PGR-3200 MANUAL INSULATION MONITOR

Similar documents
PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

PGR-2601 MANUAL DC GROUND-FAULT RELAY

SE-701 MANUAL GROUND-FAULT MONITOR

SE-703 MANUAL EARTH-LEAKAGE MONITOR

SE-601 MANUAL DC GROUND-FAULT MONITOR

SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

PGM-8134 MANUAL GROUND CONTINUITY MONITOR

SB6100 MANUAL INDUSTRIAL SHOCK-BLOCK

PGM-8325 MANUAL NEUTRAL GROUNDING MONITOR

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

EL731 PROFIBUS INTERFACE

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

02/11/2015

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RM35TF V AC

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

Digital ac/dc (24V) Input Module

Zelio Control-modular measurement and control relays 1

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

SR2B201FU compact smart relay Zelio Logic - 20 I O V AC - clock - display

PRODUCT SPECIFICATION. PC Board Relays. Series.

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

RM17UB3. Price* : USD

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

SE-134C MANUAL GROUND-FAULT GROUND-CHECK MONITOR

XPSMCMDO Digital output pairs expansion modules with screw term

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

XPSMCMDI Input expansion module with screw term

TM3AI4 module TM3-4 analog inputs

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

TM3TI8T module TM3-8 inputs temperature

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

02/11/2015

ETD-BL-1T-OFF-CC- 10S

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

SR2B121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - display

SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

CompactBlock Guard I/O EtherNet/IP Safety Modules

TM3TI4 module TM3-4 inputs temperature

SR2A201FU compact smart relay Zelio Logic - 20 I O V AC - no clock - display

SR2A201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display

XPSMCMMX inputs 2 output pairs expansion module with screw term

SR2B121FU. Price* : USD with ladder programming. 80 maat 100 V (without extension)

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

PHOENIX CONTACT Features

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

SE-330 MANUAL NEUTRAL-GROUNDING-RESISTOR MONITOR

T M. IRDH375 Series. Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems. Technical Bulletin NAE / 09.

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

E1 Plus Electronic Overload Relay

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

RM35LM33MW liquid level control relay RM35-L V AC/DC

TM3TM3 module TM3-2 temperature inputs and 1 analog output

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Contact protection relay

EL731 DEVICENET INTERFACE

MODELS DPDT DPDT DPDT-60MS DPDT-60MS

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

RM4JA01F current measurement relay RM4-J - range ma V AC

Signal Doublers. VariTrans A 20300

em4 Accessories Digital expansions

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

24/48/120 VAC Interface Card Instruction Manual

ZBRN1. Main. Device short name

Ultra Slim Relays 24

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

Digital ac/dc (24V) Input Module

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

1492-SP Supplementary Protectors

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW

Electronic timer CT-ERD.12

TM3DI16 module TM3-16 inputs

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Measuring and Monitoring Relays

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

Transcription:

Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-3200 MANUAL INSULATION MONITOR REVISION 3-E-040918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document Number: PM-1025-EN Printed in Canada

PGR-3200 Insulation Monitor Page i This page intentionally left blank.

PGR-3200 Insulation Monitor Page ii SECTION TABLE OF CONTENTS PAGE 1 General... 1 2 Operation... 1 2.1 Relay Operating Mode... 1 2.2 Front-Panel Controls... 1 2.2.1 Reset... 1 2.2.2 Test... 1 2.3 Front-Panel Indication... 1 2.3.1 Power... 1 2.3.2 Insulation Warning... 1 2.3.3 Active... 1 2.3.4 Insulation Alarm... 1 2.4 Analog Output... 1 2.5 Remote Reset... 1 2.6 Remote Test... 1 3 Installation... 3 3.1 PGH-5000 and PGH-6000... 4 4 Technical Specifications... 6 4.1 PGR-3200... 6 4.2 PGH High-Tension Couplers... 7 5 Ordering Information... 7 6 Performance Test... 7 6.1 Insulation Test... 7 Appendix A PGR-3200 Revision History... 8 FIGURE LIST OF FIGURES PAGE 1 PGR-3200 Outline and Mounting Details... 2 2 Connection Diagram for Ungrounded Systems Under 1.3 kv... 3 3 Connection Diagram for Ungrounded 5-kV Systems... 3 4 PGH-5000 Outline and Mounting Details... 4 5 PGH-6000 Outline and Mounting Details... 5 6 PGA-0510 Analog Ohm Meter... 5 DISCLAIMER Specifications are subject to change without notice. Littelfuse, Inc. is not liable for contingent or consequential damages, or for expenses sustained as a result of incorrect application, incorrect adjustment, or a malfunction.

PGR-3200 Insulation Monitor Page iii This page intentionally left blank.

