Active UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Similar documents
Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Transceiver Hub with Integral Camera Power

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Isolated Camera Power

Passive UTP Transceiver Hub Installation Guide

Rack Mount Power Supplies

AL168 Series Multi-Output Power Supplies

PoE Managed Midspan Solution for Standard Network Infrastructure

DC Outdoor Power Supply/Chargers

OWNER S MANUAL SINGLE CAT5E/6 3D EXTENDER B-320-1CAT-HDIR

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

OWNER S MANUAL SINGLE CAT5E/6 3D EXTENDER B-200-1CAT-HDIR. Receiver

1 Overview. 2 Specifications. Product Installation Document

Installation and Operation Manual CX452 with CHM22/CXM22

CLFE(X)UTP INSTALLATION AND OPERATION MANUAL

CLFE(X)COAX INSTALLATION AND OPERATION MANUAL

HDBaseT EXTENDER B-520-TX-230-IR B-520-TX-330-IR INSTALLATION MANUAL

TVA2.1 2-Channel Digital Amplifier Installation Manual

4K HDR HDBaseT Extender B-560-EXT INSTALLATION MANUAL

E-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation and Operation Manual

5 B&W Rear View System Camera

Installation Instructions CX254 Card Cage Power Injector

Monochrome Camera. Features. User manual

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

U-150 Integrated Amplifier User s guide

Cantata m100 Amplifier

Neets Switching Relay - 2. Installation manual

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

OWNER S MANUAL CD-2 V 1.3

MPF-1, Mains Power Filter User Manual

Expandable Power Systems

HDBaseT EXTENDER B-520-EXT-230-RS-W INSTALLATION MANUAL

Installation Guide. Rev

OWNER S MANUAL GEQ 131/ 131LF GEQ 215/ 215LF GEQ 231. Single Channel 31 Band Graphic Equalizer. 2 Channel 15 Band Graphic Equalizer

Installation Manual. 12 Volt Power Supplies. 18-Port. 9-Port RET18PT RET9PT

PS8 - II. Professional Power Sequencer. User s Manual

Accessory Packages for the Allegiant

VE8012A/VE8012AR DUAL NETWORKED STATION PORT

AVR Manual. Isolate. Restore. Inspire! Audio / Video Power Isolation Units with Automatic Voltage Regulation. 19 Pro Series Rack Mount (RM) Faceplate

OWNER S MANUAL >> BINARY HD MATRIX SWITCHER B-100-HDMATRIX-4X4 / B-100-HDMATRIX-8X8

Roth BAR 2LX High-Power Soundbar with Wireless Subwoofer. Turn it up. Roth BAR2 LX Manual UK VJ.indd 1 19/06/ :07

WIRELESS BLUETOOTH BOOMBOX

iconverter 2-Module Power Chassis

INSTALLATION MANUAL. HDMI 1x4 Splitter B-230-HDSPLTR-1x4. B-230-HDSPLTR-1x4 HDMI OUT 4 HDMI OUT 3 HDMI OUT 2 HDMI OUT 1 HDMI OUT 4 HDMI IN

Quick Start Guide. C-100 Series Switches

Monochrome Cameras LTC 0140 LTC 0142 LTC Eng. Philips Communication & Security Systems

INSTALLATION MANUAL. HDMI 1x8 Splitter B-230-HDSPLTR-1x8 B-230-HDSPLTR-1X8

Kogan Bluetooth Karaoke System with Dual Microphones KAKAR2MICA

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology

DMX Tool Splitter 1 to 5 User Manual

DLHD2100 Owners Manual

ITEM NO: SP-001, SP-001P, SP-001VP, SP-001VPD, SP-002, SP-002VP, SP-002VPD, SP-003, SP-004, SP-004VPD, SP-005, SP-006, SP-016C, SP-016T

