OPERATING AND SERVICE MANUAL. Universal Interface Device 45

Similar documents
OPERATING AND SERVICE MANUAL. Universal Interface Device 47

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Resolver to Digital Expansion Board

Profibus DP Expansion Board

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

DCM Digital Control Modules

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

I/O SIGNAL CONDITIONER

Cantata m100 Amplifier

FA-2448 SIX POSITION Filter Wheel

User Guide. Control Box. RoscoLED TM.

Model 7705 Control Module

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

SATA II HDD Canister KISS DA 435 Quick Reference Guide

User's Guide. MiniTec TM Series Model MN25 MultiMeter

PS8 - II. Professional Power Sequencer. User s Manual

PCM-7140 Pulsed Current Source Operation Manual

DeviceNet Expansion Board

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

PIM-Mini Pulsed Current Source Operation Manual

User's Guide. Extech AM A AC Analog Clamp Meter

User s Guide. 600A AC Clamp Meter. Model 38387

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Operation Manual SPS Series

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Model 3526-B Digi-Probe Multimeter

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Mini Digital Multimeter

SC-9

Model 2657A-LIM-3 LO Interconnect Module

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

Two Channel 48 Volt Phantom Power Supply. Artcessories. User's Manual

Model VT120 Fast Timing Preamplifier Operating and Service Manual

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

MPF-1, Mains Power Filter User Manual

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

TB-100 ControLynx Terminal Block

TDM-170 TIMER DISPLAY

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

AirTest Model CN9000 Series Sensor Controller

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

OPERATING INSTRUCTIONS FOR MODEL ST-15 5-DIGIT SPORTS TIMER

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

MFP5G, MFP8G, & MFP12G D-M-E Smart Series Mainframes

ACLD Channel Opto-isolated Digital Input Board

User's Guide. Phase Sequence and Motor Rotation Tester Model

HydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual

PROFIBUS DP Option. for FlexDrive II, Flex+Drive II and MintDrive II. Reference Manual 10/02 MN1911

Automated Tuner System Power Distribution Hub

User's Guide. Model High Precision Quad Output DC Power Supply

TDM-150 TIMER DISPLAY

Digital Lighting Systems, Inc.

ANC Series RS-422 Serial Communications Adapter

User s Guide. POWERVAR Single Phase Power Conditioners

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

RGBW Mini Moving Head Stage Spot Light Model: SSL1. User Manual.

NAS LCP CONTROLLER WITH PANEL FACEPLATE

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1

Three Channel XLR Balanced Patch Bay. Artcessories. User's Manual

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Install Motor Controller User Manual

MAXIMA+ Series Rotary Level Indicator

Owner s Instruction Manual

2260B-RMK-Series Rack Mount Kit

WS115 BREAKOUT ADAPTER USER MANUAL

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

UPS READY POWER DISTRIBUTION ASSEMBLY

1-36V, 0-3A DC Power Supply

MAXIMA + Series ROTARY LEVEL CONTROL

Card Nest Universal 12 position card nest for all K-AB cards above and all other K-AB cards.

Dual Channel Active Direct Box. Artcessories. User's Manual

PCLD-8751 PCLD User Manual

OP8/16 Optoisolated Digital Input Board User's Manual

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

AMT-12 AMT-15. Professional Loudspeakers. Installation and Use Manual

INSTRUCTION MANUAL CM-60. Monitor. Ultra Stereo Labs, Inc. 181 Bonetti Drive San Luis Obispo, CA Telephone

USER MANUAL MODEL 505M-CHC. Surge Protected DB-25 to RJ-45 Modular Adapter

HV-CS kv Edge Mount Triaxial Jack

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

Power Quality Recorder

Master Pulse Reference/ Isolated Pulse Follower Expansion Board

Model 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1

TC100 Precision Thermocouple Calibrator

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

Transcription:

OPERATING AND SERVICE MANUAL Universal Interface Device 45

MAGNA-POWER ELECTRONICS, INC. 81 FULTON STREET, BOONTON, NJ 07005 September 7, 2005

SAFETY NOTICE Universal Interface Device 45 (UID45) connects two or more power supplies for master/slave configurations or for other user configured applications. Before applying power to the system, verify that the system is configured properly for the specific application and that ratings are not exceeded on any input or output terminal. Installation and service must be performed only by properly trained and qualified personnel who are aware of dealing with electrical hazards. Ensure that the ac power line ground is properly connected to the power supply chassis. Furthermore, other power grounds, including those connected to application maintenance equipment, must be grounded for both personnel and equipment safety. Always ensure that facility ac input power is de-energized prior to connecting or disconnecting the input and output power cables. Caution: While the UID45 is a low voltage device, lethal voltages may be present inside the connecting power supply even when the ac input voltage is disconnected. Only properly trained and qualified personnel should remove covers and access the inside of the power supply. During normal operation, the operator does not have access to hazardous voltages within the cabinet. Depending on the user s application, high voltages hazardous to human safety may be generated normally on the output terminals of the connecting power supply. Ensure that the output power cables are properly labeled as to the safety hazards and that any inadvertent contact with hazardous voltages is eliminated. The connecting power supply is designed to be permanently connected to the power source requiring a readily accessible disconnect device incorporated in the fixed wiring. These operating instructions form an integral part of the equipment and must be available to the operating personnel at all times. All the safety instructions and advice notes are to be followed. Neither Magna-Power Electronics, Inc. nor any of the associated sales organizations can accept responsibility for personal injury, consequential injury, loss, or damage that results from improper use of the equipment and accessories. i

LIMITED WARRANTY The following is made in lieu of all warranties expressed or implied. Magna-Power Electronics, Inc. warranties its products to be free of manufacturing defects for a period of one (1) year from date of original shipment from its factory. Magna-Power Electronics, Inc. will repair or replace at its discretion, any part exclusive of labor to diagnose, remove and install, which upon examination by Magna-Power Electronics, Inc., is determined to be defective in material or workmanship, providing such claimed defective material is returned upon written authorization of Magna-Power Electronics, Inc., freight prepaid. All warranty items are F.O.B. factory. All electrical, commercial supply parts and items not manufactured by Magna-Power Electronics, Inc. shall carry the warranty of the original manufacturer and no more, but under no circumstances to exceed the "limited warranty." Replacement parts shall be warranted for a period of 90 days. Warranty labor shall only apply if the machine, assembly, or part is returned to the factory freight prepaid and insured. Magna-Power Electronics, Inc. assumes no responsibility for losses of material, labor, production time, any injury, loss or damage, direct or consequential resulting from the operation of, or use, or the inability to use the product other than specifically covered in this warranty. Damage or breakage through misuse or while in transit is not covered by this warranty. All claims against the warranty shall be the final determination of Magna-Power Electronics, Inc. CLAIM FOR DAMAGE IN SHIPMENT This instrument received comprehensive mechanical and electrical inspections before shipment. Immediately upon receipt from the carrier, and before operation, this instrument should be inspected visually for damage caused in shipment. If such inspection reveals internal or external damage in any way, a claim should be filed with the carrier. A full report of the damage should be obtained by the claim agent and this report should be forwarded to us. We will then advise you of the disposition to be made of the equipment and arrange for repair or replacement. When referring to this equipment, always include the model and serial numbers. ii

RETURNING EQUIPMENT Before returning any equipment to the factory, the following steps should be taken: 1. Contact our technical service department. Give a full description of the difficulty and include the model and serial number of the unit. On receipt of this information, we will give you service information or shipping instructions. 2. Equipment returned to us must be properly packed and insured if the unit is to be returned for service. You must request a "Return Authorization Number." No returns will be accepted without a preauthorized RA. 3. For non-warranty repairs, we will submit a cost estimate for your approval before proceeding. iii

TABLE OF CONTENTS Section Title Page 1.0 GENERAL INFORMATION 1 1.1 Description 1 1.2 Features 1 1.3 IEC Symbols Used in Manual 1 1.4 Power Requirements 1 1.5 Specifications 1 2.0 INSTALLATION AND OPERATION 4 2.1 General 4 2.2 Master/Slave Parallel Operation 4 2.3 Master/Slave Series Operation 8 2.4 Custom Configurations 9 iv

1.0 GENERAL INFORMATION 1.1 Description This manual contains operation and maintenance instructions for Magna-Power Electronics' Universal Interface Device 45 (UID45). The UID45 allows users to connect power supplies for master/slave parallel or series operation or allows connections to external control circuitry with easy access screw terminals. 1.2 Features The UID45 is a general purpose device for connection to Magna-Power Electronics PQA, PQD, SQA, SQD, MQA, MQD, MTA, MTD Series power supplies. The device contains the necessary circuitry for configuring power supplies for master/slave parallel or series operation. Master/slave parallel operation allows two or more power supplies to equally share output current when connected together. Master/slave series operation allows two or more power supplies to equally share output voltage when connected together. The UID45 can be used as an interface for connecting control and monitoring lines to external circuitry. It also contains an area on the printed circuit board for interconnecting wires and placing components for specific user applications. 1.3 IEC Symbols Used in Manual The following IEC symbols are used in this manual. Caution, risk of electric shock Caution, risk of danger Protective conductor terminal Three-phase alternating current 1.4 Power Requirements None 1.5 Specifications 1

