Weathersafe Vision. Installation & Operating Instructions

Similar documents
RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

Slimline LED Floodlight

18W Round LED Bulkhead Light with Microwave Sensor

7 Day Digital Programmer 1 Channel Surface Mount

7 Day Digital Programmer 2 Channel Surface Mount

7 Day Programmable Room Thermostat

Wireless 7 Day Programmable Room Thermostat

2x 10W LED Slimline PIR Floodlight Twin Flood

Mini Recessed PIR. Model: PDFM360MINI. Installation & Operating Instructions

2400W PIR Light Controller

BOOSTMASTER ELECTRONIC BOOST TIMER

Slimline. Technical Hotline

INSTALLATION & OPERATING INSTRUCTIONS

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

SAVE THESE INSTRUCTIONS

Technical Data. Wi-Fi Socket Range Extender. Features: 922WR

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

Orbital smart Tunable Downlight

Conveyor Belt Alignment Switches from IDEM

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Chroma Plus 130 decorative High quality, lustrous finish with modern curved design Total safety

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

SolConeX Wall-Mounted Socket, 16 A

METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no.

Operating Instructions

B60 Domestic Voltage Optimisation Unit. Installation Manual

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 230 Volt

WIRED REMOTE INSTALLATION GUIDE


See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Operating Instructions

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

B60 Domestic Voltage Optimisation Unit. Installation Manual

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

STANDALONE NIGHT SENSOR

RТTH DUAL ROOM SWITCH

POCKET MULTIMETER Model No: MM18

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Vimark. t: e: w: detaelectrical.co.uk

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

Model HM-535 Power Supply Installation and Service Instructions

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

RECTANGULAR LED 3060-L L L-8060

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

RXTH DUAL ROOM SENSOR / SWITCH

Quick Start Guide TS A

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

B60 Domestic Voltage Optimisation Unit

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

CG800H SERIES USER MANUAL ZIGBEE WIRELESS SCENE CONTROL PANEL VERSION JANUARY, Disclaimers and Copyright

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Swing-Arm Reading Lamp

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

DUAL MONO POWER AMPLIFIER INSTRUCTIONS FOR USE

Sollatek SVS Range Voltage Stabilisers User Manual

For Models #2384W/I (and Slave Remote Dimmer Model #1135W/I)

Digital Room Thermostat

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

B60 PVM Domestic Voltage Optimisation Unit. Installation Manual

Front-door station series for surface-mounting Profi-Economic PES Profi-Design PDS

Product Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23

Plexo IP 55/IP 66. Makes your day, rain or shine PLEXO / WEATHERPROOF PRODUCT GUIDE. For reference only.

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

Installation Manual. APEX Series. Silicon and MOV Panel Protection. APEX Series

Surface-Mounting Product Ranges

Product and functional description

FDS / FDS-R / FDS-PS

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Metal Clad Wiring Accessories. A rugged scratch resistant metal, suitable for everyday use in commercial and industrial environments

Digital Keypad Introduction

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

Plexo IP 55/IP 66 Makes your day, rain or shine

Operating and Maintenance Instructions

Technical Data. Surface Boxes And Blank Plates. Brief product description: Features:

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and functional description

SSR 303 One Channel 3 Amp Switch (Rx Only) - Z-Wave. User and Installation Instructions

Installation manual plugs and connectors with screw connection (16/32 A)

HEMP & IEMI PROTECTION FILTERS FOR MAINS POWER LINES

D-Pack 6 Classic ORDERCODE 50315

elucent WPFC Series LED Wall Pack Product Description WPFC Series Family Model Performance Summary WPFC40 WPFC60 WPFC90

Model 7705 Control Module

Installation Instructions & User Manual POWERWARE TVSS ZONESENTINEL. AC Panel Transient Voltage Surge Suppressors

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures)

XTRA Surface Metalclad Accessory Range

Transcription:

Weathersafe Vision Installation & Operating Instructions

IP66 Products covered by these instructions 1 TGVL01 TGVL02 TGVL03 TGVL05 TGV101N TGV201N TGV104N Single Gang 2-Way Switch [SP] 10AX (Fluorescent rated) Twin Gang 2-Way Switch [SP] 10AX (Fluorescent rated) Single Gang Bell Push Switch [SP] 10AX (Fluorescent rated) Single Gang Switch [DP] 20AX (Fluorescent rated) Single Gang Socket Switched 13A Twin Gang Socket Switched 13A Single Gang RCD Fused Spur 13A TGV204N Twin Gang RCD Socket Switched 13A (Passive/Latching) TGV205N Twin Gang RCD Socket Switched 13A (Active/Non-Latching) TGV103N Single Gang Switched Fused Spur 13A with Neon 1. General Information These instructions should be read carefully and retained for further reference and maintenance. All Weathersafe Vision products need to be fitted with waterproof cable and conduit entries to maintain their IP rating once installed. 2. Safety Before installation or maintenance, ensure the mains supply to the switch, socket, spur or bell push unit is switched off and the circuit supply fuses are removed or the circuit breaker turned off.

It is recommended that a qualified electrician is consulted or used for the installation of this IP66 rated switch, socket, spur or bell push unit and install in accordance with the current IEE wiring and Building Regulations. Check that the total load on the circuit including when this switch, socket, spur or bell push unit is fitted does not exceed the rating of the circuit cable, fuse or circuit breaker. Electricity can be dangerous; the use of an RCD should not be regarded as a substitute for basic electrical safety precautions. Always test the RCD before use. If the test procedure is not completed satisfactory or an appliance continues to trip the RCD seek professional advice and switch off the appliance. To clean, use a clean dry cloth only. Do NOT use any liquid cleaners. During use warming of the enclosure is normal. 2 Wiring tests Important (TGV104N, TGV204N & TGV205N) Remove this product from the circuit if carrying out tests (as described in the IEE Wiring Regulations) for earth loop impedance, prospective short circuit current and insulation resistance. Use the enclosed warning label to ensure this is carried out. 3. Technical Specifications General Voltage: 230V AC 50Hz IP Rating: IP66 All products in the range comply with the low voltage directive 2014/35/EU and where relevant the EMC directive 2014/30/EU and ROHS directive 2011/65/EU. CE Compliant

Switches (TGVL01, TGVL02, TGVL03, TGVL05) Backlit neon (illuminates switch for dark areas) Rocker Switch Rating: 13Amp (3kW) 10AX Operating temperature range: -5 to 55 C Complies with: BS EN 60669 Sockets (TGV101N & TGV201N) Individual power ON Neon Indicators Lockable cover facility Operating temperature range: -5 to 55 C Complies with: BS1363 3 RCD S (TGV104N, TGV204N, TGV205N) Lockable cover facility Rated trip current: 30mA RCD Type: Double pole, suitable for 2 and 3 wire applications Breaking capacity: 250A (Earth leakage) Through fault withstand: 1500A Trip Speed: Less than 40msec at 150mA residual current Classification: TGV104N Latching (Passive) TGV204N Latching (Passive) TGV205N Non-latching (Active) Operating temperature range: -5ºC to 40ºC Complies with: BS7288 & BS1363 Fused Spur (TGV103N) Power ON Neon indicator Lockable cover facility Operating temperature range: -5 to 55 C Complies with: BS1363

4. TGVL01, TGVL02, TGVL03, TGVL05 Installation 1. IMPORTANT Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation. 2. Remove the black coloured rocker switch from the faceplate pivot support joints using a suitable flat ended screwdriver. Using a Philips screwdriver, separate the faceplate from the back box by removing the four tapped screws located in each corner. See figure 1. Backlit neon Tapped screws 4 Face plate pivot support joints Figure 1 This applies to the following models: TGVL01, TGVL02, TGVL03 & TGVL05 3. Using the back plate as a template mark the position for the holes. Note the back plate must be mounted in the correct orientation, following the TOP marking inside the back plate. If the mounting position desired is uneven use a sheet of marine ply as a base plate and fit the back box. 4. Drill the wall using a 4mm Ø drill bit making sure not to infringe or compromise any gas, water pipes or cables. Insert the rawl plugs into the holes. 5. The drain feature must be drilled out using a 5mm drill if the top or side entry conduit is used. Opening this drain hole will reduce the IP rating of the product. Remember open out the lower drain feature only.

