Solid-state Timer. Mounting system contact t contact. t Surface mounting/ track mounting

Similar documents
ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

Solid-state Timer H3YN

H3CR-H. Solid-state Power OFF-delay Timer. Ordering Information. DIN 48 x 48-mm Solid-state Power OFF-delay Timer

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

H3CA-8H-AC/100/110/120

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Model Number Structure

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

Solid-state Counter. Power supply Output No voltage input (short/open circuit) Voltage input (high/low voltage) 30 cps 1 kcps 30 cps 1 kcps AC

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

H3CR-F H3CR-F8 H3CR-F-300 H3CR-F8-300

Digital Timer. Ordering Information. 1/16 DIN, Quartz Timer with Four-Digit LED Display

Solid-State Counter/Timer

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

Model Number Structure

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1

Voltage Current Front-mounting bracket

Model Number Structure

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit)

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

Model Number Structure

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

DIN Track Mounted, Standard 22.5-mm Width Timer Range

Switching Power Supply

Model Number Structure

Temperature Controller E5C4

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

Solid-state Timers H3DK

Inductive Proximity Sensor

Solid-state Timers H3DK

Ex. H3Y-2-C 110 VAC 30 s Rated time Supply voltage 2. Sockets and Hold-down Clips are not included with the H3Y. They must be ordered separately.

Model Number Structure

Model Number Structure

Self-Powered Counters H7EC

Thread length (overall length) material

Model Number Structure

Special-Purpose Proximity Sensor E2C

Switching Power Supply

Common to all H3DS. Installation of Screw-Less Clamp Models. Tools. Applicable Wires. Applicable Screwdriver. Applicable Wire Sizes

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

S8VE (60/90/120/180/240-W Models)

H7ER H7ER-V H7ER-V1 H7ER-V2 H7ER-V3

Model Number Structure

Inductive Proximity Sensor

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

Conductive Level Controller

Model Number Structure

Model Number Structure

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features

Digital Timer Ultra-compact Timer Provides Advanced Functions and Security Settings. Features

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Switch Mode Power Supply

Type High-sensitivity. Medium-sensitivity models models Sensed current 30 ma (fixed) 100 ma/200 ma 200 ma/500 ma 500 ma/1,000 ma Operating time

E4PA. Ultrasonic Displacement Sensor. Ordering Information

Cylindrical Proximity Sensor

7. Approved Standards US: UL, CSA UL: FILE No.E CSA: FILE No.LR31928) 8. Special Function None : Standard U : For ultrasonically cleanable

Digital Counter H7CZ. Easy to Use and Easy to Read. Features. Basic Features Better Readability Character Height of 10 mm with a Wide Viewing Angle.

Model Number Structure

Model Number Structure

Mini Photoelectric Sensor

Safety Relay Unit (I/O Unit Type)

Cam Positioner H8PS. Plastic body, 2 m (6.56 ft.) cable Metal body, 2 m (6.56 ft.) cable

SPST-NO SPDT DPST-NO DPDT

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

H7BX CSM_H7BX_DS_E_4_4

Multifunction Counter/Tachometer H7CX Series

Solid-state timer Compact, Multi-function Timers for G2R Relay Socket. Model Number Structure. Ordering Information. Model Number Legend

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function.

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

3. Input KJ: Thermocouple P: Platinum resistance thermometer T: Thermocouple/platinum resistance thermometer (universal-input)

Model Number Structure

Three-phase Phase-sequence Phase-loss Relay

Digital Timer H5CZ. Easy to Use and Easy to Read. Features. Basic Features Better Readability Character Height of 10 mm with a Wide Viewing Angle.

DIN 48 x 48 Multifunction Counter/Tachometer with a Bright, Easy-to-view Negative Transmissive LCD. The H7CX Defines a New Standard.

Model Number Structure

Model Number Structure. Cam Positioner H8PS. Model Number Legend

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0.