USB CASSETTE PLAYER MODEL NO. : GE USER MANUAL -

Model 160. Model 186. Model 247. Surge Protective Devices. Installation & Operation Manual. Model 160. Model 186. Model 247 (EDCO RM-CX06-16R)

Quick Guide. ENC-H Video Encoder XX

Installation/ Operation Manual

FC-29W 9 UN-UNIVERSAL Dome Housing. Installation Instructions

Surge Protection for Surveillance Systems

RS232 Control Box. Table of contents

User Manual ABS Molded Powered Loudspeaker MODEL: PB15PKG. QUESTIONS / COMMENTS CALL or pr o.com

Digital Color Cameras

SUBWOOFER SYSTEM YST-MSW10

Passive CCTV Hub Plus (500134) Installation Guide

TS-VGA OWNERS MANUAL. TS-VGA_manual_en_v1

Industrial Camera GP-MF602. Before attempting to connect or operate this product, please read these instructions completely.

ebridge200b - Managed Two Port Transceiver Board

Industrial 1-Port Coax/UTP Long Reach PoE+ 4-Port. 10/100TX PoE Extender LRP-104CET. User s Manual

VMI. Technical Documentation. 600 Industrial Drive, New Bern, N.C (tel / fax /

Installing and Configuring Rialto Analytic Appliances

PRE116/126. User Manual.

SoundwebTM. Installation Guide

Isobar 12-Outlet Network Server Surge Protector, 15 ft. Cord, 3840 Joules, Diagnostic LEDs, 1U Rack-Mount, Metal Housing

OPERATIONS MANUAL. n.form I/O Expander (RACK MOUNT) Document Number: Rev B

HDMI 1x2 Splitter B-230-HDSPLTR-1x2 INSTALLATION MANUAL HDMI OUT 2 HDMI OUT 1 B-230-HDSPLTR-1X2 POWER HDMI IN

SOUNDSTICKS WIRELESS. Setup Guide. Downloaded from

HMXAT200 Series System Controller

APT20. User Manual.

DVAA Series Disk Array for DVR1 Series Digital Video Recorder

MODEL GE4138 DIGITAL CD/MP3/USB/SD ENCODING WITH PLL AM/FM ALARM CLOCK STEREO RADIO - USER MANUAL -

HDBaseT EXTENDER B-520-EXT-330-HV INSTALLATION MANUAL

MP SERIES PROFESSIONAL POWER AMPLIFIER

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN

7 LCD CCTV Test monitor. Quick guide

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

PS-20. Power Supply. User Manual Rev F

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

IA1000. Integrated Amplifier with USB / SD Inputs IA1000. QUESTIONS/COMMENTS CALL or

Roth BAR 2LX High-Power Soundbar with Wireless Subwoofer. Turn it up.

C-300 Preamplifier User s guide

Installing the Cisco 2524 and Cisco 2525 Routers

MODEL 805 USER MANUAL

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

Daily use. indicating that the loud speakers

ST-C5VRS-600 VIDEO AND RS232 EXTENDER Installation and Operation Manual

HDMI MATRIX SWITCHER B-120-HDMATRIX-4x4/8x8 CONFIGURATION UTILITY MANUAL

Transcription:

Active UTP Transceiver Hub with Integral Isolated Installation Guide Models Include: HubWayLD8Di HubWayLD16Di - UL Listed eight (8) Channel Active UTP - UL Listed sixteen (16) Channel Active UTP Transceiver Hub with Integral Isolated Transceiver Hub with Integral Isolated HubWayLD82Di HubWayLD162Di - UL Listed eight (8) Channel Active UTP - UL Listed sixteen (16) Channel Active UTP Transceiver Hub with Integral Isolated Transceiver Hub with Integral Isolated - Includes eight (8) UL Listed Accessory - Includes sixteen (16) UL Listed Accessory HubWayAv Balun/s HubWayAv Balun/s HubWayLD83Di HubWayLD163Di - UL Listed eight (8) Channel Active UTP - UL Listed sixteen (16) Channel Active UTP Transceiver Hub with Integral Isolated Transceiver Hub with Integral Isolated - Includes eight (8) UL Listed Accessory - Includes sixteen (16) UL Listed Accessory HubWayDv Balun/s HubWayDv Balun/s Rev. 030408 More than just power. TM

