DESCRIPTION. DataApex Clarity 32bit multi instrument chromatography station for Windows

Similar documents
Clarity. Clarity Demo. Code/Rev.: M003/60A Date: Fax: Petrzilkova 2583/ Prague 5

Clarity vs CSW32 Clarity vs CSW32

ChromQuest 5.0 Quick Reference Guide

HITACHI LACHROM ELITE

CLARITY DEMO. Clarity Demo Software. Code/Rev.: M003/70E Date:

Data Acquisition with CP-2002/2003 Micro-GC Control

UniPoint System Software User s Guide

C h r o m S t a r 7. M a n u a l

Chromatography Software Training Materials. Contents

EZ IQ. Chromatography Software PN P1A

Agilent ChemStation Plus

Agilent 68xx Agilent 68xx

U-PAD2 A/D CONVERTER

U-PAD A/D CONVERTER. Clarity Hardware. Code/Rev.: M059/80A Date: 6/6/2018

Chromatography Systems News Flash

INT7 A/D CONVERTER. Clarity Hardware. Code/Rev.: M058/80A Date: 6/6/2018

PDA EXTENSION. Clarity Extension. Code/Rev.: M054/80A Date: 6/8/2018. Fax: Petrzilkova 2583/ Prague 5

Retention Time Locking with the MSD Productivity ChemStation. Technical Overview. Introduction. When Should I Lock My Methods?

Galaxie Workstation Configuration Manager

Data Handling and Reports

Agilent ChemStation Plus

ERC REFRACTOMAX 520. Clarity Control Module. Code/Rev.: M190/70C Date: 8/23/2018

Technical Note. Introduction

TraceFinder Analysis Quick Reference Guide

EAS32 v.1.4 Costech International SpA

Tutorial EN

Agilent EZChrom Elite. User s Guide

COLIBRICK A/D CONVERTER

Chromeleon software orientation

Integrated Solutions. Automated Tablet Dissolution Testing with Agilent Chemstation HPLC. unique automated analytical solution for HPLC Analysis

Soprane II Documentation

TraceFinder Analysis Quick Reference Guide

SequencePro Data Analysis Application. User Guide

For additional information, see these documents on the Breeze 2 software DVD:

Standard Operating Procedure for the HPLC-ICP-MS System By Celina Dozier Fall 2017

Thermo Xcalibur Getting Started (Quantitative Analysis)

Using SIMDIS Expert 9 (Separation Systems) with Clarity

Impact Analysis for Software changes in OpenLAB CDS A.01.04

Agilent ChemStation. Understanding Your ChemStation

MULTICOM. Clarity Hardware. Code/Rev.: M110/80A Date: 8/15/2018. Fax: Petrzilkova 2583/ Prague 5

Application Note. This data also falls under FDA regulations for GLP and must comply with the guidelines for electronics records (21 CFR Part 11.

AEMLog Users Guide. Version 1.01

Procedures for Group Quantitation

Clarity Hardware. Duratec DDT 3200 USB. Code/Rev.: M064/24C 27 September 2006

FlowAccess TM GETTING STARTED. Windows software for Skalar SAN plus systems. Version and up

Galaxie Report Editor

What s New in Empower 3

Chromatography Data System

Spectrum 10 Spectroscopy Software

[ WHITE PAPER ] System Policies and Privileges for Processing Data in Empower Software with Data Integrity in Mind INTRODUCTION

Agilent ChemStation Plus. Specifications. February General Description

SICO-300 COLUMN OVEN

EZChrom Elite Chromatography Data System. Regulatory Compliance with FDA Rule of Electronic Records and Electronic Signatures (21 CFR Part 11)

Galaxie Photodiode Array Software

New features and Workflow Enhancements Empower 3 Software

Clarity Controls Clarity Controls Agilent 5890 Agilent 5890

StarFinder. Operation Manual. Star Chromatography Workstation Version 6

Agilent GC/MSD Instructions

Automated Submission for Analysis Processing (ASAP) Operator s Guide Dionex Corporation

The six versions are a single instrument Agilent. product number G2070AA, a single instrument Agilent. ChemStation for gas chromatography

Chromeleon-PA Analyzer User s Guide Dionex Corporation

R e p o r t E d i t o r M a n u a l

-Table of Contents- 1. Overview Installation and removal Operation Main menu Trend graph... 13

