HI 6600 series Quick Start Guide

Similar documents
HI 6600 series Quick Start Guide

HI 6500 series Quick Start Guide

HI 1734-WS Quick Start Guide

Hardy HI 2080 EASY 8 Quick Start & Programming Guide

Hardy EASY 8 Quick Start & Programming Guide. Function Block Description

HI 6600 Series Modular Sensor System

M260 Load Cell Amplifiers

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

EQ7000. User Manual. Rev 1.00

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Pennsylvania Scale Company Model 400B Battery Powered Digital Indicator Operation & Calibration Manual

# Byrne Rd, Burnaby, BC, V5J 3J1, Canada Phone: or

PACSystems* RSTi-EP EPSCPE100 Enhanced performance standalone controller for RSTi-EP Platform CPU Quick Start Guide

Characteristics and functioning

IPM650 Intelligent Panel-Mount Display

Characteristics and functioning

Weight Processor. HI 6300 Series. User s Guide. Hardy Process Solutions Document Number: REV B

enod4 Weighing controller for automated systems

9120 Redundant Probe System (RPSC)

I/O Expansion Module Installation & Reference

ETHERNET/MFC 010 Technical Datasheet

EnerSure Installation Guide

CALIBRATION HI 2151/30 TRADITIONAL HARD CALIBRATION. Mode kg. Cal

BAS Router BACnet Multi-Network Router

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

CALOG CALOG - LC DISPLAY. Loadcell Display. English Users Manual. Rev. 1.10

Using the Multi-channel Display Feature of the Hardy 6000 Series

1. Installation. 2. Configuration - Operation. 3. Specifications. Safety

PS-IN202 Weighing Indicator User Manual

RTU560 Remote Terminal Unit Connections and Settings

DCS Series. Digital Counting Scale. Setup Manual

ROCKETLINX ES8508 ES8508 ES8508F ES8508-XT ES8508F-XT QUICK INSTALLATION GUIDE

Analogue Signal Transmitter AST 3 From prog.name A001A140. Operating instructions, Quick installation

DUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

Installation and Configuration Guide

C500 Series Data Sheet

Modbus Communications Board

Optima OP-900-LD Score Board Indicator (with Remote Control) User Manual

FP-2000/2010 FieldPoint Quick Start Guide

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

Reference Manual. SAI Standard Automation Interface

Keep all manuals as a product component during the life span of the product. Pass all manuals to future users / owners of the product.

PACSystems* RSTi-EP EPSCPE100 Enhanced performance standalone controller for RSTi-EP Platform CPU Quick Start Guide

SmartRail I/O Ethernet Base HE599ETX300

Cascade Sensor Installation Guide. Version 8.2 March 2009

8 channel Ethernet to analog interface. Web Server Configuration Manual

Output Interfaces for SVS2000 TM Installation & Operation Manual

LC0 DVP

MOD-MUX MODBUS TCP I/O PRODUCTS

60 Series EtherNet/IP Option. Configuration Manual Revision A

Transmitter WST 3 From prog. name W001A100. Technical Manual

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel

Ethernet HMi RAC and Gateway Setup Instructions Rev. 09

D-100 FLOW DISPLAY MODBUS Network Interface Installation Guide

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

Honeywell HC-900 with Acromag 967EN Modbus/TCP Module as Remote I/O

MAGUIRE G2-ES Configuration Instructions for Ethernet to Serial Converter Model: Moxa NPort 5110 Serial Device Server

Safety. 2. Configuration - Operation 2.1 RTD Selection 2.2 Driver Test Header. 3. Diagnostics 3.1 ph Input 3.2 Temperature Input

Weight Processor. HI 6500 Series. User s Guide. Hardy Process Solutions Document Number: REV C

Industrial Serial Device Server

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

Network Video Recorder Quick Operation Guide

HRM-0800 Instruction Manual

MGate MB3000 Modbus Gateway User Manual

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

WiFi Setup Guide. Overview. Before you start

General Specifications. P2-08THM Analog Input

MGate MB3000 Modbus Gateway User s Manual

SHEET. BAS Portable Router BACnet Multi-Network Router. BAS Portable Router

H7625A, H7635A Humidity/Temperature Sensors

Revision History E F G H J K Revision Description: K > Allegion Rebranding.

