Xxxxx Xxxxxx OM-CP-QUADVOLT. OM-CP-OCTVOLT 8-Channel Low Level DC Voltage Data Logger. 4-Channel Low Level DC Voltage Data Logger INSTRUCTION SHEET

Similar documents
Xxxxx Xxxxxx Bridge / Strain Gauge Data Logger

Xxxxx Xxxxxx DC Voltage Data Logger

User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

High Temperature Data Logger

User s Guide. OM-CP-HITEMP140-M12 High Temperature Data Logger with an M12 Probe Connector

User s Guide. OM-CP-HITEMP140X2 High Temperature Dual Probe Data Logger Series

User s Guide. OM-CP-SMR101A-KIT Soil Moisture Data Logger

User s Guide RDXL6SD-USB. Temperature Data Logger with USB. Shop online at omega.com

User s Guide TXDIN1700. Universal DIN Rail. Shop online at omega.com SM. For latest product manuals:

FMA-7400/7500 Series Configurator

User s Guide. Series. Communication Manual. Shop online at omega.com SM. For latest product manuals:

User s Guide OM-SGD-28-M. Shop online at omega.com. Smart Graphics Display. For latest product manuals:

User s Guide TSD600. Shop online at omega.com SM. For latest product manuals: omegamanual.info

Xxxxx Xxxxxx OM-CP-TEMP1000IS-A. Intrinsically Safe Temperature Data Logger with Stainless Steel Enclosure INSTRUCTION SHEET MQS5096/1216

User s Guide CS8DPT SERIES. Benchtop Controllers. Shop online at omega.com. For latest product manuals:

User s Guide HHSL-101. USB Digital Sound Level Data Logger. Shop online at omega.com SM

User s Guide. OM-HL-SH Series. Single Channel Temperature and Humidity Data Logger, Handheld. Shop online at omega.com

User s Guide. OM-HL-SP Series. Single Channel Temperature and Humidity USB Data Logger, Pen Size. Shop online at omega.com

Product User Guide. OctProcessV2 and QuadProcessV2. QuadProcessV2-3A 4-Channel Low Level DC Current

User s Guide OM-DAQXL. Modbus Interface. Shop online at omega.com. For latest product manuals:

OMB-DAQ-TC-RACK OMB-DAQ-2416 OM-NET-1608 OM-USB-32DIO

User s Guide. OM-HL-SP Series Single Channel Temperature and Humidity USB Data Logger, Pen Size. Shop online at omega.com

User s Guide. OM-HL-EH-TC Series Multi-channel Handheld Thermocouple Temperature Data Logger. Shop online at omega.com

User s Guide. DIN-190 and DIN-192 Series. Converter Boxes. Shop online at

User s Guide. OM-HL-SH Series. Single Channel Temperature and Humidity Data Logger, Handheld. Shop online at omega.com

Product User Guide. QuadTemp and OctTemp. QuadTemp 4-Channel Thermocouple Based Temperature Data Logger

User s Guide TXUN-KIT. Loop Link USB Communications Interface. Shop online at omega.com

User s Guide TX69. Universal Smart Transmitter. Shop online at. omega.com For latest product manuals: omegamanual.

User s Guide. DPU90-CT PC COMM / Sensor Configuration Tool

OM-DAQXL. Multi-Channel Universal Input Touch Screen Data Logger

User s Guide D6000 SERIES. Digital Transmitters Modbus RTU, RS-485 Output. Shop online at omega.com

User s Guide HHM-MG300. Wireless TRMS Multimeter and Insulation Tester. Shop online at omega.com

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA Of Course! Shop online at omega.com SM

User s Guide LVU30 SERIES. Ultrasonic Sensors. Shop online at omega.com. For latest product manuals:

User s Guide. DRSL-LPO Series. DIN Rail Loop Powered Isolators. Shop online at omega.com

User s Guide TCL Series Portable Sample Cooling Device

Product User Guide PR2000. PR2000 Pressure Data Logger with LCD

User s Guide HHPT-51. Particle Counter. Shop online at omega.com. For latest product manuals:

Shop online at omega.com

User s Guide. CSi32. Benchtop Controller. Shop online at omega.com. For latest product manuals:

Troubleshooting Tips & Procedures. Model 8800 series. GeoNet Wireless

User s Guide. CSi8DH SERIES. Benchtop Controllers. Shop online at. omega.com For latest product manuals: omegamanual.