Data Acquisition with 3800 GC Control

Getting Started. Environmental Analysis Software

Agilent EZChrom Elite. PDA Analysis

AEMLog users guide V User Guide - Advanced Engine Management 2205 West 126 th st Hawthorne CA,

MagIC Net. Intelligent Software for Ion Chromatography

USB ph MONITOR. DataApex Clarity Control. Doc. #: DI Rev. A Praha, March 2013

DIAGNOSTICS PN# / / FSP

Agilent MassHunter Qualitative Data Analysis

Data Acquisition with 3400/3600 GC Control

MicroLab FTIR Software 21 CFR Part 11 Compliance

Quick Guide to the Star Bar

Batch Review Information CE, GC, LC and A/D ChemStation Revisions: A.05.0x - A.08.0x

ANALYTICAL SYSTEMS. L3320 Autosampler with excellent accuracy and linearity. System configuration examples

Agilent G2727AA LC/MS Data Browser Quick Start

OpenLynx User's Guide

Cal-Bay Systems XY Plotter, Time-Base Recorder, Automated Tester. Users Guide. Rev 3.1

Quick Start Guide. Introduction. Importing Raw Data. Method 1: Use Open Data Panel

Quick Start. Model 203 Single Channel PeakSimple Data System. STEP 2 (optional) STEP 4 STEP 5 STEP 1. STEP 3 (optional)

Pro Users Guide Pro Desktop Signmaking Software

Flexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC

This information applies to versions 2015 or greater of CODESOFT Enterprise Network Licenses.

C190-E092A Prominence Gel Permeation Chromatography System Shimadzu High Performance Liquid Chromatograph

ProMISE 2 user manual

ABB Analytical ABB Process Analytics. VistaII. Model 2000 Process Gas Chromatograph

831 KF Coulometer. Never before has coulometric Karl Fischer water determination been so economical!

The Portable Document Format (PDF) Converting word or Excel or PowerPoint to PDF PDF. PDF Save as Type. 5. When Finished Click at Save

TIDY LABELS. User Guide

Comply with Data Integrity Regulations with Chromeleon CDS Software

HydroOffice Diagrams

TraceFinder Administrator Quick Reference Guide

HT3X00A. Clarity Control Module. Code/Rev.: M153/50E Date: 11/13/2018. Fax: Petrzilkova 2583/ Prague 5

Instruction manual. testo easyemission Software

Software for Rheometers. RheoCompass

SHIMADZU LC-10/20 SYSTEM

Operating Manual. High Performance Liquid Chromatograph. Scientific Equipment Center, Prince Of Songkla University

Omnion 3.0 Software USER MANUAL. June 2006, Edition 3. Hach Company, All rights reserved. Printed in the U.S.A. te/dk

Steps for LCMS-8040 Triple Quadrupole

Transcription:

wwwdataapexcom e-mail: clarity@dataapexcom DESCRIPTION DataApex Clarity 32bit multi instrument chromatography station for Windows Multi-detector instruments Easy to install and easy to use Graphical user interface Tools for GLP and 21 CFR Part 11 Add on control modules On-line user support Excellent price/performance rate data solution for GC and LC systems

Support of Multi-Detector measurement Clarity is an advanced chromatography station designed to acquire and evaluate data from up to four chromatographs at a time Clarity - a top product in its category - represents a universal solution for laboratories It enables the user to acquire data from any commercially available chromatograph with standard analogue output Up to four chromatography systems, each of which can be equipped with up to four detectors, can be connected simultaneously The chromatography station package includes an A/D converter (internal PCI card or external USB box) and the corresponding Clarity Software wwwdataapexcom e-mail: clarity@dataapexcom OPERATING SYSTEMS The Clarity System has been developed and tested for use with 32-bit operating systems Microsoft Windows 98, ME, NT, 2000 and XP MULTITASKING Whilst acquiring data, you may work without problems on the evaluation and processing of already measured analyses or the preparation of parameters for subsequent analyses It is naturally possible to run other programs whilst working with the Clarity station SUPPORT FOR GLP/ 21 CFR PART 11 In recent years, chromatography practice has brought about not only the necessity of efficiency in laboratory work, but also new demands relating to monitoring and security mechanisms, particularly in the field of data managementthe Clarity supporting tools help you to comply with the requirements of GLP (Good Laboratory Practice) and FDA - 21 CFR Part 11 Data Security A system of access rights and passwords is set up within the station This system allows to create a unique password protected profile for each userthe user profile then defines in detail the user s rights within the station (eg authority to effect changes in the methods of measurement) and may limit ones access to only certain connected instruments Electronic signatures are also incorporated into the system so that a user may sign his or her data This electronic signature is stored with the name and date and supplemented with a set phrase (eg measured by, approved by, etc) Audit Trail Detailed logs and histories of modifications enable users to maintain an audit trail Clarity documents all parameters describing the conditions and methods of data processing for the userthis allows for easy access to a complete profile of information regarding any prior modification s performance Qualification Tools The Test IQ (Installation Qualification) is an integral component of the station This test monitors that the software has been properly installed and the results can be accessed from a printed protocol Clarity Validator for OQ (Operational Qualification) is an optional package available for testing and validating the Clarity chromatography stationthis is accomplished simply with the use of our chromatogram generator and a software utility

