A+ Certification Guide. Chapter 4 Power Supplies and System Cooling

Similar documents
Power Supplies. Chapter The McGraw-Hill Companies, Inc. All rights reserved. Mike Meyers CompTIA A+ Guide to Managing and Troubleshooting PCs

A+ Guide to Managing and Maintaining your PC, 6e. Chapter 4 Form Factors and Power Supplies

Chapter 5 Review. Power Supplies

AVR Series 120V 700VA 350W Ultra-Compact Line-Interactive UPS with USB port

AVR Series 120V 550VA 300W Ultra-Compact Line-Interactive UPS with USB port

Power supply (Power supply unit or PSU) is a device or system that supplies electrical or other types of energy to an output load or group of loads.

AVR Series 120V 700VA 350W Ultra-Compact Line-Interactive UPS with USB port

TAA-Compliant AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port

Model HM-535 Power Supply Installation and Service Instructions

Z8 G4 Site Prep Guide Table of contents

AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port

SmartPro 3U Rack/Tower Extended-Run UPS Line-interactive, sine wave UPS

USER Manual. Valens 500 / Valens 500M Valens 600 / Valens 500M Valens 700 / Valens 700M

Master List of Key Topics

Troubleshooting. Resetting the System. Problems Following Initial System Installation. First Steps Checklist CHAPTER

SmartPro LCD 120V 1200VA 700W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

Section 3 MUST BE COMPLETED BY: 10/17

PEM Faults and Blower Failures

BC Pro 120V 1400VA 940W Standby UPS, Tower, USB port, 6 Outlets

AVR Series 230V 550VA 300W Ultra-Compact Line-Interactive UPS with USB port, C13 Outlets

SmartPro LCD 120V 1500VA 900W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

Smart Pro Rack/Tower UPS Intelligent, line-interactive network power management system

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack, USB, DB9 Serial, LCD

SmartPro LCD 120V 1500VA 900W Line-Interactive UPS, AVR, Tower, LCD, USB, 10 Outlets

SmartPro LCD 120V 1300VA 720W Line- Interactive UPS, AVR, Tower, LCD, USB, 8 Outlets

SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, SNMPWEBCARD Option, LCD Display, USB, DB9 Serial

Eco 350VA Energy-saving Standby 120V UPS with USB port

ATX 450 and ATX 550 Watt Power Supplies

ECO Series 120V 900VA 480W Energy-Saving Standby UPS with USB, Muted Alarm and 12 Outlets

ECO Series 120V 350VA 180W Energy-Saving Standby UPS with USB and 6 Outlets

Chapter 3: Computer Assembly

What step should a technician perform first when servicing computer equipment?

SmartPro 120V 1kVA 750W Medical-Grade Line- Interactive Tower UPS with 4 Outlets, Full Isolation, USB, Lithium Battery

ECO Series 120V 850VA 425W Energy-Saving Standby UPS with USB port, LCD Display and 12 Outlets

FUNCTIONS OF COMPONENTS OF A PERSONAL COMPUTER

SmartPro Dual Voltage Tower UPS System Maintains 120V nominal output with either 120V or 230V input power

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MEMORANDUM SUBJECT: APPROVED POWER STRIPS AND SURGE PROTECTORS

4170 POS System Installation Guide

SmartPro LCD 120V 50/60Hz 1500VA 900W Line- Interactive UPS, AVR, Tower, LCD, USB, 10 Outlets

Introduction to the Personal Computer

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

AVR Series 230V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port, French/Belgian Outlets

BC Pro 120V 1400VA 940W Standby UPS, Tower, USB port, 6 Outlets

Model #: ECO350UPS. 350VA Eco Energy-Saving UPS System. Highlights. Description. Features

Internet Office 120V 600VA 300W Standby UPS, Ultra-Compact Desktop, USB

INSTALLATION MANUAL SLI 50 INVERTER

SmartPro LCD 120V 1.5kVA 900W Line-Interactive UPS, AVR, 2U Rack/Tower, LCD Display, USB, DB9 Serial

SmartPro 230V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

ECO Series 120V 850VA 425W Energy-Saving Standby UPS with USB, LCD Display and 12 Outlets