Overview: Altronix HubWayLD8Di/16Di Active UTP Transceiver Hub w/integral Isolated transmits UTP video, RS422/RS485 data and power over a single CAT-5 or higher structured cable. Unit provides 8 or 16 camera channels in a space saving 1U EIA 19 rack mount chassis which may be rack, wall or shelf mounted. transmission range is up to 3000 ft. max. per channel. Units are compatible with AC and/or DC fixed or PTZ cameras when utilizing Altronix HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Balun/s. In addition, the unit features individually selectable or PTC protected outputs with surge suppression. An optional HubSat4D Passive UTP Transceiver Hub with Integral can be used as an accessory module to transmit video from up to 4 cameras over a single CAT-5 or higher structured cable back to the HubWayLD8Di/16Di. In addition, the HubSat4D provides power to these cameras locally to eliminate the possibility of voltage drop associated with long cable runs. HubWayLD Specifications: HubWayLD8Di/LD82Di/LD83Di Input: 115VAC 60Hz, 2.5 amp or 230VAC 50/60Hz, 1.5 amp. : Eight (8) channels of video over twisted pair up to a distance of 3000 ft. per channel. Eight (8) 75 ohm video outputs. : Unit provides up to 1 amp max. per channel not to exceed a total of 8 amp (150VA) maximum current. Agency Listings: UL Listed for Commercial CCTV Equipment (UL 2044). CUL Listed - CSA Standard C22.2 No.1-04, Audio, and Similar Equipment. : RS422/RS485 data inputs. : Individually selectable or power outputs with position. Individual electronically isolated PTC outputs. PTCs are rated @ 1 amp per channel. Surge suppression. Visual Indicators: AC input power indicator. signal and power LED indicators. HubWayLD82Di HubWayLD8Di with eight (8) UL Listed Accessory HubWayAv Balun/s for s. HubWayLD83Di HubWayLD8Di with eight (8) UL Listed Accessory HubWayDv Balun/s for 12VDC s. Common Specifications: Additional Models: HubWayLD16Di/LD162Di/LD163Di Input: 115VAC 60Hz, 5 amp or 230VAC 50/60Hz, 2.5 amp. : Sixteen (16) channels of video over twisted pair up to a distance of 3000 ft. per channel. Sixteen (16) 75 ohm video outputs. : Unit provides up to 1 amp max. per channel not to exceed a total of 16 amp (300VA) maximum current. Features: Picture and Gain control. Illuminated master power disconnect circuit breaker with manual reset. IEC 320-3-wire grounded line cord (detachable). Unit can be rack, wall or shelf mounted. 1U rack mount chassis for use in standard EIA 19 rack. Accessories: Balun/s: - HubWayAv - for use with cameras. - HubWayAv2 - for use with cameras. - HubWayDv - for use with 12VDC cameras. - HubWayDvi - for use with non-isolated 12VDC cameras. Optional HubSat4D allows transmission of up to four (4) video signals over a single CAT-5 or higher structured cable. HubWayLD162Di HubWayLD16Di with sixteen (16) UL Listed Accessory HubWayAv Balun/s for s. HubWayLD163Di HubWayLD16Di with sixteen (16) UL Listed Accessory HubWayDv Balun/s for 12VDC s. WARNING: To reduce the risk of fire or electric shock do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to all local codes. Installation Instructions: 1. Set the input voltage selector switch located on the left side of the HubWayLD8Di/LD16Di unit (facing front panel) for 115VAC or 230VAC operation (Fig. 1k, pg. 4). 2. Attach mounting brackets to HubWayLDi unit for rack or wall mount installation (Figs. 6-7, pg. 8). Affix rubber pads to HubWayLD for shelf installation (Fig. 8, pg. 8). - 2 - HubWayLD Active Isolated Unit

3. Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least 3 from any video monitors). 4. Set illuminated master power disconnect circuit breaker to the () position (Fig. 5, pg. 7). 5. Plug the grounded AC line cord (included) into the IEC 320 connector of the HubWayLD8Di/HubWayLD16Di unit (Fig. 1j, pg. 4). Insert the plug end of the line cord into a grounded AC receptacle. 6. Set voltage output selector switch of each camera channel for or (Fig. 1d, pg. 4). 7. Connect the BNC video outputs for HubWayLD8Di/LD16Di Channels 1-8 (Channels 1-16) to the corresponding video inputs on the head end equipment (DVR) (Fig. 1f, pg. 4). 8. Connect the RS422/RS485 output of the head end equipment (DVR) to the one (1) or both data input terminal blocks of the HubWayLD8Di or HubWayLD16Di unit (polarity must be observed) (Fig. 1e, pg. 4). Note: The input terminals of the HubWayLD8Di or HubWayLD16Di must be wired in parallel for proper operation. When using fixed cameras disregard this step. 9. Connect Balun/ at camera 1 to the HubWayLD8Di or HubWayLD16Di unit utilizing CAT-5 or higher structured cable. Plug the RJ45 connector at one end of the structured cable into the RJ45 jack marked [Channel 1] of the HubWayLD8Di/LD16Di (Fig. 1a, pg. 4). Plug the RJ45 connector at the opposite end of the structured cable into the RJ45 jack of the Balun/ located at camera 1. For cameras use Altronix model HubWayAv/HubWayAv2 Balun/ (Figs. 2a, 2b, 2e, pg. 5). For 12VDC cameras use Altronix model HubWayDv Balun/ (Figs. 2c, 2d, pg. 5). For non-isolated 12VDC cameras use Altronix model HubWayDvi Balun/ (Figs. 2c, 2d, pg. 5). Repeat steps 6-9 for each additional camera (Channels 2-8 or Channels 2-16). Note: When a particular camera exceeds the maximum distance for power transmi ssion, a local external power source is required. Optionally, an Altronix HubSat4D Passive UTP Transceiver Hub with Integral may be utilized (Fig. 4a, pg. 6). The combined total cable distance must not exceed 3000 ft. for video transmission between the HubWayLD8D i/ld16di and each camera routed through the HubSat4D. 10. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5, pg. 7) and measure the output voltage at the power output of each Balun/ (Figs. 2b, 2d, pg. 5) before powering each camera to ensure proper operation and avoid possible damage. HubWayAv/HubWayAv2 - Terminals marked [AC POWER] (Figs. 2a, 2b, 2e, pg. 5). HubWayDv/HubWayDvi - Terminals marked [ 12VDC +] (Figs. 2c, 2d, pg. 5). 11. Set illuminated master power disconnect circuit breaker to the () position to make the final connections (Fig. 5, pg. 7). 12. Connect the power outputs of the HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Balun/s to the power inputs of the cameras (Figs. 2a-2e, pg. 5). Polarity must be observed. 13. Connect the terminals marked [+ DATA -- ] of the HubWayAv or HubWayDv Balun/s to the data terminals of the cameras for PTZ control (Figs. 2a-2e, pg. 5). Polarity must be observed. When using fixed cameras disregard this step. 14. Connect the BNC connector of the HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Balun/s to the BNC video outputs of the cameras (Figs. 2a-2e, pg. 5). 15. Upon completion of wiring set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5, pg. 7). 16. The power LEDs (Red) located on the front of the HubWayLD8Di/LD16Di will illuminate when AC power is present (Fig. 1c, pg. 4). Note: If any of these LEDs are not illuminated either a voltage output selector switch is in the position or the PTC is tripped for that channel. To reset the PTC: 1. Set the voltage output selector switch for that corresponding channel to the position. Switch must remain in the position for approximately 2 minutes in order for the PTC to reset. 2. Eliminate the trouble condition (short circuit or overload). 3. Set the voltage output selector switch for or (Fig. 1d, pg. 4). 17. AC LED (Green) of the HubWayAv or DC LED (Red) of the HubWayDv/HubWayDvi Balun/s will illuminate indicating power is present at the cameras (Fig. 2b, 2d, pg. 5). 18. The video signal indicator LEDs (Red) located on the rear of the HubWayLD8Di /LD16Di will illuminate when video signal is present (Fig. 1i, pg. 4). If any of these LEDs are not illuminated, no video signal is present for that corresponding channel. 19. Optimize the picture quality for Channels 1-8 (Channels 1-16) by adjusting the corresponding potentiometers marked [Picture] (Fig. 1g, pg. 4). 20. Set gain for Channels 1-8 or Channels 1-16 by adjusting the corresponding potentiometers marked [Gain] (Fig. 1h, pg. 4). HubWayLD Active Isolated Unit - 3 -