PGR-3200 Insulation Monitor Page 1 1. GENERAL The PGR-3200 Insulation Monitor measures phase-toground resistance to detect electrical-insulation failure in an ungrounded power utilization system. It provides three levels of detection with a 50-k warning with an LED and output contact indication, a 30-k warning with LED indication, and a 10-k alarm with LED and output contact indication. An analog output is provided for predictive maintenance trending. The PGR-3200 can be used to detect faults in ungrounded systems up to 6 kv. It can be directly connected to a system up to 1.3 kv, single or three phase, 50 or 60 Hz. A PGH-series high-tension coupler is required for 5- and 6-kV systems. 2. OPERATION The PGR-3200 actively monitors insulation resistance when it is connected to the supply voltage. All conductors connected to the monitored circuit are included in the insulation measurement. See Fig. 2. 2.1 RELAY OPERATING MODE The PGR-3200 output relays operate in the non-fail-safe mode; they energize when an insulation warning or alarm occurs. 2.3.4 INSULATION ALARM When insulation resistance measures 10 k or less, the red LED labelled <10 k will light. 2.4 ANALOG OUTPUT A non-isolated, 0- to 1-mA output (terminals 25 and 26) indicates insulation resistance. The metering output relates to an insulation-resistance range of 0 to infinity using optional meter PGA-0510. See Figs. 2, 3, and 6. 2.5 REMOTE RESET When remote-reset terminals 18 and 19 (alarm) or 21 and 22 (warning) are connected, a warning or alarm remains latched until the RESET switch is pressed or the remote-reset terminals are momentarily opened. If the remote-reset terminals are not connected, the PGR-3200 operates in non-latching mode; a warning or alarm will reset when the fault is removed. 2.6 REMOTE TEST When terminal 29 is connected to ground the monitor will alarm. See Figs. 2 and 3. Response to a test input can take several seconds. 2.2 FRONT-PANEL CONTROLS 2.2.1 RESET The front-panel RESET switch is used to reset latching trips. Cycling the supply voltage will also reset the PGR- 3200. See Section 2.5. 2.2.2 TEST All LED s will light and output relays will energize when the TEST button is pressed for at least 8 s. 2.3 FRONT-PANEL INDICATION 2.3.1 POWER The green LED s labelled PWR indicates presence of supply voltage. 2.3.2 INSULATION WARNING The red LED s labelled 50 k and 30 k will light when those respective insulation resistance values, or lower are measured. 2.3.3 ACTIVE The red LED labelled ACTIVE indicates the monitor is enabled.

FIGURE 1. PGR-3200 Outline and Mounting Details. PGR-3200 Insulation Monitor Page 2

PGR-3200 Insulation Monitor Page 3 3. INSTALLATION NOTE: Mounting, terminal-block connections, and wiring must conform to applicable local electrical codes. Check all applicable codes prior to installation. The PGR-3200 can be surface or DIN-rail mounted. See Fig. 1. Use terminal 6 (L1) as the line terminal and terminal 5 (L2/N) as the neutral terminal. Connect terminal 30 to ground. For systems up to 1.3 kv, connect terminal 2 to one phase on the load side of the starter. Connect terminals for latching operation, remote reset, and remote test as required. See Sections 2.5 and 2.6 and Figs. 2 and 3. Connect an optional PGA-0510 Analog Ohm Meter to terminals 25 and 26. Meter outline, dimensions, and cutout size are shown in Fig. 6. FIGURE 3. Connection Diagram for Ungrounded 5-kV Systems. FIGURE 2. Connection Diagram for Ungrounded Systems Under 1.3 kv.

PGR-3200 Insulation Monitor Page 4 FIGURE 4. PGH-5000 Outline and Mounting Details. 3.1 PGH-5000 AND PGH-6000 For 5-kV and 6-kV systems, connect the PGR-3200 to the monitored circuit with a PGH-5000 and PGH-6000 respectively. See Fig. 4 for PGH-5000 outline and mounting details. See Fig. 5 for PGH-6000 outline and mounting details. Connect protective-ground terminal ( ) to ground. Connect terminal E to ground or to PGR-3200 terminal 30, which must be grounded. Connect terminal M to PGR- 3200 terminal 29. (PGR-3200 terminal 2 is not used.) For PGR-3200 to PGH-5000/PGH-6000 distances greater than 10 m (30 ), use shielded cable, and connect the cable shield to the second PGH-5000/PGH-6000 terminal E. Connect terminal A to one phase on the load side of the motor starter. See Fig. 3. The PGH-5000/PHG-6000 includes 915 mm (36 ) of highvoltage conductor.

PGR-3200 Insulation Monitor Page 5 FIGURE 5. PGH-6000 Outline and Mounting Details. FIGURE 6. PGA-0510 Analog Ohm Meter.

