Synergy - Applications and Use

Similar documents
ikon AVS EURO MODULES Euro Plates

MATRIX 2 Podule. Description

ikon AVS Tuned in to Educational Audio Visual Requirements

Reliability through Quality and Simplicity

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers. P/N: Rev 5

USER MANUAL. SL-10 Master Room Controller MODEL: P/N: Rev 4

USER MANUAL V/100V Power Amplifier MODEL: P/N: Rev 4

USER MANUAL RC-76M/RC-712M MODEL: P/N: Rev 3

USER MANUAL. RC-76R/RC-78R Room Controllers MODEL: P/N: Rev 2

AMP20. User Manual.

BT Duet 210. User Guide

USER MANUAL. RC-74DL Master Room Controller MODEL: P/N: Rev 4

USER MANUAL. SL-1N Master Room Controller MODEL: P/N: Rev 1

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-74DL Master Room Controller. P/N: Rev 5

UK s best selling phone brand. User Guide. BT Duet 210. Corded Phone

SoundwebTM. Installation Guide

CLOUD CX261 Single Zone Mixer

BT Decor User Guide

USER MANUAL. RC-43SL 6-Button Room Controller MODEL: P/N: Rev 3.

MPS01. Paging and Emergency Microphone

bhi bhi DSP Noise Cancelling Products from bhi NEIM 1031 MKII bhi Ltd 22 Woolven Close Burgess Hill West Sussex RH15 9RR England

APT20. User Manual.

USER MANUAL. RC-43SL 6-Button Room Controller MODEL: P/N: Rev 1.

Electro Magnetic Compatibility (EMC)

PRE116/126. User Manual.

SoundwebTM. Installation Guide

EN54-16 COMPLIANT HARDWARE BYPASS MICROPHONE PORTS 12 ANALOGUE AUDIO INPUTS 12 GPIO INPUTS & 12 OUTPUTS 12 ANALOGUE AUDIO OUTPUTS

2. How do the input wall plates connect to the receiver? UTP or STP cables (cat5e/6). Some wallplates need one and some need 2 Cat5 cables

STUDIO 1800 OPERATING INSTRUCTIONS MANUFACTURED IN THE UK

AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL

USER MANUAL. VS-311H Automatic HDMI/Audio Switcher MODEL: P/N: Rev 3

PXR 1506 / WATT MIXER AMPLIFIER

Kramer Electronics, Ltd. USER MANUAL. Model: RC-52N. Room Controller

MPS10 - MPS50. Modular Paging and Emergency Microphones

AUD-220 Installation Guide

Stereo / Mono. Audio Power Amplifier W. Introduction. Applications

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: 905xl Power Amplifier. P/N: Rev 3

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VM-24H 2 Input 1:4 HDMI Distributor. P/N: Rev 4

Artistic Licence. Mica. User Guide. Mica User Guide. Version 1-1

TURBO HD TVI Bullet & Turret Camera

Issue G GLENSOUND ELECTRONICS LTD. Broadcast Equipment Manufacturers. Copper 29 Glensound Telephone balance Unit Handbook

DM-1 Installation & User Guide V 4.0

4-BUS PROFESSIONAL MIXING CONSOLE

SP-1200P POWERED SPEAKERS OWNERS MANUAL

AUD-340 Installation Guide

CPA 40 Two Channel Amplifier

AV-1600 DIGITAL AMPLIFIER OWNERS MANUAL

MAINS DISTRIBUTION UNIT MDU14-CO

OWNER S MANUAL GEQ 131/ 131LF GEQ 215/ 215LF GEQ 231. Single Channel 31 Band Graphic Equalizer. 2 Channel 15 Band Graphic Equalizer

SP-1800 OWNERS MANUAL

SP-1400P POWERED SPEAKERS OWNERS MANUAL

INFERNO DANTE NETWORK AUDIO SINGLE USER COMMENTARY BOX PRODUCT DETAILS

TECHCONNECT TC2-HDMI14 OWNERS MANUAL

Gobo Projector XP 80W

Wireless DMX Control. Show Performer DMX Controller. Stage Desk 48 DMX Controller

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

SES-SBA-150W USER MANUAL

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

INTEGRUS. LBB 3222/04 6-Channel Interpreter Desk with Loudspeaker. LBB 3422/20 Integrus Audio Input and Interpreters Module

Call Point Programmer User Guide

4K HDBase-T Matrix Kit

T L Audio INDIGO SERIES. User Manual PA-2001 VALVE PRE-AMPLIFIER. Tony Larking Professional Sales Limited, Letchworth, England.