1e - : Removable terminal blocks for RS422/ RS485 input from head end equipment (DVR) for PTZ control. Fig. 1 1b - Channels 1-4, Channels 5-8, Channels 9-12 & Channels 13-16: CAT-5 or higher structured cable from optional HubSat4D enables video transmission from up to four (4) cameras. Top View input from Head End Equipment (DVR). + -- 1d - Output voltage switches: Selects // for each output. 1c - LED(s) 1-16: indicators. 1a - Channels 1-8 (HubWayLD8i) or Channels 1-16 (HubWayLD16i): CAT-5 or higher structured cable to /Balun s at cameras 1-8 or 1-16. When using an optional HubSat4D any of the outputs can be utilized for the data transmission to PTZ s. Front RESET 13 14 15 16 CH 13-16 1 2 3 4 CH 1-4 5 6 7 8 CH 5-8 9 10 11 12 CH 9-12 - 4 - HubWayLD Active Isolated Unit + DATA - 9-16 + DATA - 1-8 Rear 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 16 AC POWER PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN 1j - IEC 320 Connector: 115VAC 60Hz/230VAC 50/60Hz (grounded line cord included). 1i - LED(s) 1-16: signal indicators. 1h - Gain: Regulates the output video and sync levels. 1g - Picture: Adjusts video quality. 1f - BNC Connector: outputs to head end equipment (DVR). 115VAC 220VAC 1k - Input Voltage Switch: Selects 115VAC 60Hz/230VAC 50/60Hz (switch is located on the left side of the unit).

HubWayAv, HubWayAv2, HubWayDv, and HubWayDvi Balun/s: Input Voltage Altronix Model Number from HubWay Unit Output Voltage to Type LED HubWayAv */ */ */ Green HubWayAv2 */ */ */ N/A HubWayDv */ 12VDC 12VDC cameras Red HubWayDvi */ 12VDC electronically isolated 12VDC cameras without isolation Red *Based on camera load and structured cable length. Fig. 2 Fig. 2a VIDEO HubWayAv VIDEO BALUN/COMBINER CAT5 AC + DATA-- POWER Fig. 2c VIDEO HubWayDv VIDEO BALUN/COMBINER CAT5 + DATA-- -- 12VDC+ * Also Available as: HubWayDvi Balun/ for non-isolated 12VDC cameras RJ45 Jack Wire Connectors RJ45 Jack Wire Connectors Fig. 2b Fig. 2d To BNC Connector of Structured Cable from HubWay8CD or HubWay16CD Green LED AC to -- to + To BNC Connector of Structured Cable from HubWay8CD or HubWay16CD Red LED + 12VDC -- to -- to + Fig. 2e HubWayAv2 Cat5 back to HubWay or HubSat to to HubWayAv/HubWayAv2 passes AC voltage from pins 4, 5, 7, 8 to terminals marked [AC ] (Fig. 3, pg. 5). from HubWayDv/HubWayDvi converts AC voltage to DC voltage from pins 4, 5, 7, 8 to terminals marked [-- 12VDC +] (Fig. 3, pg. 5). Fig. 3 - CAT-5 Structured Cable Wiring Color Codes and PIN Configurations 1 - White/Orange [VIDEO +] 2 - Orange [VIDEO -- ] 3 - White/Green [DATA +] 4 - Blue [AC 1] 5 - White/Blue [AC 2] 6 - Green [DATA -- ] 7 - White/Brown [AC 2] 8 - Brown [AC 1] HubWayLD Active Isolated Unit - 5 -

