ViewConn Pro VC-8200

Similar documents
Datasheet: FI-500 FiberInspector Micro-Fiber Optic Endface Inspection Scope with PortBright Illumination.

FOCIS Flex - No Wireless Fiber Optic Connector Inspection System User Guide

QUICK REFERENCE. Using the Battery

Test & Inspection. FOCIS Flex. Fiber Optic Connector Inspection System Quick Reference Guide. or (800) , (603)

Xi4 Quick Reference Guide

VFS 2 Video Fiber Scope User s Guide. Test & Inspection

Handheld Video Microscope

VIP-55. Operation Guide. Video Inspection Probe V

OTS-600 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities

VIS Video Inspection Scope

Datasheet: FI-7000 FiberInspector Pro

ConnectorMax Analysis Software DELIVERING FAST PASS/FAIL ASSESSMENT OF CONNECTOR ENDFACES

CONNECTORVIEW. Operation Guide. VIP-45 Software V

GVIS Video Inspection Scope

FOCIS Flex Fiber Optic Connector Inspection System User Guide

imac Intel 21.5" EMC 2389 Stand Replacement

Dell Inspiron XPS and Inspiron 9100 Service Manual

Datasheet: FI-7000 FiberInspector Pro

Essentials of Fiber to the Antenna: Fiber Inspection and Connectivity

VPC-64/ VPX-64 VIDEO POLE CAMERA OPERATION MANUAL

FOCIS Duel Fiber Optic Connector Inspection System User Guide

AFC-3000 Automated Optical Connector Ferrule Cleaner

VIP-45-WIFI. Operation Guide. Video Inspection Probe V *VIP-45 Probe Not Included With Wi-Fi Module

G500 SERIES MICROSCOPE OPERATION MANUAL For use with MFR# G502, G502T, G504, G504T, G505, G505T.

xr Fiber Platform User Guide

Removal and Installation8

FOCIS Flex Inspection

Transceiver Fiber Inspection and Cleaning

FiberExpress Brilliance Connectors

PowerBook G4 Aluminum 15" GHz PC Card Cage Replacement

Computer Assembly (Installing Mother Board & CPU)

Survival Laser SL-005PB Laser Parts Bundle Assembly & Operation Instructions

Copyright Black Box Corporation. All rights reserved.

DUAL-ARM MONITOR MOUNT For in. ( cm) desktop computer monitors

The Nureva Span ideation system. Installation guide. Single panoramic system

How to add a Second Drive to a Mac mini (2012) using the OWC Data Doubler SSD/2.5 Installation Kit

Unpacking and Installing the Flora 2512 UV Printer. Steps 1: Unscrew the 10mm bolts holding the top. Then remove the top and put in a safe place.

imac Intel 27" EMC 2429 SSD Dual Drive

Handheld Video Magnifier

To connect the AC adapter:

Written By: Walter Galan

VARIA UT800. Owner s Manual

FIP-400 FIBER INSPECTION PROBE NETWORK TESTING OPTICAL

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

Peel/Rewind Upgrade Kit

Written By: Walter Galan

ColorMaxLP Label Roll Rewinder

Replacing the SATA PCI Controller Card

TDM To MiniMech conversion ProceDure

Dell XPS M1530 Service Manual

FRU Installation Notes Virtuo Monitor Glass Replacement

Megatouch FORCE Monitor Chassis Board Replacement

MONARCH 9416 XL QUICK REFERENCE

User Manual. Trinocular Stereo Microscope

Inspiron 22. Service Manual Series. Regulatory Model: W17B Regulatory Type: W17B001

Macro View All in One Scope Description. 2. Features. 3. Package Contents

Test & Inspection. FOCIS Duel. Fiber Optic Connector Inspection System Quick Reference Guide. or (800) , (603)

