Precision digital measuring device PHYSICS 51

Similar documents
PHYSICS Digital Measuring Devices

Supplied with. Calibration certificate. HD 200 Hygrometer

Precision Hand-held Thermometer

Multi-functional precision thermometer CTR3000

The industrial humidity transmitter

ALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. ALMEMO V7 Measuring Instrument

ALMEMO Measuring Instruments

VAC analysis measuring instrument

HD32.7 HD HD [ GB ] 8-input Data Logger for Pt100 probes with SICRAM module

The industrial humidity transmitter

JUMO TDA-300 and JUMO TDA-3000 Handheld Thermometer with data logger

PTU300 Combined Pressure, Humidity and Temperature Transmitter

testo Probe series testo 661x The industrial humidity transmitter We measure it. SPECIFICATIONS testo Probe series testo 661x

DMT345 and DMT346 Dewpoint Transmitters

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

Humidity transmitter for critical climate applications

Hand-Held Thermometer Model CTH 6200

Next Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

THM501 PT100 MODBUS TEMPERATURE TRANSMITTER

Ultra-Accurate Measurement for Temperature and Voltage

C100 Portable Multifunction

WiFi data logger system

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4

Multiparameter Waterproof Meters. Multiparameter measurement in compact, IP67 rated waterproof enclosures

Next Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175

Hand-held thermometer Model CTH6200

EE80 Series. HVAC Room Transmitter and Switches for CO 2, Relative Humidity and Temperature EE80. Applications. Typical

AQ 200 AQ 200 Air Quality

GRUNDFOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers. For conductivity measurement (conductive, inductive)

GRUNDFOS ALLDOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers for conductivity measurement 50/60 Hz

CALYS 50. Field multifunction calibrator for basic use. Calibration measurement

Hanna Instruments HI9819X Multiparameter series

Input for universal probe* Inputs for thermocouple probes

ENVIRONMENTAL MONITORING & CONTROL

Hand-held thermometer Model CTH6200

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

Hand-held pressure indicator Model CPH6300-S1 (1-channel version) Model CPH6300-S2 (2-channel version)

Ultra-Accurate Measurement for Temperature and Voltage

Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291

Differential pressure measuring instrument

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

Hand-Held Pressure Indicator

Next Generation! Committing to the future. With the professional Testo data loggers, a new age begins for you. Logger series testo 174

HD2107.1, HD2107.2, HD2127.1, HD2127.2

DATA LOGGERS Reliable solutions for monitoring your processes

703 Laboratory Conductivity Meter

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

testo Probe series testo 661x The industrial humidity transmitter Committing to the future

Miles Ahead of the Competition!

ENVIRONMENTAL MONITORING & CONTROL

CONDUCTIVITY METER OPERATION MANUAL. Model : CD-4322

Analog input module. Data sheet. for MULTICAL 603

Multi Units Humidity/Temperature Transmitter. HygroViewer Model JW300 User Manual

Differential pressure measuring instrument

ProLab 1. ProLab 1000: ph for the professional. ph Meter ProLab 1000: Superior technique in a classy metal body. Precise measurements

Hand-held thermometer, precision version Model CTH6500 Model CTH65I0, Ex version

HI 9828 Multiparameter Water Quality Meter...

Measurement data monitoring system

Electrochemistry Meters. Series SD (IP 67 waterproof) Electrochemistry Meters

Portable low-pressure controller Model CPC2000

UNIVERSAL MONITORING SYSTEM MS5D, MS5

HI 9828 Multiparameter Water Quality Meter...

Anemometer, Hygrometer Light Meter, Thermometer

Differential pressure measuring instrument

Measurement data monitoring system

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

Handheld Water Quality Meters 100 Series

The Model 703 offers a wide range of practical features to meet the numerous requirements of everyday measuring tasks.

world class water monitoring series 42

How to build a Conductivity Measurement System

Thermometer T12. Precision Multichannel Thermometer System. Typical applications: REFLECTING YOUR STANDARDS

Humidity/Temperature Dataloggers

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

General information Engineering with Programming package. Display with display

ALMEMO Measuring Instruments

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

ALMEMO Measuring Instruments

SigmaCheck. Fully Featured Eddy Current Conductivity Meter ET NDE

Portavo 904 X Multi. Multiparameter Ex

WiFi data logger system

ph 8+ DHS ph- mv - Temperature GLP - USB Data Logger - RS232 printer

Ultra-Accurate Temperature Measurement Instruments

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

Portavo. Portavo. Applications

New products 2016 Measuring Instruments Meteorology Reference Measuring Instruments Input connectors and adapter cables