Typical Applications: Fig. 4 Head End Equipment (DVR) RS485 Monitor Rear 8 7 6 5 4 3 2 1 PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN AC POWER 1 2 3 4 CH 1-4 5 6 7 8 CH 5-8 + DATA - 1-8 Front CAT-5 CAT-5 Four (4) signals on a single CAT-5 (CAT-5) CAT-5 Max. video 3000 ft. Fixed HubWayAv Balun Fixed HubWayDv/Dvi Balun HubWayDv/Dvi PTZ Balun HubWayAv Balun PTZ PTZ HubWayAv Balun Outdoor PTZ Outdoor NEMA Rated Supply HubWayAv or HubWayDv/Dvi Balun Fixed CAT-5 HubWayDv/Dvi Balun / Provided by HubSat4D 115VAC Input, 50/60Hz Fig. 4a - Optional hookup utilizing HubSat4D. (Coax) Fixed 115VAC Input, 50/60Hz - 6 - HubWayLD Active Isolated Unit

Rack Mount Chassis Mechanical Drawing & Dimensions (H x W x D approximate): 1.625 x 19.125 x 8.5 (41.275mm x 486mm x 215.9mm) REAR 1.625" 41.28mm 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN AC POWER TOP & BOTTOM 17.625" 447.67mm 8.5" 215.9mm FRONT 1 2 3 4 CH 1-4 CH 5-8 5 6 7 8 9 10 11 12 CH 9-12 13 14 15 16 CH 13-16 + DATA -- 1-8 + DATA -- 9-16 0.75" 19.05mm (ON) 19.125" 485.78mm Fig. 5 Illuminated master power disconnect circuit breaker: position Circuit breaker tripped Switch not illuminated. RESET (ON) position Switch illuminated. The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude to constitute an electric shock. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel. HubWayLD Active Isolated Unit - 7 -

Mounting Options: Rack Mount Installation 1- Remove and discard factory installed screws from both sides of rack chassis (Fig. 6a). 2- Install mounting brackets (A) on the left and right side of rack chassis using the four (4) flat head screws (B) (included) (Fig. 6b). 3- Place unit into desired EIA 19 rack position and secure with mounting screws (not included) (Fig. 6c). Fig. 6 Fig. 6a Fig. 6b Fig. 6c Top Top Top Front Left B Front Left Front Left Remove A Wall Mount Installation 1- Install mounting brackets (A) on the left and right side of rack chassis using four (4) flat head screws (B) (included) (Fig. 7a). 2- Place unit at desired location and secure with mounting screws (not included) (Fig. 7b). Fig. 7 Caution: It is necessary to make sure mounting screws Fig. 7a Fig. 7b are securely fastened to a beam when installing the unit vertically. B A Dotted lines indicate studs behind sheetrock. Shelf Installation 1- Position and affix rubber pads (C) (included) at each corner on the bottom of the unit (Fig. 8). 2- Place unit in desired location. Fig. 8 C Left Side Rubber Pad Mounting Hardware (Included): A B C Two (2) mounting brackets Six (6) flat head screws for mounting brackets. Four (4) rubber pads. Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 website: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A. IIHubWayLD8Di/HubWayLD16Di J15N MEMBER - 8 - HubWayLD Active Isolated Unit