for Sun Netra X4200 M2 Server Quad-core CPU versions of the Sun Netra X4200 M2 server are available in addition to the dual-core CPU versions. For information about the quad-core Sun Netra X4200 M2 servers, go to the Sun Netra X4200 M2 server product information web page at: (http://www.sun.com/servers/netra/x4200) 2 Sun Netra X4200 M2 Server Product Notes May 2009

DIMM Requirements for Quad-Core Sun Netra X4200 M2 Servers The 4-Gbyte DIMMs for dual-core and quad-core processors are not fully interchangeable. The existing Sun part number for 4-Gbyte DIMMs (X4227A-Z/540-7118) provides DIMMs from multiple sources that have been thoroughly tested in dual-core systems. Not all of these DIMMs have passed tests for use in quad-core systems. A new Sun part number (X4233A/540-7795) has been created for DIMMs that have passed these tests. Only DIMMs with this part number should be used on quad-core systems. If your system uses dual-core processors, you can use 4-Gbyte DIMMs supplied under the old part number (X4227A-Z/540-7118) or the newer part number (X4233A/540-7795) for quad-core systems. If your system uses quad-core processors, you can only use 4-Gbyte DIMMs supplied under the new part number (X4233A/540-7795). If you upgrade a dual-core system to use quad-core processors, you must remove any 4-Gbyte DIMMs provided under the old part number (X4227A-Z/540-7118) and replace them with 4-Gbyte DIMMs provided under the new part number (X4233A/540-7795). Identifying 4-Gbyte DIMMs Not Compatible With Quad-Core Upgrades Some 4-Gbyte DIMMs supplied with dual-core systems can have single-bit or multiple-bit errors after systems are upgraded to quad-core. Symptoms include sudden crashes and failure to boot. Not all existing 4-Gbyte DIMMs are affected. Affected DIMMs can be identified by Micron logo on the vendor s label and the part number and date code (see FIGURE 1). The vendor s part number is the first number. On affected DIMMs the part number is MT36HTF51272PY-667E. The manufacturing date code is the second number. On affected DIMMs the date code is a value lower than 200832, indicating that the DIMM was manufactured before the 32nd week of 2008. If the label matches the preceding description, it is not compatible with a quad-core processor. To obtain a replacement, contact Sun Service, and refer to FAB 244406. Important Information About the Sun Netra X4200 M2 Server 3

FIGURE 1 Micron DIMM Label Upgrading a Dual-Core Sun Netra X4200 M2 Server to a Quad-Core Use the following procedure to upgrade a dual-core Sun Netra X4200 M2 server to a quad-core server. To Upgrade Dual-Core Server to a Quad-Core Server 1. Prepare the server for the upgrade. Refer to the Starting the Maintenance Procedures in the Sun Netra X4200 M2 Server Service Manual (820-0063). 2. Remove the PCI tray. Refer to the Maintaining the PCI Tray section in the Sun Netra X4200 M2 Server Service Manual (820-0063). 3. Remove the DIMM/CPU duct. Refer to the Replacing the DIMM/CPU Duct section in the Sun Netra X4200 M2 Server Service Manual (820-0063). 4. (Optional) Replace the DIMMs. See DIMM Requirements for Quad-Core Sun Netra X4200 M2 Servers on page 3. Refer to the Replacing Memory Modules (DIMMs) section in the Sun Netra X4200 M2 Server Service Manual (820-0063). 4 Sun Netra X4200 M2 Server Product Notes May 2009

5. Replace the CPUs and heatsinks. Refer to the Replacing a CPU and Heatsink section in the Sun Netra X4200 M2 Server Service Manual (820-0063). 6. Install the DIMM/CPU duct. Refer to the Replacing the DIMM/CPU Duct section in the Sun Netra X4200 M2 Server Service Manual (820-0063). 7. Prepare the server for power on but do not power on the server. Refer to the Finishing the Maintenance Procedures in the Sun Netra X4200 M2 Server Service Manual (820-0063). 8. Download and update the firmware and BIOS. See Dual-Core and Quad-Core CPU Firmware and BIOS Compatibility on page 2 and How to Obtain Updates From Sun on page 1. Refer to the Sun Integrated Lights Out Manager 2.0 User s Guide (820-1188) for firmware and BIOS updating instructions. 9. Power on the server and reboot (if not set to auto reboot). Hardware Issues The following issues relate to Sun Netra X4200 M2 hardware. Possible Rear Locate Button Damage When Replacing Motherboard When replacing the motherboard, extra care is needed to prevent damage to the rear Locator button/led. Carefully align the Locate button with the access hole on the rear panel and ensure that the Locate button protrudes through the access hole before securing the motherboard in the chassis. Memory Issues Mixing single-rank and dual-rank 2-Gbyte DIMMs on a single CPU causes a small increase in memory access times Important Information About the Sun Netra X4200 M2 Server 5

