Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Similar documents
Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Liebert. AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability CERTIFIED HVAC-HYGIENE.

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers

Liebert PDX from 15 to 120 kw

Liebert PDX from 15 to 120 kw

Liebert PDX. The Cooling Solution for Small and Medium Data Centers. Digital Scroll. Part Load. Competent Partner Efficiency

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

Liebert. PDX from 15 to 165 kw. Direct Expansion Solution for Small and Medium Data Centers

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa

Liebert HPC Freecooling Chiller

Liebert. EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

Liebert. PCW from 25 to 220 kw. Chilled Water Units Optimizing Data Center Efficiency

Liebert. DCL up to 35 kw. Modular Rack Cooling

Liebert PCW. Cool the Cloud

Precision Cooling for Business-Critical Continuity. Liebert HPC-M. The Data Center FreeCooling Chiller with the Lowest Impact on the Environment

Liebert. DCL up to 35 kw. Modular Rack Cooling

Liebert HPM from 4 kw to 100 kw

Precision Cooling for Business-Critical Continuity. Liebert CRV. Efficient Cooling For IT Equipment NEW. Extended Range Available From 10 To 50 kw

Five Best Practices for Increasing Efficiency, Availability and Capacity: The Enterprise Data Center Design Guide

Emerson Network Power Technology and Solutions for a World in Action

SUPERSAVER. Energy Efficiency Optimization Software for Freecooling Systems

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

Liebert NXC from 10 to 200 kva

Liebert DSE Precision Cooling System Industry-best efficiency. Increased capacity. Ensured availability. EFFICIENCY. CAPACITY. AVAILABILITY.

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

SmartAisle Intelligent, Integrated Infrastructure Using Row-based Building Blocks. Solutions For Business-Critical Continuity

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

Liebert HPC. Data Center Freecooling Chiller with 100% Compressor Back Up

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Liebert. HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers

Liebert : The Right Cooling For IT Environments

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

Trinergy from 200 to 1600 kw. High Power Modular Scalable UPS With Three Dynamic Functioning Modes

Liebert. CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

SmartRow Intelligent, Integrated Infrastructure in a Self-Contained Line-Up. Solutions For Business-Critical Continuity

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

SmartMod Intelligent, Integrated Infrastructure for the Data Center

VERTIV SERVICE CAPABILITY

Liebert. DSE Thermal Management System Free Cooling Economization Without Using Water

Solutions for Business-Critical Continuity. Emerson Network Power Technology and Solutions for a World in Action

Liebert NX from 30 to 60 kw. AC Power for Business-Critical Continuity

Managed Rack PDU MPH2 More efficient Simpler Better

Liebert 80-eXL from 160 to 500 kw. Enhanced Design and Improved Efficiency

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Smart Solutions Intelligent, Integrated Infrastructure for the Data Center

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Total Modular Data Centre Solutions

Chloride CROSS Rack 16 A, 32 A and 63 A

DATA CENTER PRECISION COOLING: The Need For A Higher Level Of Service Expertise

Liebert DCW CATALOGUE

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Rack cooling solutions for high density racks management, from 10 to 75 kw

Liebert DM. High Performance, Sensible Cooling for Small Computer Rooms and Network Closets

SMARTAISLE Intelligent, Integrated Infrastructure for the Data Center

Liebert APM UPS The Industry s Highest Energy Efficiency In A Row-Based, On-line UPS. AC Power For Business-Critical Continuity

INNOVATE DESIGN APPLY.

IT Air Conditioning Units

INNOVATE DESIGN APPLY.

