Dielectric Withstand and Ground Bond Testers

Similar documents
Hypot III. Graphic Liquid Crystal Display. 10 Memories with 3 Steps per Memory. Low Limit Detection System. SmartGFI Circuit (Patent Pending)

Fully-Automated Multi-Function Electrical Safety Compliance Analyzers

Fully-Automated, Multi-Functional Electrical Safety Compliance Analyzers

Features and Benefits

OPERATION AND SERVICE MANUAL. Hypot III

OPERATION AND SERVICE MANUAL. HypotMAX

OPERATION AND SERVICE MANUAL. Hypot III

OPERATION AND SERVICE MANUAL. MODEL 8104 OMNIA 4 MODEL 8105 OMNIA 5 MODEL 8106 OMNIA 6 Electrical Safety Compliance Analyzer

HYPOT III. Quick Start Guide

OPERATION AND SERVICE MANUAL. MODEL 7620 HypotULTRA III MODEL 7650 HypotULTRA III Electrical Safety Compliance Analyzer

ClareHAL 104 Electrical Safety Tester

OPERATION AND SERVICE MANUAL. HypotPLUS

OPERATION AND SERVICE MANUAL

USER MANUAL S6000 / S7000 S8000 / S9000. Associated Research, Inc., West Laurel Drive Lake Forest, Illinois, U.S.A.

HYAMP. Quick Start Guide

Advanced Test Equipment Rentals ATEC (2832)

SC6540. Quick Start Guide

Application Note. Use of Palm Switches with QuadTech Hipot Testers

OPERATION AND SERVICE MANUAL

High Voltage Power Supplies

Model 4500D. Hypot II. MODEL 4500D 500 VA Enhanced AC Only Hipot With Ground Continuity Check OPERATION AND SERVICE MANUAL SERIAL NUMBER

2200 Series. Quick Start Guide SAFETY CHECKLIST. Safety Made Simple

PAT-Cal 2 TECHNICAL MANUAL

MOTOR ARMATURE TESTER

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

OPERATION AND SERVICE MANUAL

Please use the Q & A utility to ask us any questions concerning the material being presented.

Models 6522, 6524, 6526, 6532, 6534 & 6536

OPERATION AND SERVICE MANUAL. Model 2955, 2965, 2975

OPERATION AND SERVICE MANUAL

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

OPERATION AND SERVICE MANUAL. Model 2925, 2935, 2945

LOW WEIGHT, SMALL SIZE,

The new Clare HAL Series. Keeping electrical products safe. Experts in what we do.

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

IRM-5000P. insulation resistance meter. Vanguard Instruments Company, Inc.

Testing Instruments Manufactured by

Modular Power System 1200 W per mainframe GPIB

The new ClareHAL Series. Keeping electrical products safe.

SE Series Electrical Safety Analyzer Operation Manual

SureTest Model ST 1D Instructions

Model SC6540 MODEL SC6540. High Voltage and High Current Scanning Matrix OPERATION AND SERVICE MANUAL SERIAL NUMBER

ELECTROM INSTRUMENTS

6000 Series. Automated AC Power Source Operation Manual for Models Ver PART # 38923

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Technical Hotline: (800)

Circuit Breaker Analyzer & Timer CAT66

5000V Digital/Analog Megohmmeter Model 5060

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

944i Dielectric Analyzer

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT126

10A Micro-Ohmmeter Model 6240

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

Micro-Ohmmeter. Digital 200A. Model Measure low resistance with high accuracy

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Guardian 5000 AC/DC/IR/GC Safety Analyzer Instruction Manual Form /B3

Powerstar PS3204rm2u True online 2KVA /1800W (19.7 deep)