ACCESS LINK DETAILED SPECIFICATIONS

AV DIGITAL AMPLIFIER OWNERS MANUAL

USER MANUAL. VP-311DVI Automatic DVI/Audio Switcher MODEL: P/N: Rev 3

Beresford Capella Headphone amplifier

bhi Ltd User Guide for bhi Dual In-Line Module stereo/dual channel DSP Noise Cancellation Module

high fidelity engineering since 1974 cd player

CL210A TELEPHONE & ANSWERING MACHINE

6222 Two Door Module Technical Operations Manual

TECHCONNECT TC2-HDMI41 OWNERS MANUAL

Operating Manual. Programmable Touchscreen Wallplate Control System

Network Bullet Camera. Quick Operation Guide

Product Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23

EA014 Whiteboard Speakers. Manual and installation instructions

LPT-C2 & LPT-C6 ListenPoint Standard & Advanced Control Unit (CU)

USER MANUAL. VM-28H 2 Input 1:8 HDMI Distributor. VM-216H 2 Input 1:16 HDMI Distributor MODEL: P/N: Rev 5

BGS 20T 100V/8Ω Background Music Loudspeakers

Audio Zone Amplifier 2 x 20 watts Installation Guide

DSE2548 DSENET OUTPUT EXPANSION MODULE. DSEGenset DSE2548 COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF GEN-SET APPLICATIONS

CONTENTS. INTRODUCTION 3 Unpacking the Telephone 4. DESCRIPTION 5 General Description 5. INSTALLATION 10 Setting Up 10 Wall Mounting 11

PAR56 10MM UV LED PAR. user manual

USER MANUAL. VS Port RS-422 Matrix Switcher MODEL: P/N: Rev 5

Now available to purchase from

HD Fisheye Camera. User Manual UD01467B

Installation & Operation Guide

Kramer Electronics, Ltd. USER MANUAL. Model: VS-1616A. 16x16 Balanced Stereo Audio Matrix Switcher

NRX EVO 250 USER GUIDE.

SUGDEN AUDIO. DAP 800 Digital analogue pre-amplifier FBA 800 Floating bridge pure class A power amplifier INSTRUCTION MANUAL

A-300 Speed Dome. Quick Start Guide

4x4 HDMI 1.3 CAT5e Matrix Quick Installation Guide

T L Audio INDIGO SERIES. User Manual C-2021 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

Installation & Operation Guide

Integration Partners:

VE9121 Series Classroom Audio Management System

AMP Watt Audio Amplifier with RS-232 and IR Control. User s Manual CUSTOMER SUPPORT INFORMATION

bhi bhi SOUND ENGINEERING SOLUTIONS SOUND ENGINEERING SOLUTIONS NEIM 1031 bhi Ltd 22 Woolven Close Burgess Hill West Sussex RH15 9RR England

FPO MLC 62 RS EU. Simple and Easy-to-use A/V System Control MEDIALINK CONTROLLER FOR EUROPEAN JUNCTION BOXES. MediaLink

DM10 Active Monitors Owners Instructions

EMS10 - EMS50. Cameo specification sheet. Product Description

Transcription:

INDEX Introduction Page 1 Synergy Controllers Page 2 Models available Page 2 Attributes Page 3 Synergy Outputs Page 4 Screen control Page 4 12V Screen trigger Page 5 Alternative outputs Page 5 Synergy Inputs Page 6 PIR and push buttons Page 6 DC voltage inputs Page 6 IR Commands Page 7 RS232 Commands Page 7 Syn-Link Page 8 Panel Linking, Master / Slave Page 8 Panel Linking, Dual Master Page 9 Panel Linking, Equal Access Page 9 Syn-Link Applications Page 10 Audio Controller Page 10 Syn-Link Expansion Page 10 2 nd RS232 port Page 10 GUI Control Page 10 Audio Controller Page 11 Synergy - Applications and Use Environmental issues Page 12 Warranty Page 13

Introduction The ikon Synergy range of products provide a combination of cost - effective hardware with software packages allowing systems to be created that are greater than the sum of their parts true Synergy. At present the range consists of wall / dado / desk mounting control panels, an audio controller, a screen relay power pack and push button panels for aux inputs. The Synergy Range Controllers At present there are three controllers available, with others to follow. Two suitable for a single gang UK back box. One suitable for a double gang UK back box. Disclaimer The applications and attributes of Synergy controllers and software contained within this booklet have all been tried and tested, but at the time of printing, not all component parts featured may be available in quantity as production is ramped up. Please contact or your distributor to confirm availability. All Synergy controllers will fit a 35mm deep standard socket box or dado trunking back box. The use of a 44mm box will give more room for cabling but is not essential.