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

TIMERS FOR ALL APPLICATIONS

SRT2-ROC08, SRT2-ROC16

Model Number Structure

Special-purpose Basic Switch

Single-phase Voltage Relay

I/O delay. (0.32 in ±0.06 in)

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Solid State Relays with Failure Detection Function

Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range.

G3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Model Number Structure. Ordering Information. Switch Mode Power Supply S82K (3/7.5/15/30/50/90/100-W Models) Model Number Legend.

Multifunction Preset Counter H7CX

Transcription:

Solid-state Timer DIN-sized (48 x 48, 45 x 75 mm) Timer with Digital Setting and LCD Display Dual power supplies for free AC/DC. Eight operation modes selectable with one unit. Any desired time can be set digitally within a range from 0.1 seconds to 9,990 hrs. Four external signal inputs. ON/OFF indicator for control output and bar indicator for remaining time. Conforms to UL, CSA, and CE marking. Ordering Information Operation/resetting Operation mode Terminal Time-limit Instantaneous Mounting system contact t contact t Surface mounting/ track mounting Flush mounting Time-limit operation/ self-resetting/external 8 operation modes 11-pin round socket SPDT --- -A -A resetting (see note 2) (selectable) (see note 3) Front screw -FA --- Time-limit operation/ ON-delay 8-pin round DPDT --- -8-8 self-resetting operation socket SPDT SPDT -8H -8H Note: 1. Specify both the model number and supply voltage when ordering for the -8H and -8. 2. The operation/resetting system depends on the selected operation mode. For details, see Timing Chart. 3. The 8 operation modes are as follows: A: ON-delay operation B: Repeat cycle operation C: Signal ON/OFF-delay operation (1) D: Signal OFF-delay operation (1) Accessories (Order Separately) E: Interval operation F: One-shot and flicker operation G: Signal ON/OFF-delay operation (2) H: Signal OFF-delay operation (2) Timer Track mounted socket Back connecting socket (see note 1) Solder terminal Screw terminal -A P2CF-11 PL11 P3GA-11-8H/-8 P2CF-08 PL08 P3G-08 Note: Track mounted socket can be used as a front connecting socket. Specifications Time Ranges A desired time can be set within a range of 0.1 s to 9,990 hrs by combining the three thumbwheel switch modules for time setting and one module for time unit selection. Time unit 0.1 s 1 s 0.1 min 1 min 0.1 hrs 1 hr 10 hrs Time range 1 to 999 (3 digits) 1

Ratings Rated supply voltage Item -A/-FA -8-8H Operating voltage range Power consumption 24 to 240 VAC (50/60 Hz), 12 to 240 VDC (permissible ripple: 20% max.) 90% to 110% of rated supply voltage AC: approx. 4 VA DC: approx. 2 W 100/110/120, 200/220/240 VAC, (50/60 Hz), 24 VDC, 110 VDC (permissible ripple: 20% max.) (see note) 85% to 110% of rated supply voltage AC: approx. 10 VA/1 W DC: approx. 1 W Control outputs 3 A at 250 VAC, resistive load (cosφ = 1) Note: Single-phase, full-wave rectified power sources may be used for 24 to 240 VDC. Characteristics AC: approx. 10 VA/1.5 W DC: approx. 2 W Accuracy of ±0.3% ±0.05 s operating time Influence of voltage Influence of temperature Setting error ±0.5% ±0.05 s max. Reset time -A/-FA: 0.5 s max. -8H/-8: 0.1 s max. Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts and between contact and control circuit) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts) Impulse withstand 3 kv voltage Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm double amplitude for 1 h each in three directions Malfunction: 10 to 55 Hz with 0.5-mm double amplitude for 10 min each in three directions Shock resistance Destruction: 980 m/s 2 Malfunction: 98 m/s 2 Ambient temperature Operating: 10 C to 55 C Ambient humidity Operating: 35% to 85% Life expectancy Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (3 A at 250 VAC, cosφ = 1 at 1,800 operations/h) See Lift-test Curve for more details. Approved standards UL508, CSA C22.2 No. 14, LR, NK Conforms to EN61010-1. EMC (EMI) EN61326 Emission Enclosure: EN55011 Group 1 class A Emission AC mains: EN55011 Group 1 class A (EMS) EN61326 Immunity ESD: EN61000-4-2: 4 kv contact discharge (level 2) 8 kv air discharge (level 3) Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3); 10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (according to EN61000-6-2) Immunity Burst: EN61000-4-4: 2 kv power-line (level 3); 1 kv I/O signal-line (level 4) Immunity Surge: EN61000-4-5: 1 kv line to lines (power and output lines) (level 3); 2 kv line to ground (power and output lines) (level 3) Immunity Voltage Dip/Interruption EN61000-4-11: 0.5 cycle, 100% (rated voltage) Weight -A: approx. 110 g -FA: approx. 190 g 2