Temperature & Process Controller/Monitor CNi8C-EN/DPi8C-EN

User s Guide WTC Shop online at. Wind Tunnel Controller. omega.com For latest product manuals: omegamanual.

User s Guide HHM250. AC Clamp Meter. Shop online at. omega.com For latest product manuals: omegamanual.info MADE IN TAIWAN

User s Guide DP26-TC. Differential Temperature Meter with Thermocouple. Shop online at omega.com

TM 2. User s Guide. Shop online at omega.com For latest product manuals: CDH-SD11

User s Guide DP301AN DC VOLTMETER DP301AN-AC VOLTMETER. Shop online at omega.com

User s Guide CT89 SERIES. Temperature Recorder. Shop online at. omega.com For latest product manuals: omegamanual.

User s Guide. Shop online at omega.com. FPD3100-D and FPD3100-D-A Series. 12mm LC Digital Display with Analog Output Options

User s Guide HHF-312. Mini Anemometer-Psychrometer With Compass And Memory. Shop online at omega.com SM

User s Guide LDN-PS. Shop online at. omega.com For latest product manuals: omegamanual.info. solartron

User s Guide DRSL-DC4. Bipolar Isolated DIN Rail Signal Conditioner. Shop online at omega.com

User s Guide HH520. Data Logger Thermometer. 4 Channel Type J, K, T, E. Shop online at omega.com

User s Guide Servicing North America:

OME-SERIES DATA ACQUISITION CARDS

HiTemp140-FP-TSK High Temperature Data Logger with Flexible RTD Probe and Thermal Shield

User s Guide. OM-CP-PR2000 Pressure Data Logger with LCD Display. Shop online at

User s Guide HH309A. Data Logger Thermometer. Shop online at. omega.com For latest product manuals: omegamanual.

User s Guide DP20. Economical Multisignal Meter for Process, Temperatures and Electrical signals. Shop online at omega.com

omega.com For Other Locations Visit omega.com/worldwide

Bluetooth USB Adapter TALUS. User Guide

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA... Of Course!

User s Guide. LVR300 Series. Shop online at. Continuous Level Switch System

User s Guide. POWERVAR Single Phase Power Conditioners

USB Server User Manual

User s Guide OM-DAQXL. Multi-Channel Universal Input Touch Screen Data Logger. Shop online at omega.com

User s Guide CL532. ma/v Loop Calibrator with Loop Diagnostic. Where Do I Find Everything I Need for Process Measurement and Control? OMEGA Of Course!

OMEGA. HH504 Digital Thermometer

OctTemp2000. Data Logger Manual

User's Guide. MiniTec TM Series Model MN25 MultiMeter

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

Advanced 8-Port DisplayPort Secure KVM Switch

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA... Of Course!

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

Advanced 2/4-Port DisplayPort Secure KVM Switch

MP3 Speaker USER GUIDE

ADVANCED 4/8-PORT SECURE KM SWITCH

Woolich Racing. USB ECU Interface User Guide

User s Guide USB Channel Isolated Digital I/O USB Data Acquisition Module. Shop online at

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

Document ID: DOC-IPG-2004 Revision: 1.10 Release Date: December 13th, Advanced 2/4-Port DVI-I Secure KVM Switch

Product User Guide CTL2000. CTL2000 Carcass Temperature Data Logger with 8 Remote Thermocouple Channels

3-Axis G-Force Datalogger

OM-CP-THERMALERT SERIES Precision Wireless Temperature Data Loggers

User s Guide. DP40 and DPF400. Series Indicators RS-232/RS-422/RS-485 Serial Communications. Shop on line at

Data Reporter. Installation-Operation E rev.f

Illuminate 25 Light Starter Kit What s included Light String Control Box Spare Fuses Safety Instructions Quick Start Guide

NMEA2000 DC MONITOR Part Numbers: 3410 USER MANUAL

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA... Of Course!