4 in 1 Anemometer, Humidity Light Meter, Thermometer

Supplied with. Calibration certificate. TM 200 Thermometer

Data Logger ALMEMO Operating Instructions V

Digital pressure gauge Data Sheet: DMM2.431.R1.EN

Clamp-On Digital Multimeters

Conductivity Transmitters

F %RH. %rf CO 2. g/m 3. inch H₂O. hpa. Measure. Record. Monitor. Choose the right data loggers for your application now.

Multiparameter Waterproof Meters. Multiparameter measurement in compact, IP67 rated waterproof enclosures

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

USER`S MANUAL Professional measuring instrument 4 in 1 ATE-9508

Transcription:

Precision digital measuring device PHYSICS 51 Digital measuring device for thermocouples, NTC resistance thermometers, infrared temperature probes, capacitive humidity probes. Technical data PHYSICS 51 Sensors: thermocouples, humidity, NTC Measuring input: 1 input channel Measuring range: see sensor list Galvanic isolation: Semiconductor relais (50 V) Channels: 4 function channels e.g. for dual probes AD converter: Delta-Sigma 15 bit, 2.5 M/s Resolution: max. 0,01 K Output: 2 output channels Display graphic: 2 lines, statical 7/16 segments Display illumination: 2 LEDs, white Keyboard: 7 silicone keys Batteries: 3 Mignon Alkaline Casing: ABS (max. 70 C), light grey Degree of protection: IP54 Dimensions and weight: L 127 x W 83 x H 42 mm, 290 g Ref-No.: 59235 Product features Compact shape and ergonomic design Measuring functions: measuring value, zero-setting, max.-/min. value documentation, 2-step adjustment, scaling (optional: multi-point calibration for temperature values) Test functions: segment monitoring, range monitoring, sensor error check, battery check Interfaces: USB, RS232, Ethernet, Bluetooth, analog Language selection: German, English, French Additional order-no.:.../03 with works certificate (for the measuring unit temperature).../04 with DAkkS certificate (for the measuring unit temperature)

Variable precision digital measuring device PHYSICS 100 Digital measuring device for precise measurements with a wide range of measuring units and sensor technologies, e.g. temperature (Pt100, thermocouples, NTC, infrared), air humidity, air flow, pressure, flow rate, electrical values etc. New! Beside the PHYSICS 100-1 type with one input channel we offer also type 100-2 with 2 input channels (both input channels or measuring points can be covered simultaneously. Technical data PHYSICS 100 Sensors: Thermocouples, resistance thermometers, humidity, pressure, NTC, conductivity, ph, Redox, CO, optical radiation and more Measuring input: 100-1: 1 input channel 100-2: 2 input channels Input channels for more than 65 measuring ranges Galvanic isolation: Semiconductor relais (50 V) Channels: 4 function channels e.g. for dual probes 4 internal functions (e.g. difference) AD converter: Delta-Sigma 16 bit, 2.5 or 10 M/s Probe voltage: Battery operation: 9 V, max. 150 ma Mains operation: 12 V, max. 150 ma Resolution: Output: max. 0.01 K 2 output channels for all output modules (analogue, data, trigger, relays cable, memory etc.) Display graphic: 2 lines, statical 7/16 segments Display illumination: 2 LEDs, white Keyboard: 7 silicone keys Internal RAM memory: 99 measuring values Memory plug: optional external memory for up to 25,000 values Batteries: 3 Mignon Alkaline Casing: ABS (max. 70 C), light grey Degree of protection: IP54 Dimensions and weight: L 127 x W 83 x H 42 mm, 290 g Bestell-Nr.: 63731 100-1 (1 input channel) 63874 100-2 (2 input channels) Product features Compact shape and ergonomic design Intelligent probe display with probe specific functions (cold-junction compensation etc.) Measuring functions: measuring value, zero-setting, max.-/min. value documentation, 2-step adjustment, scaling (optional: multi-point calibration for temperature values) Test functions: segment monitoring, range monitoring, sensor error check, battery check Interfaces: USB, RS232, Ethernet, Bluetooth, analog Language selection: German, English, French Additional order-no.:.../03 with works certificate (for the measuring unit temperature).../04 with DAkkS certificate (for the measuring unit temperature)

