Precision humidity/temperature control/sensing

Similar documents
Precision humidity/temperature sensing/control

A C C U R A C Y B Y D E S I G N

Precision temperature control/sensing

CDD4 Series Room CO2 Transmitter Installation Instructions

CDD Carbon Dioxide Transmitter

CDD4 Duct Carbon Dioxide Transmitter

BA/BS4S Temperature Sensor Installation & Operating Instructions

PS-AULDP Series. Overview. Applications. Features & Benefits. Datasheet. Ultra Low Air Differential Pressure Transmitters

Humidity transmitter for critical climate applications

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

InBin-P Pressure switches from 5 Pa Pa

HT Series Wall Mount with Relay Setpoints, LCD, and Humidistat and Thermostat Control

Zone Pressure Touch (ZPT) Sensor - Standard Range

HT Series Wall Mount with Analog Setpoints, LCD, and Humidistat and Thermostat Control

Zone Pressure Touch Sensor - Standard Range

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

PTU300 Combined Pressure, Humidity and Temperature Transmitter

DP DP2500 DP0250

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

LAUREL ELECTRONICS, INC.

DP2500 DP0250. Differential Pressure Transmitter. Product Bulletin

InCos-P Pressure sensor 20 Pa Pa

Schneider Electric s SCD series of duct mount sensors measure the levels of CO 2. , RH (if equipped) and temperature of air inside a duct.

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

DMT345 and DMT346 Dewpoint Transmitters

C7110C1001A / C7110D1009A WALL MODULES

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

HWS Series Wall Mount with Relay Setpoints, LCD, and Humidistat Control

The industrial humidity transmitter

CTR21, CTR22, CTR23, and CTR24 Wall Modules

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

Measure & Control Temperature & CO2 levels with analog & digital I/O

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

Basic Temperature and Limit Controllers

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

The industrial humidity transmitter

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Trident and Trident X2 Digital Process and Temperature Panel Meter

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

TPE 1464 Series Pressure Transducer

Basic Temperature and Limit Controllers. Provide Economical Solution for a Wide Range of Applications SPECIFICATION SHEET

HygroClip M22 Series. 2-wire loop powered humidity temperature transmitters INSTRUCTION MANUAL

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

Product Manual SZ2144

H7625B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors

Ease of Use. Data at Your Fingertips LMS PHARMA

THERMOSTATS & CONTROLLERS

LLR-MOD Modbus Light Level and Occupancy Sensor

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

Humidity goes Digital

T7560A,B,C Digital Wall Module

H290 HUMIDITY TRANSMITTER INSTRUCTION MANUAL

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

CAEL-DP Series Dew Point Transmitter for Industrial Control

M-series Intrinsically Safe I/O

Product Manual SZ2141

ECP-VAV Series. ECP-VAV Series. 10-Point Single Duct VAV / VVT Free Programmable Controller. Applications. Features

EE80 Series. HVAC Room Transmitter and Switches for CO 2, Relative Humidity and Temperature EE80. Applications. Typical

DPR 100 A/B Analog Scales

TOXALERT MODEL AIR 2000

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

AIR41 Series IAQ Transmitter Installation Instructions

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

AIR QUALITY/ GAS DETECTION

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

UNIVERSAL TEMPERATURE TRANSMITTER

Temperature controller Ducted systems

TM-2100 Series Room Command Module

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service

FX06 Field Controller

TC-9102 Terminal Controller

LX Series Remote Input/Output (I/O) Controller

MMT330 Series Moisture and Temperature Transmitters for Oil

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

testo Probe series testo 661x The industrial humidity transmitter We measure it. SPECIFICATIONS testo Probe series testo 661x

Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication.

H7625A, H7635A Humidity/Temperature Sensors

EE75 Series. High-Precision Air / Gas Velocity Transmitter for Industrial Applications. Model A. Model B. Model C. Typical Applications.

T7560A,B,C Digital Wall Module

CLEAN ROOM PANEL - CRP5

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

AM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

Digital Indicator Solutions

DBC 150/650 Series. Druck Dry Block Temperature Calibrators. GE Sensing. Features

FUME HOOD CONTROLLER (FHC)

Carbon Monoxide (CO) Gas Detection and Control System

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

Advanced Test Equipment Rentals ATEC (2832) HMP45A&HMP45D HUMIDITY AND TEMPERATURE PROBES Operating Manual

Fast Route to Reliable Energy Savings ZIP Economizer

TM-2100 Series Room Command Module

HLX75 Series. High-Precision Air / Gas Velocity Transmitter for Industrial Applications. Model A. Model B. Model C

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe

Transcription:

HIGH ACCURACY HUMIDITY/TEMPERATURE TRANSMITTER HAHT Series Precision humidity/temperature control/sensing FEATURES: Highly stable RH sensor element Humidity range: 0-100% Accuracy available 1% & 2% High Accuracy Platinum RTD for Temperature AC/DC operation Peace of mind through reliable humidity monitoring GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM

DESCRIPTION: The HAHTRC Humidity/Temperature transmitter incorporates two sensors in one attractive wall mount enclosure for the most efficient environmental monitoring and control system. It uses a field-proven RH sensor to monitor relative humidity and a high accuracy, curve-matched thermistor to measure temperature and provides two analog outputs of either 4-20 ma, 0-5Vdc or 0-10 Vdc. Additional options include an occupancy override button, a communication jack, a fan speed switch or a LCD display. SPECIFICATIONS: RH Sensor... Thermoset polymer based capactive Accuracy... ±1% RH (20 to 80% RH) or ±2% RH (5 to 95% RH) Range... 0 to 100% RH non-condensing Temperature Compensation... 0 to 50 C (32-122 F) Hysteresis... ± 3% RH Response Time... 15 seconds typical Stability... ±1.2% RH typical @ 50% RH in 5 years Offset... ±20% RH, programmable Temperature Sensor... Curve-matched thermistor Accuracy... ±0.1 C (±0.18 F) Range... 0 to 35 C (32 to 95 F) or 0 to 50 C (32 to 122 F), programmable Power Supply... 24 Vac/dc ±10% (non-isolated half-wave rectified) Consumption... 60 ma max @ 24 Vdc Input Voltage Effect... Negligible over specified operating range Output Signal... 4-20 ma active (sourcing), 0-5 Vdc or 0-10 Vdc Output Drive @24 Vdc... 550 ohm max. for current, 10K ohms min. for voltage Output Resolution... 10 bit PWM Protection Circuitry... Reverse voltage protected and output limited Operating Conditions... 0 to 50 C (32-122 F), 0-95% RH non-condensing Programming/Selection... Via intenal push buttons and on-screen menu Wiring Connections... Screw terminal block (14 to 22 AWG) Enclosure Size... 84mmW x 119mmH x 29mmD (3.3 x 4.7 x 1.15 ) OPTIONS: LCD DISPLAY Range... 00.0 to 99.9, 3 digit Symbols... C, F, %RH Display Size... 38.1 x 16.5 mm (1.5 x 0.65 ) Digit Height... 11.43 mm (0.45 ) Backlight... Enable/disable via menu OVERRIDE Type... Front panel, momentary push-button, 2 wire dry contact Switch ratings... N.O., SPST, 50 ma @12 Vdc FAN SPEED SWITCH Type... Side panel mount, 5 postion switch Range... Off, Auto, Low, Medium, High Signal... Resistance: 0, 2, 4, 6, 8 KΩ (Custom ranges available) NETWORK COMMUNICATIONS 3.5mm phono jack... Ring/Mid/Tip connections to a 3-pin terminal block

PRODUCT ORDERING INFORMATION: MODEL Product Description HAHTRC Room Humidity/Temperature Transmitter RH Accuracy 1 1 % 2 2 % N L LCD Display Concealed Viewable I V Output 4-20 ma 0-5 Vdc or 0-10 Vdc (Jumper selectable) S J F Options (Multiple selections may be made) Override switch (Includes occupied input) Communication jack (3.5 mm phono) Fan speed switch HAHTRC 2 N I - - Typical Model Number Greystone Energy Systems, Inc. reserves the right to make design modifications without prior notice. PCB/WIRING INFORMATION Terminal Function DOWN POWER COMMON OCC IN TEMP OUT RH OUT UP SWITCH SWITCH + SWITCH - FAN + FAN - TIP MID RING MENU POWER COMMON OCC IN TEMP Output RH Output SWITCH + SWITCH - FAN + FAN - TIP MID RING From +24 Vac/dc of controller or power supply To GND or COMMON of controller To digital output of controller To analog input of controller 4-20 ma or 0-5 Vdc or 0-10 Vdc To analog input of controller 4-20 ma or 0-5 Vdc or 0-10 Vdc To digital input of controller To GND or COMMON of controller To analog input of controller Resistance input To GND or COMMON of controller External Jack TIP (tip of plug) connection External Jack MID (middle of plug) connection External Jack RING (base of plug) connection 0001299 * Some models do not have all these features **To save on number of connection wires, all GND or COMMON may connected together. ***Illustration shows standard wiring configuration. Custom configurations are available. Please contact Greystone.

