Application description

The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal.

idim Standalone idim idim Sense (316) (Master ) idim Ballast s idim Sol o Multisensor (312), (PIR extension) idim Sense (316) (PIR extension)

Switch Actuator, 4-fold, 16 A, MDRC AT/S , GH Q R0111

Use of the application program. Contents overview. Gamma instabus Application program description. November 2016

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

Switch Actuator, 4-fold, 20 A, MDRC AT/S , GH Q R0111

HDL KNX / EIB-BUS HDL KNX / EIB BUS M/HS05.1. (Intelligent Installation Systems) Product Manual. Contents

KNX function and configuration

High-performance switching actuators

PRESENCE DETECTOR, CONSTANT LIGHT CONTROLLER PD00D01KNX. Product Handbook

Use of the application program

Application program: description and examples

FCU-MULTI Modbus Fan Coil Unit Controller

Swiss Garde 360 PresenceDALI Master A-Comfort 24 m

Manual and application description 4 channel 0-10V dimmer V2.0

ABB i-bus EIB. Shutter Actuator, 2-fold, 6 A, 230 VAC, MDRC JA/S 2.6.1, GH Q R0111

An-10 Wireless Lighting Control

As soon as the luminaires are switched off, the built-in relay disconnects the control gear from the mains supply, reducing power loss to 0.5 W.

Manual and application description KNX/EIB LED driver V2.0

Application description. KNX push-button 1gang. KNX push-button 2gang. KNX push-button 3gang. KNX push-button 4gang. Page 1/51

SWISS GARDE 360 HOKUSPOKUS KNX/KLR APPLICATION DESCRIPTION

A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 Controls:

Lighting control for commercial buildings

Operating voltage Maximum

Lighting Control System for Indoor Applications LIGHT CONTROLLER L LIGHT CONTROLLER L

EAE KNX Switch Actuator

6173 AG GJB A0138

VARIA VARIA 826 S WH KNX VARIA 826 S BK KNX D GB F I E NL. Installation and operating instructions Room thermostat VARIA 826 S KNX

B.IQ push button comfort 1-4gang, Flush-mounted (Up) x, x, x, x

2 WIRE video door entry system

EY-EM : Remote I/O module, ecolink

Use of the application program. Functional description. GAMMA instabus Application program description. April A4 Roller shutter switch

KNX/EIB Intelligent Installation Systems

Installation and Setup guide VARIO Series

Use of the application program

ECL Comfort V a.c. and 24 V a.c.

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/

4-gang and 8-gang switch actuator 16A C-load SE

Application description. KNX Push-button module 1gang. KNX Push-button module 2gang

Plan for intelligent future safety

MTN MTN

Small and Medium Building New and Renovation Prescription Assistance Complete Solution

General catalogue Export SMOUTS ARCHITECTEN

Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD

LRI1655, LLC1655 Datasheet ActiLume 1-10V System

Electrical devices may only be mounted and connected by electrically skilled persons.

Product and functional description

Product and functional description

2 WIRE Video Door Entry system

Connections, displays and operating elements. Hand 1 / / 4

EIB/KNX ENO Radio bus interface (32-channel)

Application description

Lighting Control System for Indoor Applications LIGHT CONTROLLER LW RADIO-OPERATED VERSION ENOCEAN RADIO-OPERATED CONTROLLER

switching controlling counting

RC-CDTO. Pre-programmed room controller with display, communication and three-point control

Mini Recessed PIR. Model: PDFM360MINI. Installation & Operating Instructions

KNX Technical Manual Busch-Presence detector KNX / Busch-Watchdog Sky KNX

Room controller STRA-17

Front view. Internal view. Legend

Motion Sensor 2 with temperature sensor

Control TECHNICAL GUIDE 06

Chorus Home Automation KNX - Easy BUS

KNX DALI-Gateway Basic REG-K/1/16/64

1 Safety instructions. 2 Device components. 3 Function. Control unit 1-10 V, 3-gang. Art.-No.: 2193 REG. Operationsmanual

VARIO REMOTE CONTROL INSTRUCTIONS

K-BUS Shutter Actuator. User manual-ver. 1

instabus EIB System Actuator

LCC1653/01, LRI1653/01 ActiLume DALI System

gesis FLEX Decentralized room automation Modular Compact Pluggable Room for the future.

