AG3000 SERIES FLANGED MAGMETER

Similar documents
AG3000 SERIES FLANGED MAGMETER

imag 4700 Series FLANGED MAGMETER

imag 4700 Series FLANGED MAGMETER

imag-series Flanged Magmeter

FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated

FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated

MAG. ECO FLO imag Series NSF FEATURES

imag 4700 Municipal/Industrial Magmeter Instructions PROUDLY MADE IN THE USA

Modbus. Interface. Description ISO 9001:2008

imag ISO 9001:2008 Municipal/Industrial Magmeter Instructions NSF Flow Meters & Controls ECO FLOMAG imag Series 9 001:2008 ISO CERTIFIED COMPANY

MAG. imag ISO. ECO FLO imag Series. Municipal/Industrial Magmeter Instructions NSF. Flow Meters & Controls ISO CERTIFIED COMPANY. o vi n g P a.

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06...

F-1000 DIGITAL PADDLEWHEEL FLOWMETER

Series DMHF Heat Meter

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/221

Flow Meters. Model B Flow Monitor. Model B2800. Flow Monitor

Flow Meters. Model B Flow Monitor. Model B2800. Flow Monitor

Clamp-On Ultrasonic Flow- and Energy Meter For Liquids

Ultrasonic Heat Flow Meters

Model Sono-Trak General Specification

Portable Dual Frequency Doppler Flowmeter

SENSOR MUT2200EL. Electromagnetic flowmeter. The electromagnetic flowmeter for all applications DS100-1-USA

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

CONVERTER MC608 A/B/R/P/I. The Hybrid electronic converter for all applications DS300-1-USA

UTM10 Series Ultrasonic Transit-time Flowmeters

INSTALLATION, OPERATION AND MAINTENANCE MANUAL IDS-676 DL

CONVERTER MC406. Electromagnetic flowmeter. The battery powered electronic converter DS400-1-USA

DREXELBROOK. Datasheet Universal IV In-Line Water Cut Meter. with Spool Piece Mounting USE THE BEST APPLICATIONS. Eliminate Routine Maintenance

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Signet 2552 Metal Magmeter Flow Sensors

Flow Measurement SITRANS F US Clamp-on

Clamp-On Transit Time Ultrasonic Flow Meters

Series TFXD FIXED LOCATION TRANSIT TIME FLOW METER FEATURES

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

IFB NO. ASPA A.WATER Purchase and Delivery of Variable Frequency Drives (VFDs) and Mag Meters. TECHNICAL SPECIFICATIONS FOR VFDs AND MAG METERS

The Model 464-BC Monitor controls and stores flow data from Marsh- McBirney Flo-Dar sensors. A portable computer and Flo-Ware software is used to

Flow Measurement SITRANS F M

Series TFXP PORTABLE TRANSIT TIME FLOW METER FEATURES

Local Model. Remote Model. FPD1000D-BAT Battery Powered Display Local and Remote Models

Family of Water Cut Analyzers

EQUITY SERVICES & SOLUTIONS CO.,LTD. cono Flow

Sensor Wafer MUT 1000 EL DS120-1-ENG

FT400-Series RATE/TOTAL INDICATOR INSTRUCTIONS FT415 FT :2008 ISO CERTIFIED COMPANY FT400-SERIES RATE TOTAL/INDICATOR INSTRUCTIONS

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

Universal IV Water Cut Meter

SITRANS F M MAG 8000 SITRANS F. Answers for industry. Precise metering with battery powered water meters.

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation

DFW Ultrasonic Water Meters

Flow Measurement SITRANS F M

NFC110. Flow Computer For Low Pulses FEATURES

Technical specification FLUXUS F501. Ultrasonic measurement of water flow

Product Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

SITRANS F flowmeters SITRANS F US

DCT7088 Portable Digital Correlation Transit Time Flowmeter

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

Spectrum 175D. meter performance with no maintenance.

B.M LIMENA (PD)

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

MULTI PARAMETER WATER QUALITY SENSORS

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

SONICMAX UL3400C. 3-BEAM Compact Ultrasonic Flowmeter OUTLINE FEATURES STANDARD SPECIFICATIONS

Simplified information where and how you want it.

Zelio Count - Counters RC87610

Flow Measurement SITRANS F US Clamp-on

... f l o w measurement & control...

