Safety Products Introduction LS-Titan Safety Interlock Switches. Technical Reference... 2

Similar documents
Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

CS8 Industrial Control Relays

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Limit Switches Overview

Electronic timer CT-ERD.12

Disconnect Switches. Safe Switching and Disconnecting

Electronic timer CT-ARS.11

Movements safely under control Safety/position switches and proximity switches

1.4. Pushbuttons and Indicating Lights. Product Overview

Electronic timer CT-AHD.22

SIRIUS 3SE5, 3SE2 Mechanical Safety Switches Mechanical Safety

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Motor protection relays

Online data sheet. i15-mm0123 Lock i15 Lock SAFETY LOCKING DEVICES

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Electronic timer CT-ERS.21

Datasheet - SRB 301LC/B-24V

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Ordering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R

Compact Coded Magnetic Safety Interlock Switch and Control Units

XB7NA4234 PB - Spring Rtn, red - 1NC -White "STOP"

Reliable and Precise Command and Signalling

Datasheet SRB301ST 24V (V.2)

Non-Contact Safety System CES-AZ

Safety Systems Safety Integrated

Online data sheet. i110-e0453 i110 Lock SAFETY LOCKING DEVICES

Magnetically Actuated Safety Interlock Switches

Reliable and Precise Command and Signalling

SIGUARD Safety Systems Safety Integrated

Tongue Switches Trojan 5 & 6

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

Safety switches with separate actuator

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

Machine Safety. Products

Online data sheet. i200-m0323 Lock i200 Lock SAFETY LOCKING DEVICES

Datasheet - AZM 200 BZ ST-T-AS P

Contact form. Operating Force. SPDT 100g Unsealed Solder / 187 Quick Connect. SPDT 200g Unsealed Solder / 187 Quick Connect

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C

SERIES AZ15/16. Tamper-Resistant Movable Machine Guard Safety Interlock Switch. Features & Benefits. Description. Operation. Typical Applications

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Online data sheet. i200-m0413 Lock i200 Lock SAFETY LOCKING DEVICES

Versatile Safety Interlock Switch with Guard Door Locking

XB7NS8442 Emergency stop Ø 22 - red - mushroom head Ø 40 mm - turn to release - 1 NC

1492-SP Supplementary Protectors

Datasheet AZM 161 Z ST1 AS RA

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

GENERAL TECHNICAL DATA Specifications, Directives and Standards

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Safety relay emergency stop/protective door, 230VAC, 3 enabling paths

SL7CB100 Stacklight Led Flashing, Yellow, 120V, 70MM

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

Online data sheet. i10-e0454 Lock i10 Lock SAFETY LOCKING DEVICES

Safety relay emergency stop/protective door, 24V-230VDC/AC, 3 enabling paths

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

XB4BW73731B5 green flush/red projecting illuminated double-headed pushbutton Ø22 1NO+1NC 24V

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Safety relay emergency stop/protective door, 24VDC/AC, 3 enabling paths

Magnetically Actuated Safety Interlock Switches

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Safety switches for hinged doors

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs Safety Contacts Direct Opening Action. Operating Radius, Min

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

Microswitches MS Series

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

OsiSwitch Limit Switches Innovation through modularity

Position Switches Series 8070

TeSys IEC Contactors and Overload Relays

Safety switches with manual mechanical delay and separate actuator

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever

UL 489 DIN Rail Miniature Circuit Breakers

Online data sheet. i10-m0233 Lock i10 Lock SAFETY LOCKING DEVICES

Contact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect

52 x 72 x 30 (2.05 x 2.83 x 1.18) N/C + N/O; N/C + N/C N/C + N/O N/C + N/O; N/C + N/C

Legacy Sensor Products

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

Datasheet - SRB 402EM-24V

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

UL 489 DIN Rail Miniature Circuit Breakers

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

Datasheet - AZM300Z-ST-1P2P-A

XCKN2110P20 limit switch XCKN - metal end plunger - 1NC +1NO - snap - M20

Sensor Accessories Retroreflectors and Retroreflective Tape Sensor Mounting Brackets Sensor Accessories. 52.

Thermal-Magnetic Circuit Breaker 4220-T...