Application description. Motion detector KNX- BCU

Glass sensors 35. Supplementary products 39

Data sheet. Function description. Benefits

Technische Daten: instabus EIB supply instabus line: YY 6 x 0.6 mm; red: bus (+) / black: bus (-)

DIN RAIL 12/8/4 OUTPUT MODULE. BOxxB01KNX. Product Handbook

Mounting and System Description for SSZ-Safety-Switching-Rails

Pre-programmed room controller with display and communication

Functional description. Use of the application program. GAMMA instabus Application program description. June C0 Sensor Switch

Basic principles PL. Sending units

Product documentation

Pre-programmed room controller with display and communication

Rev KNX Technical Reference Manual ABB i-bus KNX. KNX Sensors

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

LP-STAR. Compact emergency lighting power supply with STAR technology Eaton, All Rights Reserved.

Push-buttons 18. Light scenes push-buttons 21. Push-buttons with thermostat 22. Labelling ields 24

Universal Controller

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions

Installation Instructions

Technical Manual MDT Push Buttons

RMG 8 Switch Actuator. RME 8 / RMX 4 Switch Actuator Modules. JMG 4 Blinds Actuator (for JMG 4 refer to Chapter 1.3)

Comprehensive Light Management

BST BuildingSystemsTrainer

WAGO Lighting Management The Lighting Control Solution Stay in Control of Your System

Multi-Measuring-Interface MMI 6000

Blind actuator 4-gang 230 V AC Order-No

Application description for the KNXnet/IP Interface Web

Product Manual V ABB i-bus EIB / KNX DALI-Gateway DG/S 1.1. Intelligent Installation Systems ABB

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

PRO Command ALCMS PLC Based Control and Monitoring System

Ditec ION Automation for sliding gates up to 600 kg

Transcription:

SeeTool - Solutions for Office building segment Application 3.0.0.0.0.4 Movement dependent automatic light control, 2 room solution

Lighting control functions The light is automatically switched ON when a person enters the room and the brightness value is below a predefined brightness threshold. It is automatically switched OFF when no movement is detected in the room and preset delay time has passed. Application areas Lighting The application is defined for two single room offices with basic requirements on comfort for lighting control. It is also usable in all types of infrequently visited areas and occasionally used rooms as it offers basic, simple lighting control, which switches the light automatically dependant on people s movement. Energy savings Lights will not remain on all night, or even when not needed. Energy savings are achieved by turning ON and OFF the lights automatically. This reduces the time for the lights turned on and can lead to savings of 40% compared to installations without automatic function. Future proof The application is prepared and defined for integration into a Building Management System if required, through the open technology communication network. Flexibility For optimised cost, the amount of units is reduced to a minimum, but allows maximum of flexibility when walls are removed and rooms are combined. Reliability Design, planning and installation documents are pre-defined which makes the entire building process faster and more reliable. User documents and descriptions are prepared to assist in user training. The application works as an individual, stand alone room control unit and can be installed, used alone, or combined with the entire network. EN 15232 A class solution tested & validated

Functions The light is automatically switched ON when a person enters the room and the brightness value is below a predefined brightness threshold. It is automatically switched OFF when no movement is detected in the room and preset delay time has passed. Delay is adjustable by ETS software. Default is 25 min. functions The brightness threshold is also adjustable by ETS software. Our recommendation is 300 lux. Components The application consists of two movement detectors (wall mounted) and one DIN-rail switch actuator (mounted in the cabinet or close to the room). MTN647393 Switch actuator REG-K/2x230/16 with manual mode Design ranges (Frames not included. Other designs and colours available.) EXXACT WDE002959 2x PIR 180 /2.20m flush mounted Installation Movement detector recommended to be installed on the wall at a height of 2.20m.