Engineering Data Life-test Curve Switching operations (x 10 3 ) Load current (A) Reference: A maximum current of 0.15 A can be switched at 125 VDC (cosφ = 1). Maximum current of 0.1 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected. Note: 1. The Series has been tested for the following: impulse voltages, noise (via noise simulator, for L loads, and for relay oscillation), and resistance to static electricity. 2. Minimum applicable load (P reference values): -A(FA), -8H: 100 ma at 5 VDC -8: 10 ma at 5 VDC Nomenclature -A/-8H -FA Time Unit Selector LCD Display LCD Display Control output ON/OFF indication Remaining time elapses, the remaining time is indicated by a pattern of bars in tenth of 1/10 of the set time. Set Time Indicators (3 Digits) Operation Mode Selector (Fixed to A in -8H) A: ON-delay operation B: Flicker operation C: Signal ON/OFF-delay operation (1) D: Signal OFF-delay operation (1) E: Interval operation F: One-shot and flicker operation G: Signal ON/OFF-delay operation (2) H: Signal OFF-delay operation (2) Operation Mode Selector Time Unit Selector Set Time Indicators (3 Digits) 3

Operation Timing Chart -A (FA) ON-delay Operation (A Mode) Signal Start Power-ON Start/Power-OFF Reset t: Set time; R: Resetting time; t-a: Time within the set time t: Set time; t-a: Time within the set time Note: The minimum signal input time is 0.05 s. Flicker Operation (B Mode) Signal Start Power-ON Start/Power-OFF Reset t: Set time t: Set time; t-a: Time within the set time Note: The minimum signal input time is 0.05 s. 4

Signal ON/OFF-delay Operation 1 (C Mode) Signal OFF-delay Operation 1 (D Mode) t: Set time; t-a: Time within the set time t: Set time; t-a: Time within the set time Note: 1. The minimum signal input time is 0.05 s. 2. Operation 1 refers to the version in which the output relay operates when the Start signal is ON. Interval Operation (E Mode) Signal Start t: Set time t: Set time; t-a: Time within the set time Note: The minimum signal input time is 0.05 s. One-shot and Flicker Operation (F Mode) Signal Start Power-ON Start/Power-OFF Reset t: Set time; t-a: Time within the set time t: Set time; t-a: Time within the set time Note: The minimum signal input time is 0.05 s. Note: The minimum signal input time is 0.05 s. Signal ON/OFF-delay Operation 2 (G Mode) Signal ON/OFF-delay Operation 2 (H Mode) t-a t: Set time; t-a: Time within the set time t: Set time; t-a: Time within the set time Note: 1. The minimum signal input time is 0.05 s. 2. Operation 2 refers to the version in which the output relay does not operate when the Start signal is ON. 5

How to Use Gate Signal Input How to Use Check Signal Input If a check signal is input to the timer during the lapse of a set time, the remaining set time will become 0 and the timer will enter the next control state. Also, while a check signal is being input, the elapsed time measurement of the set time is not performed. ON-delay Operation Note: 1. This timing chart indicates the gate input in operation mode A (ON-delay operation). 2. The set time is the sum of t 1 and t 2. t: Set time; t-a: Time within the set time Repeat Cycle Operation -8H t: Set time; t-a: Time within the set time 6