UH28C. High Voltage Tester. Product Information Sheet V AC / 100 ma

MAJOR VA Power Inverter

3A SERIES MODULAR AC & DC LOADS

GCT-9040 AC Ground Bond Tester New Product Announcement

5000V Digital/Analog Megohmmeter. Models 5050 & 5060

Programmable DC Power Supplies XLN Series

RT4F-110V/25A RECTIFIER

Universal AC Power Source + AC Power Analyzer

AIM & THURLBY THANDAR INSTRUMENTS

AIM & THURLBY THANDAR INSTRUMENTS

MOTOR STATOR TESTER ENGLISH MANUAL. 2 st Oct 2009 V1.1Version

3156 LEAK CURRENT HiTESTER

EC Declaration of Conformity

VS Series 120V 600VA 300W Line-Interactive Desktop UPS, Tower, 6 Outlets

Programmable DC power supplies

HI-POT TESTER User Manual

THURLBY THANDAR INSTRUMENTS. PL & PL-P Series. Laboratory Power Supplies. Standard and Programmable models, 35 watts to 240 watts

CT-6500 S2. digital circuit breaker analyzer. Vanguard Instruments Company, Inc.

HI-POT TESTER. User s Manual

RT4F-48V/50A-WAC RECTIFIER

Model R5010. TRMS Digital Multimeter. Instruction Manual

Medical Device Testing Explained

RT4B-110V/12A RECTIFIER

Agilent 66000A 1200 W DC Modular Power System, GPIB

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

DP700 Series. Programmable Linear DC Power Supply. Batter Fly s.r.l. - Tel

OPERATION AND SERVICE MANUAL. Model 1305, 1340 MODEL 1305 (AC ONLY HIPOT) MODEL 1340 (100VA AC ONLY HIPOT WITH OPTIONAL GROUND CONTINUITY CHECK)

Electrical Safety Tester

Advanced Test Equipment Rentals ATEC (2832)

PROFITEST 204 For testing the safety of electrical machinery equipment

Micro-Ohmmeter. Digital 200A. Model Measure low resistance with high accuracy

OPERATION AND SERVICE MANUAL MODEL SC6540. High Voltage and High Current Scanning Matrix SERIAL NUMBER. Item Ver 3.12

Single-Output 2000 W GPIB

RT4F-120V/20A-WAC RECTIFIER

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

Tri-Phase. true 3-phase transformer turns ratio tester

CT-7500 S2. Advanced Test Equipment Rentals ATEC (2832) digital circuit breaker analyzer

Circuit Breaker Analyzer & Timer CAT126

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

CT-8000 S3. digital circuit breaker analyzer

OmniSmart 120V 330VA 225W UL Medical Grade Line-Interactive UPS, Tower, DB9 Serial

Mini Digital Multimeter

CT-8000 S3 digital circuit breaker analyzer

Transcription:

Dielectric Withstand and Ground Bond Testers For Safety Agency Production Line Compliance Testing U.S. patent#: 5,548,501, 6,054,865. Other patents pending. Safety agency listed.

ENHANCED GRAPHIC LCD The enhanced graphic liquid crystal display on the Hypot III and the HYAMP III provides the operator with complete test setup and results in an easy-to-use interface. The graphic LCD makes testing safer, easier and more reliable than ever before. (Above display is shown at actual size.) Clear test parameters can be displayed on a single screen Configurable test result screen can be set up to show detailed test results The test result screen can be set up to show a simple PASS/FAIL indication. INTERCONNECT CAPABILITIES A COMPLETE MID-RANGE SYSTEM TO MEET THE MOST COMMON ELECTRICAL SAFETY COMPLIANCE TESTS With its 2U 1/2 rack mount cabinet design the Hypot III family of products can be interconnected to the HYAMP III, model 3130 Ground Bond tester that is also designed in a 2U 1/2 rack mount style cabinet. These two instruments can then be rack mounted side by side in a single 19 2U rack space. The interconnect capability of these two instruments also provides a single DUT connection and automates the test sequence or sequences chosen by the operator such as AC Hipot, DC Hipot, IR test and Ground Bond test.

