IMPROVING POWER SYSTEM RELIABILITY USING MULTIFUNCTION PROTECTIVE RELAYS

Similar documents
Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating

Protection, Monitoring, and Control System for Distribution Substations ALARM HISTORY SYSTEM COMM. On-Line Documentation TRANSFORMER 12 MW

Synchrophasor Fact Sheet

International Journal of Engineering Trends and Technology (IJETT) Volume 26 Number 2- August 2015

Protection, Automation, and Control System. Combine subcycle line protection with complete substation bay control

Protection, Automation, and Bay Control System. Advanced feeder protection and complete substation bay control in one economical system

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

Utility Implements Communications- Assisted Special Protection and Control Schemes for Distribution Substations

Advanced Protection and Control for a Power System Serving Industrial Customers

Approval...6. Current Revision...7. Introduction... 8 About PJM Manuals... 8 About This Manual... 8 Using This Manual...9

High-Reliability Fault-Clearing System solution. Application Guide. Outdoor Distribution (15.5 kv through 38 kv) S&C ELECTRIC COMPANY

System Protection and Control Subcommittee

Real Time Monitoring of

PRC System Protection Coordination Supplementary Reference

A low-cost, economical solution for distribution feeder protection

ELG4125: System Protection

Standard Development Timeline

SEL University. Power Through Knowledge. Dr. Héctor J. Altuve Ferrer Dean of SEL University

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

Advanced distribution feeder solution with integrated protection, monitoring, and control

Common Questions and Answers Addressing the Aurora Vulnerability

Lightweight and flexible recloser control for single-phase applications

Flexible High-Speed Load Shedding Using a Crosspoint Switch

HIGH LEVEL REQUIREMENTS OF FAST SIMULATION AND MODELLING SUITE OF TOOLS FOR FUTURE SELF-HEALING DISTRIBUTION POWER SYSTEM

p. 1 p. 9 p. 26 p. 56 p. 62 p. 68

Substation Automation Products. Line differential protection RED670 Relion 670 series

Evolution of Control for the Power Grid

Lessons Learned Implementing an IEC based Microgrid Power- Management System. K.A. GRAY, J.J. MRAZ* POWER Engineers, Inc.

Blackstart Hardware-in-the-loop Relay Testing Platform

Small Generator Interconnection System Impact Study Report. Completed For Q0047

Multifunction Relays and Protection Logic Processors in Distribution Substation Applications

PUBLIC SERVICE OF NEW HAMPSHIRE. Technical Requirements for Non Utility Generation Interconnecting to the PSNH Distribution System

USE CASE 14 CONTROLLED ISLANDING

High-speed transformer differential protection for up to five terminals

Built for speed, security, and simplicity

Automated Analysis of Digital Relay Data Based on Expert System

Supplemental Information

Power System Protection Training

Wide Area Monitoring and Control

Protective Relaying Principles And Applications Solution Manual File Type

2008 Many Changes in IEEE C37.2. IEEE Standard Electrical Power System Device Function Numbers, Acronyms and Contact Designations

Using the Bitronics 70 Series to Improve Local Monitoring and Control

To: Honorable Public Utilities Board Submitted by: From: Diosdado Hernandez, P. E. Approved by:

Reliability Standard Audit Worksheet 1

PRC Coordination of Protection Systems for Performance During Faults

1. Project Description

2 ms arc-flash protection and feeder relay in one platform

Protective Relay Application Guide Alstom

Bus Protection Application Challenges

We will discuss two types of loss-of-potential (LOP) logic during this presentation:

Standard Development Timeline

OC IEEE IAS/PES Meeting February 21, 2013

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

Protective Relaying Principles And Applications Solution Manual

Numerical Protective and Management Relays

Amsterdam 27 September 2017 David MacDonald

Protective Relaying Principles And Applications Solutions Manual

Identify and understand the operation of common bus. After this presentation you will be able to: Identify common bus arrangements

