General Specifications. P2-SCM Serial Communications

Similar documents
P3-SCM. General Specifications

P1-540 CPU. CPU Specifications

P3-RS Remote Slave Module

P2-04DAL-2 Analog Output. Removable Terminal Block Specifications

P3-RS Remote Slave. Remote Slave Specifications. The P3-RS is a full-featured, highperformance,

P2-16AD-2 Analog Input. Connector Specifications

P2-04DA Analog Output. Removable Terminal Block Specifications

P USB 2.0 (Type B) Port - Programming - Online monitoring

General Specifications. P2-8AD4DA-2 Analog Input/Output

P2-04AD Analog Input. Removable Terminal Block Specifications

General Specifications. P2-08NTC Thermistor. The P2-08NTC module provides eight Thermistor input channels for use with the Productivity2000 System.

General Specifications. P2-08THM Analog Input

P3-530 CPU. CPU Specifications. The P3-530 is a high-performance CPU for use with the Productivity3000 Programmable Automation Controller.

P2-HSO High-Speed Isolated Sinking/Sourcing Output. Connector Specifications

Do-more H2 Series PLC System Specifications

T1K MODBUS Base Controller Specifications

P3-08RTD Analog Input

Removable Terminal Block Specifications

APPENDIX B SERIAL I/O MODULE INSTALLATION / OPERATION WHEN USING T&D VER. 5.2 OR 5.3

Serial Communication Converters & Adapters Instruction Manual

SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

PCI Express 4-Port Industrial Serial I/O Cards

GE Fanuc IC695CMM004. Rx3i PacSystem

MEV Limited USB232/485 INSTRUCTION MANUAL

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Digital ac/dc (24V) Input Module

PACSystems* RX3i IC695CMM002 and IC695CMM004

MGate 4101-MB-PBS Series

DATA CONNECT ENTERPRISE

Installation and Setup

ICF-1150 Series Quick Installation Guide

Communications Quick-Start Guide

TCF-142-RM Series Hardware Installation Guide

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

PACSystems* RX3i IC695CMM002 and IC695CMM004

MGate 5105-MB-EIP Series

Carbon Monoxide Sensor - ModBus

GT- IRDM-9603 Product description Rev. 2 17/06/2014

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Chapter. Modbus. In This Chapter...

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

HRM-0800 Instruction Manual

Moxa TCC-100 Series Hardware Installation Guide

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

GE Fanuc Automation Programmable Control Products. PACSystems RX3i. Serial Communications Modules. User s Manual, GFK-2460A.

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

TXP3500/4000 Series AC-DC Industrial PSU

RS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount

Support 1 RS-232 or RS-485/422 serial port to 1 10/100Base-T(X) self-adaptive Ethernet interface

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

H704-42(H)(E), H704-42/1(H)(E)

EZ864 UMTS Terminal Telit Cellular GSM Engine

PACSystems* RX3i IC695CMM002-EG and IC695CMM002CA-EG IC695CMM004-EG, IC695CMM004CA-EG, and IC695CMM004LT-EG

Product Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M

Manual Industry Interfaces

ICF-1150 Series Quick Installation Guide

Moxa TCC-100 Series User s Guide

ASTAT XB/XBm Remote Operator

Automationdirect.com. D i r e c t L o g i c M O D B U S S L A V E F 4 S L V - M B

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

AQ_G24 GSM Terminal Card Motorola Cellular GSM Engine

-C5RS-LC RS232 EXTENDER

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway

RS-485 MicroLinK HM Setup Software Installation Operation & Specifications Manual

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

COM32. Installation & Operation Manual

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

Mini Digital Multimeter

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

General Operating, Maintenance and Installation Manual

DATA SHEET DEPRECATED - PCM5 1. Document no.: N/A

CAN485. Wall Mounting CAN to RS-485 Interface Converter. Support data conversion between 1 CAN port and 1 RS-485 serial port

The 2U package makes the unit suitable for using in workstations, storage systems, racks for industrial and many other applications.

CompactBlock Guard I/O EtherNet/IP Safety Modules

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

CS485. User s Manual. Version ZYPEX, Inc.

ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB

SATEL-LP-AI4. I/O extension module, 4 analog current inputs. Data sheet. 1 Description

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

Ethernet to Digital I/O +RS232 +Switch

Safety: UL508 EMC: CE IEC , IEC Vibration: IEC (2 g s during operation) Warranty

Industrial Isolated Converters

RTU560 Connections and Settings DIN Rail RTU 560CIG10

MD3. Microstepping Motor Driver Page 1 of 7. Description. Software. Mechanical Drawing. Features

icex-cmtm General specs and Installation guide

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language)

Features. Preliminary. Industrial IEEE b/g/n with 2x10/100Base-T(X) 1x RS-232/422/485 IoT LTE LPWAN Gateway. Introduction

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

EasySYNC Ltd. USB to Serial Converters Manual

TABLE OF CONTENTS. Communication Functions

USB to RS-232/RS422/485. URK-228-I USB To Serial Operation Manual

Transcription:

General Specifications Module Type Intelligent Modules per Base I/O Points Used Field Wiring Connector Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Agency Approvals Module Location Weight 15 maximum* None, mapped directly to tags in CPU 3 - RJ12, 1-4 Position Terminal Block 0º to 60ºC (32º to 140ºF) -20º to 70ºC (-4º to 158ºF) 5 to 95% (non-condensing) No corrosive gases permitted IEC 60068-2-6 (Test Fc) IEC 60068-2-27 (Test Ea) None No isolation UL508 File E139594, Canada & USA CE (EN61131-2007) Any slot in any base in a Productivity2000 System 90g (3.2 oz) *Note: For complete system limits, please refer to the Hardware and Communication Limits table in the Prodctivity Suite Help file, Automatic Hardware Configuration topic (P050). 2000 P2-SCM Serial Communications The P2-SCM Serial Communications Module provides three RS-232 ports and one RS-485 port for Modbus master/slave networking or to serial devices using ASCII or custom communication protocols. Port 1 Powers a C-More Micro when using an RJ-12 connector. General Specifications... 1 SCM Front Panel... 2 Module Installation Procedure... 2 P2-SCM Configuration Options... 3 RS-232 Port Specifications... 4 RS-485 Port Specifications... 4 Port 1 (RS-232) Specifications... 5 Port 2 & 3 (RS-232) Specifications... 5 Port 4 (RS-485) Specifications... 6 Diagnostic LEDs... 7 Warning... 8 Removable Terminal Block Specifications........ 8 Cable Options... 8 Hot Swap Information... 8 Document Name Edition/Revision Date P2-SCM-DS 1st Ed. 3/6/2015 Copyright 2015, AutomationDirect.com Incorporated/All Rights Reserved Worldwide Sales 800-633-0405 Warranty: Thirty-day money-back guarantee. Two-year limited replacement. (See www.productivity2000.com for details). www.productivity2000.com 1

P2-SCM Front Panel Module Installation STATUS DISPLAY - 14 LEDS - Shows communication status for each port WARNING: Do not apply field power until the following steps are completed. See hot-swapping procedure for exceptions. Step One: Align module catch with base slot and rotate module into connector. 2 rotate to seated position 1 Align with slot PORT 2 - RS-232 PORT 1 - RS-232 - Provides 210mA 5V power for C-More Micro Step Two: Pull top locking tab toward module face. Click indicates lock is engaged. Locked Unlocked PORT 3 - RS-232 PORT 4 - RS-485 WARNING: Explosion hazard Do not connect or disconnect connectors or operate switches while circuit is live unless the area is known to be non-hazardous. Do not hot-swap modules unless the area is known to be non-hazardous. 2 www.productivity2000.com Tech Support 770-844-4200

P2-SCM Configuration Options Configuration Item Port 1 (RS-232) Ports 2 & 3 (RS-232) Port 4 (RS-485) Protocol Selections Disabled, Modbus RTU, ASCII/Custom Disabled, Modbus RTU, ASCII/Custom Disabled, Modbus RTU, ASCII/Custom Data Rate 1200, 2400, 4800, 9600, 19200, 33600, 38400 1200, 2400, 4800, 9600, 19200, 33600, 38400 1200, 2400, 4800, 9600, 19200, 33600, 38400 Parity None, Odd or Even None, Odd or Even None, Odd or Even Data Bits 4 7 or 8 bits 7 or 8 bits 7 or 8 bits RTS Off Delay Time 1 None, or 0-5,000 ms None, or 0-5,000 ms RTS On Delay Time 1 None, or 0-5,000 ms None, or 0-5,000 ms Modbus Character Timeout 2 None, or 0-10,000 ms None, or 0-10,000 ms None, or 0-10,000 ms Communication Timeout (Timeout between query and response) 500-10,500 ms 500-10,500 ms 500-10,500 ms Response/Request Delay Time None, or 1-5,000 ms Comm Heartbeat Value 2 2-1,000 sec 2-1,000 sec 2-1,000 sec Node Address (Station) 1 to 247 1 to 247 1 to 247 CTS Ignore, Wait, System Input 3 Enable/Disable CTS Wait Timeout 1-9999 tenths of seconds 1-9999 tenths of seconds RTS On, Off, Assert During Transmit, System Output On, Off, Assert During Transmit, System Output RS-485 2-Wire Mode Disable, Enable Modbus Port Security Read/Write, Read Only Read/Write, Read Only Read/Write, Read Only 1. For None selection with Modbus RTU protocol, Modbus.org minimums are used. This minimum is 3.5 character times up to 19, 200 baud rate and 1.75ms over 19,200 baud rate 2. Only applies to Modbus messages 3. CTS signal is only provided on Ports 2 & 3 4. 7-bit data are only supported with Odd or Even parity Sales 800-633-0405 www.productivity2000.com 3