Transponder-coded. with guard locking

Datasheet - AZM 200SK-T-1P2PW

SAFETY LOCKING DEVICES

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Contact protection relay

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

ZB5FG09 flush mounted selector switch head key pos stay put

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Thermistor motor protection relay CM-MSS.21

Transcription:

Key Interlock Switch Door-Flap Switch Door-Hinge Switch.0 Introduction Technical Reference............................................ 2.1 Learn Online Product Description............................................. 3 Features...................................................... 3 Standards and Certifications...................................... 3 Product Identification............................................ 4 Product Selection.............................................. 5 Technical Data and Specifications.................................. 8 Mounting Instructions........................................... 9 Dimensions................................................... 10 For Customer Service in the U.S. call 1-877-ETN CARE (386-2273), in Canada call 1-800-268-3578. For Application Assistance in the U.S. and Canada call 1-800-426-9184. Volume 8 Sensing Solutions CA08100010E February 2011 www.eaton.com 1

.0 Safety Products Introduction Technical Reference LS-Titan Safety Interlock Switches Often the need arises for a device to provide a signal indicating that a door has been closed or that a machine guard is in place before a machine can be turned on or a sequence of operations can begin. While a standard limit switch would probably be able to do this function, the possibility exists that the unit could be false tripped or false actuated either accidently or deliberately, thereby posing a danger to the person operating the machine. In response to this problem, many switch manufacturers offer what is known as a key interlock switch. These switches look and operate similar to standard limit switches except for the operating heads. Instead of a rotary or plunger operating head, there is a key slot. Interlock Switch Key Key Slot Actuation of the interlock switch occurs only when the corresponding key is inserted into the key slot. The key is usually mounted on a door or machine guard in such a way that when the door or guard is closed, the key fits into the slot actuating the switch. The special design of the key makes the safety interlock switch extremely difficult to defeat. When inserted into the slot, the key performs three separate mechanical functions. In addition to being difficult to override, the safety interlock is also designed to fail to a safe mode. If, by chance, the contacts were to become welded together, removal of the key will physically tear the contacts apart, resulting in a safe condition. LS-Titan key interlock switches by Eaton s electrical sector are available in both NEMA and DIN style housings. NEMA style key interlock switches feature durable metal housings, which remove power to the machine when the guard is opened. DIN style key interlock switches feature a reduced size and economical plastic housings. They remove power to the machine when the guard is opened. 2 Volume 8 Sensing Solutions CA08100010E February 2011 www.eaton.com

.1 Product Description Eaton s LS-Titan safety interlock switches have been specifically designed for monitoring the position of protective guards, such as doors, flaps, hoods and grilles. All switches in this family are safety-rated, include positively opening NC contacts, and cannot be defeated using simple tools, such as pliers, screwdrivers and nails. The LS-Titan safety interlock family is comprised of three types of safety switches: key interlock, door-flap and doorhinge switches. Key interlock switches are a two-piece design, made up of the switch and key (actuator). The key portion of the switch is affixed to a movable door, cover or other such guard. The switch itself is mounted to a rigid portion of the machine. When the guard is opened, the key is removed from the switch, thereby positively breaking the NC contacts. This interrupts the control circuit, stopping machine operation. For the most current information on this product, visit our web site: www.eaton.com The door-flap and door-hinge switches are one-piece designs, suitable for when a key cannot be mounted in the application. When an attempt is made to open a protected door hinge or flap during operation, these switches disconnect the power supply to the machine or installation. Both switches feature fourway adjustable heads. All LS-Titan safety interlock switches are approved to protect personnel and processes. Contents Description Page Product Identification........................... 4 Product Selection LS-Titan Miniature DIN Safety Interlock Switches......................... 5 LS-Titan Full-Size DIN Safety Interlock Switches......................... 6 LS-Titan Solenoid Safety Interlock Switches......................... 6 LS-Titan Solenoid Safety Interlock Keys............................. 7 Technical Data and Specifications................. 8 Mounting Instructions.......................... 9 Dimensions.................................. 10 Features Broad family of safety interlock switches in industry-standard enclosure sizes: miniature DIN; full-size DIN; and larger, solenoid key interlocks providing the highest degree of personnel and process protection Large selection of actuators (keys), including those for sliding doors, swing doors and doors that do not close precisely Miniature DIN models have a five-way adjustable head, while full-size DIN models have four-way adjustable heads Fully safety-rated as interlocking devices per EN 1088, with safety function by positive opening contacts per IEC/EN 60947-5-1 Door-flap and door-hinge safety switches provide a unique solution when actuators (keys) cannot be used IP65 degree of protection Standards and Certifications UL listed CSA approved CCC Positive opening NC contacts per EN 60947-5-1 Safety Do not use as a mechanical stop/shipping brace. Any change to an original Eaton safety position switch is not permitted and automatically leads to the loss of all approvals. Switch must never be used as a mechanical stop. For Customer Service in the U.S. call 1-877-ETN CARE (386-2273), in Canada call 1-800-268-3578. For Application Assistance in the U.S. and Canada call 1-800-426-9184. Volume 8 Sensing Solutions CA08100010E February 2011 www.eaton.com 3