Attribute Details 1040 1080 2080 User - definable buttons Bidirectional RS232 IR port Outputs Inputs Syn-Link With internal LED illumination and can be user-labelled. Automatic label generation and printing is included as part of the configuration software. For control of the display or any other RS232 device. Load from libraries or user-configurable Each supports single or dual IR emitters for control of amplifiers, players, etc. Codes from built-in libraries or via captured device. Open collector outputs for external relays, indicators etc. Built-in screen, lift and power control routines. For use with external switches, PIR, etc. for additional control function or shutdown. RS232 port used for programming and the linking of panels. Also used to connect other Synergy peripherals (e.g. AU4 Audio controller) without additional programming. Software keys allow its use as a second, fully-configurable RS232 port for control, or with a PC running WinSyn for full GUI control. 4 8 8 1 1 1 1 1 2 2 2 2 1 1 2 1 1 1 Synergy Outputs Labelled on the unit as Screen relays, the two outputs provided on all controllers are an open collect type suitable for use with indicators and relays. One side of the load should be connected to the same +12V supply as the controllers; a screw terminal marked +V is provided for this purpose. The other side of the load is connected to Raise (for output 1) or Lower (for output 2). It is possible to use a higher external voltage supply than 12V if necessary; please refer to the application notes on the Synergy website for instructions. Screen Control There are three methods supported by the Synergy controllers: You can use external 12V DC relays for the power control as an alternative to the SPC-PP1, please see Alternative use of outputs on the next page for details.

12V DC triggered screens Controlling these requires the use of an external relay. Synergy Inputs All Synergy controllers have at least one control input that can be used with a push button or grounding circuit. In the application below using a PIR detector, note that some PIR s use a transistor as the output, which does not pull fully to 0V when activated. The Synergy control input 1 has an adjustable threshold to allow for this. Using the Synergy external inputs with a PIR or Push Buttons Alternative use of outputs The outputs can also be used for general purpose control of external indicators or relays. Using the Synergy external inputs with a DC voltage When isolated control is required, e.g. in parallel with a panel push button, the use of an opto-isolator is recommended.

IR Commands The Synergy configuration software contains an embedded IR library for many current devices. This library can be updated from the Synergy website either manually, or the software can be set to automatically update both the IR and RS232 libraries every time an active Internet connection is detected and the software started. For IR devices not contained within the library the codes can be captured using the IR Capture Podule available from and some dealers. We also offer a code capture service should you wish to send us the handset for capture. In early summer 2011 an alternative version of the Synergy 2080 controller will be available, with onboard IR capture facilities. This can be used to capture codes for direct use or the codes can be stored in a library module. RS232 Commands Syn-Link All Synergy controllers are fitted with a Syn-Link port. This is a special purpose RS232 connection used to program the Synergy controllers from a host PC running the Synergy configuration software. It is also the method of connecting Synergy accessories and expanding the system beyond the capacity of the controller on its own. Incorporated Syn-Link Applications The following applications are enabled from the Synergy software and also expansion of the system via the Syn-Link port. Panel Linking A pair of Synergy panels can be linked in three different ways. Master / Slave The RS232 commands are also embedded within the Synergy software, but when a new device needs adding, this can be done from within the RS232 editor integrated in the Synergy configuration software. Commands can be entered as Hex, ASCII or control characters, and the code can be tested by linking the computer running the software to the RS232 device to be controlled. Any replies can also be seen and captured. When a new RS232 library file or IR file is added to your library, there is an option to forward this to ikon for inclusion in the global libraries with a credit to the supplier of the file along with any contact detail you may wish to include. (This facility can be disabled or files submitted anonymously.) Operations on the slave panel only control devices connected to the slave panel while operations on the master panel control both its controlled devices as well as the ones connected to the slave. The buttons on the slave panel reflect the current status in both modes of operation. The panel linking can be enabled and disabled using the auxiliary inputs on the master panel, (e.g. from a room divide sensor).