Pile Driver Weld Immune Sensors

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

UW Purchase Specification Section Central Cooling Water Meter Page 1 of 6

RHE27. Rack/Panel Mount Multifunction Coriolis Flow Transmitter

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE. Series 380 Impeller Btu System

OPERATING INSTRUCTIONS

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F

DMT345 and DMT346 Dewpoint Transmitters

SCADAPack Modbus multivariable transmitter

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Accessories for liquid level transmitters Catalog

Inductive Cylinder Position Sensors

Continuous level measuring system NB 3000 Selection list

Series TFXB Ultra. Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel

Technical specification FLUXUS F501IP. Non-invasive ultrasonic flow measurement on buried pipes. Features. Applications

Telephony Multi-Taps. 9000T-TP Series

MMT330 Series Moisture and Temperature Transmitters for Oil

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUG1010 (Gas) 4/336 Siemens FI Overview

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

Spectrum 130D. Warranty 5 Yr. Materials & Workmanship 5 Yr. OER Register Standards AWWA C NSF-61/372

NF770 Temperature Compensation Liquid Flow Computer

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter

Conductivity Transmitters

DMTFP Portable Ultrasonic Flow Meters

Ultra Sonic Flowmeter DATASHEET

T E M P O S O N I C S I I I INSTALLATION

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 NPT

TRICOR Series TCM Coriolis Mass Flow Meters

The Emflux Flow Meter Family

Flow Measurement SITRANS F US Inline

MULTI PARAMETER WATER QUALITY SENSORS PENTAIR ENVIRONMENTAL SYSTEMS

Compact Electric Actuators AC and DC Voltages 18 Nm/160 inch lbs

Transcription:

RIGHT METER FOR Irrigation Chemigation Agricultural automation Well usage monitoring Dairy lagoons p r (Remote Display) Features Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal IP68 rated Telemetry ready for wireless meter reading Contact Your Supplier The Series is a spool-type electromagnetic flowmeter for use in irrigation applications in 4 to 12 pipe (for 3 version, see AG2000-300 specification). With no moving parts, these meters provide unobstructed flow and are resistant to wear from debris found in ground or surface water. Little maintenance is required because there are no bearings to wear out or propellers to stop turning. Minimal straight pipe requirements allow meters to be used in piping configurations where there is little space between the meter and an elbow. The standard is battery powered with an available pulse output. Both rate and total indication are displayed. Bidirectional flow reading is standard with totals available in forward, reverse, net flow, batch forward flow, and batch reverse flow. Batch totals can be reset. Built-in data logging is available as an option for secure flow logging. The is also available in either AC or DC powered versions, with battery backup. Pulse output is standard on all models and 4-20mA passive current loop is standard on the p. In addition, 4-20mA loop, HART protocol, high speed digital, and Modbus protocol outputs are optional on the externally powered units, depending on model. A power/output cable allows outputs for use with a variety of Seametrics and other displays and controls for remote reading and telemetry applications. Rate and total units, pulse scaling, and various other settings are set via the front panel touch-key pad by the user. The remote display model (r) provides remote access for controlling the meter and viewing readings. The Series is CE certified (pending) and IP68 for burial, or applications where the meter may be under water for prolonged periods of time. All meters are secured with a seal to protect unauthorized access. The seal can be broken by an authorized agent, to change units of measure, pulse rate, replace the battery pack, or field install a power/output cable. The cable is field installed where external power is available and/or an output is needed. ISO 9001:2008 Certified Company PROUDLY MADE IN THE USA 253.872.0284 seametrics.com

Features Rate and total indicator with light sensor button controls User access lid Power and Output cable port access Equalization lug Santoprene/Polypropylene Liner Data logger port (right side, not shown) Powder-coated diecast aluminum electronics housing 316SS electrodes (Inside) Welded steel epoxycoated flow tube Flanges,150 lb. ANSI pattern Protective faceplate cover and lanyard Powder-coated diecast aluminum electronics housing Power and Output cable port access Equalization lug User access lid (on back) Data logger port (right side, not shown) Rate and total indicator with light sensor button controls Flanges, 150 lb. ANSI pattern 316SS electrodes (Inside) Santoprene/Polypropylene Liner Welded steel epoxycoated flow tube p r (Remote indicator) Protective faceplate cover and lanyard 253.872.0284 Page 2 seametrics.com

Features Built-in Data Logger (Optional) Bidirectional Flow Reading (Standard) Pulse Scaled Output (Standard) 4-20mA Output (Optional*) HART Protocol Output (Optional*) Modbus Protocol Output (Optional*) High Speed Digital Output (Optional*) Battery Power ( battery model only) External DC Power (Optional*) Integrated AC Power Supply (Optional*) Remote Display (r) Quickly and easily change Total Volume Units, Flow Rate Units, Pulse Output Scaling, and many other settings using the two light sensor button controls on the display panel. * Some optional items only available on some configurations. See last page for further details. 2X Pipe Diameter 1X Pipe Diameter FLOW Minimal straight pipe requirements to ease installation in tight quarters. No moving parts to break or foul! 253.872.0284 Page 3 seametrics.com