Highly variable precision digital measuring device PHYSICS 300 Complex digital measuring device with data logger function* for precise measurements with a wide range of measuring units and sensor technologies, e.g. temperature (Pt100, thermocouples, NTC, infrared), air humidity, air flow, pressure, flow rate, electrical values etc. Measurement units PHYSICS 300 mbar, Pa, lux, C, F, Hz, kj/kg, %H, ppm, ma, V, min, W/m², ms, bar, g/kg, m/s, ph Subject to type of probe 2, 3 or 4 input channels or measuring points can be covered simultaneously Technical data PHYSICS 300 Sensors: Measuring input: Thermocouples, resistance thermometers, humidity, pressure, NTC, conductivity, ph, Redox, CO, optical radiation and more 300-2: 2 input channels New! 300-3: 3 input channels * 300-4: 4 input channels * New! Input channels for more than 65 measuring ranges Galvanic isolation: Semiconductor relais (50 V) Channels: 4 function channels e.g. for dual probes 4 internal functions (e.g. difference) AD converter: Delta-Sigma 16 bit, 2.5 or 10 M/s Probe voltage: Battery operation: 9 V, max. 150 ma Mains operation: 12 V, max. 150 ma Resolution: Output: max. 0.01 K 2 output channels for all output modules (analogue, data, trigger, relays cable, memory etc.) Display graphic: 128 x 64 pixel, 8 lines Display illumination: 2 LEDs, white Keyboard: 7 silicone keys Internal memory: *only types 300-3 and 300-4: 59 kb EEPROM (ca. 12,000 values) Batteries: 3 Mignon Alkaline Casing: ABS (max. 70 C), light grey Degree of protection: IP54 Dimensions and weight: L 127 x W 83 x H 42 mm, 290 g Ref.-no.: 63884 300-2 (2 input channels) 59234 300-3 (3 input channels + datalogger function) 63885 300-4 (4 input channels + datalogger function Product features Compact shape and ergonomic design Intelligent probe display with probe specific functions (cold-junction compensation etc.) Measuring functions: measuring value, zero-setting, max.-/min. value documentation, 2-step adjustment, scaling (optional: multi-point calibration for temperature values) Test functions: segment monitoring, range monitoring, sensor error check, battery check Interfaces: USB, RS232, Ethernet, Bluetooth, analog Display free configurable (numeric or graphic design) Sleep mode for long-term documentations Language selection: German, English, French Additional order-no.:.../03 with works certificate (for the measuring unit temperature).../04 with DAkkS certificate (for the measuring unit temperature)

High-precise digital temperature measuring device PHYSICS 1000 Ludwig Schneider s high-precise digital measuring device PHYSICS 1000 offers highest resolution, accuracy and linearity for mains independent measurements. Resolution: 0,001 K With its ultra high resolution of 0.001 K this digital measuring device provides dependable and reproducible results of mobile temperature measurements in quality assurance, process monitoring and production control in the chemical, pharmaceutical and food industries as well as for research and development. Technical data PHYSICS 1000 Sensors: only resistance thermometers Pt100 Measuring input: 2 input channels Galvanic isolation: Semiconductor relais (50 V) Measuring range: -200 up to +400 C Self calibration: Zero point, measuring current Genauigkeit: 0,01 % of value ±3 digits Temperature drift: 0,003 %/ C AD converter: Delta-Sigma 16 bit, 2.5 M/s Resolution: 0,001 K / 0,01 K Output: 2 Ausgangsbuchsen USB, V24, Ethernet, Bluetooth Display graphic: 128 x 64 pixel, 8 lines Display illumination: 2 LEDs, white Keyboard: 7 silicone keys Internal RAM memory: 99 values Memory plug: optional external memory for up to 25,000 values Batteries: 3 Mignon Alkaline Casing: ABS (max. 70 C), light grey Degree of protection: IP54 Dimensions and weight: L 127 x W 83 x H 42 mm, 290 g Ref.-No.: 57089 Product features Compact shape and ergonomic design Measuring functions: measuring value, zero-setting, max.-/min. value documentation, 2-step adjustment, scaling (optional: multi-point calibration for temperature values) Test functions: segment monitoring, range monitoring, sensor error check, battery check Interfaces: USB, RS232, Ethernet, Bluetooth, analog Language selection: German, English, French Additional order-no.:.../03 with works certificate (for the measuring unit temperature).../04 with DAkkS certificate (for the measuring unit temperature)