SmartPro 1.5kVA 1000W Line Interactive Sine Wave UPS, 2U Rack/Tower, LCD, USB, RS232, EPO, 120V

A+ Certification Guide. Chapter 1 Technician Essentials and PC Anatomy

Module 1. Introduction to A+ Form Factors, Cases, and Power Supplies

Omni LCD 650VA Tower Line-Interactive 120V UPS with LCD display and USB port

SmartPro 230V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD, USB, DB9 Serial

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

OmniSmart 1500VA 2U Rack/Tower Line-Interactive 120V UPS with LCD display and USB port

After completing this chapter, you will meet these objectives:

TAA-Compliant ECO Series 120V 550VA 300W Energy-Saving Standby UPS with USB monitoring and 8 Outlets

1 Interference from generator and lighting that could result in unclean power is known as. 3 Form factor of motherboard define its

Chapter 2 Motherboards and Processors

SmartPro UPS System Intelligent, line-interactive battery backup and network power management

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

EVGA assumes you have purchased all necessary parts needed to allow for proper system functionality.

850VA 480W Line-Interactive UPS with 6 C13 Outlets - AVR, 230V, C14 Inlet, LCD, USB, Tower

SmartPro 120V 1kVA 650W Line Interactive Sine Wave UPS, Tower, USB, DB9 Serial

About the Presentations

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

SmartPro LCD 120V 1300VA 720W Line-Interactive UPS, AVR, Tower, LCD Display, USB

OmniVS 120V 1500VA 940W Line-Interactive UPS, Extended Run, Tower, USB port

A+ Guide to Hardware: Managing, Maintaining, and Troubleshooting, 5e. Chapter 1 Introducing Hardware

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, USB, DB9 Serial

A+ Guide to Managing & Maintaining Your PC, 8th Edition. Chapter 13 Troubleshooting Hardware Problems

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

OmniVS 120V 1000VA 500W Line-Interactive UPS, Tower, USB port

User Manual Back-UPS BE650MC

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

Back-UPS RS APC Back-UPS RS 800VA 120V Black

BC Personal 120V 450VA 280W Standby UPS, Tower, USB port, 3 Outlets

SmartOnline Expandable Rack/Tower UPS System On-line, double-conversion protection for mission-critical applications

Chapter 1: Introduction to the Personal Computer

SmartPro UPS System Intelligent line interactive medical-grade battery backup and network power management

Chapter 6: Fundamental Laptops and Portable Devices

OmniVS 120V 1500VA 940W Line-Interactive UPS, Tower, USB port

SmartPro Tower UPS System Intelligent, line interactive network power management system

POS Series 120V 50/60Hz 500VA 300W Standby UPS, Tower, USB port, 6 Outlets, TEL/DSL Protection

SmartPro 120V 3kVA 2.88kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

Troubleshooting the System Hardware

Omni LCD 900VA Tower Line-Interactive 120V UPS with LCD display and USB port

SmartPro 120V 750VA 500W Line-Interactive Sine Wave UPS, Tower, SNMPWEBCARD Option, USB, DB9 Serial

TABLE OF CONTENTS 1. SAFETY PRECAUTIONS GENERAL DESCRIPTION FEATURES AND FUNCTIONS 4. CONNECTIONS 6. APPLICATIONS...

SmartPro 120V 1.5kVA 1.44kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, USB, 8 Outlets

(Hardware and case keys are provided inside the chassis storage compartment.)

OmniSmart LCD 120V 1500VA 810W Line-Interactive UPS, Tower, LCD display, USB port, Energy Star

TAA-Compliant OmniVS 120V 1000VA 500W Line-Interactive UPS, Tower, USB port

SmartPro 230V 3kVA 2.7kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

Model #: SMX1500SLT. SmartPro Tower UPS - Intelligent, line-interactive network power management system. Highlights. Description.

Transcription:

A+ Certification Guide Chapter 4 Power Supplies and System Cooling

Chapter 5 Objectives Power Supplies: Describe the device that transforms AC power from the wall outlet into DC power that your computer can use. Describe the various form factors and voltage levels, and how to protect your power supply. Power Protection Types: Describe devices that can protect your computer from voltage extremes. Troubleshooting Power Problems: Demonstrate how to troubleshoot complete failure and intermittent power supply problems that you might encounter. System Cooling: Describe the various ways to cool your system, including fans and liquid cooling, and demonstrate how to monitor the system temperature.