PG&E 500 kv Protection Standard Design and Development

Power System Resilience & Reliability. Robert W. Cummings Senior Director of Engineering and Reliability Initiatives i-pcgrid March 28, 2017

Innovative Distribution Feeder Protection and Control Schemes Using New Capabilities of Microprocessor Relays

SOUTHERN REGIONAL POWER COMMITTEE BENGALURU

Implementing a Dual Triple Modular Redundant Country-Wide Special Protection System

The SEL-700G Generator Protection Relay is the newest member of the SEL-700 series platform. It combines the protection features of the proven

Dynamic State Estimation Based Protection: Laboratory Validation

GE Multilin 350 Feeder Protection Relay Specifications

Operator Controls and Reclosing Eliminate expensive control switches and wiring. Selectively reclose with synchronism and voltage checks.

The various functions of an energy control center can be enumerated as under: 1. Load forecasting 6. Automatic generation control

NERC Event Analysis Update Webinar. Hassan Hamdar Chair, Event Analysis Subcommittee October 20, 2016

Standard EOP Disturbance Reporting

DNP Points List and Implementation

WESTERN PROTECTIVE RELAY CONFERENCE TESTING AND OPERATIONAL EXPERIENCES WITH HIGH SPEED DISTANCE RELAY IN BPA 500 KV SERIES COMPENSATED NETWORK

SEL Real-Time Automation Controller (RTAC)

Protection relays.

An Artificial Intelligence Based Approach for Bus Bar Differential Protection Faults Analysis in Distribution Systems

IMP/ 001 / 014 Policy for the Protection of Distribution Networks

UR Universal Relay Series

SYMAP R Plug in Variants FI, MI, 87M, TI Technical data

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector

SIGUARD System for Phasor Data Processing

Advanced Protection and Control Technologies for T&D Grid Modernization

POWER SYSTEM SECURITY CONCEPTS

Power Systems Communications Implementation of IEC61850 in a Substation Environment

MiCOM P122C Time-Overcurrent Protection

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

Configuration and Interoperability Guide for IEC for the SEL-751 Feeder Protection Relay. July 10, 2015

i-pcgrid Workshop 2014 PG&E Order No. 754 Analysis: Protection

ABB Inc. Substation Automation and Protection Division Coral Springs, FL Allentown, PA. Multi-Zoned Distance

British Columbia Utilities Commission Reliability Standards with Effective Dates adopted in British Columbia

RTDMS CAISO TRAINING SESSION

Awareness of the Situation

Achieving Smarter Grid Operation With On-Line DSA Technology

Collector System Design Considerations for Wind Farms. Sean Carr Ernst Camm S&C Electric Co.

Products Portfolio. Pole mounted Vacuum Recloser

UR Universal Relay Series

Circuit Breaker Asset Management using Intelligent Electronic Device (IED) Based Health Monitoring

Implementing the protection and control of future DC Grids

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Transcription:

IMPROVING POWER SYSTEM RELIABILITY USING MULTIFUNCTION PROTECTIVE RELAYS Armando Guzmán Schweitzer Engineering Laboratories, Inc. Pullman, WA 99163 A reliable power system maintains frequency and voltage excursions within acceptable limits under normal and abnormal operating conditions, without exceeding the thermal limits of the power system components (lines, transformers, generators, etc.). Typical frequency limits are f NOM ± 0.1 Hz; typical voltage limits are V NOM ± 5 %. Fink and Carlsen [1] identified five system operating states (Normal, Alert, Emergency, Extreme and Restoration), as illustrated in Figure 1. The power system operates in normal state when system frequency and voltages are close to their nominal values and there is sufficient generation and transmission reserve. The system enters an alert state when generation and transmission reserve margins are reduced or eliminated, or there is a problem with one or several of the system components (one or several lines are overloaded). In the alert state, automated and manual controls of the system operate to restore the system to the normal state. Adequate power system monitoring and metering are necessary to promptly detect power system problems and accelerate system recovery. When the voltage or thermal limits are exceeded or a fault develops, the system enters an emergency state. In the case of a fault, the fault detection, clearance, and system restoration should cause minimum system disturbance. High-speed protective relays and breakers are necessary; speed and proper execution of corrective actions are critical to prevent the system from entering the extreme state. For example, high-speed transmission line protection with single-pole tripping with adaptive reclosing capabilities [2] minimizes system disturbance. When entering the emergency state without a fault in the system, automated control (fast valving, static var compensation, etc.) is desirable to reestablish normal or alert operating state to avoid entering the extreme state. If the system cannot maintain the generation-load balance, the system enters the extreme state. In the extreme state, load shedding, generation shedding or system islanding occurs to balance generation and load. Underfrequency load shedding schemes operate to restore load-generation balance across the system; undervoltage load shedding schemes operate to avoid system voltage collapse. Remedial action schemes [3] that monitor power flows, system configuration, voltage levels, etc. actuate to separate the system in islands or shed generation to maintain the loadgeneration balance to avoid total system collapse. After load and/or generation shedding, the system enters a system recovery state. In this state, manual or automated reinsertion of generation and load occurs. Figure 2 identifies tasks that multifunction protective relays can execute to improve system reliability in each of the system operating states. SEL White Paper 1

Normal Gen = Load V and V I OK I OK Gen Load V and I OK Restoration Alert Gen = Load V and I OK Gen Load <V or >V or >I Extreme Emergency Gen = Load <V or >V or >I Figure 1 Fink and Carlsen Diagram Showing All Possible Power System Operating States and Normal/Emergency State Transitions Added NORMAL AND ALERT STATES In the normal and alert states, multifunction relays provide system monitoring. These devices obtain samples of the power system voltages and currents synchronized within 1 µs. We can use this capability to measure the state of the system in true real time instead of trying to estimate the system state using SCADA and traditional state estimation systems [4]. Additional monitoring capabilities include the following: Fast open line monitors quickly detect system configuration changes. Comprehensive line, transformer and motor thermal models [5] [6] warn of dangerous system component operating conditions. Real time channel communications monitoring improves communication system availability and warns when communications errors occur. Load encroachment region definition avoids line protective relay misoperation during heavy load conditions. System frequency tracking allows relays to adapt to changes in system operating conditions. Out-of-step detection avoids unnecessary tripping of transmission lines. Breaker monitoring includes the following: Trip coil supervision alarm Breaker contact wear Electrical and mechanical operating time Pole discrepancy Interrupted current Motor running time Breaker inactivity time DC supply monitoring includes the following: DC ground detection Voltage level alarm Open current transformer detection Potential transformer monitor 2 SEL White Paper

EMERGENCY STATE In the emergency state, proper execution of corrective actions is key to restoring the system to normal or alert states. Actions that cause minimum system disturbance are required. Multifunction relays are capable of detecting system faults in less than one power system cycle [7] and automatically restoring the system once the fault has been cleared. Because single-lineto-ground faults constitute the majority of all power system faults, single-pole-tripping and reclosing maximizes line power transmission capability by tripping only the faulted phase. Opening and closing of a single phase minimizes the system disturbance. Fast communications [8] minimize fault-clearing times and accelerate control actions. Normal Fast State Measurement Gen = Load Event Analysis V OK Monitoring I OK Automated Restoration Event Analysis Restoration Fast State Measurement Monitoring Alert G and/or L Shedding Islanding Extreme Emergency Fast Fault Clearance Auto Reclose Figure 2 Tasks That Multifunction Protective Relays Can Execute to Improve System Reliability EXTREME STATE In the extreme state, remedial action schemes can operate to reestablish generation-load balance. Multifunction relays include programmable logic capability and fast protection elements to implement complex remedial action schemes. Leon et al. [3] describe a two-contingency remedial action scheme that prevents the system from near voltage collapse operation. In this description, the power system consists of three areas (see Figure 3): Area 1: Heavy load concentration Area 2: Heavy generation concentration Area 3: Light load concentration Areas 1 and 2 are interconnected with three transmission links; Areas 2 and 3 are interconnected with two transmission links. The remedial action scheme to avoid voltage collapse is enabled when transmitted power from Area 2 to Area 1 is greater than 1100 MW, as Figure 4 illustrates. If two lines open under these conditions, the scheme sheds excess generation in Area 2 in a timely manner (less than one second). Multifunction relays can execute these tasks to prevent the system from collapsing. SEL White Paper 3