256 Kbytes (1771-DRS) 1 Mbyte (1771-DRS1) 4 Mbytes (1771-DRS4) Installation Data

MVPplus Quick Reference Guide

MODULE & HANDPIECE HOLDER POWER SWITCH LED INDICATORS USB PORT (SERVICE) REMOTE INTERLOCK

MULTIMETER: YSI-ProDSS rev. 9/23/15

Upgrading and Servicing Guide

Ruger SR22. Operator s Manual RUGER SR22 SR9C SR40C 9E LMS-RMSR

4.1 General. 4 Replacement Procedures

Testing Optical Feeds in Wireless Systems Remote Radio Units (RRU) and Distributed Antenna Systems (DAS)

Replacement Instructions

The following illustration demonstrates what you would see when the print jet nozzles are properly leveled.

COGNEX. DataMan 100 Verifier. Quick Reference Guide

Dell XPS L702X Service Manual

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Quicksilver 606 TR-606 CPU Upgrade

Survival Laser SL-002PB Laser Parts Bundle w/g-1 Lens Assembly & Operation Instructions

Part Number: 92P1476. h Battery pack. h Computer

AstroJet TM M2 Quick Start Guide

M40 Microscope User s Manual

ROV Response: ROV Response: ROV Response: ROV Response:

Survival Laser SL-001.4PB Laser Parts Bundle Assembly & Operation Instructions

Jouse. User s Guide. Revision 1.0. Prepared by: Compusult Limited 40 Bannister Street Mount Pearl, Newfoundland, Canada A1N 3C9

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

Inspiron Service Manual. 2-in-1. Computer Model: Inspiron Regulatory Model: P69G Regulatory Type: P69G001

PowerBook G4 Aluminum 15" GHz Heat Sink Replacement

Fiber Optic Distributed Temperature Sensors (B-DTS)

Table of Contents. Important Information... 4 Product Description... 4 Computer Requirements Windows Based PCs Mac OS X Based PCs...

User Guide. Version 2.

Upgrading and Servicing Guide

Manual 04 - Logic Board

Autofocus Video Inspection Probe G0382A. Product Introduction

Setting up an Intermec PM43 printer with InterDriver version M-0 or newer

Product Overview. Features

Dell Precision M4600 Owner's Manual

Installing imac Intel 27" EMC 2390 Dual HDD or

VISIBLE FIBER OPTIC FAULT LOCATOR

Led Illuminator and Light Stimulator. Model # LSD-1. Ver

BPL SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

If you are missing any of the following items, please contact Stanton Video immediately (602)

SSD Dual Drive Installation

WEB Revision T, May 2016 CommScope Actuators

ConnectorMax MPO Link Test Solution A COMPLETE MPO POLARITY, CONTINUITY AND CONNECTOR INSPECTION SOLUTION FOR SHORT FIBER LINKS (UP TO 5 KM)

Interactive WhiteBoard [ Conducting presentations become easier than ever ]

VARIA REARVIEW RADAR RTL510/ RTL511. Owner s Manual

Transcription:

ViewConn Pro VC-8200 1. Introducing ViewConn 2. Using ViewConn Pro 3. Optional Integrated Optical Power Meter 4. Specifications

Safety Fiber optic lasers use light wavelengths not visible to the human eye. All Lightel microscopes are eye-safe video microscopes. Nevertheless, all standard safety precautions should be followed.

Inspect at Every Step Manufacturing QC and Receiving System Assembly Installation System Testing Network Testing Maintenance Troubleshooting

Introducing ViewConn ViewConn was the first, and only, hand-held, all-inone inspection and cleaning device. ViewConn s integrated operation allows users to quickly and easily inspect, clean and reinspect, ensuring connectors are truly clean prior to mating. ViewConn s large 3.5 display provides clear, sharp images.

Introducing ViewConn Plus Save Time The ViewConn Plus dual microscope design, originated by Lightel, lets you easily inspect both male and female mated connector pairs without the time consuming need to change tips.

Introducing ViewConn Pro The Comprehensive Solution ViewConn Pro is an integrated system for fiberoptic connector inspection, evaluation, documentation and cleaning. This hand-held tool provides dual microscopes, touchscreen controls, Pass/Fail analysis and a cleaning cassette all in a single unit.