ClarityStation - simplicity and effectiveness Clarity has been developed with a special emphasis on simplification and improved intuition of use All frequently performed tasks are easily accessible thanks to the clear structure and intuitive graphical user interface Users will be able to work immediately, without detailed training WORKING WITH FILES A Quick View feature within an Open Chromatogram window displays the curve and the chromatogram headerthis helps the user easily navigate through previously saved chromatograms Recently opened chromatograms are easily re-accessed through a configurable recent files list Use Projects to structure your data and share it among other instruments Clarity stations can share data through the computer network LAYOUT The core windows of the station use splitters (dividing content within one window eg graphs and tables) and tabs so that all information is conveniently laid out and easily accessed CONFIGURATIONS Individual instruments are clearly, graphically configured in the Clarity station Each user may customize his or her desktop settings (colours, fonts, graph lines, size and location of windows etc) TABLES Tables throughout the entire station share the same basic behaviour However, users can adapt them to meet their requirements (width, visibility, column order and arrangement etc) All can be adjusted to meet specific needs Users can easily select available values of individual parameters from combo boxes Frequently used functions such as highlighted copying of tables, are immediately accessible in a local menu Data can be copied, not only among tables within the station, but also to other programs AUTOMATIC UPDATE Clarity enables you to use and display most files and results simultaneously at a number of places on the station All information is automatically updated everywhere it is used with each alteration This mechanism guarantees ultimate consistency and thus saves you the trouble of checking how current the data is USER SUPPORT Detailed help is available from any window of the Clarity station On-line support and access to the knowledge base is available free of charge data solution for GC and LC systems

Acquisition and evaluation of data Method and calibration files are the basis for acquisition and evaluation of chromatography data Clarity performs calculations of all common non-calibrated and calibrated results Instant response to a change of integration parameters or change in the calculation of results is definitely a great advantage ALGORITHM FOR DETECTION OF PEAKS Highly responsive algorithms enable users to detect hundreds of peaks in each chromatogram Data from the analysis can naturally be reprocessed without the necessity of repeating the analysis wwwdataapexcom e-mail: clarity@dataapexcom INTEGRATION All integration parameters are saved in the integration table Parameters such as Peak Width and Threshold are programmable in time There are a total of 27 integration parameters incorporated to ensure the optimal integration of peaks Most of these parameters can be applied also with the mouse from icons on the toolbar Every change of basic integration parameters in the chromatogram window will force immediate reintegration METHOD All parameters for data acquisition and peak integration, including baseline operations and link to the calibration file are saved in the template method After creating of a chromatogram, a copy of the template method becomes a part of the chromatogram file MULTI-DETECTOR MEASUREMENT Once a measurement has been completed within the framework of one instrument and more than one detector (up to four), signals are simultaneously displayed and accompanied by a legend identifying each signal and detector Users may select the number of signals displayed according to preference CALIBRATION The Clarity Station uses linked calibration Calibration curves are saved in a separate file, to which the template and chromatogram methods are referring After updating or modifying this calibration file, results in all chromatograms linked to this file will be automatically recalculated upon opening Although the calibration is linked, the current states of the calibration file and methods are stored in the chromatogram every time it is saved (using the commands Save, Print or Export) The chromatogram with its former method settings and calibration curves may thus be opened from any prior saved state CALIBRATION CALCULATIONS Clarity offers the ability to calculate using external or internal standard methods There are six types of curves to fit calibration points with the option to include a zero point The station allows you to select automatic or manual (interactive) method of data transmission from the calibration standard into the calibration file Groups of peaks may also be calibrated METHOD OF REFERENCE PEAKS Use reference peaks and or customizable identification windows for individual peaks to enhance the accuracy of compound identification EDITING AND RECALIBRATION Browsing and adjustment of calibration data is simple thanks to the consolidation of all compounds in a single global calibration table The calibration table and curve of each substance is placed separately on the relevant tab in the main calibration window

