IPV-01E. User Manual. Há dez anos trazendo as melhores soluções em tecnologia para sua empresa. Version 1.0 RECYCLABLE

Similar documents
TEX-100. Ethernet Extender User Manual

VDTU2-B110 VDSL2 LAN Extender

IPA-48S/IPA-24S. User Manual. Version 1.1 RECYCLABLE

Ethernet over VDSL2 Converter

TD-8616 ADSL2/2+ Ethernet Modem

10/100 VDSL2 Ethernet Extender Kit over Single Pair Wire 1km

VDTU2A-304. VDSL2 Bridge LAN Extender with 4-Port Switch

FOUR-PORT ADSL ROUTER. KD319MUI ADSL Router User Manual

Ethernet over VDSL2 4-Port Managed Access Multiplexer UVE7314-M User Manual

FOUR-PORT ADSL ROUTER. KD319EUI ADSL Router User Manual

KD216 VDSL Router User Manual

BiPAC 8200M. BiPAC 8200N

FOUR-PORT ADSL ROUTER. KD319RI ADSL Router User Manual

1-Port 10/100/1000T Ethernet over Coaxial Converter

GAN9.9T153A-B Product Specifications

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

GV-POE Port Gigabit 802.3at Web Management

OV504WN Parameters and Specifications

GV-POE2401-V2 24-Port 802.3at Web Management PoE

1-Port 10/100/1000T Ethernet to VDSL2 Converter w/ G.vectoring

1-Port Gigabit Ethernet over Coaxial Converter

DW- SW-PoE-24M. wwww.denwaip.com

BiPAC 7800(N) (802.11n) Dual WAN ADSL2+ Firewall Router. Quick Start Guide

Contents Overview... 3 Features... 4 Applications... 4 Specifications... 5 Packing... 6 Appearance... 7 Front Panel... 7 Rear Panel...

Ethernet over Coaxial Converter VC-232G

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

BiPAC 8501 R3/ 8521 R3

Broadband High-Speed DSL Modem User Manual

1-Port BNC/RJ11 to 4-Port Gigabit Ethernet Extender

AH505R. 5.7Mbps G.SHDSL.bis/EFM Router

BEC 8920AC Ultimum The Ultimate Residential Gateway with ac VDSL2/ADSL2+/Bonded/FTTH Quick Start Guide

4-Port 10/100/1000T Ethernet to VDSL2 Bridge w/g.vectoring

Installing the Cisco Unified Videoconferencing 3545 MCU

Ethernet over VDSL2 Converter VC-201A / VC-202A

SD24GS. 24-Port Web Smart Gigabit Ethernet Switch. User s Manual

Gigabit Ethernet over Coaxial Converter. VC-232G User s Manual

BiPAC 7404VNOX BiPAC 7404VNPX

Ethernet over VDSL2 Converter/Bridge VC-231G VC-234G

Ethernet over VDSL2 Converter VC-201A / VC-202A / VC-204

BiPAC 6404VGP R3. VoIP/ g Broadband Firewall Router. Quick Start Guide

SWP-0208G, 8+2SFP. 8-Port Gigabit Web Smart Switch. User s Manual

Wireless g AP. User s Manual

BiPAC 7401V(G)PX. 3G/ VoIP/ (802.11g) ADSL2+ Firewall Router. Quick Start Guide

1-Port 10/100/1000T 802.3at PoE+ Ethernet to VDSL2 Converter

IEEE BASE-T IEEE 802.3u 100BASE-TX. ITU-T -G.993.1(VDSL) -G compatible

ES Port Managed Gigabit Switch with 4 SFP ports

IP DSLAM IDM-168. To meet the increasing demand for high-speed internet access and triple play application service. The next generation

TCD channel H.264 Video Encoder Hardware User s Manual (DC 12V) Ver. 2010/10/29

BiPAC 7800DX(L) Dual-Band Wireless-N 3G/4G LTE (VPN) ADSL2+ Router. Quick Start Guide

User Guide TL-R470T+/TL-R480T REV9.0.2

TEW-211BRP. Wireless AP Router. User s Manual

Gigabit SSL VPN Security Router SG-4800

Wireless 11n Smart Repeater AP (1T1R)

L Port 10/100/1000T PoE + 2-Port Gigabit SFP + Managed Switch

CTX 1000 VoIP Accelerator User Guide

ZAC Product Specification

1 Package Contents 2 Hardware Installation 2.1 Safety Precautions 2.2 Physical Connection 2.3 LED Definitions 3 Basic System Configuration 3.