Area 3 Light Load Area 1 Heavy Load Line 1 Line 2 Line 3 Area 2 Real Power and Open Line Monitor Figure 3 Area 2 Generation Depends on the System Real Time Power Transmission Capability Line 1 Line 2 Line Open MW Line Open MW Two Lines Open Trip Excess Generation in Area 2 Line 3 Line Open MW + 1100 MW Figure 4 Remedial Action Scheme to Shed Area 2 Excess Generation When Two of the Transmission Lines Between Area 1 and Area 2 Are Open and the Transmitted Power From Area 2 to Area 1 Is Greater Than 1100 MW RESTORATION STATE Rapid system restoration is critical to minimize blackout duration. Automated restoration schemes and accurate fault location can accelerate the restoration process. Multifunction relays include reporting capabilities that indicate fault location, breaker status, protective element operation, etc. These reports provide a summary of the event that the system operator can use to speed-up system restoration. The ability to synchronize events within 1 µs facilitates and accelerates event analysis. 4 SEL White Paper

CONCLUSIONS The power system goes through alert and/or emergency states before collapsing. Transition from one state to another is not instantaneous; with timely and accurate information, there is enough time to activate appropriate control systems to effectively operate the power system. Multifunction protective relays include comprehensive monitoring capabilities that can detect the alert and emergency states, minimize system disturbance and prevent system collapse. REFERENCES [1] L. H. Fink and K. Carlsen, Operating Under Stress and Strain, IEEE Spectrum, Vol. 15, pp. 48 53, March 1978. [2] A. Guzmán, J. B. Mooney, G. Benmouyal, N. Fisher, Transmission Line Protection for Increasing Power System Demands, 55th Annual Conference for Protective Relay Engineers, College Station, Texas, April 8-11, 2002. [3] J. Leon, A. Jarquin, E. Mora, E. Godoy, Reliability Analysis for a Generation Shedding Scheme on the CFE Main Transmission Network, 29th Annual Western Protective Relay Conference, Spokane, Washington, October 22 24, 2002. [4] G. Benmouyal, E. O. Schweitzer, A. Guzmán, Synchronized Phasor Measurement in Protective Relays for Protection, Control, and Analysis of Electric Power Systems, 29th Annual Western Protective Relay Conference, Spokane, Washington, October 22 24, 2002. [5] G. Benmouyal, M. Bryson, M. Palmer, Implementing a Line Thermal Protection Using Programmable Logic, 30th Annual Western Protective Relay Conference, Spokane, Washington, October 21 23, 2003. [6] S. E. Zocholl and A. Guzmán, Thermal Models in Power System Protection, 26th Annual Western Protective Relay Conference, Spokane, Washington, October 25 28, 1999. [7] D. Hou, A. Guzmán, J. B. Roberts, Innovative Solutions Improve Transmission Line Protection, 24th Annual Western Protective Relay Conference, Spokane, Washington, October 21 23, 1997. [8] K. C. Behrendt, P.E., Relay-To-Relay Digital Logic Communication for Line Protection, Monitoring, and Control, 51st Annual Georgia Tech Protective Relaying Conference, Atlanta, Georgia, April 30 May 2, 1997. SEL APPLICATION GUIDES Several SEL application guides with recommendations to improve power system reliability are available: 1. Applying the SEL-321 Relay on Series-Compensated Systems http://selinc.com/appguide/200011.pdf 2. Applying the SEL-5040 Power System Report Manager http://selinc.com/appguide/200008.pdf SEL White Paper 5