Precision Cooling. Precision Cooling Advantages

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

Data Center Optimized Controls

CTC Low Temperature Process Chillers

2017 EMEA Data Centre Cooling Solution Product Leadership Award

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Liebert 80-eXL from 100 to 1200 kw. Enhanced Design and Improved Efficiency

Liebert exm UPS kva/kw Efficient, Flexible Power Optimized for Midsize Applications FLEXIBLE. ECONOMICAL. INTELLIGENT

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Precision Cooling Mission Critical Air Handling Units

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

DATA CENTER AIR HANDLING COOLING SOLUTIONS

Liebert APM. The Compact Row-Based UPS With Flexpower Technology TM. AC Power for Business-Critical Continuity

CGWN/CCUN indoor liquid chillers The compact AquaStream² solution

MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

VERTIV LIFE SERVICES. Remote Diagnostic and Preventive Monitoring

NG DataCenters. Paolo Caturegli Maurizio Davini

Rack & Enclosure Systems

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

Close-coupled cooling

CRITICAL INFRASTRUCTURE ASSESSMENTS

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

Efficiency of Data Center cooling

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

Liebert. PDX and PCW Compact Perimeter Cooling Solutions

Indirect Adiabatic and Evaporative Data Center Cooling

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Liebert MicroPOD 230V

SMARTMOD Intelligent, Integrated Infrastructure for the Data Center

Welcome Association of Energy Engineers to the Microsoft Technology Center

Indirect Adiabatic and Evaporative Data Centre Cooling

Liebert. EXS from 10 to 20 kw. Optimized and integrated three-phase UPS solution with high efficiency power protection

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers

Liebert Load Bus Sync Extender/Adapter for Dual Bus UPS

MSYS 4480 AC Systems Winter 2015

Transcription:

Liebert AFC from 500 to 1450 kw The Adiabatic Freecooling Solution with Top-Tier Availability

Liebert AFC, the Ideal Adiabatic Chilled Water Solution for Top-Tier Data Centers Emerson Network Power delivers innovative solutions through 12 Centers of Expertise, distinct areas of breakthrough products and services that help determine what is needed in relation to the application. Supported by a global network in more than 150 countries, backed by local service and support from more than 2,000 certified professionals, Emerson Network Power is uniquely positioned to provide systems and integrated solutions wherever our customers are located. Emerson Network Power understands the challenges of setting up the right infrastructure to support businesscritical data center operations and helps respond to any demand by providing innovative solutions, allowing customers to concentrate on their business requirements. Liebert AFC combines the outstanding levels of energy efficiency allowed by freecooling together with the endless availability guaranteed by the multi-scroll compressor back up and the highly efficient adiabatic wet pad system. The latter humidifies the air entering the freecooling and condensing coils, consequently increasing freecooling operation and mechanical efficiency. The unit is thus designed to guarantee 100% cooling availability even under the most critical conditions such as fluctuating power supplies, limited water availability and high ambient temperatures. 2

Liebert AFC... Solves IT All! Optimized Water Consumption Ultra Silent two versions available 1.08 Top Energy Efficiency Levels ppue down to 1.08 100% 100% Cooling Availability Even under extreme conditions

Liebert AFC: One Unit, Three Cooling Technologies Energy Efficiency All year round adiabatic freecooling operation and minimized use of compressors deliver the highest efficiency, unreachable by a competitor's traditional freecooling chiller. Freecooling Integrated freecooling modules deliver the cooling load required by the data center without the need of compressors. Partial Load Pure adiabatic freecooling manages 50% load up to 20 C ambient temperature. NEW icom Touch Display 7 The icom Control ensures the intelligent management of units within the dynamic data center environment, while the innovative 7 touch screen display presents advanced graphic functions. Supersaver The Supersaver is the software logic embedded in the icom Control leveraging on the communication with floor mount units to maximize efficiency at system level. 4