USER-FRIENDLY FEATURES Tamper Proof Front Panel Controls To Limit User Access User Selectable Output Voltage & Frequency Complete User Configurable System Capability Built-In Security Settings Multiple Test Memories & Steps Electronic Dwell Setting No Load Setup Of Voltage Current Minimum & Maximum Trip Settings NEW TO HYPOT III & HYAMP III FEATURE Enhanced graphic LCD BENEFIT The enhanced graphic LCD provides the operator with an advanced user-interface. This backlit graphic display makes viewing and interpreting test results and data easier than ever before. The LCD can display text and symbols eliminating the need to decipher abbreviations. FEATURE Built-in VERI-CHEK self verification system BENEFIT Regular verification is required by some agencies to validate that the instrument is functioning correctly. The VERI-CHEK feature, by prompting the user through the correct steps, allows for quick and easy validation. This built-in feature eliminates the additional cost of having to purchase an external box for verification. FEATURE Remote Safety Interlock BENEFIT The Remote Safety Interlock prevents the high voltage from being activated without the interlock enabled. The interlock works as a safety feature by using a set of contacts to enable or disable the instrument s high voltage output. If the interlock contacts open during a test the high voltage output is shut down. FEATURE Built-in CAL-ALERT function BENEFIT This feature automatically alerts the user when the instrument is due for re-calibration. This eliminates the need for manual tracking of calibration dates. NEW TO HYPOT III FEATURE Exclusive SmartGFI function BENEFIT The patent pending SmartGFI provides maximum operator protection to the user. If the circuit detects excessive leakage to the ground it shuts down the high voltage in less than 1 millisecond. SmartGFI is automatically activated if the DUT is not grounded so that the operator does not need to make the decision whether to activate the SmartGFI. FEATURE Max output current 20 ma AC and 7.5 ma DC BENEFIT Hypot III is a true hipot tester with enough output current to test capacitive loads in AC mode and allows the instrument to comply with the UL 120 K ohm requirements. FEATURE Switchable Floating and Grounded Return BENEFIT This feature is included within the software of the instrument. The instrument automatically detects if the DUT is floating or connected to Earth Ground. If the DUT is grounded the smart GFI circuit turns off the GFI detector. If the DUT is floating the GFI circuit is enabled. FEATURE Digitally controlled arc detection system BENEFIT The arc detection system allows the operator to select whether low-level arcs should be detected and provides the operator with the ability to digitally select and program multiple sensitivity levels. FEATURE Built-in adjustable Continuity test mode BENEFIT Hypot III meets ground continuity test requirements called out by UL and other safety agencies. FEATURE Electronic ramping (up & down) BENEFIT Electronic ramping provides a gradual and timed method to increase or decrease output voltage to the DUT effectively minimizing any damage from quick high voltage changes to sensitive DUTs. FEATURE Resistance Range of 1-9999 MΩ BENEFIT Model 3670 AC/DC/IR includes an increased maximum resistance limit, which will allow for increased resistance measurement of the insulation of a DUT.