Specifications Pipe Sizes Flanges Pressure Modbus is a registered trademark of Schneider Electric. *Specifications subject to change. Please consult our website for the most current data (www.seametrics.com). 1 If forward and reverse flow data needs to be sent to another device, either the Digital or Modbus output is required. 2 Rate Time Unit is available in Day only. 4, 6, 8, 10, 12 (For 3 version, see AG2000-300.) 150 lb. ANSI Pattern 150 psi (10.3 bar) line pressure Temperature Operating 10 to 130 F (-12 to 54 C) Accuracy Low Flow Cutoff Storage -40 to 158 F (-40 to 70 C) Body (4-12 ) Liner (4-12 ) Electronics Housing Electrodes ± 0.75% of reading on p and r (± 1.0% ) ± 0.025% of full-scale flow from low flow cutoff to maximum flow rate of 10 m/sec 0.5% of maximum flow rate Welded steel, epoxy-coated Santoprene flange/polypropylene liner body Powder-coated diecast aluminum 316 stainless steel Display Type 128x64 dot-matrix LCD Digits 5 Digit Rate 8 Digit Total Units Please Note: All meters are factory set for gallons per minute (GPM) rate and gallons total. If other units are required, they can be set in the field. Bidirectional 1 Rate Volume Units Gallons Liters Barrels(42 gal) Cubic Feet Cubic Meters Million Gallons 2 Mega Liters Imperial Gallons Million Imperial Gallons 2 Rate Time Units Second Minute Hour Day Total Volume Units Gallons Gallons x 10 Gallons x 100 Gallons x 1000 Million Gallons Liters Kilo Liters Mega Liters Forward Total, Reverse Total, Net Total, Batch Forward Total, Batch Reverse Total (Batch totals can be reset) Power DC Power 9-36 Vdc @ 250 ma max, 30 ma average Scaled Pulse Output Battery Backup AC Power (r and p only) Battery ( only) Signal Pulse Rates DC powered units: Two lithium 3.6V D batteries, replaceable. AC powered units: One 9V alkaline battery, replaceable. 85-264Vac, 50/60Hz, 0.12A Two lithium 3.6V D batteries, replaceable. Current sinking pulse, isolated, 36 Vdc at 10 ma max Barrels (42 gal) Cubic Meters Cubic Meters x 1000 Cubic Feet Cubic Feet x 1000 Second Foot Day Million Cubic Feet Acre Feet Acre Inches Imperial Gallons Imperial Gallons x 1000 Million Imperial Gallons Fluid Ounces User-scalable from 0.1 to 99,999.9 volume units/pulse. Pulse width is one-half of pulse period with minimum pulse width of 2.5 ms, 200 pulses/sec max, 150 pulses/sec max with battery option Options 4-20mA Current Loop Isolated, passive, 24Vdc, 650 Ω maximum current loop HART/4-20mA High Speed Digital Output ( and p only) HART protocol over 4-20mA line Isolated, open collector, 24 Vdc Serial Communications Isolated, asynchronous serial RS485 (Reconfigurable for RS232 or 3.3V CMOS), Modbus RTU protocol (factory selectable) Cable Power/Output Cable 20ft (6m) standard length polyurethane jacketed cable for power and outputs (lengths up to 200 available). Conductivity Empty Pipe Detection Remote Display Cable (r) 20ft (6m) standard length polyurethane jacketed cable for connection between meter and remote display (lengths up to 200 available). >20 microsiemens/cm Regulatory (EN 61326) Environmental Hardware/software, conductivity-based IP68 (10ft (3m) depth, continuously) 253.872.0284 Page 4 seametrics.com

Accuracy 5 4 Accuracy (%) 3 2 1 r & p 0 0 2 4 6 8 10 0 0 5 10 15 15 20 20 25 25 30 30 33 (m/s) (ft/s) Flow Velocity Flow Rate (4-12 ) Pipe Size (Inches in diameter) 4 6 8 10 12 Max Flow Rate (Gallons/Minute) 1285 2891 5140 8031 11565 Cut-off (min) Flow Rate (Gallons/Minute) 6.43 14.46 25.70 40.15 57.82 Max Flow Rate (Liters/Second) 81 182 324 507 730 Cut-off (min) Flow Rate (Liters/Second) 0.41 0.91 1.62 2.54 3.65 Max Flow Velocity (Meters/Second) 10 10 10 10 10 253.872.0284 Page 5 seametrics.com

Dimensions - H T ID L Meter Size L H T ID Shipping Weight inch mm inch mm inch mm inch mm lbs Kg 4 10.24 260 8.3 211.62 15.7 3.12 79 27 12 6 12.27 312 9.1 231.69 17.5 5.05 128 42 19 8 14.24 362 10.1 257.69 17.5 6.44 164 64 29 10 18.18 462 11.2 284.69 17.5 8.61 219 123 56 12 19.68 500 12.2 310.81 20.6 10.55 268 165 75 Flanges Standard ANSI 150 lb. drilling Cable 1 lb. 253.872.0284 Page 6 seametrics.com