Power Converter Power Supply Unit (PSU) Power converter is a more accurate term. Converts AC 120v to DC 3.3v, 5v, and 12v as needed. PSU is important because: No power = no computing! Inconsistent/unpredictable power = Poor read/writes to hard drive Data corruption Video delivery problems System overheating Catastrophic failure Not normally repairable: Capacitors can cause serious injury. Easier/safer/less expensive to replace the whole PSU.

Power Converter Figure 4-1

How Much Power? Bigger the PSU rating = More expensive Too little power (overloaded) = Poor performance (lost or corrupt data) Spontaneous rebooting Overheating Figure 4-2

How Much Power? 1. Add up the total wattage of the devices attached to the system. 2. Divide the total wattage by.7. 3. Round up to the next wattage PSU available. Example: Assume your system uses 472 watts. 472 watts /.7 = 674 (That s point seven, not just seven.) Round up to 700 watts. PSU units are often sold in increments of 50 watts. In no case would you buy less than 674 watts. CAUTION: If you plan to add more devices, account for them: Hard drives, second DVD, and second graphics card.

Power Converter Back Panel PSU s capacity is rated in watts (volts x amps): European 240v versus North American 120v. Some units have an auto-detection feature. Must be set properly to avoid PSU failure.

Causes of Overheating Inadequate power supply wattage Failed fans: Inside PSU On CPU/GPU Inside the case Blockage of vents: Poor PC placement. Dirty vents intake or outtake Running in a room with high ambient temperature: Greater than 85 degrees poses a risk. Less than 75 degrees is recommended.

Power Supply Connectors From Power Supply to Motherboard: Large 20-pin or 24-pin ATX connector Drives: PATA and CD-ROM/DVD: Four-pin Molex power connector SATA: L-shaped thin-line power connector Floppy drive: Mini Molex connector. Fans: Case fans use Molex connector. Video cards PCI E x16 PCI Express six-pin power cable.

Power Connectors

PSU Replacement Checklist Same power supply connectors and the same pinout as the original. Same form factor (shape, size, and switch location). Same or higher wattage rating; a higher wattage rating is highly desirable. Support any special features required by your CPU, video card, and motherboard, such as SLI support.

Testing the Power Supply Multimeters are designed to perform electrical tests, including: DC voltage and polarity AC voltage and polarity Resistance (Ohms) Diodes Continuity Amperage Red lead: Attach to power source. Black lead: Attach to ground.

Testing the Motherboard Power

Multimeter Circuit Testing

Troubleshooting Power Supplies Overheating: Overloaded? Fan failure? Spontaneous rebooting: Incorrect voltage? Intermittent device failure: Particularly of bus-powered USB devices Loud noises: Fan failure imminent

Overheating Issues Overloaded PSU Fan Failure Inadequate Air Flow Outside the System (Room Temp) Inadequate Air Flow Inside the System Dirt and Dust

Troubleshooting Power Problems Sources of Problems: Defects in AC power to the system: Low voltage (<105v). Power supply failure or misconfiguration. Temporary short circuits in internal or external components: Disconnected CPU fan. Power supply or other component failure. Check for electrical smell from PSU First Step: Identify the Problem: Is the problem with the external power source, or is it inside the case with the PSU or some subsystem? Measure the source voltage. Is it >105 volts? Check the AC voltage switch on the power supply; it should be set to 115V for North America.

Troubleshooting Power Problems Check for a loose keyboard connector (could cause a short circuit). Open the system and check for loose screws or other components, such as loose slot covers, modem speakers, or other metal items that can cause a short circuit. Verify that the cable from the front-mounted power switch is properly connected. Check for blown fuses on the motherboard (mainly found in old systems). Remove all expansion cards and disconnect power to all drives: Restart the system, and use a multimeter to test power to the motherboard and expansion slots. Reinstall one card at a time and check the power: If the power tests within accepted limits, reattach one drive at a time and check the power. If a defective card or drive has a dead short, reattaching the defective card or drive should stop the system immediately upon power-up. Replace the card or drive and retest.