Wiring diagram PIR 180 /2.20m flush-mounted WDE002959 PIR 180 /2.20m flush-mounted WDE002959 Room 1 Room 2 System component Lighting control Presence detection Presence detection Power supply Switch actuator REG-K/2x230/16 with manual mode MTN647393 L N Room 1 Room 2 things work together

Configuration The ETS tool is used to set the parameters for the devices in the application and to define the functional relationship between the devices by group addresses. The following parameters and group address relations must be set and assigned. The parameters should be set first and in the described order. The parameters which can be changed to fine tune the application are described further on. PIR 180 /2.20m (Room1) 0 Switch object 1 Block 1 1 bit > 1/1/1 109 Status feedback Safety pause 1 bit < 1/1/2 Block 1 general > Brightness Brightness threshold (10-2000 Lux): 300 Block 1 general > Times Time base for staircase timer: 1 min Time factor for staircase timer (1-255): 25 PIR 180 /2.20m (Room2) 0 Switch object 1 Block 1 1 bit > 1/1/11 109 Status feedback Safety pause 1 bit < 1/1/12 Block 1 general > Brightness Brightness threshold (10-2000 Lux): 300 Block 1 general > Times Time base for staircase timer: 1 min Time factor for staircase timer (1-255): 25 Switch actuator REG-K/2x230/16 1/1/1 > 0 Switch object Channel 1 1 bit 1/1/2 < 3 Status feedback Channel 1 1 bit 1/1/11 > 4 Switch object Channel 2 1 bit 1/1/12 < 7 Status feedback Channel 2 1 bit Device selection Device selection: Channel 1: General Status information: Relay state after bus voltage recovery: Channel 2: General Status information: Relay state after bus voltage recovery: 2-fold switch actuator active status resp. object opened active status resp. object opened settings Group addresses Address Name (proposal) Function 1/1/1 Room 001 Light On/Off Light on/off by the movement detector 1/1/2 Room 001 Light Status Feedback from actuator, On/Off 1/1/11 Room 002 Light On/Off Light on/off by the movement detector 1/1/12 Room 002 Light Status Feedback from actuator, On/Off

Fine tuning Some parameters can be changed to fine tune the solution to the building and specific requirements. Parameter which may need to be adjusted are listed below, our recommendation in brackets. PIR 180 /2.20m: The staircase timer (delay time) will be retriggered by every detected movement when the light is on. The light will be switched off if no movement has been detected within the specified time. Parameter page Parameter Value Block 1 general > Times Time base for staircase timer 1s-1h (1 min) Block 1 general > Times Time factor for staircase timer 1-255 (25) fine tuning Delay time = Time base x Time factor The light will only be switched ON by movement if the brightness in the room is below the specified brightness threshold. Note that the brightness is measured at the installation place of the detector. Parameter page Parameter Value Block 1 general > Brightness Brightness threshold 10-2000 lux (300) Power failure behaviour Relay state after bus voltage failure: no change (relay remains) Relay state after bus voltage recovery: opened (light is OFF)

User manual The user manual provided for the application is an end users training material and can be installed at site when final submissions made. Please do no forget to cut out this quick guide for the user and attach to the wall next to the entrance to the room. Also, make sure the customer is aware of the installed applications function. Quick guide THIS ROOM IS EQUIPPED WITH AN AUTOMATIC MOVEMENT DETECTOR. Automatic mode operation The light is automatically switched ON when a person enters the room and the brightness value is below a predefined brightness threshold. It is automatically switched OFF when no movement is detected in the room and preset delay time has passed. Delay time is adjustable by ETS software. Default is 25 min. The brightness threshold is also adjustable by ETS software. Default is 300 lux. 06-10 Application 3.0.0.0.0.4 service for your customer ISC02072_EN