HYPOT III SPECIFICATIONS Models 3605 AC, 3665 AC/DC and 3670 AC/DC/IR INPUT VOLTAGE 115/230 V selectable ± 10% variation FREQUENCY 50-60 Hz ± 5% FUSE 115 VAC, 230 VAC - 3.15 A fast acting 250 VAC DIELECTRIC WITHSTAND TEST MODE Rating: AC 0-5000 V, 20 ma DC 0-6000 V, 7.5 ma Regulation: ± (1% of output + 5 V) VOLTAGE Rating: 0 V - Max output rating, 10 V/step Accuracy: ± (2% of setting + 5 V) (relative to displayed output) Can be adjusted during operation via UP and DOWN arrow keys. AC models: 50/60 Hz selectable FREQUENCY AC & DC models: DC and 50/60 Hz selectable WAVE FORM Sine wave Distortion: < 2% THD RIPPLE 5% at 6 KV DC/7.5 ma, Resistive Load DWELL TIME AC: 0 and 0.3-999.9 secs, 0.1 sec/step DC: 0 and 0.4-999.9 secs (0 = Constant) RAMP TIMER Range: Ramp-Up: 0.1-999.9 sec Ramp-Down: AC 0.0-999.9 sec DC 1.0-999.9 sec 0=OFF Resolution: 0.1 sec FAILURE AC Max. Limit: 0.00-20.00 ma, 0.01 ma/step S Min. Limit: 0.0-9.999 ma, 0.001 ma/step (0 = OFF) Accuracy: ± (2% of setting + 2.0 ma) DC Max. Limit: 0.00-7.50 ma, 0.001 ma/step Min. Limit: 0.0-999.9 µa, 0.0001 ma/step (0 = OFF) Accuracy: ± (2% of setting + 2 ma) DISCHARGE TIME 200 ms The maximum capacitive load vs. output voltage: 0.20 µf < 1 KV 0.050 µf < 4 KV 0.10 µf < 2 KV 0.040 µf < 5 KV 0.06 µf < 3 KV 0.015 µf < 6 KV VOLTAGE Range: 0.00-5.00 KV AC 0.00-6.00 KV DC Resolution: 0.01 KV Accuracy: ± (2% of reading + 0.01 KV) CURRENT Auto Range AC Range 1: 0.000 ma - 3.500 ma Resolution: 0.001 ma Range 2: 3.00-20.00 Resolution: 0.01 ma DC Range 1: 0.0 µa - 350.0 µa Resolution: 0.1 µa Range 2: 0.300 ma - 3.500 ma Resolution: 0.001 ma Range 3: 3.00 ma - 7.50 ma Resolution: 0.01 ma ACCURACY All Ranges: ± (2% of reading + 2 counts) TIMER Range: 0.0-999.9 secs Resolution: 0.1 sec Accuracy: (0.1% of reading + 0.05 secs) GROUND Current: DC 0.1 A ± 0.01 A, fixed CONTINUITY CHECK Resistance: 0.01 Ω - to 1.50 Ω GROUND GFI Trip Current: 450 µa max (AC or DC) FAULT INTERRUPT HV Shut Down Speed: < 1 ms INSULATION RESISTANCE TEST MODE (Model 3670) VOLTAGE Range: 30-1000 V DC Resolution: 1 V Accuracy: ± (2% of reading + 5 V) RESISTANCE Range: 1-9999 MΩ (4 Digit, Auto Ranging) Resolution: 500 V DC - 100 V DC MΩ MΩ 0.001 1.000-9.999 0.01 10.00-99.99 0.1 100.0-999.9 1 1000-9999 Accuracy: ± (2% of reading + 2 counts) at test voltage 500-1000 V and 1-999.9 MΩ ± (5% of reading + 2 counts) at test voltage 500-1000 V and 1000 Ω - 9999 MΩ ± (8% of reading + 2 counts) at test voltage 30-500 V and 1-1000 MΩ IR VOLTAGE Range: 0-1000 V Resolution: 1 V/step Accuracy: ± (2% of reading + 2 V) MAXIMUM RESISTANCE LIMIT Range: 0,1-9999 MΩ (0 = OFF) MINIMUM RESISTANCE LIMIT Range: 1-9999 MΩ IR DELAY Range: 0, 0.5-999.9 sec (0 = Constant) Resolution: 0.1 sec/step Accuracy: ± (0.1% + 0.05 sec) GROUND GFI Trip Current: 450 µa max FAULT INTERRUPT HV Shut Down Speed: < 1 ms REMOTE CONTROL & SIGNAL PROGRAM MEMORY SECURITY BUZZER LINE CORD TERMINATIONS GENERAL SPECIFICATIONS The following input and output signals are provided through two 9 pin D type connectors: 1. Test, Reset, and Remote Interlock 2. Remote recall of memory program #1, #2 & #3 3. Outputs: Pass, Fail, Test-in-Process, & Reset. 10 Sets 3 steps per set-up with ability to link tests in any order. Lockout capability to avoid unauthorized access to test set-up program. 128 x 64 dot resolution with front panel contrast setting. Alarm with volume control. Detachable 7 ft. (2.13 m) power cable terminated in a three prong grounding plug. Detachable 5ft. (1.52 m) high voltage and return leads (2) with clips and a standard U.S. style (NEMA 5-15) remote receptacle box for testing items terminated with a line cord. International receptacles also available. Front and Rear outputs standard. MECHANICAL Tilt up front feet. 2U 1/2 rack. Dimensions: 8.5 x 3.5 x 14.5 inches (215 x 89 x 370 mm) Weight: approx. 22 lbs. (10 kgs) ENVIRONMENTAL Operating Temperature: 32-104 F (0-40 C) Relative Humidity: 0 to 80% CALIBRATION Traceable to National Institute of Standards and Technology (NIST). Calibration controlled by software. Adjustments are made through front panel keypad in a restricted access calibration mode. Calibration information stored in nonvolatile memory.