Description: Depending on your application, this issue might or might not cause a small decrease in system performance. This issue does not cause memory or other errors. This problem does not occur if the single-rank and dual-rank 2-Gbyte DIMMs are mixed on different CPUs in the same system. Workaround: To minimize this problem, avoid mixing single-rank and dual-rank 2-Gbyte DIMMs on a single CPU. In some cases, you can identify a DIMM pair as single-rank or dual-rank by referring to the product description. In any case, you can identify the DIMM type by counting the DRAMs. A single-rank DIMM has 18 DRAMs, while a double-rank DIMM has 36 DRAMs. Software Issues The following issues relate to Sun Netra X4200 M2 software. BIOS Issues Updated P3 pci-sw/pci internal PCI bus numbering should be independent of BIOS enumeration order (for non-x8400 systems) (6472670) Description: After moving a PCI option card or adding or removing a device from one slot to another, the /etc/path-to-inst entries get out of sync with the actual device tree in the Solaris 10 Operating System (OS). The PCI device does not work even after a reconfigure boot. In some cases, the system fails to boot because it cannot find the boot device. Workaround: Install the desired PCI devices in the required slots, then do a fresh installation of Solaris OS. Solaris OS Issues Unexpected SIGTRAP signal causes dbx debugger to hang (6546562) Description: When the dbx debugger is being used on the Solaris 10 OS on x86 platforms to debug a program that raises or delivers signals that have signal handlers, dbx might receive an unexpected SIGTRAP signal from the kernel that causes dbx to hang. This situation can occur when dbx is single stepping, running to a breakpoint, collecting runtime checking (RTC) data, or performing any other activity that depends on signal trapping. 6 Sun Netra X4200 M2 Server Product Notes May 2009

In some cases, dbx displays a warning of an unexpected SIGTRAP signal when it hangs: dbx: internal warning: unexpected SIGTRAP! In other cases, dbx indicates receipt of a SEGV signal, as in the following example: signal SEGV (no mapping at the fault address) in main at line 29 in file "test.c" If you use a cont -sig SEGV command to continue execution with the SEGV signal, dbx will display the SIGTRAP warning. Workaround: Install kernel patch 137112-07. RTC: x86: signal SIGSEGV if debugger calls grantpt (6550564) Description: RTC instruments memory access instructions for access checking. These instructions are handled by a sigsegv handler at runtime. Because RTC requires its own sigsegv handler and signal alternate stack, any attempts to install a sigsegv handler or signal alternate stack (sigaltstack) results in EINVAL, or the installation is ignored. sigsegv handler calls cannot be nested. Otherwise, the nesting results in a terminating signal 11 SIGSEGV error. Workaround: If a terminating signal 11 SIGSEGV error occurs, use rtc skippatch to skip the instrumentation of the affected function. Otherwise, install patch 124873-06 to fix most of the segvs errors. RAID volume got corrupted label and bad geometry after system reboot (6527339) Description: The raidctl(1m) utility does not update the geometry data in the volume table after creating a RAID volume. The LSI RAID device requires space on the disk to store metadata and adjusts the block count on the disk, but does not update the disk volume table. Workaround: Follow the procedure in the hardware RAID section of the Sun Fire T2000 Server Administration Guide (819-2549). The procedure describes how to relabel the disk with the new volume geometry. Documentation Issues The following issues relate to Sun Netra X4200 M2 server documentation. Important Information About the Sun Netra X4200 M2 Server 7

Option Card and Rackmount Kit Installation Instructions The Sun Netra X4200 M2 Server Setup Guide (820-0062-12) contains the installation instructions for option cards and the rackmount kits. 8 Sun Netra X4200 M2 Server Product Notes May 2009