.1 Safety Products Product Identification Solenoid Safety Interlock Switches (LS-...ZBZ) Basic device (see Page 6) Spring or magnet-powered interlock For increased personnel and process protection Tamper-proof Multiple coded actuators Contacts: 1NO-1NC or 2NC Miniature DIN Safety Interlock Switch (LS-...ZB) Complete device (see Page 5) For personnel protection Contacts: 1NC, 1NO-1NO or 2NC Five directions of operation possible Actuator (see Page 5) Included with switch Multiple coding protection against tampering Flat flexible actuator (see Page 7) For doors that do not close precisely Angled flexible actuator (see Page 7) For doors that do not close precisely Flat actuator (see Page 7) For sliding doors Door Flap Safety Switch (LSR-...TKG) Note Complete device (see Page 5) For personnel protection Contacts: 1NO-1NC or 2NC For swing doors with fixed connection to the door/hinge pin Angled actuator (see Page 7) For swing doors Flat compensating actuator (see Page 7) For increased tolerance compensation in the direction of door closure Door Hinge Safety Switch (LSR-...TS) Note Complete device (see Page 5) For personnel protection Contacts: 1NO-1NC or 2NC For swing doors with fixed connection to the door/hinge pin Angled compensating actuator (see Page 7) For increased tolerance compensation in the direction of door closure Full-Size DIN Safety Interlock Switch (LS4-...ZB) Complete device (see Page 6) Narrow enclosure version For personnel protection Contacts: 1NO, 1NO-1NC Actuator Included with switch, not orderable as a separate item Multiple coding For horizontal or vertical operation 4 Volume 8 Sensing Solutions CA08100010E February 2011 www.eaton.com

.1 Product Selection LS-Titan Miniature DIN Safety Interlock Switches Key Interlock Switch Door-Flap Switch Door-Hinge Switch Replacement Safety Interlock Key Key Interlock Switch LS- ZB Contacts Contact Sequence Contact Travel Connection Door-Flap Switch LSR- TKG Door-Hinge Switch LSR- TS Replacement Safety Interlock Key Description Note For dimensions, see Page 10. Catalog Number (Includes Key) 2NC with 11 Screw terminal LS-S02-ZB 1NO and 1NC with Screw terminal LS-S11-ZB Snap action contacts Screw terminal LS-S11S-ZB Contacts Contact Sequence Contact Travel Connection Catalog Number (Includes Key) 2NC with 11 0 Screw terminal LSR-S02-1-I-TKG 5 5 22 12 22 11 12 90 90 Zw = 10 1NO and 1NC with Screw terminal Contacts Contact Sequence Contact Travel Connection LSR-S11-1-I-TKG Catalog Number (Includes Key) 2NC with 11 0 Screw terminal LSR-S02-1-I-TS 5 5 22 12 22 11 12 90 90 Zw = 10 1NO and 1NC with Replacement key for miniature DIN key interlock switches (only models LS- ZB). 12 13 22 13 13 0 5 5 22 13 14 90 17 17 90 Zw = 10 0 5 5 22 13 14 90 17 17 90 Zw = 10 Catalog Number LS-XB-ZB Screw terminal LSR-S11-1-I-TS Volume 8 Sensing Solutions CA08100010E February 2011 www.eaton.com 5