3. Breaker Failure Scheme Provides Fast Clearing for Phase Faults and Standard Clearing for Ground Faults Using the SEL-352 Relay http://selinc.com/appguide/200003.pdf 4. Fault Location and Fault Type Data Retrieval Using an SEL-2020/2030 Communications Processor (A JOB DONE Example http://selinc.com/appguide/200101.pdf 5. Implementation of a New Communication-Aided Tripping Scheme Using the SEL-321 MIRRORED BIT Function http://selinc.com/appguide/9614.pdf 6. Improve POTT Scheme Security by Adding Blocking to a Weak Third Terminal http://selinc.com/appguide/9705.pdf 7. Improve Security For Carrier Holes on DCB Schemes Using SEL Distance Relays http://selinc.com/appguide/9612.pdf 8. Making Trip Circuit Monitor Logic With SELOGIC Control Equations http://selinc.com/appguide/9608.pdf 9. Providing Automated Primary/Alternate Source on Distribution Feeders http://selinc.com/appguide/9702.pdf 10. SEL-321 Relay Load Encroachment Function Setting Guidelines http://selinc.com/appguide/9310.pdf 11. Setting the Zero-Sequence Compensation Factors in SEL-321 Relays to Avoid Overreach in Mutual Coupled Lines http://selinc.com/appguide/9803.pdf 12. Single-Pole/Three-Pole Autoreclose Function for Single Breaker Applications in the SEL-321 Relay Using SELOGIC Control Equations http://selinc.com/appguide/9708.pdf 13. Underfrequency Load Shedding With The SEL-387E Relay http://selinc.com/appguide/200016.pdf 14. Using Contact Inputs to Detect DC Grounds http://selinc.com/appguide/9901.pdf 15. Using SEL-351s and SEL-351Rs to Provide Automated Load Restoration for Distribution Feeders http://selinc.com/appguide/9806.pdf 16. Using SEL-421 Relay Synchrophasors in Basic Applications http://selinc.com/appguide/200208.pdf 17. Using SELOGIC Control Equations to Provide Separate Trip Coil Monitor (TCM) Alarm Outputs in the SEL-321 Relay When Applied to Two-Breaker Line Terminals http://selinc.com/appguide/9718.pdf 18. Using the SEL-352 Relay to Avoid Generator and System Damage Due to a Slow Synchronizing Breaker http://selinc.com/appguide/9721.pdf 6 SEL White Paper

19. Voltage Control Element for the SEL-387E Relay http://selinc.com/appguide/200017.pdf SEL TECHNICAL PAPERS Following is a list of SEL technical papers that discuss power system event analysis and reliability: 1. Advanced Application Guidelines for Ground Fault Protection http://selinc.com/techpprs/6121.pdf 2. Analysis of Event Reports http://selinc.com/techpprs/6002.pdf 3. Application Guidelines for Ground Fault Protection http://selinc.com/techpprs/6065.pdf 4. Assessing the Effectiveness of Self-Tests and Other Monitoring Means in Protective Relays http://selinc.com/techpprs/6065.pdf 5. Attack and Defend Tools for Remotely Accessible Control and Protection Equipment in Electric Power Systems http://selinc.com/techpprs/6132.pdf 6. Avoid Generator and System Damage Due to a Slow Synchronizing Breaker http://selinc.com/techpprs/6062.pdf 7. Capacitive Voltage Transformers: Transient Overreach Concerns and Solutions for Distance Relaying http://selinc.com/techpprs/6005.pdf 8. Concerns About Intrusions into Remotely Accessible Substation Controllers and SCADA Systems http://selinc.com/techpprs/6111.pdf 9. Digital Communications for Power System Protection: Security, Availability, and Speed http://selinc.com/techpprs/6083.pdf 10. Electronic Security of Real-Time Protection and SCADA Communications http://selinc.com/techpprs/6150.pdf 11. Electronic Security Risks Associated With Use Of Wireless, Point-to-Point Communications in the Power Industry http://selinc.com/techpprs/6144.pdf 12. Implementing Distribution Automation and Protection http://selinc.com/techpprs/6151.pdf 13. Improved Sensitivity and Security For Distribution Bus and Feeder Relays http://selinc.com/techpprs/6042.pdf 14. Innovative Solutions Improve Transmission Line Protection http://selinc.com/techpprs/6063.pdf SEL White Paper 7