BiPAC 7800VDP(O)X. Dual-band Wireless-N VoIP ADSL2+ (VPN) Router. Quick Start Guide

Communication adapter RS485/422 over the Ethernet ELO E222. User manual

Smart Managed PoE-Powered 5-Port Gigabit Switch

IEXT224-4PH-L IEXT224-4PH-R Long Reach POE Extenders

Industrial 1-port RS422/485 Modbus Gateway

10/100/1000Mbps 16/24-port Web Smart Gigabit Ethernet Switch GSW-1600S/GSW-2400S. User s Manual

exp-s1110pe PoE+ Gigabit Ethernet Extenders

Table of Contents. CRA-200 Analog Telephone Adapter 2 x Ethernet Port + 2 x VoIP Line. Quick Installation Guide. CRA-200 Quick Installation Guide

24-Port VDSL2/ADSL2+ with 2-Port Gigabit TP/SFP Combo IP DSLAM

High performance access device

Setting Up Your Cisco Unified Videoconferencing 3515 MCU

1. Press "Speed Test" to find out your actual uplink and downlink speed.

24 port gigabit copper PoE + 4x SFP smart-managed

DPX-400-S-BT-DSL600A

QUICK START GUIDE. Pepwave Express. Quick Start Guide. Pepwave Express. Nov Pepwave

Hyperion INTELLIGENT GIGABIT SWITCH

WiFi-Repeater User Manual. Quick Installation Guide(Q.I.G.) REV.1.2

Industrial 2-port RS422/485 Modbus Gateway

10/100/1000Mbps. Gigabit Ethernet Switch GSW-2401/GSW User's Manual

The RFS-105 / RFS-108 is a high-performance Fast Ethernet switch, with all ports capable of 10 or 100Mbps auto-negotiation operation.

NGSME16T2H. (16-port 10/100/1000Base-T + 2 Gigabit SFP L2+ Management PoE Switch)

RGS-7244GP / RGS-7244GP-E

User s Manual ADSL Router Modem DB Ethernet Ports

RTA04W ADSL2+ 11b/g HOME GATEWAY. Technical Datasheet

PowerLine HD. user manual. Model * INT UM

Peplink SD Switch User Manual. Published on October 25th, 2018

Revision: 2.0. User's Manual

User Manual. Rev:

VAC 50/60Hz Power Adapter

ex-s1110-xt Gigabit Ethernet Extenders

E1/DS1/DTE IP 6610 Router/Bridge Box

V102M-PD. 100Mbps VDSL2 LAN Extender with 802.3af PoE PD embedded

28 Port Fiber Gigabit with 10G SFP+ Management Switch

NGSME48T2H. (48-Port 10/100/1000Base-T Gigabit Combo TP/SFP Layer 2+ Full Management High Power PoE Switch)

BiPAC 9800(N) (802.11n) Fiber Optical Router. Quick Start Guide

RGS-7168GCP / RGS-7168GCP-E

External VDSL Range Extender. User manual

Welcome. Unleash Your Phone

Content 1 OVERVIEW HARDWARE DESCRIPTION HARDWARE INSTALLATION PC CONFIGURATION GUIDE... 5 WEB-BASED MANAGEMENT GUIDE...

Gigabit SSL VPN Security Router

Atrie DB108-E ADSL MODEM. User Manual V1.1

User Manual. AC ac Wireless Access Point/Router. Model WAC124. NETGEAR, Inc.

Transcription:

IPV-01E User Manual Version 1.0 RECYCLABLE Há dez anos trazendo as melhores soluções em tecnologia para sua empresa.