Power Protection Four problems often encountered: Overvoltages (spikes and surges) Undervoltages (brownouts) Power failure (blackouts) Noisy power (interference) Protection from these problems can be mitigated with: Surge suppressors, which are also referred to as surge protectors Battery backup systems, which are also referred to as UPS or SPS systems Power conditioning devices

Surge Protectors Power spikes: Very momentary. Can hit voltage levels in the thousands Power surges: Last longer than 1 second Lower voltage but potentially more damaging Surge protectors absorb extra voltage. Look for TVSS (transient voltage surge suppressor) rating Less than 400 volts High joule rating The more equipment plugged into it, the higher the joule rating needed. Fast response time. Warranty inclusion for lightning strikes.

Battery Backup Systems Note the presence of battery backup receptacles versus surge only Illustration: This is a pick up of Figure 5-13 from "CompTIA A+ 220-701 and 220-702 Cert Guide 2e (ISBN: 978-0-7897-4790- 7). Figure 4-17 04fig17

Battery Backup Systems UPS Versus SPS UPS = Uninterruptible Power Supply: Power always comes from the battery. Charger keeps the battery supplied with power. Heavier and more expensive. Better line conditioning. Longer computer equipment life. SPS = Standby Power Supply: Power comes from the facility power. Backup battery is employed only if the facility power fails. Most SPS are also surge suppressors. Note: Most SPS units in use are marketed as UPS units.

UPS What to Look For Run times: The time a computer will keep running on power from the UPS. Longer runtime unit uses a bigger battery and costs more. Fifteen minutes is a minimum recommendation for a UPS for an individual workstation. Servers have a longer shutdown time. Network support: Software can send a message to users about a shutdown so that users can save open files and close open applications. Shuts down the PC automatically before the battery runs down. Automatic shutdown: Essential for servers or other unattended units. The automatic shutdown feature requires an available USB port and appropriate software from the UPS maker. Surge suppression features: Look for Category A rating (UL-1449 and IEEE-587).

Correctly Sizing the UPS UPS is rated using volt-amps (VA): Larger VA enables longer runtime. Inadequate VA causes loss of data. Example: Multiply the power supply wattage x 1.4. Multiply the monitor wattage x 1.4. Add them together. This is the minimum size needed. Note: Doubling this number can triple the runtime. Pay attention to the outlets on the UPS. Many UPS units have both outlets that are on the battery backup system and outlets that are surge protected-only. Do not attach printers or unnecessary devices to the UPS outlets on battery backup systems. Reduces runtime significantly.

System Cooling Faster CPU = bigger PSU = more heat: Overheating causes component and system failure. Active versus passive cooling: Active: Use of powered device to move heat: Typically fans. Liquid cooling also available. Passive: Use of heat sinks to draw heat away: No moving parts never fails. Because active heat sinks are more effective, they are more useful on devices where more heat is generated. Downside: Any active device can be prone to fail. Newer passive devices use heat pipes to draw heat away from the onboard northbridge and southbridge chipsets.

Passive Versus Active Cooling

Case Fans Normally, at least two case fans: Front-side case fan draws air in. Rear case fan pushes air out. The PSU also has a fan that draws air out of the case and exhausts it near the top where most hot air migrates: Case fan sizes are typically 80mm to 120mm. Larger sizes can move more air with slower rotation: Less noise. Better cooling capacity. Newer case fans are temperature-sensitive: Adjust fan speed for inside case temperature.

BIOS Temperature Monitor

What Have You Learned? Write down three things that you did not know before this chapter discussion started. Suggest a troubleshooting scenario that would result from High voltage surge Blocked air vents Low facility voltage Failed CPU fan Poorly applied thermal compound

Chapter 4 Summary Power Supplies: Describe the device that transforms AC power from the wall outlet into DC power that your computer can use. Describe the various form factors and voltage levels, and how to protect your power supply. Power Protection Types: Describe devices that can protect your computer from voltage extremes. Troubleshooting Power Problems: Demonstrate how to troubleshoot complete failure and intermittent power supply problems that you might encounter. System Cooling Next Lesson: Chapter 5