Dimensions Note: All units are in millimeters unless otherwise indicated. Timers -A/-8H -FA Panel Cutouts When mounting a single unit t = 1 to 3.2 mm Horizontally connecting n units No front cover: N = (48n 2.5) +1 / 0 With front cover: N = {48n 2.5 + (n 1) x 3} +1 / 0 (N) Mounting Holes Two,M4 or 4.5 dia. holes Note: When mounting two or more timers in line, dimension L between two adjacent timers should be 10 mm min. Accessories (Order Separately) Track Mounted Front Connecting Socket P2CF-11 Eleven, M3.5 x 7.5 sems Terminal Arrangement (Top View) Mounting Holes Mounting Height of Timer with Socket Two, 4.5 dia. holes Two, 4.5 dia. mounting holes 108.1 Note: P2CF-11 can be used as a front connecting socket. P2CF-08 Eight, M3.5 x 7.5 sem Terminal Arrangement (Top View) Mounting Holes Mounting Height of Timer with Socket Two, 4.5 dia. holes Two, 4.5 dia. or Two, M4 97.2 Note: P2CF-08 can be used as a front connecting socket. 7

Back Connecting Socket P3GA-11 27 dia. Terminal Arrangement (Bottom View) P3G-08 Terminal Arrangement (Bottom View) Mounting Height of Timer with Socket 10.9 86.3 M3.5 P3G-08 PL11 Terminal Arrangement (Bottom View) Mounting Holes Mounting Height of Timer with Socket Two, 2 dia. holes Two, 3.5 dia. or M3 socket mounting holes 79.6 Hold-down clip Y92H-1 35 max. Approx. 20.5 PL08 Terminal Arrangement (Bottom View) Mounting Holes Mounting Height of Timer with Socket Two, 2 dia. holes Two, 3.5 dia. or 3M socket mounting holes 79.6 8

Mounting Track (Meets DIN EN50022) PFP-100N/PFP-50N PFP-100N2 Twelve, 25 4.5 elliptic holes (see note) (see note) Note: This dimension applied to PFP-50N. Note: A total of 12-25 x 4.5 elliptic holes are provided with 6 holes cut from each rail end at a pitch of 10 mm between holes. End Plate PFP-M PFP-S Adapter for Flush Mounting Y92F-30 Note: Pay attention to the orientation of the adapter when mounting two or more timers in a vertical or horizontal line. Protective Cover Y92A-48B/Y92A-48D The protective cover protects the front panel, particularly the time setting section, against dust, dirt and water drip, as well as prevents the set value from being altered due to accidental contact with the time setting knob. Y92A-48B Hard Plastic Cover Y92A-48D Soft PVC Cover Note: The Y92A-48B Protective Cover is made of a hard plastic and therefore, must be removed to change the timer set value. However, since the Y92A-48D Protective Cover is made of PVC, the set value can be altered by pressing on the surface of the cover. It may be, however, difficult to make setting changes of the Timer with the Y92A-48B Protective Cover attached, which must be taken into consideration before using the Y92A-48B Protective Cover. When attaching the Y92A-48A to the Timer to be panelmounted, use the Y92F-30 Mounting Adapter along with the Timer. The Protective Cover cannot be, however, used for the -FA Series. 9