PGR-3200 Insulation Monitor Page 6 4. TECHNICAL SPECIFICATIONS 4.1 PGR-3200 Supply 120 V option... 5 VA, 120 Vac, 24 Vac (+10, -15%) 50/60 Hz 240 V option... 5 VA, 240 Vac, (+10, -15%) 50/60 Hz Maximum System Voltage: Direct Connection: UL Rating... 600 Vac Maximum... 1,300 Vac With PGH-5000... 5,000 Vac With PGH-6000... 6,000 Vac Measuring Voltage... 12 Vdc Measuring Current... 20 A maximum DC Resistance... 600 k AC impedance at 50-60 Hz... > 1 M Frequency Range... 50 20,000 Hz Response-Level Settings... 10, 30, and 50 k (fixed) Response Delay: Warning, 10 k relay output: Insulation Resistance < 5 k... 4 s Insulation Resistance = 10 k... 5 s Alarm, 50 k relay output: Insulation Resistance < 25 k... 2.5 s Insulation Resistance = 50 k... 4.5 s Analog Output: Mode... Self Powered Range... 0 to 1 ma Impedance... 6 k maximum Parameter... 0 to Ω Insulation Resistance Output Relays; Warning and Alarm: Configuration... N.O. and N.C. (Form C) Operating Mode... Non-Fail-Safe UL Contact Rating... 5 A, 240 Vac resistive, 0.28 A, 30 Vdc resistive Switching Capacity... 1,200 VA Supplemental Contact Ratings: Carry Continuous... 5 A, maximum Test... Front-Panel Button and Remote N.O. Contact Terminals... Wire Clamping, 22 to 12 AWG (0.3 to 3.3 mm 2 ) conductors Tightening Torque... 0.40 N m (3.54 lbf in) Conductor Type... Copper, Solid or Stranded with Ferrules Conductor Rating... 60/75 C Dimensions: Height... 75 mm (3.0 ) Width... 100 mm (3.9 ) Depth... 113 mm (4.4 ) Including DIN rail... 115 mm (4.5 ) Shipping Weight...0.45 kg (1 lb) Environment: Operating Temperature... -10 to 60 C (14 to 140 F) Storage Temperature... -40 to 80 C (-40 to 176 F) Humidity... 85% Non-Condensing Enclosure Rating... lp20 Altitude... 2,000 m (6,562 ft) maximum Overvoltage Category... II Pollution Degree... 2 Certification... UL Listed UL508 Industrial Control Equipment FCC RoHS Trip Mode Latching or Autoreset Reset... Front-Panel Button and Remote N.C. Contacts

PGR-3200 Insulation Monitor Page 7 4.2 PGH HIGH-TENSION COUPLERS Maximum Line Voltage: PGH-5000... 5,000 Vac PGH-6000...6,000 Vac Current to Ground...2.5 ma maximum Terminal M Maximum Voltage...50 Vac Terminals: E, E, and M...Wire Clamping, 26 to 12 AWG (0.13 to 3.3 mm 2 ) conductors Tightening Torque...0.50 N m (4.43 lbf in) 6. PERFORMANCE TEST 6.1 INSULATION TEST Perform this test with the starter open and appropriate lock-out procedures. Connect a 20 k resistor between one phase and ground at the line side of the starter or motor terminal box. Select a phase that is not connected to PGR-3200 terminal 2 (or the PGH-5000 or PGH-6000). The PGR-3200 will indicate a warning by lighting the 50 k and 30 k LED s and energizing the 50 k insulation relay. Replace the 20-k resistor with an 8 k resistor. The PGR-3200 will indicate an alarm by lighting the < 10 k LED and energizing the 10 k insulation relay....wire Clamping, 10 AWG (5.3 mm 2 ) maximum High Tension Lead A...8 AWG (8.4 mm 2 ), 40 kvdc, 915 mm (36 ) 5. ORDERING INFORMATION PGA-0510... Analog Ohm Meter PGH-5000... 5 kv High Tension Coupler PGH-6000... 6 kv High Tension Coupler NOTES: (1) UL not available for this supply option.

PGR-3200 Insulation Monitor Page 8 MANUAL RELEASE DATE April 9, 2018 November 19, 2015 August 4, 2015 APPENDIX A PGR-3200 REVISION HISTORY MANUAL REVISION 3-E-040918 3-D-111915 3-C-080415 PRODUCT REVISION (REVISION NUMBER ON PRODUCT LABEL) 01 MANUAL REVISION HISTORY REVISION 3-E-040918 SECTION 4 Specifications added. REVISION 3-D-111915 SECTION 4 Terminal torque specifications added. REVISION 3-D-111915 SECTION 4 Terminal torque specifications added. SECTION 5 Ordering information updated. REVISION 3-C-080415 Model name changed to Insulation Monitor. SECTION 3 Figs. 4, 5, and 6 updated. SECTION 4 Output relay, dimension, and environment specifications updated. Certifications updated. Section 4.2 added. SECTION 5 Ordering information updated. APPENDIX A Revision history added. PRODUCT REVISION HISTORY PRODUCT REVISION 01 UL Certification.