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA... Of Course!

ADVANCED 4/8 PORT DVI-D MATRIX SECURE KVM SWITCH

Industrial Rugged Metal USB

ARIENSE SENSE YOUR WORLD. 3-Axis Force Sensor FSE103. User Guide. Version 2.1. July VARIENSE INC.

OPERATION MANUAL BO BLASTER S OHMMETER

User Guide. ExStik TM Model RE300 Waterproof ORP Meter. Patent Pending RE300 ORP

VELOCICALC Air Velocity Meter

MLC. Semi Metal USB. Generation 5 / 5L HERCULES-PB Series. Product Specification MLC. Semi Metal USB Flash Disk Generation 5/5L

User's Guide. Model Laser Photo Tachometer

MLC. Semi-Metal USB. Generation 3L HERMIT-C Series. Product Specification MLC. Semi-Metal USB Flash Disk Generation 3L

Transcription:

OM-CP-QUADVOLT Xxxxx Xxxxxx 4-Channel Low Level DC Voltage Data Logger OM-CP-OCTVOLT 8-Channel Low Level DC Voltage Data Logger INSTRUCTION SHEET MQS5086/1216 Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info

Product Overview Engineering Units Engineering units are used to convert one measurement reading to another. The OM-CP Data Logger software allows for software level Engineering Units (conversion applied to data after download). Certain devices have device level Engineering Units, which upon download automatically appear in the chosen unit of measure. Wiring the Data Logger OM-CP-QUADVOLT and OM-CP-OCTVOLT Single Ended Wiring (2.5, 15 and 30V) Two-position removable screw terminal connections; accepts 2-wire configurations. OM-CP-QUADVOLT and OM-CP-OCTVOLT Differential Wiring (+-100mV) Three-position removable screw terminal connections; accepts 3-wire configurations. Warning: Note the polarity instructions. Do not attach wires to the wrong terminals.

Installation Guide Installing the Interface Cable - OM-CP-IFC200 Insert the device into a USB port. The drivers will install automatically. - OM-CP-IFC110 Plug the serial cable into the port and verify it is secure. Installing the software Insert the Omega Software Flash Drive in an open USB port. If the autorun does not appear, locate the drive on the computer and double click on Autorun.exe. Follow the instructions provided in the Wizard. Device Operation Connecting and Starting the data logger - Once the software is installed and running, plug the interface cable into the data logger. - Connect the USB end of the interface cable into an open USB port on the computer. - The device will appear in the Connected Devices list, highlight the desired data logger. - For most applications, select Custom Start from the menu bar and choose the desired start method, reading rate and other parameters appropriate for the data logging application and click Start. ( Quick Start applies the most recent custom start options, Batch Start is used for managing multiple loggers at once, Real Time Start stores the dataset as it records while connected to the logger.) - The status of the device will change to Running, Waiting to Start or Waiting to Manual Start, depending upon your start method. - Disconnect the data logger from the interface cable and place it in the environment to measure. Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the device cannot be restarted until it has been re-armed by the computer. Downloading data from a data logger - Highlight the data logger in the Connected Devices list. Click Stop on the menu bar. - Once the data logger is stopped, with the logger highlighted, click Download. You will be prompted to name your report. - Downloading will offload and save all the recorded data to the PC.