AMENDMENT HISTORY Version Date Description V1.0 Oct, 2014 New release 2

Contents AMENDMENT HISTORY... 2 Contents... 3 1 Introduction... 4 1.1 IPV-01 Series Overview... 4 1.2 IPV-01E Specification... 5 2 Hardware Setup and Startup... 6 WARNING INSTRUCTIONS... 6 2.1 Description of Hardware... 7 2.1.1 Front Panel... 7 2.1.1.1 DSL ports... 7 2.1.1.2 Electrical Ethernet Port RJ45... 7 2.1.1.3 DIP Switch... 7 2.1.1.4 System LED... 8 2.1.1.5 Reset button... 8 2.1.2 Rear Panel... 8 2.2 Accessory Parts check... 9 3 EmWeb Setup and Startup... 10 3.1 Status... 12 3.2 LAN... 14 3.3 WAN... 15 3.4 Diagnostics... 17 3.4.1 Ping... 17 3.4.2 DSL Tone... 17 3.5 Admin... 20 3.5.1 Commit/Reboot... 20 3.5.2 CO/CPE... 20 3.5.3 Backup/Restore... 21 3.5.4 System Log... 21 3.5.5 Password... 22 3.5.6 Firmware Upgrade... 22 3.6 Statistics... 23 3.6.1 Interface... 23 3.6.2 VTU-O DSL (In CO Mode)... 24 3.6.3 DSL (In CPE Mode)... 27 i 3

1 Introduction Thank you for choosing the IPV-01E as your broadband access solution. This manual will help you with the setup and configuration of your product. 1.1 IPV-01 Series Overview IPV-01 Series can play a role of 1-port VDSL2 COT ( Central Office Terminal) or RT (Remote Terminal). IPV-01 Series uses profile 30a to deliver downstream 200 Mbps and upstream up to 100 Mbps traffic on short loops. It is designed to support the wide deployment of high speed connection and offers the user many advanced services such as voice, high speed data, and video on demand. Such application is suitable to use on residential and enterprise for broadband high speed service demand on downstream and upstream direction. The application scenario is shown as below. IPV-01E Application Scenario Switch One point to point Internet Multiple with chassis Building or apartment -4

1.2 IPV-01E Specification System Features DSL Ports 1-port VDSL2 subscriber interface Comply with ITU-T G.993.1 (VDSL), ITU-T G.993.2 (VDSL2) 8a/b/c/d, 12a/b, 17a, 30a per-port basis VDSL2 Profiles Provide rates up to 200 Mbps in the downstream and 100 Mbps upstream direction Power back-off algorithm Ethernet over VDSL Support resynchronization Support RFI configuration Support VDSL profile setup Support virtual noise to improve stability VDSL2 Profiles: 8a, 8b, 8c, 8d, 12a, 12b, 17a and 30a 4-position DIP Switch Selectable CO or CPE mode Selectable 30a or 17a (VDSL2 Profile) Selectable Band plan (Symmetric or Asymmetric) Selectable target SNR margin (6dB or 9dB) Transparent VLAN Bridging Transparent IGMP Multicast 1*LAN Interface: 1*GIGA RJ-45 connector LED: Power On/Off LAN: GIGA/100 ACT/LNK Half/Full Duplex, VDSL: CO/CPE, Idle(off)/Trained(flashing)/Link(ON) Compatible with major VDSL2 DSLAMs Protocols Support IGMPv1, v2, v3 snooping SysLog Client Interface/LED Uplink Giga Ethernet RJ45 Subscriber VDSL RJ11 LED PWR CO/CPE VDSL Link( Idle/Trained/Link) Ethernet LINK 1000/100 FD/HD Management Ethernet Web/TELNET management Remote in-band Web/ TELNET management Firmware upgradeable via HTTP Operating Requirements Operating Temperature: -10 to 45 C Storage Temperature: -40c to 80 C Operating Humidity: 5% to 90% RH non-condensing Dimension and Weight DESKTOP AND WALL MOUNT TYPE DIMENSION: 96.5 MM(D)X73.4 MM(W)X23.0 MM(H) WEIGHT: 161G Power Source Input 9V Power Consumption: 8 Watts Certifications EMC FCC Part 15 Class A CE-EMC Class A Safety EN60950-1 -5