Sensors for PHYSICS digital measuring devices Technical data Ref. For PHYSICS device type PHYSICS sensors No. 51 100 300 1000 Immersion resistance thermometer Pt100 Dia. 3 x 250 mm, cable length: 2 m, class A, temperature range: -90...+350 C / 0.01 C 59954 ü ü Insertion resistance thermometer Pt100 Dia. 4 x 150 mm, cable length: 2 m, class A, temperature range: -50...+200 C / 0.01 C 59966 ü ü Immersion thermocouple type K Dia. 1,5 x 250 mm, cable length: 2 m, class A, temperature range: -100 +500 C / 0.1 C 59961 ü ü ü Immersion thermocouple type K Dia. 3 x 150 mm, cable length: 2 m, class 2, temperature range: -50 +200 C / 0.1 C 59962 ü ü ü Insertion thermocouple type K Dia. 3 x 150 mm, cable length: 2 m, class 2, temperature range: -50 +200 C / 0.1 C 59963 ü ü ü Immersion resistance thermometer Pt100 Dia. 3 x 250 mm, cable length: 2 m, class 1/10B, temperature range: -90 +400 C / 0.001 C 57527 ü Immersion resistance thermometer Pt100 Dia. 3 x 400 mm, cable length: 2 m, class A, temperature range: -90 +400 C / 0.001 C 59265 ü A Immersion resistance thermometer Pt100 in glass Dia. 3/6 x 250 mm, cable length: 2 m, class A, temperature range: -90 +400 C / 0.001 C 59270 ü Surface sensor type K Dia. 15 x 170 mm, with thin-line thermocouple, cable length: 1,5 m, temperature range: -50 +400 C / 0.1 C 64106 ü ü ü Humidity sensor, capacitive Dia. 12 x 160 mm, cable length: 1,5 m, measuring ranges: 5...98 %r.h. / -20...+80 C 59644 ü ü ü Humidity/atmospheric pressure sensor, digital Dia. 9 x 65 mm, cable length: 2 m, measuring ranges: 5 98 %r.h. / -20...60 C / 700 1100 mbar, non-condensing 63953 ü ü ü

Sensors for PHYSICS digital measuring devices Technical data Ref. For PHYSICS device type PHYSICS sensors No. 51 100 300 1000 Humidity psychrometer, digital Case/box L 175 x W 50 x H 75 mm, for long-term and high-temperature mesurements, 59937 ü ü ü cable length: 5 m, meas. range: 10...100 %r.h. / 0...90 C / 700 1100 mbar, non-condensing Humidity psychrometer Hand-held device, dia. 50 x 245 mm, weight: approx. 300 g, cable length: 1.5 m, measuring ranges: 10...100 %r.h. / 0...60 C, non-condensing CO 2 /atmospheric pressure sensor, digital Dia. 18 x 250 mm, cable length: 1.5 m, measuring ranges: 0...10.000 ppm, -40...60 C, 700...1100 mbar, non-condensing 59638 ü ü ü 64143 ü ü ü Room climate sensor/globe thermometer Dia. approx. 150 mm, Wet Bulb Globe Temperature measuring (WBGT), cable length: 3 m, meas. range: -50...200 C 59639 ü ü Sensor for barometric pressure Hose connector: dia. 5 mm, L 90 x W 20 x H 7.6 mm, meas. range: 700...1050 mbar (0...1050 mbar) Sensor for barometric pressure, digital owithout connector, L 90 x W 20 x H 7.6 mm, meas. range: 700...1100 mbar (300...1100 mbar) 59645 ü ü ü 64063 ü ü ü Infrared temperature sensor with grip Dia. 45 x 250 mm, cable length: 1 m, measuring range: -20...350 C 59128 ü ü Redox electrode for manual measurements and pressure-free operation, Dia. 12 x 125 mm, operating range: 0 60 C, conductivity: >150 µs/cm, cable length: 1.2 m, platinum electrode ph electrode for manual measurements and pressure-free operation, Dia. 12 x 125 mm, measuring range: 1 12, operating range: 0 60 C, conductivity: >150 µs/cm, cable length: 1.2 m 64103 + 63864 64104 + 64105 ü ü ü ü Additional order-no.:.../03 with works certificate (for the unit temperature),.../04 with DAkkS certificate (for the unit temperature)