Installation Terminal Arrangement -A -FA or ( ) * * * * or ( ) (See note 2) * * * * (See note 2) Note: 1. *C: Check: *G: Gate: *S: Start: *R: Reset: 2. Conventional time-limit contacts are symbolized as. However, the contacts of -A are symbolized as because timer has 8 operation modes. Note: 1. *C: Check: X-E1 *G: Gate: X-D1 *S: Start: X-C1 *R: Reset: X-B1 2. Conventional time-limit contacts are symbolized as. However, the contacts of -FA are symbolized as because timer has 8 operation modes. Input Connections Signal Inputs Connect the start input contact between terminals and, the reset input contact between terminals and, the gate input contact between terminals and, and the check input contact between terminals and. Solid-state Signal Inputs Connect the start input transistor between terminals and, the reset input transistor between terminals and, the gate input transistor between terminals and, and the check input transistor between terminals and. For each signal input contact, use a gold-plated contacts with high reliability. Be sure that these input signals satisfy the following requirements: a resistance of 1 kω (max.) and a residual voltage of 1 V (max.) when the contact is made. For signal input, use an open collector type transistor with characteristics: V CEO = 20 V min., V CE(S) = 1 V max., IC = 50 ma min. and I CBO = 0.5 µa max. In addition, be sure that the input signals satisfy the following requirements: a resistance of 1 kω (max.) and a residual voltage of 1 V (max.) when the transistor is ON, and a resistance of 200 kω (min.) when the transistor is OFF. 10

From a solid-state circuit (proximity sensor, photoelectric sensor, or the like) with rated power supply voltage ranging from 6 to 30 VDC, input signals can also be applied by other than an open collector type transistor as shown in the following diagram. The input signal from a solid-state circuit is applied when output transistor Tr turns ON. In terms of signal voltage, the signal is input when it goes from a high to low level. Again, the residual voltage should be 1 V (max.) when the transistor is ON. As the current output from the timer to Tr is approximately 0.1 ma, this connection is possible provided the residual voltage is kept to a maximum of 1 V. Solid-state circuit (proximity sensor, photoelectric sensor, etc.) Note: Except for the power supply circuitry, avoid the laying of input signal wires in parallel or in the same conduit with hightension or power lines. It is recommended to use shielded wires or wiring with independent metal conduits for the shortest possible distance. -8H -8 ( ) ( ) 11

Application Examples Standard type is used for the following application examples. In the schematic diagrams, each thick the indicates the wiring necessary for selecting the desired operation mode. ON-delay Operation (A Mode) Power-ON Start/Power-OFF Reset Signal Start/Signal Reset Flicker Operation (B Mode) Power-ON Start/Power-OFF Reset Signal Start/Signal Reset Signal ON/OFF-delay Operation 1 (C Mode) Signal ON/OFF-start/Instantaneous Operation/ Time-limit Reset Signal OFF-delay Operation 1 (D Mode) Signal Start/Instantaneous Operation/Time-limit Reset t-a t: Set time, t-a: Time within the set time 12

Signal ON/OFF-delay Operation 2 (G Mode) Signal ON/OFF-start/Instantaneous Operation/ Time-limit Reset Signal Start/Signal Reset Interval Operation (E Mode) Power-ON Start/Power-OFF Reset Signal Start/Signal Reset One-shot and Flicker Operation (F Mode) Power-ON Start/Power-OFF Reset Signal OFF-delay Operation 2 (H Mode) Signal/Instantaneous Operation/Time-limit Reset 13