FLEX I/O Dual Port EtherNet/IP Adapter Modules

BHM Digital Indicator User s Manual

NOVUS AUTOMATION 1/92

NETAFIM WILL NOT ACCEPT RESPONSIBILITY FOR DAMAGE RESULTING FROM THE USE OF NETAFIM'S PRODUCTS OR THE USE OF THIS MANUAL.

G5 Weighing Instrument

User s Guide. Setup+ / Webserver Configuration Tools

Ethernet Interface Module

RTU560 Connections and Settings DIN Rail RTU 560CIG10

WTX120. Legal-for-trade industrial weighing terminal. Special features. Data sheet

Gateway 1400 Reference Manual

DSCUSB Standard User Manual. mantracourt.com DSCUSB. Digital Sensor Card USB Strain Gauge Input

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

SERVICE MANUAL iforks

Panoramic Power Installation and configuration guide

H7625B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors

IPM-01 / IPM-01H MODBUS TCP/RTU Bridge User Guide

Installation and Operating Instructions

Weight Processor. HI 6500 Series. User s Guide. Hardy Process Solutions Document Number: REV D

R70 Ethernet to CAN interface Manual (1.4 EN)

Installation and Setup

LCp-100 Weight Indicator/Transmitter

AP-ENBD User Manual V0.2

Weight Indicator TAD 3 From prog. name T002L240. Technical Manual

Presented By. NicolScales.com Contact Us

DTM Distributed Transmitter Monitor

MMT330 Series Moisture and Temperature Transmitters for Oil

Transcription:

HI 6600 series Quick Start Guide HI 6600 series is a modular system of weight processors that can deliver up to 30 channels of fast, stable, high-resolution weight values to PLCs, PACs and DSCs over a single fieldbus network. This Quick Start Guide is intended for users that are already familiar with setting up Hardy Process Solutions weighing instruments. A complete User s Guide can be found under Documents and Programs online: www.hardysolutions.com Click the Product menu> Weighing Instruments > Weight Processors > HI 6600. Next, click on the Docs & Programs tab to download the User s Guide.

DIN Rail Installation: 1. Place the top slot of the instrument onto the DIN rail first. 2. Rotate the instrument until the bottom tab of the instrument engages with the DIN rail, then press firmly on the bottom on the instrument until it snaps in place. 3. Check for proper DIN rail engaguement by gently lifting up on the bottom and making sure the instrument is securely in place. 4. Repeat with additional units as required for your system

Wiring: 1. Once the units are all placed on the DIN rail (or distributed throughout a factory), remove the Quick-Disconnect connectors making note of the wiring markings found on the connector labels located on the instruments. Gateway Module Weight Processing Module 2. Cable the HardyNet Port located on the bottom of the units in series using the Module I-I Diagram and by following the notes for HardyNet terminations. HardyNet Termination Notes: A. See User's Gude for additional information on HardyNet terminations. B. Do not bundle HardyNet wiring with power wiring, relay cable or any other high-energy cables. C. Terminal block wire size ranging from 22 AWG minimum, 16 AWG Maximum. Wire temperature rating to be 90 degrees C. Wire tightening torque: 2 lb-in minimum / 4 lb-in max. D. Signals HN1+ amd HN1- to connect using twisted pair wires E. Signals HN2+ amd HN2- to connect using twisted pair wires