Adiabatic Cooling Highly efficient adiabatic wet pads humidify air entering the freecooling and condensing coils, thus increasing freecooling operation and mechanical efficiency. Fast Start Ramp Fast recovery capacity: the unit ensures the reestablishment of the full cooling capacity in 70 seconds, following a power restart. The control remains operative without the need of an external single phase power supply. Ultra Silent New generation super silent EC fans combined with the sound barrier provided by the adiabatic pads ensure an extremely silent operation. Electronic Expansion Valve Minimized condensing pressure reduces power consumption, thus achieving high efficiency levels. Back-Up 100% Compressor back up Microchannel Condensing Coil Multiple scroll compressors ensure 100% cooling back up, up to 50 C ambient temperature also in the case of a water shortage. The full aluminum coil ensures extreme efficiency levels during the mechanical cooling mode and minimizes the refrigerant charge. 5

Data Centers are Heading for New Energy Efficiency Standards, Achievable with Adiabatic Freecooling Recent market trends have seen an increase in operating temperatures under which new IT equipment operates. This has led to the progress in adiabatic solutions, extending freecooling availability to higher ambient temperatures. Data center designs, in accordance with ASHRAE* guidelines, have accepted to move out of the recommended envelop to the allowable ranges (A1-A4). With the introduction of the Liebert AFC adiabatic freecooling chiller, Emerson Network Power meets customer needs, offering a highly efficient solution which maximizes freecooling availability in warmer climates, for longer periods of time and guaranteeing continuous availability even under extreme ambient conditions. 100% 90% 80% 70% 60% 50% 40% 30 30% 25 20 20% Absolute Humidity (g/kg) in the Data Center 15 10 5 2004 ASHRAE Recommended 2011 ASHRAE Recommended A1 A2 A3 A4 10% -10-5 0 5 10 15 20 25 30 35 40 45 50 55 Temperature ( C) in the Data Center * The American Society of Heating, Refrigerating and Air Conditioning Engineers establishing guidelines relating to HVAC systems. 6

100% Cooling Availability Under All Conditions Emerson Network Power Liebert AFC has been designed to ensure maximum availability for data centers. A consolidated design and the integration of new technologies have led to the most reliable adiabatic cooler in the market, which provides 100% cooling also during extreme conditions. 100% cooling in case of water shortages No need of big water storage tanks, no need to worry about water shortages. The compressors back up system does not require the adiabatic system to be active in order to deliver the full cooling capacity. 100% cooling at extreme ambient temperatures Liebert AFC delivers full capacity up to 50 ambient temperature. When the adiabatic system is active, higher temperatures can be reached without affecting the cooling performance. 100% cooling guaranteed in 70 seconds, following a power restart Featuring Fast Start Ramp, Liebert AFC will restore 100% cooling in just 70 seconds, following a power restart and will ensure the unit's immediate activation. The control, moreover, will keep operating without the need of an external single phase power supply. 7

All Year Round Adiabatic Freecooling is the Key to Unparalleled Levels of Energy Efficiency Depending upon ambient temperature and humidity, Liebert AFC constantly optimizes power and water consumption by combining its three embedded technologies: adiabatic, freecooling and mechanical cooling. All operating modes deliver high levels of efficiency, relying on the triple adiabatic effect of: increasing freecooling capacity extending freecooling operation to higher ambient temperatures increasing mechanical cooling efficiency Moreover, especially when operating at optimized levels of water temperature such as 26-20 C, freecooling will be availble up to around 32 C ambient temperature: all year round. Liebert AFC Operating Modes FREECOOLING Only fans are needed to operate: direct exchange between water and air. ADIABATIC FREECOOLING The adiabatic system allows freecooling to operate at higher ambient temperatures. HYBRID COOLING Adiabatic freecooling is the primary cooling source, multiple scroll compressors are used as back up. ADIABATIC MECHANICAL COOLING Compressor s efficiency is increased by the adiabatic system. SAFE MODE 100% availability also during water shortages; the sole mechanical cooling system will guarantee full load. Freecooling Freecooling Adiabatic Freecooling Adiabatic Compressors Adiabatic Compressors Compressors 8