2 Hardware Setup and Startup WARNING INSTRUCTIONS Before installing IPV-01E, the following safety instructions must be complied. 1. All installation, repair or replacement procedures must be performed by qualified service personnel. 2. The maximum recommended operating temperature for the IPV-01E is 45ºC. Care must be taken to allow sufficient air circulation. 3. The connections and equipment that supply power to the IPV-01E should be capable of operating safely within the maximum power requirements of the IPV-01E. 4. Do not allow anything to rest on the power cord, and do not locate the product where the power cord can be stepped on. Do not touch exposed connections, components or wiring when power is present. 5. To reduce the risk of fire or any other malfunction and damages to the IPV-01E, use the cables and power adapter provided in the package. 6. Do not operate this product with panels removed or with suspected failure or damage to electrical components. 7. IPV-01E is not water-proofed. Never place or install the product in a wet location unless specially designed waterproof protection is present. itas will not be responsible for any damages or injuries to the IPV-01E DPU, environment, or operating personnel if any of the safety instructions described above are violated or operating the device in the non-recommended conditions. -6

2.1 Description of Hardware 2.1.1 Front Panel 2.1.1.1 DSL ports - One RJ11 DSL ports 2.1.1.2 Electrical Ethernet Port RJ45 - One automatic MDI/MDI-X 1000/100/10 BASE T Ports Pin Signal Name 1 Transmit Data plus (TD1+) 2 Receive Data minus (RD1-) 3 Transmit Data plus (TD2+) 4 Transmit Data plus (TD3+) 5 Receive Data minus (RD3-) 6 Receive Data minus (RD2-) 7 Transmit Data plus (TD4+) 8 Receive Data minus (RD4-) 2.1.1.3 DIP Switch Hardware interface to switch between some settings. DIP SWITCH position Up Down COT/RT Run VTU-O image Run VTU-R image 30a/17a VDSL2 profile is 30a VDSL2 profile is 17a SYM/ASYM Band plan is symmetric Band plan is asymmetric SNR 9dB/6dB Target SNR Margin 9dB Target SNR Margin 6dB -7

2.1.1.4 System LED System Status LEDs LED Condition Status PWR On Power On Off Power Off Slow blink DSL in discovery phase DSL Fast blink DSL in training/exchange phase On DSL in showtime phase CO On VTU-O Mode Off VTU-R Mode On Ethernet is link up LINK Blink Ethernet data transmitting and receiving Off Ethernet is link down FULL On Ethernet link is full-duplex mode Off Ethernet link is half-duplex mode 1000 On Ethernet link speed is 1Gbps Off Ethernet link speed is 10/100 Mbps 2.1.1.5 Reset button Reset button in the front panel can be used to reset the device settings to default configuration. Some reset actions: IPV-01E Reset Button Less than 2s More than 2s, less than 5s More than 5s No action Reboot the device Reboot to factory default configuration 2.1.2 Rear Panel The power output is in the rear panel. -8

2.2 Accessory Parts check Check the following items in your package. Contact our sales representatives if any item is missing or damaged. IPV-01E IP DSLAM DSL Cable (RJ11*1) Ethernet Cable (RJ45*1) Using a power supply with a different voltage rating will damage and void the warranty for this product. Adapter -9

3 EmWeb Setup and Startup System preparation IPV-01E contains 2 modes: CO and CPE, therefore there are 2 management IP ports for CO and CPE, respectively. Before configure the IPV-01E, please ensure as below: Set your computer s IP with the same network mask of management port of the IPV-01E (For example: if you connect to CO management port, its default management IP is 10.0.0.1/255.255.255.248; if you connect to CPE management port, its default management IP is 10.0.0.2/255.255.255.248) Then you can set computer s IP to: 10.0.0.3~5/255.255.255.0. Some default settings in IPV-01E: VTU-O VTU-R Host PC IP address 10.0.0.3~10.0.0.6 10.0.0.3~10.0.0.6 Default IP 10.0.0.1/255.255.255.248 10.0.0.2/255.255.255.248 Login account admin/system admin/system IGMP snooping Enable Enable DHCP Server None None 1. To access Web on the IPV-01E, one has to connect to the management port and enter URL below at web browser. The default IP address of the ports: CO management port: http://10.0.0.1 CPE management port: http://10.0.0.2 2. If you first time login the Web, the default User name/password as follows: User Name: admin Password: system Login to CO mode: Login to CPE mode: -10