Port Specifications RS-232 Ports 1, 2 & 3 Electrical Specifications Min Typ Max Units Output ON, Space Condition (3kΩ, 1000pF Load) 5.0 5.2 Volts Output OFF, Mark Condition (3kΩ, 1000pF Load) -5.2-5.0 Volts Output Short-Circuit Current 15 ma Short-Circuit Duration No Limit Seconds Output Resistance 300 Ohm Input ON Threshold 1.6 2.4 Volt Input OFF Threshold 0.6 1.2 Volt Input Resistance 3k 5k 7k Ohm Line Specifications for RS-232 Ports RS-232 Line Specifications Options Units Data Rate Setting 1200, 2400, 4800, 9600, 19200, 33600, 38400 Baud Data Rate Error ±2 % Data Bits Setting 1 7 or 8 Bits Stop Bits Setting 1 Bits Parity Setting None 1, Odd or Even Parity Data Transmission Half duplex or full duplex Network Point-to-Point 1. 7-bit data are only supported with odd or even parity RS-485 Port 4 Electrical Specifications Min Typ Max Units Driver Differential Output (54Ω Load) 1.5 Volts Driver Common-Mode Output 3 Volts Driver Short-Circuit Output Current 250 ma Short-Circuit Duration (Thermal Shutdown) No Limit Seconds Receiver Differential Input Threshold 200 mv Receiver Common-Mode Input -7 12 Volt Input Resistance 12k Ohm Termination Resistance 120 (TB Jumper wire T to + ) Ohm Data Rate 1200 38400 Baud Data Rate Error ±2 % Cable Length (38400 baud maximum) 1200 Meter Line Specifications for RS-485 Port RS-485 Line Specifications Options Units Data Rate Setting 1200, 2400, 4800, 9600, 19200, 33600, 38400 Baud Data Bits Setting 1 7 or 8 Bits Stop Bits Setting 1 Bits Parity Setting None 1, Odd or Even Parity Data Transmission Half duplex 1. 7-bit data are only supported with odd or even parity 4 www.productivity2000.com Tech Support 770-844-4200

Port 1 Port Type RS-232 Non-isolated RS-232 DTE port connects the CPU as a Description Modbus/ASCII master or slave to a peripheral device. Includes ESD and built-in surge protection. Data Rates Selectable, 1200, 2400, 4800, 9600, 19200, 33600, and 38400 +5V Cable Power Source 210mA maximum at 5V, ±5%. Reverse polarity and overload protected TXD RS-232 Transmit output RX RS-232 Receive input RTS Handshaking output for modem control GND Logic ground Maximum Output Load (TXD/RTS) 3kΩ, 1,000pF Minimum Output Voltage Swing ±5V Output Short Circuit Protection ±15mA Port Status LED Red LED is illuminated when active for TXD, RXD and RTS EA-MG-PGM-CBL D2-DSCBL Cable Options USB-RS232 with D2-DSCBL FA-CABKIT FA-ISOCON for converting RS-232 to isolated RS-485 Port 2 and 3 (RS-232 Configuration) Port Type RS-232 Non-isolated RS-232 DTE port connects the CPU as a Description Modbus/ASCII master or slave to a peripheral device. Includes ESD and built-in surge protection. Data Rates Selectable, 1200, 2400, 4800, 9600, 19200, 33600, and 38400 TXD RS-232 Transmit output RX RS-232 Receive input RTS Handshaking output for modem control GND Logic ground Maximum Output Load (TXD/RTS) 3kΩ, 1,000pF Minimum Output Voltage Swing ±5V Output Short Circuit Protection ±15mA Port Status LED Red LED is illuminated when active for TXD, RXD and RTS D2-DSCBL Cable Options USB-RS232 with D2-DSCBL FA-CABKIT FA-ISOCON for converting RS-232 to isolated RS-485 6 1 6-pin RJ12 Female Modular Connector Pin # Signal 6 GND Logic Ground 5 RTS RS-232 Output 4 TXD RS-232 Output 3 RXD RS-232 Input 2 +5V 210mA Maximum 1 GND Logic Ground 6 1 6-pin RJ12 Female Modular Connector Pin # Signal 6 GND Logic Ground 5 RTS RS-232 Output 4 TXD RS-232 Output 3 RXD RS-232 Input 2 CTS RS-232 Input 1 GND Logic Ground Sales 800-633-0405 www.productivity2000.com 5