.1 Safety Products LS-Titan Full-Size DIN Safety Interlock Switches Key Interlock Switch Full-Size DIN LS4- ZB LS-Titan Solenoid Safety Interlock Switches Switch Body without Key Contacts Contact Sequence Contact Travel Connection 1NO and 1NC with Switch Body without Key LS- ZBZ For dimensions, see Page 10. For mounting instructions, see Page 9. Key ordered separately, see Page 7. Catalog Number (Includes Key) Screw terminal LS4-S11-1-I-ZB Operation Operating Voltage Contacts Contact Sequence Power to unlock (mechanical bypass present) Power to lock (mechanical bypass present) 13 24 Vdc 1NO and 1NC with 2NC with 120 Vac (50/60 Hz) 1NO and 1NC with 2NC with 24 Vdc 1NO and 1NC with 2NC with 120 Vac (50/60 Hz) 1NO and 1NC with 2NC with 13 A1 A2 11 A1 A2 12 22 13 A1 A2 11 A1 A2 12 22 13 A1 A2 11 A1 A2 12 22 13 A1 A2 11 A1 A2 12 22 Catalog Number (Key not Included) LS-S11-24DFT-ZBZ-X LS-S02-24DFT-ZBZ-X LS-S11-120AFT-ZBZ-X LS-S02-120AFT-ZBZ-X LS-S11-24DMT-ZBZ-X LS-S02-24DMT-ZBZ-X LS-S11-120AMT-ZBZ-X LS-S02-120AMT-ZBZ-X 6 Volume 8 Sensing Solutions CA08100010E February 2011 www.eaton.com

.1 LS-Titan Solenoid Safety Interlock Keys LS-XG-ZBZ LS-X -ZBZ LS-XF-ZBZ LS-XFG-ZBZ LS-XNG-ZBZ LS-XNW-ZBZ Keys Only LS- ZBZ Description Application Catalog Number Flat actuator For sliding doors LS-XG-ZBZ Angled actuator, short For swing doors starting at 250 mm in width LS-XW-ZBZ Angled actuator, long For swing doors starting at 250 mm in width LS-XWA-ZBZ Angled, flexible actuator For doors that do not close precisely LS-XF-ZBZ Even, flexible coasting actuator For doors that do not close precisely LS-XFG-ZBZ Flat, compensating actuator Angled, compensating actuator Switch body ordered separately, see Page 6. For mounting instructions, see Page 9. Increased tolerance in closing direction for inaccurately closing doors Increased tolerance in closing direction for inaccurately closing doors LS-XNG-ZBZ LS-XNW-ZBZ Volume 8 Sensing Solutions CA08100010E February 2011 www.eaton.com 7