Results The Clarity chromatography station offers clearly presented results of obtained measurements Displayed chromatograms, result tables as well as any subsequent printouts can be configured by the user DISPLAY OF CHROMATOGRAMS Users can easily zoom in to any section of the chromatogramthe then zoomed area can be further enlarged, reduced or moved in an auxiliary preview window Return to the previous zoom using the commands Previous and Next Zoom The appearance of the graph may be selected from an inexhaustible number of variants (colour, enlargement, annotation, axis selection etc) Custom labels Text labels and lines can be attached to the chromatogram, and will automatically shift their position along with any movement of the chromatogram The displayed chromatogram always contains a legend with the names of the file and detector in the upper right corner of the graph DISPLAY OF MULTIPLE CHROMATOGRAMS When working simultaneously with several chromatograms (Overlay mode) it is possible to perform basic mathematical operations including shifting, changing scale, calculating difference in sums and derivationthree dimensional (3D) views for multiple chromatograms are also an option RESULTS OF ANALYSES The results of calibrated and non-calibrated analyses are shown as is common in analytical practice (height and area of peak, quantity of compound etc) The Clarity station also offers calculations of parameters describing the quality of the chromatography system (asymmetry, efficiency, etc) on the basis of three various methods of calculation The extended possibilities of these calculations are provided by the Clarity SST module, which is an optional component of the station SPECIAL CALCULATIONS The Clarity station implements a powerful tool for creating and composing your own columns and choosing its calculation If a station does not offer users a desired calculation, it can be easily created and defined Values of all columns of a given table can be combined using 12 predefined mathematical operators, 15 basic and 4 summary functions and several global variables SUMMARY TABLE The user-configurable summary table, displaying cross-sample data, presents a clear display of the resultsthe display of the summary table is highly configurable (display of individual parameters, orientation of lines and columns) PRINT PROTOCOLS The Clarity station supports printing of user defined protocols Its configuration is saved in report style, which defines the content and form of the printout Pick from the predefined report styles or adjust them and store for further use Different report styles can be predefined according to the dialog in which you are working You can review the printout on the screen in the print preview For printing protocols from multiple analyses users can either use batch processing of data or print a summary table IMPORT AND EXPORT Clarity data is backward compatible with data of the CSW17 and CSW32 stations It is also possible to import and export ASCII text and AIA data formats into/from Clarity The results may also be exported to dbase format data solution for GC and LC systems

Automation, Sequence Connecting the Clarity station to chromatographs with autosamplers enables you to process data quickly and effectively, including automatic printing of results Results are printed automatically and cross-samples are clearly presented in the summary table Unattended sequence operation saves you time SEQUENCE - SYNCHRONISATION WITH AUTOSAMPLERS The Clarity station supports synchronisation with practically any type of autosampler without the need to install a control module Work is possible using both an active (activity controlled by the Clarity station) and passive sequence (activity controlled by autosampler) Each sample in the sequence can be processed according to a different method Certain samples can be marked as calibration standards so that they can be automatically used in the calibration or recalibrationthis is especially helpful in larger sequences to maintain precision of the measurement The ability to pause and modify a running sequence makes for great flexibility when working with sequence tables The sequence file contains an audit trail, which records all events related to measurement With direct control via the AS control module users can select his or her own method of injection, including selecting the order of vials wwwdataapexcom e-mail: clarity@dataapexcom BATCH PROCESSING OF CHROMATOGRAPHY DATA The station offers tools for batch reprocessing of data (Batch), which users can employ in cases where it is necessary to identically process large amounts of analyses or to print out the results of several analyses simultaneously POSTRUN FUNCTIONS The Clarity station allows automated performance of routine operations following processing of data from each analysis A processed chromatogram may be automatically displayed in the evaluation or calibration window, printed and results exported It is also possible to define the activation of another program, which may further process the acquired data Postrun functions can be applied after batch processing of data, sequences or single analyses ARCHIVING DATA The station provides simple tools for backup and restore of chromatography data Backup can be defined on the level of whole Projects involving a large number of analyses