Device Maintenance Battery Replacement Materials: 3/32 HEX Driver (Allen Key) and Replacement Battery (OM-CP-BAT103) - Remove the cover from the device by unscrewing the four screws. - Remove the battery from its compartment and unsnap it from the connector. - Snap the new battery into the terminals and verify it is secure. - Replace the cover taking care not to pinch the wires. Screw the enclosure back together securely. Note: Be sure not to over tighten the screws or strip the threads. Recalibration The OM-CP-QUADVOLT or OM-CP-OCTVOLT standard calibration is dependant upon the range. Range 100mV 2.5V 15V 30V Calibration Point 90-100mV 2.25-2.5V 14.9-15.5V 27-30V Recalibration is recommended annually for any Omega data logger; a reminder is automatically displayed in the software when the device is due. Specifications subject to change. See Omega s terms and conditions at www.omega.com

OM-CP-QUADVOLT General Specifications Description OM-CP-QUADVOLT Voltage Range Voltage Resolution *See Table Below Voltage Accuracy Memory 32,767/channel Reading Rate 1 reading every second up to 1 reading every 12 hours LED Indicator None Channels 4 Required Interface Package IFC110 or IFC200 Baud Rate 2,400 Typical Battery Life 1 year Operating Environment -40 C to +60 C, 0%RH to 95%RH (non condensing) Material Anodized aluminum Dimensions 3.5 x 4.4 x 1.0 (89 mm x 112 mm x 26 mm) Weight 13 oz (370 g) *OM-CP-QUADVOLT Range, Resolution and Calibrated Accuracy Nominal Range +-100mV 0 to 2.5V 0 to 15V 0 to 30V Measurement Range (VDC) +-150mV -0.25 to 2.75-1 to 16-2 to 32 Accuracy +-0.01%FSR +-0.01%FSR +-0.10%FSR +-0.10%FSR Resolution (mv) 5µV 0.1 0.5 1.0 Common Mode Input Range 0 to 2.5V 0 to 2.5V 0 to 2.5V 0 to 2.5V Battery Warning WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE, FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 60 C (140 F). Specifications subject to change. See Omega s terms and conditions at www.omega.com Still need help? For more troubleshooting tips and information, refer to the built in help section visit us online at www.omega.com or contact us for support at 1 (800) 872-9436.

OM-CP-OCTVOLT General Specifications Description OM-CP-OCTVOLT Voltage Range Voltage Resolution *See Table Below Voltage Accuracy Memory 16,383/channel Reading Rate 1 reading every second up to 1 reading every 12 hours LED Indicator None Channels 8 Required Interface Package IFC110 or IFC200 Baud Rate 2,400 Typical Battery Life 1 year Operating Environment -40 C to +60 C, 0%RH to 95%RH (non condensing) Material Anodized aluminum Dimensions 3.5 in x 4.4 in x 1.5 in (89 mm x 112 mm x 39 mm) Weight 17 oz (480 g) *OM-CP-OCTVOLT Range, Resolution and Calibrated Accuracy Nominal Range +-100mV 0 to 2.5V 0 to 15V 0 to 30V Measurement Range (VDC) +-150mV -0.25 to 2.75-1 to 16-2 to 32 Accuracy +-0.01%FSR +-0.01%FSR +-0.10%FSR +-0.10%FSR Resolution (mv) 5µV 0.1 0.5 1.0 Common Mode Input Range 0 to 2.5V 0 to 2.5V 0 to 2.5V 0 to 2.5V Battery Warning WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE, FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 60 C (140 F). Specifications subject to change. See Omega s terms and conditions at www.omega.com Still need help? For more troubleshooting tips and information, refer to the built in help section visit us online at www.omega.com or contact us for support at 1 (800) 872-9436.

omega.com info@omega.com U.S.A. Headquarters: Servicing North America: Omega Engineering, Inc. Toll-Free: 1-800-826-6342 (USA & Canada only) Customer Service: 1-800-622-2378 (USA & Canada only) Engineering Service: 1-800-872-9436 (USA & Canada only) Tel: (203) 359-1660 Fax: (203) 359-7700 e-mail: info@omega.com For Other Locations Visit omega.com/worldwide The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs. OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a Basic Component under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner. RETURN REQUESTS / INQUIRIES Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA: 1. Purchase Order number to cover the COST of the repair, 2. Model and serial number of the product, and 3. Repair instructions and/or specific problems relative to the product. OMEGA s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. Copyright 2016 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.