Precautions How to Change Operation Mode Operate the pushbuttons of the thumbwheel switch, located at the leftmost position on the front panel to set the operation mode. Eight operation modes (A, B, C, D, E, F, G, and H) are selectable and the selected operation mode is displayed in the operation mode display window. Note: The operation mode is fixed to A for -8H. How to Change Time Unit and Rated Time Operate the pushbuttons of the rightmost thumbwheel switch to select the desired time unit. Seven time units (0.1 s, s, 0.1 m, m, 0.1 h, h, or 10 h) are selectable and the selected time unit is displayed in the time unit display window. The desired rated time is specified by operating the three thumbwheel switches in the middle of the front panel. The range of rated time is 001 to 999 for each unit. Remaining time display The remaining time is displayed as a decreasing percentage between 0% and 100%. Connecting the Operating Power Supply The -8 contains a capacitor-drop power circuit. Use a sinusoidal power supply with a commercial frequency. Do not use power supplies with a high frequency component (such as inverter power supplies) for Timers with 100 to 240-VAC specifications. Using these power supplies can damage internal circuits. The power supply connections to the -A and -FA can be made without regard to polarity for both AC and DC power supplies; just connect to the specified terminals (2 and 10, or A1 and A2). When connecting a DC power supply to the -8 or -8H, however, the polarity must be connected as indicated. Although there is a wide range of power connectable to the -A and -FA, be sure that there is no inductive voltage or residual voltage applied to the timer power supply terminals (2 and 10, or A1 and A2) when the power switch is turned OFF. (Inductive voltage can be generated in the power supply line if it is placed in parallel with high-voltage or power lines.) A DC power supply can be connected if its ripple factor is 20% or less and the mean voltage is within the rated operating voltage range of the Timer. Connect the power supply voltage through a relay or switch in such a way that the voltage reaches a fixed value at once or the Timer may not be reset or a timer error could result. -8 and -8H Timers with AC specifications are equivalent to capacitor loads. When switching the Timer power supply with an SSR, use an SSR with a withstand voltage of twice the power supply voltage. Since the -8 and -8H Timers of AC specifications externally discharges a part of internal energy when the power is turned OFF, it may malfunction if an extremely sensitive relay is used with the following sequence circuit. If such a malfunction occurs, change the circuit configuration as shown below on the right side. X/a X/a Time unit selector T/b If malfunction is expected. T/b X/a Rated time display window 001 to 999 Rated time selector Time unit display window 0.1 s, s, 0.1 m 0.1 h, h, 10 h Time Unit and Rated Time Time unit Rated time 0.1 s 0.1 to 99.9 s s 1 to 999 s 0.1 m 0.1 to 99.9 m m 1 to 999 m 0.1 h 0.1 to 99.9 h h 1 to 999 h 10 h 10 to 9,990 h! Caution 1. Do not change the time unit, rated time, or operation mode while the timer is in operation. Otherwise, the timer may malfunction or be damaged. Be sure to turn off the power supply to the timer before changing the timer unit, rated time or operation mode. 2. Note that output will be generated in C, D, E, G, or H mode even if the rated time is set to 000. No output will be generated in A, B, or F mode. 14

Input/Output The operation of the output contacts varies with the operation specifications. Before making connections, check the operation specifications and operating conditions using the application examples provided. The -A and -FA do not use transformers. Simultaneous inputting power from two or more power supplies to separate timers or counters from a single input contact or transistor is not possible. For the power supply of an input device, use an isolating transformer, of which the primary and secondary windings are mutually isolated and the secondary winding is not grounded. -A/-FA Input terminal Power supply Circuit Rectifier circuit Isolation transformer is required. A transformer is not used in the power supplies for the -A and -FA. You can therefore receive an electrical shock by touching the input terminals when the power supply voltage is being applied. Take adequate precautions to protect against electrical shock. Inputs to input signal terminals are made by shorting the individual input terminals to the common terminal (terminal 3 for the -A or terminal (X) for the -FA). Internal circuits may be damaged if connections are made to any other terminals or if voltages are applied. If contacts are used to short the terminals, they will be switching a low voltage (approximately 5 VDC) and current (approximately 100 µa). You must therefore use high-reliability contacts with a contact resistance of 1 kω or less when shorted and residual voltage of 1 V maximum when shorted. The reset input will take priority if both the set and reset inputs are turned ON simultaneously. Others Holding relays are used for outputs on the -A Series. Dropping the Unit or otherwise subjecting it to shock can cause the relay to reverse or to move to the center position. How to Mount the Timer on Mounting Track When mounting a -FA Timer on a socket mounting track, observe the following procedures: Mounting First hook portion A of the timer to an edge of the track and then depress the timer in direction B. B A C Dismounting Pull out portion C with a round-blade screwdriver and remove the timer from the mounting track. 15

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. L032-E1-06C In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company Industrial Control Components Division Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7119/Fax: (81)75-344-7149 Printed in Japan 0802-1.5C (0696) 16