The following specifications describe the published operational characteristics of the UID45. UID45 connectors, see figure 1.1 for details: JR1,2,3: 37 pin D-subminature, female JR4: 10 pin plug connector Size: 1.210"H x 7.140"W x 4.010"D, see figure 1.2 for details. Weight: 6.54 oz. Figure 1.1 UID45 connectors (a) JR1,2,3 and ( b) JS4 (viewed from UID45) 2

Figure 1.2 UID45 Enclosure 3

2.0 INSTALLATION AND OPERATION 2.1 General The UID45 is a general purpose device for connection between Magna-Power Electronics PQA, PQD, SQA, SQD, MQA, MQD, MTA, MTD Series power supplies and user devices. Figure 2.1 shows the electrical circuit of the UID45 and figure 2.2 shows jumpers connections for master/slave parallel and series operation. The following sections describe how to use the device for master/slave parallel and series operation and for custom applications. Caution: As shipped, the UID45 is configured for master/slave parallel operation. 2.2 Master/Slave Parallel Operation Two or more Magna-Power Electronics power supplies can be connected in parallel to obtain a total output current greater than that available from one power supply. The total output current is the sum of the output currents of the individual power supplies. Each power supply can be turned on or off separately. Master/slave parallel operation permits equal current sharing under all load conditions and allows complete control of output current from one master power supply. To configure the power supplies for master/slave parallel operation, disconnect power to the power supplies and connect all units and loads in parallel as shown in Figure 2.3. Remove the cover of the UID45 and set the jumpers settings according to Figure 2.2 for master/slave parallel configuration. This is the factory default setting. Replace the cover and connect a 37-conductor male to male cable from connector JS1 of the master power supply to connector JR2 of the UID45. Connect a second 37-conductor male to male cable from connector JS1 of the slave power supply to connector JR1 of the UID45. The jumper settings perform the following functions: 1. The current monitoring voltage, IO2, on the master power supply connects to the external current set point input on the slave power supply. This makes the slave power supply operate at the same current output as the master power supply 2. The power output digital control line of the master power supply connects to the start digital control line of the slave power supply. This connection causes the slave unit to turn on when the master unit is turned on. 4

Figure 2.1 Schematic of UID45 5

Figure 2.2 Jumper JP1 settings for (a) master/slave parallel and (b) master/slave series 3. The standby/alm digital control line of the master power supply connects to the stop digital control line of the slave power supply. This connection causes the slave unit to turn off when the master unit is turned off or a diagnostic condition appears. 4. Resistor R3 and R4 connections set the voltage set point of the slave unit to approximately 2% above the voltage set point of the master unit. This ensures that the slave unit will operate as a current source with an output voltage not to exceed 2% that of the master unit under any steady state or transient condition. 5. Resistor R1 and R2 connections set over voltage trip and over current trip to set points just beyond full scale values. This forces the slave power supply to operate simply as a current source whose current set point is established by the master unit. The slave power supply must be configured for external program input. The master unit can be configured for rotary, keypad, external program, or remote input. Refer to the power supply manual for setting the configuration commands. Three or more parallel connected power supplies can be interconnected by applying additional UID45 units; one UID45 is required for every slave power supply. As illustrated in figure 2.3 for two slave power supplies, follow the previous instructions plus connect an additional 37-conductor male to male cable from JS1 of the second slave power supply to JR1 of the second UID45. Connect a 37- conductor male to male cable between connector JR3 and JR2 of the two UID45 units. Interconnecting UID45 units routes master control and monitoring signals to all of the slave power supplies. 6

Figure 2.3 Master/slave parallel connection for (a) one or (b) more slave power supplies Figure 2.4 Master/slave series connection for (a) one or (b) more slave power supplies 7