.1 Safety Products Technical Data and Specifications Units LS-...ZBZ LS-...ZB LS4...ZB General Standards IEC/EN 60947 IEC/EN 60947 IEC/EN 60947 Climatic proofing Ambient temperature C 25 +0 25 +70 25 +70 Mounting position As required As required As required Protection type IP65 IP65 IP65 Terminal capacities Solid mm 2 1 x (0.75 2.5)/2 x (0.75 1.5) 1 x (0.75 2.5)/2 x (0.75 1.5) 1 x (0.75 2.5)/2 x (0.75 1.5) Flexible with ferrule mm 2 1 x (0.75 2.5)/2 x (0.75 1.5) 1 x (0.75 2.5)/2 x (0.75 1.5) 1 x (0.75 2.5)/2 x (0.75 1.5) Contacts/Switching Capacity Rated impulse withstand voltage U imp Vac 4000 6000 6000 Rated insulation voltage U i V 400 500 500 Overvoltage category/pollution degree III/3 III/3 III/3 Burden Current AC 15 24V I e A 6 10 10 230V/240V I e A 6 6 6 400V/415V I e A 4 4 4 DC-13 24V I e A 3 3 3 110V I e A 0.8 0.8 0.8 220V I e A 0.3 0.3 0.3 Supply frequency Hz max. 400 max. 400 max. 400 Short-circuit rating to IEC/EN 60947-5-1 Max. fuse A gg/gl 6 6 6 Repetition accuracy mm ± 0.02 ± 0.02 ± 0.02 Mechanical Variables Lifespan Standard-action contact Operations x 10 6 1 10 10 Snap-action contact Operations x 10 6 Mechanical shock resistance (half-sinusoidal shock, 20 ms) Standard-action contact g 10 25 5 Snap-action contact g Operating frequency Operations/h 800 1800 1800 Actuation Mechanical Actuating force at beginning/end of stroke ZB/ZBZ (push in/pull out) N 25/15 10/5 15/20 Mechanical holding force according to GS-ET-19 (04/2004) XG, XW N 1500 N/A N/A XFF, XNG, XWA N 1300 N/A N/A XF N 750 N/A N/A XNW N 500 N/A N/A Electromechanical For magnet Power consumption at 120 Vac VA 8 N/A N/A at 230 Vac VA 11 N/A N/A at 24 Vdc W 8 N/A N/A Pickup and dropout values x U s 0.85 1.1 N/A N/A Magnet duty factor % ED 100 N/A N/A Note Damp heat, constant, to IEC 60068-2-78; damp heat, cyclical, to IEC 60068-2-30. 8 Volume 8 Sensing Solutions CA08100010E February 2011 www.eaton.com

.1 Mounting Instructions LS- ZB, TKG, TS LS4- ZB LS- ZBZ Actuator can be repositioned for horizontal or vertical installation. The operating heads can be rotated manually in 90 steps to suit the specified direction of operation. Actuator can be repositioned for horizontal or vertical installation. The operating heads can be rotated manually in 90 steps to suit the specified direction of operation. The operating head can be rotated manually in 90 steps to suit the specified level of actuation. In the event of a loss of voltage, (e.g., during commissioning), the springpowered LS- -. FT-ZBZ can be released with a screwdriver. The auxiliary release mechanism must be sealed. Volume 8 Sensing Solutions CA08100010E February 2011 www.eaton.com 9

.1 Safety Products Dimensions Approximate Dimensions in Inches (mm) Safety Position Switches LS -ZB MA=0.6 Nm 4 x 90 0.22 (5.5) 1. (30.8) 0.06 (1.5) 1.06 (27.0) 2.17 (55.0) 1.42 (36.0) 0.73 (18.5) 0.02 (0.5) 0.22 (5.5) 0.14 (3.5) MA=1.4 Nm 0.87 (22.1) 1. (30.8) 0.24 (6.0) +0.5 +0.5 R 250 0.004 0.12 (0.1 3.0) R 250 +1.0 +1.0 6.81 ( 173.0) 6.73 (171.0) 5.37 (136.3) M 20x1.5 1.26 (32.0) M5 x 1.38 (M5 x 35.0) LS-S...FT-ZBZ/_ 1.54 ( 39.0) 1.17 (29.6) 0.60 (15.2) 0.78 (19.8) Ø0.20 (Ø5.2) 0.39 (10.0) 2.36 ( 60.0) 1.49 (37.8) 0.59 (15.0) 0.71 (18.0) 1.26 (32.0) 0.60 (15.2) 0.63 (16.0) 0.17 0.28 (4.3 7.2) +0.5 +0.5 R 0 120 180 LS-XWA-ZBZ U = 0 V U = 0 V F Switch must never be used as a mechanical stop. The auxiliary release mechanism must be sealed for proper operation. Can be used as stop with the corresponding material selection and design. 10 Volume 8 Sensing Solutions CA08100010E February 2011 www.eaton.com