ViewConn Pro VC-8200 1 14 12 13 6 2 4 5 3 7 11 9 10 1. ViewConn adapter tip (INT) 2. ViewConn focus knob (INT) 3. Cursor touch pad 4. Left-click button 5. Right-click button 6. Wrist strap 7. 5 color touchscreen 8. Stylus and stylus holder 9. Power button 10. Probe focus knob (EXT) 11. CC-1 cleaning cassette 12. USB port 13. Ruggedized cover 14. Optional integrated power meter 8

ViewConn Pro ViewConn Pro is designed to fit your work style. With a fold out stand, a wrist strap for support when holding it and neck strap attachments at either top or bottom, ViewConn Pro gives you the flexibility to use it whatever way the job requires. Its Li-Ion battery begins to recharge automatically whenever it is attached to an AC outlet.

Inspecting Male Connectors When you turn ViewConn Pro on it will be set to inspect male connectors (patchcords and jumpers) the INT setting. Ensure that you have the proper tip in the tip receptacle at the top of ViewConn, then place the connector into the tip. Use the large black ViewConn focus knob to focus the image. If you are unable to focus the image, verify that the tip is fully screwed in and the connector is properly seated in the tip.

Cleaning Male Connectors Once you have inspected the fiber, if you need to clean it, open the cover of the CC-1 cleaning cassette, and, using moderate pressure swipe the connector ferrule from the top down on a clean section of the CC-1 cassette. Do not scrub the connector back and forth and do not reuse a section of cleaner. Reinsert the connector in the tip to verify that it is now clean. If clean, make sure that the mated connector is also clean, before installing or reinstalling. If the connector was not clean, repeat the procedure and again recheck.

Cleaning Male Connectors Wet Cleaning If you decide you need to wet clean a connector, use a solvent dispenser like the optional Chemtronics Electro-Wash pen dispenser to lightly wet a clean section of a CC-1 sheet. Less solvent is best. Always go from the wet portion to the clean dry portion. You always want to finish in a dry section of the sheet to be sure the solvent has been removed. Reinspect your connector as before to verify it is clean.

CC-1 Cleaning Cassette When you have used all three slots on a CC-1 cleaning sheet, pull the sheet out to advance it to the next sheet. The cassette cover must be open to advance the sheet. If you wish to tear off a sheet, first close the cover. (A quick twisting motion works best to tear off the sheets.) To install the CC-1 cleaning cassette, place the tab at the top of the CC-1 in the slot at the top of the cassette holder. Then push the cassette in the space until it clicks into place. If you wish to remove the cassette, push up on the small blue plastic tab at the base of the cassette and lift the cassette out.

Changing ViewConn Tips Key Slot All ViewConn tips are intended for use strictly with male connectors. Most ViewConn tips are universal tips, either PC or APC, for all connectors with the same ferrule size. All tips work for both single mode and multimode connectors. To install a ViewConn tip, align the tip s key with the slot in the tip receptacle and seat it. Once seated, screw the tip in clockwise until tight. To remove a ViewConn tip, unscrew it counterclockwise and lift out.

Inspecting Male APC Connectors APC connectors are angled and need tips designed specifically to view them. (Note the angle on the tip stem.) A male APC connector is keyed. The key should be directly to the front of ViewConn to provide the best image. Or you can simply turn the connector until it has the best contrast. Key Alignment Mark Improperly Keyed APC Connector Properly Keyed APC Connector

Inspecting Female Connectors To inspect female connectors (in bulkheads and patch panels) touch the INT portion of the touchscreen. It will change to read EXT. The image displayed will now be coming from the probe. The Field of View from the probe is wider allowing you to more easily locate the ferrule. With the correct tip installed for the connector type, place the tip of the probe into the adapter and use the focus knob on the probe to focus the image. If you are unable to focus, you may not have the probe tip fully inserted. Make sure it seats fully, and refocus.