3. Cable the DC power located on the bottom of the units in series using the Module I-I Diagram and by following the notes for Power Input terminations. Power Input Termination Notes: A. Input Voltage Range 12-24 VDC: Weight Processor: 1.5 watts max. Gateway: 5 watts max B. Terminal Block WIre Size Range: Wire temperature rating to be 90 degrees C. 12 AWG maximum / 22 AWG minimum. Wire tiightening torque: 4.4 LB-in Minimum / 5.3 LB -IN Maximum 4. You must use a power-limited 12-26 VDC power supply (Class 2) on the DC input wiring. DC power should be supplied by a clean primary line, directly from the DC power source. a. Make sure the VDC power is shut off before installing the wires to the connector. b. Connect the 24 VDC voltage wire, ground wire and shield wire to the connector that plugs into the DC voltage header at the rear panel. The jumper connects the Earth ground and the internal ground making them common, and should remain in place. c. DC power can be supplied in series or from individual power sources. View of Bottom of Modules when wired (1 GateWay and 4 Weight Processors)

4. Cable the load cells or other type of strain-gauge based sensors to the Weight Processing Modules using the I-I diagram and by following the notes for Weight Scale Input Termination. Weigh Scale Input Termination Notes: A. If conduit is used, do not run load cell cable parallel to or in the same conduit with power wiring, relay cable or other high energy cables. B. Factory installed jumpers are to remain in place only for four wire non C2 load cell connections. Jumpers to be removed for six cell non C2 or eight wire C2 load cell connections. Excitation and Sense wires will be connected together in a junction box. C. Required load cell cable for C2 weightless calibration system and Integrated Technician: Hardy Process Solutions P/N 6020-001. D. See User's Guide for additional information on load cell connections. User's Guide is located on the Hardy Process Solutions Web Site. E. Terminal block wire size ranges from 22 AWG minimum, 16 AWG Maximum. Wire temperature rating to be 90 C. Wire tightening torque: 2 lb-in min. / 4 lb-in max. F. For clarity, only one load cell connection is shown. 5. Cable the communication ports on located on the Gateway terminal according to the protocol used and by using the I-I diagram available for the Hardy Gateway Module on the Hardy website. 6. Connect the optional display to the display port located on the Hardy Gateway module. 7. Power up the system. Initial Set-Up Discovering Weight Processing Modules present on the system: The system requires a process of discovery where the Gateway Module will identify and test communications with all Weight Processor Modules connected on the HardyNet. The discovery process is initiated by choosing DISCOVERY located in the ---DRAFT--- menu found in the --- DRAFT ---section of the display or the --- DRAFT --- page of the Webserver.

Once the discovery process is completed, proceed to setting up each individual channel by following the basic SET UP instructions outlined below. Set Up may be performed through the optional front panel display or through the integrated Webserver. If setting up using the Webserver, connect an Ethernet cable between the Hardy Gateway Module and and then follow the Communications>Ethernet TCP/IP instructions shown below before proceeding. Suggested steps when setting up the instrument for the first time Choose a specific Weight Processor Module to set up by selecting a channel either from the front panel display or on the webserver. Channel 1) Choose channel to set-up SET UP (minimum) 1) Select Unit of Measure 2) Input Total Scale Capacity 3) Select Graduation Size 4) Select Decimal Point Position 5) Input Motion Tolerance Filter 1) Num Averages 2) Waversaver Calibration 1) Cal Date 2) Cal Method a. C2 ecal b. Hard Cal 3) Complete Cal Procedure

Calibration: Section used to calibrate the instrument to the sensor(s) used. C2 Electronic Calibration (also known as ecal in China) 1. Remove all weight from the scale. 2. Set gravity correction for location of weighing system 3. Press Do C2 Cal. 4. Place a verification weight on the scale to ensure calibration is successful. Hard Cal- Traditional Calibration 1. Input the Span Weight. The span weight should be about 80% of the scale capacity. 2. Input Cal Low Weight. With nothing on the scale, the Cal Low Weight is 0, with 5 lbs on the scale, the Cal Low Weight would be 5. 3. Press Do Cal Low to set the low point on the calibration curve. 4. Place the Span Weight onto the scale. 5. Press Do Cal Hi. Refer to User s Guide if adjustments to other calibration-related parameters are required. Communication: Section used for setting up communications to the instrument. Ethernet TCP/IP 1. Connect an Ethernet cable between the instrument s RJ45 connector and a PC, then power up the instrument. A crossover cable is not required, but can be used. 2. The instrument will auto-negotiate settings suitable for a variety of operating systems and network configurations. Wait approximately 15 seconds and check to see if the green light of the Ethernet port is on and blinking if so, skip to step 8 you are connected.

