TABLE OF CONTENTS TECHNICAL APENDIX A ETHERNET INTERFACE CONNECTOR PINOUT Patch cable pinout Crossover cable pinout TECHNICAL APENDIX B DEVICE DISCOVERY UTILITY 1. Device discovery utility installation 2. Device discovery utility configuration 2.1 Automatic IP configuration (DHCP) 2.2 Manual IP configuration (Static IP) TECHNICAL APENDIX C CONFIGURATION OF THE NM-541FOR UDP SOCKETS MULTICAST FUNCTION TECHNICAL APENDIX D INSTALLING REAL PORT DRIVER IN WINDOWS
TECHNICAL APENDIX A ETHERNET INTERFACE CONNECTOR PINOUT Multiple NM-541 can be connected to a local network by using a commercial Ethernet switch. UTP cables in that case should be ended at both sides with RJ45 male connectors with a pinout as indicated in table 1 (straight/patch cable connection). Computer should also have a standard network card installed. Front view of the RJ45 MALE pin. Pin's top with Locking clip Name Pin Wire Color Pin Name TX+ 1 White/Orange 1 TX+ TX- 2 Orange 2 TX- RX+ 3 White/Green 3 RX+ 4 Blue 4 5 White/Blue 5 6 Green 6 7 White/Brown 7 8 Brown RX- RX- 8 Table 1: Pinout for straight/patch cable with description names In cases where only one device is installed, computer and NM-541 can be connected using a crossover UTP cable (table 2) First Side of cable Color Second Side of cable Name Pin Pin Name Color White/Orange TX+ 1 3 RX+ White/Orange Orange TX- 2 6 RX- Orange White/Green RX+ 3 1 TX+ White/Green Blue 4 White/Blue goes to 7 Blue 5 8 White/Blue 6 2 White/Brown 7 4 White/Brown Brown 8 5 Brown Green RX- TX- Green Table 2: Pinout for Ethernet 10/100Base-T Crossover cable with description names
TECHNICAL APENDIX B DEVICE DISCOVERY UTILITY 1. INSTALLING THE DEVICE DISCOVERY UTILITY The following procedure shows how to install Device discovery utility which is useful for tracking and managing NM-541 devices connected to a local network. When installing discovery utility NM-541 does not have to be connected or powered on. STEP 1: Open windows explorer and find Device Discovery Utility in supplied CD-ROM. Double click on DUSetup.exe to begin installation STEP 2: Windows could then give a warning that user is about to run the selected file. Click Run to continue STEP 3: Click Next to continue
STEP 4: Select destination folder for the Utility to be set up (default folder recommended) and click Next STEP 5: Copying of the needed files is ready to begin. Click Next to continue STEP 6: After completion of installation a success notice is supplied. Click Finish to exit.
2. DEVICE DISCOVERY UTILITY CONFIGURATION Before running Device Discovery Utility for the NM-541 installer must first check that: NM-541 is powered up correctly Ethernet cables are connected Device Discovery Utility has been set up properly After running utility (located under Start>All Programs>Digi>Digi Device Discovery) a not properly configured message could appear. This means that IP address has not properly been assigned and needs reconfigure.
Configuration of the network settings can be done within the Device Discovery Utility either by letting the network switch assign IP address for every NM-541, or manual. Right click on highlighted IP address of every device to get the drop down menu and select Configure network settings as shown in figure above 2.1 Automatic IP configuration (DHCP) Obtaining Network settings automatically via DHCP function of Ethernet switch can be done by checking Obtain network settings automatically radio button and then Save. NM-541 will then restart and after a minute it will appear again with no warnings in the window. In the bottom left corner the new IP details appear indicating that it is automatically configured (DHCP). If no new settings appear in window after a minute user should click on the refresh button to research for NM-541 devices over local network.
2.2 Manual IP configuration (Static IP) Configuring Network settings manually (recommended) can be done by checking Manually configure network settings radio button. Select for every NM-541 a different address in IP address field matching the 192.168.0.X or 192.168.1.X local network standard and leave subnet mask the same (255.255.255.0) for every device. Click Save to continue. NM-541 will then restart and after a minute it will appear again with no warnings in the window. In the bottom left corner the new IP details appear indicating that NM-541 it is manually configured (Static IP). If no new settings appear in window after a minute user should click on the refresh button to research for NM541 devices over local network
TECHNICAL APENDIX C CONFIGURATION OF THE NM-541 FOR UDP SOCKETS MULTICAST FUNCTION After discovering and setting the NM-541 to a fixed IP address as described in the user manual the following steps must be completed to setup the device to multicast the received NMEA data to UDP sockets. STEP 1: Double click on the discovered device in the Digi Discovery Utility to bring up the login menu on an http explorer. Complete the appropriate field and press the Login button Username: root Password: nm2003 STEP 2: Click on Serial Ports under Configuration menu as shown below
STEP 3: Click on Port 1 under Serial Port Configuration menu STEP 4: Click Change Profile to set a new profile
STEP 5: Select the UDP sockets radio button and press Apply STEP 6: Configure the new page as shown below. 1. Select the Automatically send serial data option 2. Deselect the Send after following number of milliseconds option if enabled 3. Set the number of bytes to 1 in the Send after the following number of bytes option 4. In the box under the Send data to the following network services fill a distinctive name for the computer that will receive the data, the IP address and the UDP port the software is configured for reception and press the Add button. With the UDP multicast feature you can add multiple computers provided that you specify each time the above particulars and add it to the table
STEP 7: After successful configuration of the Port Profile Settings menu it should look as follows. Click on Apply to store the changes STEP 8: Click on the Basic Serial Settings menu and configure Baud rate to 4.800, Data Bits to 8, Parity to None, Stop Bits to 1 and Flow Control to None. Supply a name in the Description edit box to describe configured NM-541 device
STEP 9: After successful completion select Serial Ports menu to confirm the changes. Click on Logout to end the configuration procedure
TECHNICAL APENDIX D INSTALLING REAL PORT DRIVER IN WINDOWS XP Before installing Windows driver for the NM-541 installer must first check that: NM-541 is powered up correctly Ethernet cable is connected Discovery utility is already set up Either fixed IP address (recommended) or DHCP address has been assigned to NM-541 NM-541 is configured as a Real-Port (already done in production stage) STEP 1: Connect NM-541 power and network cable, open control panel and select Add Hardware STEP 2: Select Next to continue with the Add Hardware Wizard
STEP 3: Select Yes, I have already connected the hardware and click Next STEP 4: Select Add a new hardware device and click Next STEP 5: Select install the hardware that I manually select from a list (Advanced) and click Next
STEP 6: Select from the list the option: Multi-port serial adapters and click Next STEP 7: Select Have Disk to point to driver location (provided CD-ROM or other location) STEP 8: Select Brows to begin searching
STEP 9: Find folder of drivers and click open STEP 10: After correct selection of driver folder, Driver for NM-541 should appear as a Standard RealPort Device. If so continue by pressing Next. Otherwise search in another location STEP 11: The wizard is ready to complete installation. Click Next to continue
STEP 12: The device should be listed as in this figure. IP address could take a value assigned by DHCP server and might vary from the indicated value. Click Next to continue STEP 13: Select which COM Port Name will be assigned in virtual serial port (selection of default Port is recommended). Click Next to continue STEP 14: Click finish to complete installation
STEP 15: After completion the Device Manager should look like in this figure