Inspecting Female Connectors When you have focused on the ferrule, you can freeze it to examine it, enlarge and automatically center it, and then analyze it. Or you can choose to just immediately analyze it.

Changing Probe Tips Probe tips are held in place with a lock nut. Holding the probe, turn the lock nut counter-clockwise to loosen it fully, and then remove the tip. All tips have a slot and fit into the key at the top of the probe. Slide the new tip in place and slip the lock nut over the tip. Tighten the nut snugly if the tip is loose, it may not focus properly.

Probe Tips Most probe tips are for female connectors. (Universal male tips are available for the probe for special applications.) Female tips are specific to the type of connector being inspected. All tips work for both single mode and multimode connectors. Probe tips are available in a variety of styles for specialty applications including 60 angled tips extended tips and tips for ribbon connectors. (Visit the Series 2 Tips page on the Lightel website www.lightel.com for a list of all current probe tips.)

Using ViewConn Pro ViewConn Pro is simple to use. The main screen provides access to all the ViewConn Pro features and all the controls you need to view, capture and analyze connectors. Or work from the Quick View screen with large simplified controls and a large graphic battery level indicator.

Using ViewConn Pro Capturing an image is as simple as a touch of the screen. With another touch you can shift to the probe and save images from it.

Using ViewConn Pro You can digitally zoom the connector for a closer look. Individualize your power saving settings or set up a Wi-Fi connection.

Using ViewConn Pro You can easily go back and view any Analysis Report or image you have saved. Check to ensure you are running the most recent Lightel software update for ViewConn Pro.

Analyzing Connectors You can analyze connectors with one touch. Simply touch the green Analyze button in Quick View. No calibration is necessary. Just select Single mode or Multimode. The ConnectorView Plus software can be set to automatically save the Analysis Report or you can choose to save only selected reports. Again it s as simple as a touch of the screen. The data from each saved report is also automatically saved in a Summary Report.

Analyzing Connectors ConnectorView Plus software use IEC 61300-3-35 as the default standard for its analysis, but the acceptance criteria can be modified to allow for different corporate standards. Multiple standards can be stored and reused. A new Summary Report is automatically generated whenever criteria are changed. The Analysis Report shows that IEC 61300-3-35 was the standard used for this analysis.

ViewConn Pro Power Meter VC8-OPM installed in ViewConn Pro ViewConn Pro has an optional integrated power meter. This add-in module can be installed by Lightel or can be easily installed by the user. Two versions are available for standard or for higher power ranges. Universal 2.5mm and 1.25mm tips are included with each power meter. These tips work with both PC and APC connectors. Power readings can be taken and saved by themselves or linked to an Analysis Report.

Case ViewConn Pro comes in a reinforced soft case. With both a shoulder strap and handle, there is room enough for additional cleaning supplies and other tools. A tipbox with adjustable compartments capable of holding any ViewConn Pro tip is also included in the package.

ViewConn Pro Specifications ViewConn (Pro) Probe Field of View ~464μm x 346m Field of View ~660μm x 495μm Resolution 0.5μm detectable Resolution 0.5μm detectable Optical Sensor CMOS Optical Sensor CMOS Light Source Blue LED Light Source Blue LED LCD Display 5 LCD color touchscreen Power Supply USB2.0 connection with ViewConn Power Supply Battery Life Electrical Ports Dimensions (including ruggedized cover) Weight (including battery and ruggedized cover) Storage Memory Processor Internet Connection Li-Ion internally rechargeable battery or 12V DC adapter Adjustable automatic power saving Low battery indicator 3 hours (continuous) DC adapter plug port 1 USB2.0 port 186mm (H) x 218mm (W) x 44mm (D) 1.4kg 8GB SSD 1GB Atom Z530 Wi-Fi Output Dimensions Software (pre-loaded) Operating System ConnectorView TM Plus Analysis Time USB2.0 plug 35mm ø x 175mm (without cap) Windows XP Pass/Fail Analysis Full screen, touchscreen operation ~4 seconds (average)