Dual Master Syn-Link - Applications Audio Controller Enabling the Syn-Link port for use with the Synergy audio controllers enables control of four audio inputs along with level control and microphone on/off, with minimal configuration. No programming of the audio controller is required. PC Control With no panel linking enabled each panel operates as an independent system. With panel linking enabled either panel controls both, allowing two-way control. The linking can be configured to use either panels auxiliary inputs or require both to be activated. This is ideal for use with key switches for dual, key confirmation of linking. First Takes Precedence The Syn-Link port can be enabled for use with a downloadable utility that runs on a PC connected to the panel. When run, the utility interrogates the panel and creates a graphic of the correct panel with button labels allowing two-way operation of the panel from the PC screen as well as the physical panel. Syn-Link - Expansion Two software keys are available to expand the control functions of the Synergy panel. 2 nd RS232 Using a purchased software key the Syn-Link port can be enabled as a completely configurable RS232 port for additional control of RS232 devices. This also allows the panel to be integrated into a BMS system using a suitable 3 rd -party interface. Full GUI With panel linking enabled (from either or both panels as above) the first panel to be operated takes control of the system locking the other panel out until the system has been shutdown. Using the WinSyn software (available from www.ikonavs.com/synergy), Complete graphical user interfaces can be created and run on a PC connected to the Syn-Link port. Requiring a purchased software key to operate, this software allows access to the eight panel buttons and a further eight embedded buttons, enough for transport control of IR devices. Multiple page screens can be created presenting the user with customisable button layouts for ease of use.

Synergy Audio Controller Electromagnetic Compatibility The current range of Synergy audio controllers consist of four models. AU4L AU4P AB4L AB4P Four unbalanced stereo line level inputs on phono / RCA sockets and a mixed microphone, all routed to an unbalanced stereo output, also on phono / RCA sockets. As AU4L but incorporating a 20 watt per channel amplifier as well as the line level outputs. Four balanced stereo line level inputs on detachable screw terminals and a mixed microphone, all routed to an balanced stereo output, also on detachable screw terminals. As AB4L but incorporating a 20 watt per channel amplifier as well as the line level outputs. When connected to a Synergy controller input selection can be assigned to any button. When an input is selected the volume can be adjusted with any change stored against the input. Dip switches on the rear of the unit allow either full range (+15 to 48dB ) or limited range (+15dB to 15dB), The default level can also be set as fixed (0dB), or retaining the last setting. The microphone input has switchable phantom power and a selectable hipass filter. It also has its own level control and EQ. The microphone is mixed with the program audio after the remote volume facility and the microphone can be turned on and off either remotely via the Synergy panel, or using a push button connected to terminals on the audio controller. The unit can be used as a stand-alone RS232-controlled input selector and level controller. This equipment has been designed, manufactured and tested to conform to the European EMC directives EN55103-1 & EN55103-2 for classifications E2 and E4. Additional EMC information for installation to comply with the EMC directives 2004/108/ec and SI 2006 No. 3418 is available on the ikon website. Warranty In common with most ikon Products, the Synergy series carry a 3 year RTB warranty that covers parts and labour only. There are no user serviceable parts inside and the unit should be returned to the supplier for warranty repair. Full details of our warranty are available on the Ikon website. Manufacturers Information The Synergy series is manufactured in England by ikon AVS Ltd. For service or warranty advice please initially contact your supplier. Alternatively contact the manufactures at:- ikon AVS Ltd Unit 238 Ikon Trading Estate Droitwich Road Hartlebury Worcestershire DY10 4EU Telephone: +44 (0) 1299 250991 Fax: +44 (0) 1299 250983 Website:- www.ikonavs.com Technical support email:- support@ikonavs.com

Environmental The Synergy series are not IP rated and should not be used in bathrooms, outdoors or similar damp environments unless provided with additional protection with a suitable IP rating. WEEE Under the Waste Electrical & Electronic Equipment (WEEE) Directive & Regulations, when customers buy new electronic equipment from ikon AVS they are entitled to:- 1. Send old equipment back for recycling on a one-for-one, likefor-like basis. 2. Send the new equipment back for recycling when it ultimately becomes waste. Recycling instructions and documentation for both Customers and Recyclers is available on the Ikon website. Producer Registration Number: WEE/HD0052TQ ikon AVS Ltd Unit 238 Ikon Trading Estate Droitwich Road, Hartlebury Worcestershire, DY10 4EU England Telephone: +44 (0) 1299 250991 Fax: +44 (0) 1299 250983 www.ikonavs.com V1.01/2011