.1 Approximate Dimensions in Inches (mm) Actuators LS-XG-ZBZ 1.75 (44.4) 0.49 (12.5) M5 LS-XNW-ZBZ 1.26 (32.0) LS-XFG-ZBZ 0.24 (6.0) M5 1.61 (41.0) 1.54 (39.1) 1.38 (35.0) 1.54 (39.0) 0.89 (22.5) M5 M5 0.26 (6.5) M6 M6 0.23 (5.8) 2.42 (61.4) LS-XW-ZBZ 0.23 (5.8) 1.32 (33.5) 2.29 (58.2) 4.11 (104.5) 0.12 (3.0) M5 1.12 (28.5) 0.85 (.5) 0.30 (7.5) 1.38 (35.0) 0.39 (10.0) M5 0.29 (7.3) LS-XF-ZBZ 2.40 (61.0) 0.24 (6.0) 1.61 (41.0) 0.89 (22.5) LS-XNG-ZBZ 1.91 (48.4) LS-XWA-ZBZ M6 M6 2.64 (67.0) 0.74 (18.9) 1.10 (28.0) 0.28 (7.0) M5 M5 0.74 1.54 (18.8) (39.0) Ø0.16 (Ø4.1) 0.94 0. (24.0) (5.4) 0.26 (6.5) 1.00 (25.5) 0.47 (12.0) 2.13 (54.2) Distance to device head = 0.1 3.0 mm. Fixing only allowed with M5 fixing screw and washer according to DIN EN ISO 7093. Pin with a 4 mm pin after mounting. 0.30 (7.5) 2.93 (74.5) 2.17 (55.1) 0.71 (18.0) 1.57 (40.0) Volume 8 Sensing Solutions CA08100010E February 2011 www.eaton.com 11

.1 Safety Products Approximate Dimensions in Inches (mm) Safety Door Flap Switch LSR-.../TKG 1.04 (26.5) 110 0.63 (16.0) 1.97 (50.0) 2.83 (72.0) 0.14 (3.5) 0.06 0.30 (1.6) (7.5) 110 0.20 (5.1) 3.15 (80.0) 1.35 (34.2) Safety Hinge Switch LSR-.../TS 360 0.87 (22.0) 1.04 (26.5) 3.15 (80.0) M20 Ø0.31 (Ø8.0) Ø0.47 (Ø12.0) Ø0.12 (Ø3.0) 2.32 (59.0) 0.63 (16.0) 2.24 (56.9) 0.49 (12.5) 32 0.43 (11.0) 135 M20 0.87 (22.0) Safety Position Switches LS...-ZB 0.87 (22.0) 0. (5.3) 0.16 (4.1) 0.63 (16.0) 0.60 (15.3) M20 x 1.5 1.26 (32.0) 3.27 (83.0) 0.02 0.12 (0.5 3.0) 1.61 (41.0) 0.18 1.33 (4.5) (33.7) 3.78 (96.0) 135 0.02 0.10 (0.5 2.5) 0.98 (25.0) 1.31 (33.4) +1 +1 R 200 M = 0.8 Nm 0.51 (13.0) 1.02 (25.8) 0.18 (4.5) Ø0.17 (Ø4.4) Ø0.35 (Ø9.0) 0.59 (15.0) 1.16 (29.4) 83 0.02 0.12 (0.5 3.0) 1. (30.7) 0.89 (22.7) M = 0.8 Nm R 200 +1 +1 Switch must never be used as a mechanical stop. 12 Volume 8 Sensing Solutions CA08100010E February 2011 www.eaton.com

.1 Approximate Dimensions in Inches (mm) Safety Position Switches LS4...ZB 0.20 (5.0) 1.32 (33.5) 0.70 (17.8) 1.32 (33.5) M = 1.4 Nm 0.37 (9.5) 0.67 (17.0) 0.59 (15.0) 0.14 (3.5) 0.49 (12.5) M20 0. (5.3) 1.57 (40.0) 2.36 (60.0) 1.57 (40.0) 1.65 (42.0) 1.76 (44.7) 3.27 (83.0) 0.29 (7.3) 0. (5.3) 2.36 (60.0) 4M5 x 40 M5 Actuator Included with Switch Above 0.31 (7.8) 1.97 (50.0) 0.44 (11.2) 0.94 (24.0) 0.02 0.35 (0.5 9.0) 0.98 (25.0) 1.32 (33.5) 0.19 (4.8) 0.63 (16.0) R 400 Switch must never be used as a mechanical stop. 2.17 (55.0) 0.94 (24.0) 0.02 0.55 (0.5 14.0) R 400 Volume 8 Sensing Solutions CA08100010E February 2011 www.eaton.com 13