A New Step Ahead in Energy Savings The Ideal Solution for Full and Partial Load Applications Liebert AFC provides a significant increase in terms of energy savings when compared to any competitor's most efficient chilled water system available in the market. The graphs below show the operating modes of Liebert AFC throughout the year and the resulting energy savings compared to a high efficiency freecooling chiller, cooling a 1.4 MW data center located in London. Hours per year (n.) 600 500 400 300 200 100 Freecooling 50% time/year Hybrid 50% time/year 100% load Annual EER = 21 Adiab.Mechanical less than1% time/year 0-10 -5 0 5 10 15 20 25 30 35 Ambient Temperature ( C) Freecooling Chiller Liebert AFC Annual Energy Consumption 759,000 kwh 577,000 kwh 29,000 Energy Cost Saving/Year The advantages of the adiabatic and hybrid designs are even more effective at partial load, where the compressor operation throughout the year is further minimized. 600 50% load Annual EER = 57 Annual Energy Consumption Hours per year (n.) 500 400 300 200 100 Freecooling 90% time/year Hybrid 10% time/year Adiab.Mechanical less than1% time/year Freecooling Chiller Liebert AFC Liebert AFC with Supersaver 281,000 kwh 185,000 kwh 107,000 kwh 0-10 -5 0 5 10 15 20 25 30 35 Ambient Temperature ( C) The above graphs and values refer to an application in London with 30% glycol mixture and inlet-outlet liquid temperatures of 26-20 C. 28,000 Energy Cost Saving/Year 9

The State-of-the-Art icom Control: Precise, User-Friendly Information at Unit Level 7 TOUCH SCREEN GRAPHIC DISPLAY Quick and intuitive. Monitors the historical trend of key parameters: efficiency, adiabatic water usage, cooling capacity and temperatures. Straightforward visualization of diagnostics. Two versions available: installed in the unit or in remote for indoor installations. The icom Control features three key distinguishing characteristics Intelligent Energy & Water Management Monitoring of local temperature and humidity profiles optimizes the unit's operating costs. Advanced Logics to enhance Savings Optimized management of compressors and fans maximizes the hybrid mode usage and efficiency. Unceasing Control Operation Fast restoration capacity: 100% cooling available in 70 seconds. 10

Web Monitoring Third Party Systems Monitoring: Modbus TCP & 485, SNMP, BACnet TCP & MSTP Remote Monitoring, Diagnostic and Preventive Service: Life Centralized Monitoring, Alarms and Control Management: Liebert Nform and Liebert Sitescan Web Perfect Synchronization at Teamwork Level The user friendly control exploits the management of energy and water also at teamwork level. The system collects information from the different units key parameters and operating modes (adiabatic, freecooling and mechanical cooling) while taking into account water and electricity costs. The control predictively calculates and then implements the combination which optimizes operating costs. Utmost Efficiency Even at the Data Center System Level When considering the entire data center scenario, involving indoor and outdoor units, the Supersaver becomes the key driver in terms of delivered efficiency at the data center system level. This software logic, embedded in the control, leverages on the LAN communication between all these units. This is to ensure the perfect coordination of the entire system, thus increasing freecooling operation and consequently leading to superior energy savings. 11