5 6. Cut out the knock-out entry point by carefully scoring the groove carefully with a sharp knife and using a small hammer for tapping off the entry point. If conduit is not going to be used, a waterproof cable with suitable IP rated 20mm glands will be required to maintain the overall IP rating. If the bottom entry conduit is used, there must be adequate drainage from the lowest point of the conduit. 7. Follow suit using the same method depicted in stage 6 to create an exit point for the output supply cable to follow through on. 8. Secure the back box to the wall using suitable screws for the rawl plugs installed. Ensure that the back box is correctly orientated following the TOP marking which is labelled inside. 9. Pass though the 230V AC 50Hz mains supply cable and secure the cables tightly to their respective terminals. Ensure that all bare conductors are sleeved and that correct polarity is observed; see figure 2 for the appropriate wiring method. Note that if metal conduit is being used the earth continuity between the conduits must be maintained. 10. Once the mains supply is connected to the correct terminals, mount the face plate over the back box aligning the four screws from the face plate to the four mounting holes on the back box. Tighten until secured. 11. Once the face plate and back box have been mounted clip the hinge of the rocker switch to the pivot support joints of the face plate and push until even on both sides.

C 4.1 TGVL01, TGVL02, TGVL03, TGVL05 Wiring Diagrams Figure 2 230V 50Hz Live in Switched Normally Normally Live to lamp closed closed 230V 50Hz Neutral in Live in Switched Live to lamp Neon A1 B1 A1 C B1 A1 C B1 A1 C B1 A2 L B2 A2 L B2 A2 L B2 A2 L B2 Neon Neutral 230V 50Hz Live in Normally open Normally open Live out Neutral out Neon Neutral 230V 50Hz Live in Neon Neutral 230V 50Hz Live in 6 TGVL01 TGVL02 TGVL03 TGVL05 If a local neutral is required to give permanent indication of switch position using the neon supplied, or for wiring purposes, then use one of the earth terminals shown in figure 3 as a neutral wiring terminal. Note: This is the only way the neon should be connected. One of these two terminals marked earth can be used as a neutral terminal. Figure 3 TGVL01, TGVL02, TGVL03 Earth Terminal Positions

5. TGV101N, TGV201N & TGV103N Installation 1. IMPORTANT Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation. 2. Using a Philips screwdriver, separate the faceplate from the back box by removing the four tapped screws located in each corner. See figure 4 & 5 for your chosen product. 7 ON/OFF switches Individual backlit neon indicators Tapped screws Figure 4 Features apply to both TGV101N and TGV201N Lid clip for padlocks Neon status indicator Tapped screws ON/OFF switch Fuse socket Figure 5 TGV103N front plate

3. Using the back plate as a template mark the position for the holes. Note the back plate must be mounted in the correct orientation, following the TOP marking inside the back plate. If the mounting position desired is uneven use a sheet of marine ply as a base plate and fit the back box. 4. Drill the wall using a 4mm Ø drill bit making sure not to infringe or compromise any gas, water pipes or cables. Insert the rawl plugs into the holes. 5. The drain feature must be drilled out using a 5mm drill if the top or side entry conduit is used. Opening this drain hole will reduce the IP rating of the product. Remember open out the lower drain feature only, see figure 6. Figure 6 8 4x fixing holes for no. 8 wood screws Drain feature, use only lower if required Front cover fixing holes 6. Select the required entry point by unscrewing the appropriate seal located on all four sides of the back box. If conduit is not going to be used, a waterproof cable with suitable IP rated 20mm glands will be required to maintain the overall IP rating. If the bottom entry conduit is used, there must be adequate drainage from the lowest point of the conduit. 7. Follow suit using the same method depicted in stage 6 to create an exit point for the output supply cable to follow through on. 8. Secure the back box to the wall using suitable screws for the rawl plugs installed. Ensure that the back box is correctly orientated following the TOP marking which is labelled inside.

9. Pass though the 230V AC 50Hz mains supply cable and secure the cables tightly to their respective terminals ensuring that all bare conductors are sleeved and that correct polarity is observed, see figure 7, 8 or 9 for the appropriate wiring diagram of your chosen product. Note that if metal conduit is being used the earth continuity between the conduits must be maintained. 10. Once the mains supply is connected to the correct terminals, mount the face plate over the back box aligning the four screws from the face plate to the four mounting holes on the back box. Tighten until secured. 5.1 TGV101N, TGV201N & TGV103N Wiring Diagrams Figure 7 TGV101N 9 230V 50Hz AC Mains Supply Earth Mains Neutral Supply 230V 50Hz AC Mains Supply Mains Neutral Supply Figure 8 TGV201N Earth