HYAMP III SPECIFICATIONS Model 3130 Ground Bond Tester INPUT VOLTAGE GROUND BOND TEST MODE 115/230V selectable, ± 10% variation 50/60 Hz, ± 5% GENERAL SPECIFICATIONS VERIFICATION Built-in software driven verification SYSTEM menu to test fault detection circuits. FUSE 6.3 A fast blow 250 VAC Current: AC 1-30 A, 0.01 A/step Regulation: ± (2% of setting + 0.02 A) Voltage: AC 6 V fixed REMOTE CONTROL & SIGNAL The following input and output signals are provide through two 9 pin D type connectors; 1. Remote control: Test, Reset, Interlock and Withstand Processing FREQUENCY 50/60 Hz selectable PROGRAM MEMORY 2. Outputs: Pass, Fail, Test in Process, Start Out, and Reset Out 10 Memories, 3 Steps per memory. DWELL TIME FAILURE S 0 and 0.5-999.9 secs, 0.1 sec/step 0 for continuous running Accuracy: ± (0.1% of setting + 0.05 secs) Max. limit: 0-120 mω for 1-30 A, 1 mω/step 0-510 mω for 1-10 A, 1 mω/step Accuracy: ± (2% of setting + 2 mω) SECURITY LINE CORD Key Lock capability to avoid unauthorized access to all test parameters. Memory Lock capability to avoid unauthorized access to Memory locations. Detachable 7 ft. (2.13m) power cable terminated in a three prong grounding plug. MILLIOHM OFFSET METERING Min. limit: 0-120 mω for 1-30 A, 1 mω/step 0-510 mω for 1-10 A, 1 mω/step Accuracy: ± (2% of setting + 2 mω) Offset Capability: 0-100 mω, 1 mω/step Accuracy: ± (2% of setting + 2 mω) Ammeter (3 digits) Range: 0-30 A Resolution: 0.01 A/step Accuracy: ± (3% of reading + 0.03 A) Ohmmeter (3 digits) Range: 0-510 mω Resolution: 1 mω/step Accuracy: ± (2% of reading + 2 mω) ALARM VOLUME CALIBRATION MECHANICAL 128 x 64 dot resolution with front panel contrast setting. Front panel adjustable volume setting with 10 set points. Traceable to National Institute of Standards and Technology (NIST). Calibration controlled by software. Adjustments are made through front panel keypad in a restricted access calibration mode. Calibration information stored in nonvolatile memory. Tilt up front feet. 2U 1/2 rack. Dimensions: 8.5 x 3.5 x 14.5 inches (215 x 89 x 370 mm) ACCESSORIES ACCESSORIES: Timer (4 digits) Range: 0-999.9 secs Resolution: 0.1 secs/step Accuracy: ± (0.1% of reading + 0.05 secs) Weight: 19.65 lbs. (8.9 Kgs) ENVIRONMENTAL Operating Temperature: (0-40 C) Relative Humidity - 0 to 80% Unless otherwise stated, accuracies are relative to a laboratory standard measurement. Rack Mount Kit Connects the instruments & provides the necessary flanges for mounting the system into a 19 rack. 38321 Resistor Kit Precision 1% resistor is ideal as a load to set current trip points. Meets 120 k ohm requirements. 35534 Black Stationary Probe Provides an insulated fixed metallic contact point to a DUT for a return path. 35539 Foot Switch Ideal for applications where an operator needs to start a test hands off the instrument. 35822 Retractable Probe High voltage retractable 5 KV AC probe for safe testing & application of high voltage. 38081 Retractable Return Probe This retractable probe is used on the return side of the Hypot III. 38082 Safe-T-Probe Test gun with trigger that controls retractable probe & activates instruments high voltage circuit. 38083 Adjustable Resistor Bank Provides test loads from 120 K to 2.148 k ohms. 6 terminals with 12 settings. Helps verify regulation. 36956 Interface Kit Includes cables & adapter box so multiple tests can be performed through a single DUT. 260-01