Adiabatic Freecooling Chiller available from 500 kw to 1450 kw Liebert AFC - Adiabatic Freecooling Chiller Standard Ultra Silent Model FA0 046 053 059 073 087 102 117 130 046 LN 053 LN 059 LN 073 LN 087 LN 102 LN 117 LN 130 LN Dry Performance - ambient 35 C, adiabatic OFF Cooling capacity 1 kw 518 573 655 803 948 1133 1288 1451 494 543 630 764 903 1073 1218 1385 Wet Performance - ambient 35 C, relative humidity 45%, adiabatic ON Cooling capacity 1 kw 562 622 708 869 1023 1228 1396 1572 540 594 686 835 981 1175 1335 1516 Sound level SPL 2 db(a) 73.5 73.5 74 74.5 74.5 74.5 75.0 75 67.5 67.5 68 68.5 68.5 68.5 69.0 69 PWL 3 db(a) 94.7 94.7 95.5 96.3 97 97.6 98.1 98.5 88.9 88.9 89.5 90.3 91 91.5 92.0 92.5 Dimensions Length mm 5597 5597 6867 8137 9407 10677 11947 13217 5597 5597 6867 8137 9407 10677 11947 13217 Depth mm 3043 3043 3043 3043 3043 3043 3043 3043 3043 3043 3043 3043 3043 3043 3043 3043 Height mm 2669 2669 2669 2669 2669 2669 2669 2669 2669 2669 2669 2669 2669 2669 2669 2669 1 Performance data calculated at the following conditions: power supply 400V/3ph/50Hz; coolant inlet/outlet temperature 26/20 C; ethylene glycol 30%. 2 Measured at outdoor temperature of 35 C; 1 m from the unit; free field conditions; according to ISO 3744. 3 Measured at outdoor temperature of 35 C; calculated according to ISO 3744. Efficency at Full and Part Load Condition Ambient Temperature Madrid London 100% LOAD 50% LOAD 25% LOAD 35 C 840 65 EER 5.0 Full capacity also in dry mode Starts Freecooling EER 5.5 EER 5.2 25 C 2220 1690 EER 7.3 EER 5.9 EER 5.4 Full Freecooling 15 C 5700 7005 EER 13 EER 23 Full Freecooling EER 81 Full Freecooling 5 C EER values for the FA0 Range at the following conditions: adiabatic function active (wet pads mode) and calculated according to the average humidity data obtained from Central Europe locations. 12

Freecooling Chiller available from 500 kw to 1450 kw Liebert AFC - Freecooling Chiller Standard Ultra Silent Model FD0 046 053 059 073 087 102 117 130 046 LN 053 LN 059 LN 073 LN 087 LN 102 LN 117 LN 130 LN Performance - ambient 35 C Cooling capacity 1 kw 521 577 660 808 957 1141 1296 1463 497 547 636 769 915 1083 1229 1400 Sound level SPL 2 db(a) 74.0 74.0 74.5 75.0 75 75.0 75.5 75.5 68.0 68.0 68.5 69.0 69 69.0 69.5 69.5 PWL 3 db(a) 94.8 94.8 95.5 96.4 97 97.7 98.2 98.5 88.9 88.9 89.5 90.5 91 91.7 92.2 92.5 Dimensions Length mm 5597 5597 6867 8137 9407 10677 11947 13217 5597 5597 6867 8137 9407 10677 11947 13217 Depth mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 Height mm 2630 2630 2630 2630 2630 2630 2630 2630 2630 2630 2630 2630 2630 2630 2630 2630 1 Performance data calculated at the following conditions: power supply 400V/3ph/50Hz; coolant inlet/outlet temperature 26/20 C; ethylene glycol 30%. 2 Measured at outdoor temperature of 35 C; 1 m from the unit; free field conditions; according to ISO 3744. 3 Measured at outdoor temperature of 35 C; calculated according to ISO 3744. Efficency at Full and Part Load Condition Ambient Temperature Madrid London 100% LOAD 50% LOAD 25% LOAD 35 C 840 65 EER 4.1 EER 5.0 EER 4.4 25 C 2220 1690 EER 5.1 Starts Freecooling EER 5.5 EER 5.2 15 C 5700 7005 EER 11 EER 11 Full Freecooling EER 32 Full Freecooling Full Freecooling 5 C EER values for the FD0 Range 13