Port 4 (RS-485 Configuration) Port Type RS-485 Non-isolated RS-485 port connects the CPU as a Description Modbus/ASCII master or slave to a peripheral device. Includes ESD/EFT protection and automatic echo cancellation when transmitter is active. Data Rates Selectable, 1200, 2400, 9600, 19200, 33600, 38400 TXD+/RXD+ RS-485 transceiver high TXD-/RXD- RS-485 transceiver low GND Logic Ground Input Impedance 19kΩ Maximum Load 50 transceivers, 19kΩ each, 60Ω termination Output Short Circuit Protection ±250mA, thermal shut-down protection Electrostatic Discharge Protection ±8kV per IEC1000-4-2 Electrical Fast Transient Protection ±2kV per IEC1000-4-4 Minimum Differential Output Voltage 1.5 V with 60Ω load Fail Safe Inputs Logic high input state if inputs are unconnected Maximum Common Mode Voltage -7.5 V to 12.5 V Port Status LED RED LED Illuminated when active for TXD and RXD Cable Options Recommend L19827-XXX from AutomationDirect.com G - + T Pin # Signal G GND TXD-/RXD- + TXD+/RXD+ T TERMINATION RS-485 6 www.productivity2000.com Tech Support 770-844-4200

Diagnostic LEDs LED Port 1 Port 2 Port 3 Port 4 RXD X X X X TXD X X X X RTS X X X CTS X X 5V X 1 - All RS232 & RS485 LED s reflect the actual electrical level of the signal, there is no direct firmware control of LED s 2 - RS232 LED s RXD, TXD, RTS & CTS are turned ON when their voltage on the RS232 wire is postive (MARK) a - This occurs when the UART I/O signal is low (GND) b - They are turned OFF when the voltage on the RS232 wire is negative (SPACE) 3 - RS485 LED s RXD & TXD are turned ON when the UART I/O signal is low (GND) 4-5V LED is ON when 5V power is good, 5V LED is OFF when 5V is shorted to ground Sales 800-633-0405 www.productivity2000.com 7

WARNING: To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from area to area and it is your responsibility to determine which codes should be followed, and to verify that the equipment, installation, and operation are in compliance with the latest revision of these codes. Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. We do not guarantee the products described in this publication are suitable for your particular application, nor do we assume any responsibility for your product design, installation, or operation. If you have any questions concerning the installation or operation of this equipment, or if you need additional information, please call Technical Support at 770-844-4200. This publication is based on information that was available at the time it was printed. At AutomationDirect.com we constantly strive to improve our products and services, so we reserve the right to make changes to the products and/or publications at any time without notice and without any obligation. This publication may also discuss features that may not be available in certain revisions of the product. Removable Terminal Block Specs (Port 4) Number of Positions Wire Range Screw Driver Size Screw Torque 4 Screw Terminals, 3.5 mm Pitch 16-28 AWG Solid/Stranded Conductor Use Copper Conductors, 75 C or Equivalent TW-SD-VSL-1 (Recommended) 0.4 N m Caution: If possible, remove field power prior to proceeding. If not, then EXTREME care MUST be taken to prevent damage to the module, or even personal injury due to a short circuit from the live terminal block. Important Hot-Swap Information The Productivity2000 System supports hot-swap! Individual modules can be taken offline, removed, and replaced while the rest of the system continues controlling your process. Before attempting to use the hotswap feature, be sure to read the hot-swap topic in the programming software s help file or our online documentation at AutomationDirect.com for details on how to plan your installation for use of this powerful feature. Cable Options Recommended L19827-100, Belden #9841 or Equivalent 8 www.productivity2000.com Tech Support 770-844-4200