Web provides a series of web pages that you can use to setup and configure the IPV-01E. These pages are organized into six main topics. You can select each of the following topics from the menu on the left-hand side of the main window: - Status: information about the current device status. - LAN: LAN interface settings. - WAN: VTU-O DSL settings of WAN. - Diagnostics: ping and DSL tone. - Admin: commit/reboot, CO/CPE, backup/restore, system log, password, F/W upgrade. - Statistics: interface, VTU-O DSL (CO mode), DSL (CPE mode). The changes made via web pages will immediately reflect in all elements of the network. The exact information displayed on each web page depends on the specific configuration that you are using. The following sections give you a general overview of the setup and configuration details. -11

3.1 Status This page simply shows the current device status and some basic settings of the device. User will be able to refresh the device status by clicking on Refresh button, otherwise the status will be refreshed every 10 seconds. In CO mode: -12

In CPE mode: -13

3.2 LAN This page is used to configure the LAN interface of IPV-01E. User can change the settings for IP address, subnet mask, IGMP snooping. Enter the desired data into the specified fields and click Apply Changes button to save the settings. -14

3.3 WAN This page is used to configure the parameters for VTU-O (CO mode) or bands (CPE mode) of IPV-01E. Please note if Software switch in Admin menu is disabled, user cannot modify this page. User can modify the Line, Channel, INM (Impulse Noise Monitor) profiles in this page. Enter the desired data into the specified fields and click Apply Changes button to save the settings. In CO mode: -15

In CPE mode: -16

3.4 Diagnostics Click on Diagnostics menu, the following options appear: 3.4.1 Ping This page is used to send ICMP ECHO_REQUEST packets to network host. The diagnostic result will then be displayed. Enter the host address and click on Go! button do display the diagnostic result. Ping result: 3.4.2 DSL Tone This page is used for DSL Tone diagnostics. Only ADSL2/ADSL2+/VDSL support this function. The tone number is displayed from 0~255. Before DSL tone diagnostics test: -17

Press Start button to start DSL tone diagnostic. The test result will take about 3 minutes, please wait while it is processing: -18

After DSL tone diagnostics test: -19

3.5 Admin Click on Admin menu, the following options appear: 3.5.1 Commit/Reboot This page is used to commit changes to system memory and reboot the system. Simply click on Commit and Reboot to activate this function. 3.5.2 CO/CPE This page is used to switch between the CO and CPE mode. User must decide whether to enable the software switch. If the software switch is enabled, the DIP switch will be disabled. Enter the desired data into the specified fields and click Apply Changes button to save the settings. After the mode is changed, device will reboot. Please wait while device is rebooting. -20

3.5.3 Backup/Restore This page is used to backup current settings to a file or restore the settings from the file which was saved previously. User also can reset the current settings to factory default. Click on Backup button to backup settings to file. User can set the file path. When settings are to be restored from a file, click on Browse button to find the file path, and click on the Restore button to restore the settings. Click on Reset button to reset settings to default. To reset VTUO and VTUR settings to default, click on ResetAll button. 3.5.4 System Log This page is used to set the system log. User can either disable or enable the system log function. After setting log level and display level, click on Apply Changes to save the settings. User can also save log into a file by setting the file path through Save button. Clear the log by clicking on Reset button. System log can be refreshed by clicking on Refresh button. -21

3.5.5 Password This page is used to set the account to access the web server of the router. Empty user name and password will disable the protection. Enter the desired options into the specified fields and click Apply Changes button to save the settings or reset the fields by clicking on the Reset button. 3.5.6 Firmware Upgrade This page is used to upgrade the firmware to the newer version. Please note that do not power off the device during the upload because this make the system unbootable. If it happens accidentally, please contact customer service for further assistance. User can select the firmware file by using Browse button. After the firmware file is selected, click on the Upgrade button to start the upgrade process, or click on the Reset button to reset the file path selected. -22

3.6 Statistics Click on Statistics menu, the following options appear: In CO mode: In CPE mode: 3.6.1 Interface This page is used to show the packet statistics for transmission and reception regarding to network interface. Click on Refresh button to refresh the statistics or Reset Statistics to clear and reset the statistics data. -23

3.6.2 VTU-O DSL (In CO Mode) This page is used to display the VTU-O DSL statistics. Click on Stop Auto-Refresh button to stop the auto-refresh. -24

-25

BitAlloc table: GainAlloc table: -26

3.6.3 DSL (In CPE Mode) This page is used to display the VTU-R DSL statistics. -27