2.3 Master/Slave Series Operation Two or more power supplies can be connected in series to obtain a total output voltage greater than that available from one power supply. The total output voltage is the sum of the output voltage of the individual power supplies. Each power supply can be turned on or off separately. Caution: No plus or minus voltage should exceed 800 V with respect to ground for PQA, PQD, SQA, SQD, MQA, MQD Series power supplies; 1000 V with respect to ground for MTA and MTD low/medium voltage models; and 3000 V with respect to ground for MTA and MTD high voltage models. Master/slave series operation permits equal voltage sharing under all load conditions and allows complete control of output voltage from one master power supply. To configure the power supplies for master/slave series operation, disconnect power to the power supplies and connect all units and loads in series as shown in Figure 2.4. Remove the cover of the UID45 and set the jumpers settings according to Figure 2.2 for master/slave series configuration. Replace the cover and connect a 37-conductor male to male cable from connector JS1 of the master power supply to connector JR2 of the UID45. Connect a second 37-conductor male to male cable from connector JS1 of the slave power supply to connector JR1 of the UID45. The jumper settings perform the following functions: 1. The voltage monitoring voltage, VO2, on the master power supply connects to the external voltage set point input on the slave power supply. This makes the slave power supply operate at the same voltage output as the master power supply 2. The power output digital control line of the master power supply connects to the start digital control line of the slave power supply. This connection causes the slave unit to turn on when the master unit is turned on. 3. The standby/alm digital control line of the master power supply connects to the stop digital control line of the slave power supply. This connection causes the slave unit to turn off when the master unit is turned off or a diagnostic condition appears. 4. Resistor R3 and R4 connections set the current set point of the slave unit to approximately 2% above the current set point of the master unit. This ensures that the slave unit will operate as a voltage source with an output current not to exceed 2% that of the master under any steady state or transient condition. 5. Resistor R1 and R2 connections set over voltage trip and over current trip to set points just beyond full scale values. This forces the slave power supply to operate simply as a voltage source whose voltage set point is established by the master unit. The slave power supply must be configured for external program input. The master unit can be 8

configured for rotary, keypad, external program, or remote input. Refer to the power supply manual for setting the configuration commands. Three or more series connected power supplies can be interconnected by applying additional UID45 units; one UID45 is required for every slave power supply. As illustrated in figure 2.4 for two slave power supplies, follow the previous instructions plus connect an additional 37-conductor male to male cable from JS1 of the second slave power supply to JR1 of the second UID45. Connect a 37- conductor male to male cable between connector JR3 and JR2 of the two UID45 units. Interconnecting UID45 units routes master control and monitoring signals to all of the slave power supplies. 2.4 Custom Configurations The UID45 permits users to design and implement their own control circuitry to control or monitor the power supply s inputs or outputs. As shown in figure 2.5, the UID45 has a general purpose area on its printed circuit board to configure custom circuitry or to provide interconnections to utilize connector JR4. Table 2.1 shows the interface of master and slave connectors JR1 through JR3 with corresponding pad areas of JX1 and JX2. Connectors JR2 and JR3 are interconnected to allow daisy chain connections for multiple UID45 units. JR4 is a 10 terminal connector that mates to a screw terminal plug. This connector is user defined and can be utilized to externally monitor or control power supply functions. Table 2.2 shows the interface of connector JR4 and the corresponding pad area. For example, connecting a wire from terminal 1 of JX3 (USER1) to terminal 15 of JX1 provides a signal to indicate the master power supply is operational. The multipurpose area in the center of the PCB enables the user to add circuitry within the UID45. The multipurpose area provides sufficient space to add components like or ing diodes for simultaneously monitoring two diagnostic signals. One example is to connect the anodes of two diodes to the OCT and OVT alarm signal and interconnect the cathodes. This provides a diagnostic signal on either the OCT or OVT alarm signal. 9

Table 2.1 JR1 JR2 JR3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 JX1 JX2 CONNECTION INTERFACE DESCRIPTION FOR JR1, JR2, AND JR3 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 Description REF GND REF GND VREF EXT TVREF EXT VO2 REF CAL GND POWER THERMAL INTERLOCK CUR CTL STANDBY/ALM ALM EXT CTL FUSE RESERVE START CLEAR STOP JR1 JR2 JR3 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 JX1 JX2 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Description REF GND REF IREF EXT TIREF EXT IO2 VMOD +5 PGM LINE STANDBY PHASE LOSS VOLT CTL RESERVE OCT INT CTL OVT RESERVE ARM INTERLOCK SET Table 2.2 CONNECTION INTERFACE DESCRIPTION FOR JR4 JR4 JX3 Description 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 USER1 USER2 USER3 USER4 USER5 USER6 USER7 USER8 USER9 USER10 10

Figure 2.5 Printed circuit board layout of the UID45 11