3. If the green light on the Ethernet port does not light up, check that the unit s Enable DHCP is turned off and follow steps 4 through 9. 4. Using the unit s Fixed IP address (the default is 192.168.000.100), the PC must now be assigned a unique IP address (for example, 192.168.000.101) There are two simple rules for the IP Address: It must have the same network identifier as the computer. It must have a different node identifier than the computer. 5. On a PC running windows, open Internet Properties (TCP/IP). 6. Click in the Use the Following IP Address checkbox; then enter the following into the TCP/IP Properties dialog. i. IP Address = 192.168.0.101 ii. Subnet Mask = 255.255.255.000 7. Select OK on the TCP/IP Properties dialog box. The computer is now fully configured. To return the computer to the original network settings, return to the Internet Properties (TCP/IP) dialog, select Obtain an IP address automatically, and click OK. 8. The HI 6620 HGM is now configured to communicate with the PC. Enter the HI 6620 HGM s IP address into the Windows PC Web browser to access the embedded web browser. For example: http://192.168.000.100 See the HI 6600 Series User s Guide for setting up EtherNet/IP, Ethernet-UDP, Ethernet TCP/IP, Modbus TCP, or Modbus-RTU communication protocols.

MENU TREE Hardy HI 6620 Gateway Module Hardy HI 6610 Weight Processing Modules Communication Diagnostics Information Language EtherNet IP Ethernet TCP/IP Ethernet UDP Modbus-RTU Modbus-TCP Stability Weight & Voltage Optional HI 6110 Front Panel Display Display Backlight Power Saving Set Background Set Foreground Display Security USB READ ONLY Product Serial# Software Revision MultiVersion WPM Begin Programming Chinese English Split Screen Auto Mode Calibration Lock Configuration Lock Display Lock Key Pad Lock Read Only Lock Calibration Diagnostics Filter Information Operations Setup C2 ecal Hard Cal Cal Date Stability Test C2 Int. Technician Power NumAverages Waversaver READ ONLY Product Serial# Software Revision Tare Operations Zero Operations Piece Count Capacity Decimal Point Grads Instrument ID Motion Tolerance Operator ID Unit

Diagnostics: Display: Filter: Section used for diagnostics of system. Refer to User s Guide if troubleshooting and use of diagnostics menu is required. Section used for adjusting various aspects of the display, Including contrast, brightness, and optional MultiChannel display screen feature. Section used to stabilize weigh readings in an unstable environment. WAVERSAVER: Press the enter button and use the arrow keys to select the appropriate setting. WAVERSAVER eliminates unwanted noise and is typically set at 1.0 Hz. NumAverages: Set the number of readings to average to provide a stable weight. Information: Section used for checking instrument serial number, and firmware revision. Language: Section used for changing language. Operations: Section used for setting up parameters related to Tare, Count and Zero of scale. Security: It is highly recommended to see the User s Guide for setting up security functions on the instrument. Improper set up of the security settings could cause a user to be locked out from using the device. Setup: Section used for setting up operation parameters of the instrument. Capacity: Sets the normal operating capacity of scale. Decimal Point: Sets to decimal point for the weight resolution. Grads: Sets the graduation size of the display increments. Instrument ID: Allows the instrument to be named. Motion Tol: Choose the level of acceptable scale instability. Operator ID: Optional area for entering an operator ID. Unit: Choose the units such as lbs or kg that is desired to show on the scale.

Notes

Hardy Process Solutions sincerely appreciates your business. We encourage input about the performance and operation of our products from our customers. Should you not understand any information in this guide or experience any problems with this product, please contact our Technical Support Dept. at: Phone: (858) 278-2900 Toll Free: 1-800-821-5831 FAX: (858) 278-6700 E-Mail: hardysupport@hardysolutions.com Or visit our web site at: http://www.hardysolutions.com Proudly made in the U.S.A PN: 0596-0334-01 Rev. X1 02/14