Add on modules and extensions The basic Clarity station can be extended with add-on software modules: System Suitability Test - SST and control modules for autosamplers, gas chromatographs or HPLC pumps Drivers for instruments from selected manufacturers, the list of which is constantly extended according to user requirements, are also available SST - SYSTEM SUITABILITY TEST The SST module serves to monitor the correct function of the chromatography system The program compares up to 12 selected parameters (eg retention time, efficiency, asymmetry of peaks) calculated according to one of three pre-selected methods (USP, EP, JP) These calculated values are compared to user set limit values, either for each chromatogram separately or together for the selected series Deviation of a certain parameter from the permissible limits is immediately reported and may lead to the termination of the sequence in progress The SST module enables you to monitor the parameters of individual substances and thus to evaluate the reproducibility of the results of the entire chromatography system CLARITY EVALUATION STATION The Clarity Evaluation Station is available when evaluating data or preparing methods for measurement on another computer than that on which the measurement is taking place This special version of software makes use of all functions except for data acquisition and has the same output as the Clarity station This program uses a protective key located in the printer or USB port of the computer DIRECT CONTROL OF GC CHROMATOGRAPHS The GC control module contains means for the complete control of selected types of gas chromatographs You can easily set the parameters of the chromatograph from your computer (eg temperature program of oven or inlet, pressure program, etc) The whole description of the GC method is again stored together with the data of the analysis and can be displayed or printed at any time The GC monitoring window for given types of gas chromatographs clearly displays both the current and required value of the individual parameters DIRECT CONTROL OF LC PUMPS In the field of LC chromatography, Clarity primarily provides control of pumps Clarity Instruments can create the LC gradient from up to four independent pumps for each instrument simultaneously The created control method is saved in the chromatogram file Intelligent pumps are controlled over the serial interface RS 232 Simpler types, driven by voltage or frequency, are controlled using the dedicated PCI computer CB20 cards DIRECT CONTROL OF AUTOSAMPLERS Control of autosamplers enables Clarity to ensure complete automation services for your laboratory The chromatography station provides you with access to all parameters of the injection methods directly from your computer and allows you to determine the order of individual vials data solution for GC and LC systems

Summary of HW The hardware supplied together with the Clarity station has been developed by the DataApex company Choosing between an internal PCI or external USB A/D converter is up to the user The Clarity chromatography station can handle any combination of available DataApex converters DataApex provides a 3-year guarantee on its own hardware wwwdataapexcom e-mail: clarity@dataapexcom The DataApex company reserves the right to make changes to products without giving prior notice Clarity TM is a registered trademark of the DataApex company Microsoft Windows is a registered trademark of the Microsoft company 2003 DataApex, Rev 01-2003 INT7 INTERNAL PCI A/D CONVERTER The INT7 is an internal PCI 24-bit A/D card designed for data acquisition from detectors with standard analogue outputthe card is designed for PCI slots and equipped with a "Plug and Play" system, which provides you with easier installation under the current versions of OS WindowsThe INT7 card contains one to four independent channels on one basic cardthe channels are mutually isolated with symmetrical inputs INT7 is distinguished by its excellent temperature stability U-PAD - EXTERNAL USB A/D CONVERTER The U-PAD is an external measuring unit for acquisition of data from detectors with standard analog output U-PAD uses a USB communication channel, which allows direct connection from the PC U-PAD represents an ideal solution for connecting chromatographs to a laptop computerthe unit contains two independent channels equipped with the latest 24-bit A/D converters, which attain higher effective resolution, particularly at higher integration frequencies and lower voltage rangesthe channels are isolated with symmetrical inputsthe input connector is compatible with the internal INT7 card INT7 (PCI internal) A/D converter U-PAD (USB external) A/D converter Resolution 24-bit 24-bit Number of channels 1-4 2 Voltage ranges bipolar: 156, 1 250, 10 000 mv bipolar: 156, 1 250, 12 585 mv Integration frequency up to 100 Hz up to 100 Hz Auxiliary inputs/outputs 4/8 2/2 CB20 - INTERNAL PCI D/A AND D/F CONVERTER The control card CB20 contains four 16-bit D/A converters and four 28-bit frequency converters and is designated for control of analog and frequency controlled pumps (eg Waters pumps)the card does not contain any setting jumpers It is sufficient to install only the relevant driver and set the constants corresponding to your pumps due to the "Plug and Play" technology of the card