15. International Drive Distribution Automation and Protection http://selinc.com/techpprs/6114.pdf 16. Measuring and Improving DC Control Circuits http://selinc.com/techpprs/6081.pdf 17. Measuring and Improving the Switching Capacity of Metallic Contacts http://selinc.com/techpprs/metallic_contacts.pdf 18. Microprocessor Relay Capabilities Improve PECO s Protection, SCADA, and Maintenance http://selinc.com/techpprs/6077.pdf 19. New Ground Directional Elements Operate Reliably for Changing System Conditions http://selinc.com/techpprs/6026.pdf 20. Protecting a 138 kv Phase Shifting Transformer: EMTP Modeling and Model Power System Testing http://selinc.com/techpprs/6136.pdf 21. Relay-to-Relay Digital Logic Communication for Line Protection, Monitoring, and Control http://selinc.com/techpprs/6029.pdf 22. Reliability Analysis for a Generation Shedding Scheme on the CFE Main Transmission Network http://selinc.com/techpprs/6141.pdf 23. Reliability Analysis of Transmission Protection Using Fault Tree Methods http://selinc.com/techpprs/6060.pdf 24. Resolving Digital Line Current Differential Relay Security and Dependability Problems: A Case History http://selinc.com/techpprs/6140.pdf 25. Statistical Comparison and Evaluation of Pilot Protection Schemes http://selinc.com/techpprs/6030.pdf 26. Synchronized Phasor Measurement in Protective Relays for Protection, Control, and Analysis of Electric Power Systems http://selinc.com/techpprs/6139.pdf 27. The Effect of Multiprinciple Line Protection on Dependability and Security http://selinc.com/techpprs/6109-paper-wprc.pdf 28. Thermal Models in Power System Protection http://selinc.com/techpprs/thrmodel.pdf 29. Tools for Protecting Electric Power Systems From Electronic Intrusions http://selinc.com/techpprs/6130.pdf 30. Transmission Line Protection for Increasing Power System Requirements http://selinc.com/techpprs/6122_paper_20020401.pdf 31. Trip and Restore Distribution Circuits at Transmission Speeds http://selinc.com/techpprs/6082.pdf 8 SEL White Paper

32. Understanding, Predicting, and Enhancing the Power System Through Equipment Monitoring and Analysis http://selinc.com/techpprs/6104.pdf SEL UNIVERSITY COURSES SEL University offers the following courses in power system automation and protection: PROT 301: Power System Protection for Technicians PROT 401: Power System Protection for Engineers PROT 403: Distribution System Protection PROT 405: Industrial Power System Protection PROT 407: Transmission Line Protection PROT 409: Generation System Protection PROT 411: High Voltage Power Transformer and Bus Protection APP 300G: SEL-300G Generator Relay APP 311L: SEL-311L Line Current Differential Relay APP 351: SEL-351 Directional Overcurrent and Reclosing Relay APP 421: SEL-421 Protection, Automation, and Control System APP 87: SEL-387 and SEL-587 Percentage Restrained Differential Relay APP 403: Enhanced Distribution Protection APP 405: Industrial Motor Protection APP 734: SEL-734 Revenue Metering System TST 101: SEL Relay Testing Basics TST 103: SEL Feeder Relay Testing TST 107: SEL Line Relay Testing IA 301: Integration and Automation Fundamentals IA 303: SEL Communications Processor IA 305: Drop-In Control House Fundamentals MGMT 201: Power System Protection for Managers MGMT 203: Power System Asset Management Copyright SEL 2003 (All rights reserved) Printed in USA 20030916 SEL White Paper 9