DESCRIPTION: The HAHT series of high accuracy humidity/temperature transmitters are designed for use in environmental monitoring and control systems where high performance and stability are demanded. It s state-of-the-art design combines digital linearization and temperature compensation with a world class capacitive humidity sensor and platinum RTD for reliability and accuracy in even the most critical applications. Various models cover many aspects of RH and temperature measurement and several optional features are available to meet virtually all HVAC applications. SPECIFICATION: Humidity Sensor Type...Thermoset Polymer based capacitive Accuracy...±1% (20 to 80% RH) or ±2% (5 to 95% RH) Measurement Range...0 to 100% RH Temperature Dependence...±0.05% RH/ C Hysteresis...±1.5% RH maximum Repeatability...±0.5% RH typical Linearity...±0.5% RH typical Sensor Response Time...15 seconds typical Stability...±1% RH typical at 50% RH in 5 yrs. Temperature Sensor Type...1000Ω Platinum, IEC 751, 385 Alpha, thin film Temperature Sensor Accuracy...RTD Class A: ±0.15 C @ 0 C RTD 1/3 DIN: ±0.1 C @ 0 C RTD 1/10 DIN: ±0.03 C @ 0 C Accuracy... ±0.25% of span Operating Temperature...-40 to 85 C (-40 to 185 F) for HAHTD/HAHTO Operating Humidity...0 to 95% RH non-condensing Power Supply...18 to 35 Vdc, 15 to 26 Vac (RH110B is Vdc only) Consumption...22 ma maximum Input Voltage Effect...Negligible over specified operating range Protection Circuitry...Reverse voltage protected and output limited Output Signals...4-20 ma, 0-5 or 0-10 Vdc Output Drive at 24 Vdc...550 ohms max for current output 10K ohms min for voltage output Internal Adjustments...Clearly marked ZERO and SPAN pots Wiring Connections...Screw terminal block (14 to 22 AWG) Enclosures...HAHTDA (Grey ABS, UL94-V0), IP61 (Nema 2),114x84x53mm (4.5 w x 3.3 h x 2.1 d) HAHTOA (Grey ABS, UL94-V0 WP) IP65 (Nema 4X),145x100x64mm (5.7 w x 3.95 h x 2.5 d) HAHTDC/OC(PVC WP) IP65 (Nema 4X),126x100x74mm (4.97 w x 3.95 h x 2.9 d) HAHTD Probe...230 mm (9 ) probe length x 12.7 mm (1/2 ) diameter stainless steel with porous filter

DUCT/OUTSIDE HUMIDITY/TEMPERATURE PRODUCT ORDERING INFORMATION MODEL Product Description HAHTD Duct HAHTO Outside Air A C Enclosure ABS Enclsoure PVC Enclosure Accuracy 01 1% 02 2% Temperature Sensor 18 1000 Ω Platinum, IEC 751, 385 Alpha, thin film, Class A 48 1000 Ω Platinum, IEC 751, 385 Alpha, thin film, 1/3 Din 22 1000 Ω Platinum, IEC 751, 385 Alpha, thin film, 1/10 Din 2A 2D 2E Output Signals (RH and Temperature) 4-20 ma 0-5 Vdc 0-10 Vdc Transmitter Temperature Span Range 1 0 C - 35 C (32 F - 95 F) 2 0 C - 50 C (32 F - 122 F) 3 0 C - 100 C (32 F - 212 F) 6-50 C - 50 C (-58 F - 122 F) HAHTD A 03 18 2A 1 Greystone Energy Systems, Inc. reserves the right to make design modifications without prior notice. DIMENSIONS: 84 mm 3.3 29 mm 1.15 58 mm 2.3 119 mm 4.7 82.6 mm 3.25

DIMENSIONS: HAHTDA Mounting Holes (X2) Ø 0.200 115.8 mm 4.56 84.3 mm 3.320 2X Ø 0.850 53.6 mm 2.110 HAHTOA 145 mm 5.7 114.3 mm 4.5 64 mm 2.5 88.9 mm 3.5 100 mm 3.95 HAHTDC & HAHTOC 100 mm 3.93 87 mm 3.44 126 mm 4.97 114 mm 4.48 ENERGY SYSTEMS INC Greystone Energy Systems Inc. 150 English Drive, Moncton, New Brunswick, Canada E1E 4G7 (506) 853-3057 Fax: (506) 853-6014 North America: 1-800-561-5611 e-mail: mail@greystoneenergy.com www.greystoneenergy.com Mounting Holes (X4) Ø 0.200 Mounting Holes (X4) 6mm Ø 0.24 74 mm 2.9 Greystone Energy Systems Inc. is one of North America s largest ISO registered manufacturers of HVAC/R sensors and transmitters for Building Automation Management Systems. We have conscientiously established a worldwide reputation as an industry leader by maintaining leadingedge design technology, prompt technical support, and a commitment to on-time deliveries. We take pride in our Quality Management System which is ISO 9001 certified, assuring our customers of consistent product reliability. GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM PRINTED IN CANADA Copyright Greystone Energy Systems Inc. All Rights Reserved PB-HAHT-01-01 07/17