Active 30mA Test (T) Before Use Red Flag ON Figure 9 TGV103N Earth Live Supply Out 230V 50Hz AC Mains Supply Earth Neutral Supply Out Mains Neutral Supply 10 6. TGV104N, TGV204N, TGV205N Installation 1. IMPORTANT Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation. 2. Using a Philips screwdriver, separate the faceplate from the back box by removing the four tapped screws located in each corner. See figure 10 & 11 for your chosen product Test button (T) Reset button (R) Red flag indicator (shown when current is live) Tapped screws Figure 10 TGV204N & TGV205N Front Plate Lid clip for padlocks

RCD16ML 30mA 1 n DP Flag above Reset R Red:ON Black:OFF ALWAYS TEST BEFORE USE Press Test T, flag should disappear. If not, do not use. Reset after testing Red flag indicator (shown when current is live) Reset button (R) F U S E Test button (T) Figure 11 TGV104N Front Plate Tapped screws Lid clip for padlocks 11 3. Using the back plate as a template mark the position for the holes. Note the back plate must be mounted in the correct orientation, following the TOP marking inside the back plate. If the mounting position desired is uneven use a sheet of marine ply as a base plate and fit the back box. 4. Drill the wall using a 4mm Ø drill bit making sure not to infringe or compromise any gas, water pipes or cables. Insert the rawl plugs into the holes. 5. The drain feature must be drilled out using a 5mm drill if the top or side entry conduit is used. Opening this drain hole will reduce the IP rating of the product. Remember open out the lower drain feature only. 6. Select the required entry point by unscrewing the appropriate seal located on all four sides of the back box. If conduit is not going to be used, a waterproof cable with suitable IP rated 20mm cable glands will be required to maintain the overall IP rating. If the bottom entry conduit is used, there must be adequate drainage from the lowest point of the conduit. 7. Follow suit using the same method depicted in stage 6 to create an exit point for the output supply cable to follow through on.

8. Secure the back box to the wall using suitable screws for the rawl plugs installed. Ensure that the back box is correctly orientated following the TOP marking which is labelled inside. 9. Pass though the 230V AC 50Hz mains supply cable and secure the cables tightly to their respective terminals ensuring that all bare conductors are sleeved and that correct polarity is observed, see figure 12 and 13 for the appropriate wiring diagram for your chosen product. Note that if metal conduit is being used the earth continuity between the conduits must be maintained. 10. Once the mains supply is connected to the correct terminals, mount the face plate over the back box aligning the four screws from the face plate to the four mounting holes on the back box. Tighten until secured. 12 6.1 TGV104N, TGV204N, TGV205N Wiring Diagrams Figure 12 TGV104N Neutral Supply to Load Earth Live Supply to Load 230V 50Hz AC Mains Supply Mains Neutral Supply

Figure 13 TGV204N Mains Neutral Supply Earth This diagram applies to both TGV204N & TGV205N 230V 50Hz AC Mains Supply 13 6.2 TGV104N, TGV204N and TGV205N Testing & Usage To test: Ensure supply is connected RESET press the grey (blue for TGV205N) button marked Reset (R), the status indicator should show red. Test press the red button marked Test (T), the status indicator should show black. This indicates that the RCD has been tripped and power has been disconnected from the outlet. RESET press the grey (blue for TGV205N) button marked reset (R) again; the status indicator should show red. If all the above operations work satisfactory, the RCD is safe for use. If this test procedure is not completed to a satisfactory standard, do not use the RCD and seek professional advice. In applications such as hand driers it may not be practical to expect each user to test before use. In this case we suggest an appropriate person applies the test routine twice a day. After satisfactory testing the RCD, any connected appliance may be switched on, and used in the confidence that the user is protected from electric shock by rapid disconnection of the supply.

3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515. Note: A proof of purchase is required in all cases. For all eligible replacements (where agreed by Timeguard) the customer is responsible for all shipping/postage charges outside of the UK. All shipping costs are to be paid in advance before a replacement is sent out. 14

If you experience problems, do not immediately return the unit to the store. Telephone the Timeguard Customer Helpline; HELPLINE 020 8450 0515 or email helpline@timeguard.com Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query. For a product brochure please contact: Timeguard Limited. Victory Park, 400 Edgware Road, London NW2 6ND Sales Office: 020 8452 1112 or email csc@timeguard.com www.timeguard.com 67.058.516 (Issue 2) Zerofour November 2016