The Industry s Most Complete Line of Instruments for Electrical Safety Compliance Testing State-Of-The-Art Electrical Safety Compliance Testing Instruments The first fully-automated, multi-function Electrical Safety Compliance Analyzer with an enhanced graphic LCD. OMNIA provides 4-in-1, 5-in-1 and 6-in-1 models that include AC Hipot, DC Hipot, Insulation Resistance, Ground Bond, Functional Run and Line Leakage testing. All models available with IEEE-488 (GPIB), RS-232 or printer interface. Knowledgeable Customer Support And Expert Technical Services At 1-800-858-TEST Software designed to store, analyze and retrieve data on automated Associated Research instruments, while performing Line Leakage, Insulation Resistance, Dielectric Withstand, Ground Bond and Functional Run tests. Autoware also allows for bar coding inputs and provides basic statistical analysis graphs. NEW! Multi-function electrical safety tester with an enhanced graphic LCD. Models include the 7620, AC Hipot tester and the 7650, AC/DC/IR tester. Both models include an optional 4-port or 8-port built-in switching matrix and are available with IEEE-488 (GPIB), RS-232 or printer interface. Guaranteed Product Satisfaction And A 5-Year Extended Product Warranty* *With Annual Calibration from Associated Research 24-Hour Turn-Around On All Instrument Calibrations 4-in-1 Electrical Safety Compliance Analyzers include AC/DC Hipot, Insulation Resistance, Ground Bond tester and optional built-in switching matrix in a single instrument. Complete with IEEE-488 (GPIB), RS-232 or printer interface. Available in 500 VA output versions. SWITCHING MATRIX The HS-8A is an 8 channel and the HS-16 is a 16 channel matrix. Both models are high voltage and high current matrices for multi-point or multiproduct testing. (For use with QUADCHEK II, HypotULTRA III or OMNIA ) The first semi-automated microprocessor controlled Dielectric Withstand testers available in AC or AC/DC versions. All models include enhanced PLC control, remote memory recall, advanced failure detection systems. Available optional 10 V analog signal and real current. Catalog # HYPOT III 1/03 Designed to automate line leakage testing in production line or lab environments. The 510L is a stand-alone system and the 520L can interconnect with other AR safety testers to form a complete automated testing system. The 905D functional run test system powers and runs a product while measuring current, voltage, power factor and watts. It can be interconnected to our safety testers so all tests can be performed through a single DUT connection. Available with standard GPIB or RS-232 interface. 30 Amp Ground Bond tester that works as a stand-alone instrument or can be interconnected to the HypotPLUS II to form a semi-automated test system with a single DUT connection. Informative Industry Seminars, Professional Training And Educational Programs Local Sales Offices Throughout The World To Serve You More Efficiently 13860 West Laurel Dr. Lake Forest, IL U.S.A. 60045-4546 Tel: 847-367-4077 Fax: 847-367-4080 E-mail: info@asresearch.com For more information visit our web site at: www.asresearch.com and ORDER ON-LINE! Or contact us toll-free at: 1-800-858-TEST(8378)