Dimensions - r and p r (remote display) 6.840 (173.7 mm) 4.000 (101.6 mm) 3.500 (88.9 mm) 4.150 (105.4 mm) 5.200 (132.1 mm) Ø 5.285 (134.2 mm) 4.375 (111.1 mm) Ø 0.200 (5.08 mm) p and r (remote meter) H T ID Meter Size L L H T ID Shipping Weight p r inch mm inch mm inch mm inch mm lbs Kg lbs Kg 4 10.24 260 8.6 218.62 15.7 3.12 79 28 13 31 14 6 12.27 312 9.4 239.69 17.5 5.05 128 43 19.5 46 21 8 14.24 362 10.4 264.69 17.5 6.44 164 65 29.5 68 31 10 18.18 462 11.5 292.69 17.5 8.61 219 124 56.5 127 58 12 19.68 500 12.5 317.81 20.6 10.55 268 166 75.5 169 77 Flanges Standard ANSI 150 lb. drilling Cable 1 lb. 253.872.0284 Page 7 seametrics.com

How to Order Worksheet p r 1 2 3 4 5 6 7 2 Style: F1 = 150 lb ANSI Pattern 3 Power: D1 = DC 60Hz, D2 = DC 50Hz 4 Outputs: X = No optional output A1 = AC 60Hz, A2 = AC 50Hz L = 4-20mA BX = Battery H = HART/4-20mA S G = = Modbus Digital (Integrated Display) Size 1 Style Power -0400 4-0600 6-0800 8 1 2 3 4 5 6-1000 10-1200 12 -F1 -D1 -D2 -BX Optional Output (The comes standard with one pulse output) -X (requires single cable for DC power & output) -L (requires single cable for DC power & output) -H (requires single cable for DC power & output) -S (requires dual cable for DC power & output) -G (requires dual cable for DC power & output) -X (requires single cable for pulse output) Options -XX None -01 Data Logger DC Power/Output Cable - 6 conductor (Must select one) -0000 No Cable (customer will supply) Single Dual -006S -006D 6 meter (20 ft) -015S -015D 15 meter (50 ft) -030S -030D 30 meter (100 ft) -045S -045D 45 meter (150 ft) -060S -060D 60 meter (200 ft) p (Integrated Display) Size 1 Style Power 2 (The p comes standard with 4-20mA and one pulse output) Optional Output -0400 4-0600 6-0800 8 1 2 3 4 5 6-1000 10-1200 12 -F1 -D1 -D2 -A1 -A2 -X (requires single cable for DC power & output) -H (requires single cable for DC power & output) -S (requires dual cable for DC power & output) -G (requires dual cable for DC power & output) -X (requires single cable for output) -H (requires single cable for output) -S (requires single cable for output) -G (requires single cable for output) Options -XX None -01 Data Logger DC Power/Output Cable - 8 conductor (Must select one) -0000 No Cable (customer will supply) Single Dual -006S -006D 6 meter (20 ft) -015S -015D 15 meter (50 ft) -030S -030D 30 meter (100 ft) -045S -045D 45 meter (150 ft) -060S -060D 60 meter (200 ft) r (Remote Display) 1 2 3 4 5 6 7 Size 1 Style Power 2 (The r comes standard with one pulse output) Optional Output -0400 4-0600 6-0800 8-1000 10-1200 12 -F1 -D1 -D2 -A1 -A2 -X (requires single cable for DC power and output) -L (requires single cable for DC power and output) -H (requires single cable for DC power and output) -S (requires dual cable for DC power and output) -X (requires single cable for output) -L (requires single cable for output) -H (requires single cable for output) -S (requires single cable for output) Options -XX None -01 Data Logger DC Power/Output Cable - 6 conductor (Must select one) -0000 No Cable (customer will supply) Modbus is a registered trademark of Schneider Electric. Viton is a registered trademark of DuPont Corporation. Note: All meters are factory set for gallons per minute (GPM) rate and gallons total. If other units are required, they can be programmed in the field. 1 For 3 version see AG2000-300. 2 AC meters come with a 1.8 meter (6 ft) AC power cable. Single Dual -006S -006D 6 meter (20 ft) -015S -015D 15 meter (50 ft) -030S -030D 30 meter (100 ft) -045S -045D 45 meter (150 ft) -060S -060D 60 meter (200 ft) Remote Display Cable - 6 conductor (Must select one) -006 6 meter (20 ft) -015 15 meter (50 ft) -030 30 meter (100 ft) -045 45 meter (150 ft) -060 60 meter (200 ft) Seametrics 19026 72nd Avenue South Kent, Washington 98032 USA (P) 253.872.0284 (F) 253.872.0285 1.800.975.8153 seametrics.com LT-14258r1.4 20170105 1/5/17