Emerson Network Power Thermal Management Data Center Infrastructure for Small and Large Applications Liebert HPC Wide range of high efficiency Freecooling Chillers from 40 kw to 1600 kw Designed specifically for data center applications and to work with SmartAisle TM Premium energy efficiency version icom control featured Liebert PDX - Liebert PCW Liebert PDX available from 15-120 kw Liebert PCW available from 30-220 kw Premium energy efficiency Eurovent certified performance Unique control capabilities with the icom Control Liebert EFC Indirect evaporative air freecooling unit icom control featured New generation Liebert EC Fans Eurovent certified heat exchanger Trellis Platform Emerson Network Power s Trellis platform is a real-time infrastructure optimization platform that enables the unified management of data centre IT and facilities infrastructure. The Trellis platform software can manage capacity, track inventory, plan changes, visualize configurations, analyze and calculate energy usage, and optimize cooling and power equipment as well as enable for virtualization. The Trellis platform monitors the data center, providing a thorough understanding of system dependencies to help IT and facilities organizations keep the data center running at peak performance. This unified and complete solution, delivers the power to see the real situation in your data center, make the right decision and take action with confidence. 14

Liebert AFC The Adiabatic Freecooling Chiller available from 500-1450 kw Integrated adiabatic pad system High freecooling capacity 100% compressor back up SmartAisle Aisle containment Provides highest energy efficiency Works with any Liebert cooling unit Service Emerson Network Power supports entire critical infrastructures with the largest global service organization and an extensive service offering, enhancing network availability and ensuring total peace of mind 24/7. Our approach to servicing critical infrastructure covers all aspects of availability and performance: from single power and thermal management equipment to entire mission-critical systems. The most comprehensive insurance for business protection can be obtained with a service program from Emerson Network Power which includes access to LIFE. Liebert CRV Row-based high efficiency cooling units available from 10-50 kw in DX and CW versions Full airflow and cooling capacity modulation to match server load and to save energy Best footprint capacity with the highest efficiency Six different control modes to ensure greater flexibility Liebert XD Refrigerant based high density cooling installed close to the server Hot spot management for up to 30 kw per rack On-demand upgrade with plug and play High efficiency and 100% sensible cooling LIFE TM LIFE provides remote diagnostics and preventive monitoring service for UPS and thermal management equipment. LIFE delivers increased uptime and operational efficiency by enabling continuous monitoring of your equipment, expert data analysis and field engineering expertise. Through the data transferred from your equipment via LIFE, our remote service experts gain the real-time insight and information needed to quickly identify, diagnose, and resolve any irregularities that may arise in operation, ultimately taking responsibility for your critical assets 24/7. 15

Ensuring The High Availability Of Mission-Critical Data And Applications. About Emerson Network Power Emerson Network Power, a business of Emerson (NYSE:EMR), delivers software, hardware and services that maximize availability, capacity and efficiency for data centers, healthcare and industrial facilities. A trusted industry leader in smart infrastructure technologies, Emerson Network Power provides innovative data center infrastructure management solutions that bridge the gap between IT and facility management and deliver efficiency and uncompromised availability regardless of capacity demands. Our solutions are supported globally by local Emerson Network Power service technicians. Learn more about Emerson Network Power products and services at www.emersonnetworkpower.eu Locations Emerson Network Power Global Headquarters 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229, USA Tel: +1 614 8880246 Emerson Network Power Thermal Management EMEA Via Leonardo Da Vinci, 16/18 Zona Industriale Tognana 35028 Piove di Sacco (PD) Italy Tel: +39 049 9719 111 Fax: +39 049 5841 257 ThermalManagement.NetworkPower.Eu@Emerson.com Emerson Network Power United Kingdom George CurlWay Southampton SO18 2 RY, UK Tel: +44 (0)23 8061 0311 Fax: +44 (0)23 8061 0852 While every precaution has been taken to ensure accuracy and completeness herein, Emerson assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice. MKA4L0UKAFC Rev.3-11/2014 Globe Park Fourth Avenue Marlow Bucks SL7 1YG Tel: +44 1628403200 Fax: +44 1628403203 Uk.Enquiries@Emerson.com EmersonNetworkPower.eu Follow us on Social Media: Emerson. Consider it Solved., Liebert, SmartAisle TM, Trellis TM, Life TM and Emerson Network Power are trademarks of Emerson Electric Co. or one of its affiliated companies. 2014 Emerson Electric Co.