FP-5000 Feeder Protection

Similar documents
FP-5000 Series Multi-functional Microprocessor-based Feeder Protective Relay

FP5000. Refer to for the latest information on this constantly evolving product

Metering Devices IQ 300

INSTRUCTION LEAFLET IL E FP-4000 INSTRUCTIONS FOR THE FP-4000 PROTECTIVE RELAY

FP6000. Type ID Units Writable Possible Values. Count. TCP Register

Bus Bar Protection Relay B-PRO 4000

EDR-3000 Eaton Distribution Relay

DIAC/DIFC/DSFC. Single Phase Digital O/C. Single phase or ground overcurrent protection for industrial and utility power systems.

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

MIN II. Complete numerical ground directional protection. Digital Energy Multilin. Protection and Control. Monitoring and Metering.

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

Distribution Protection Relay

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

Protection Relays PHASE & RESIDUAL OVERCURRENT

Distribution Protection Relay

RT4F-120V/20A-WAC RECTIFIER

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

NewCode. Comprehensive Motor Protection and Control Relay. Relay Field Input and Output LEDs. LED Fault Indicators

RT4F-48V/50A-WAC RECTIFIER

MIC-2 Multi-instrument DATA SHEET

EDR-3000 Eaton Distribution Relay

NPW800R RETROFITTING. Power and Volatge Protection Relay

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

RT4F-110V/25A RECTIFIER

RT4B-110V/12A RECTIFIER

PMC 530 Series Advanced Multifunction Meter

SM100. On-Line Switchgear Condition Monitoring

BE1-50/51M TIME OVERCURRENT RELAY ADVANTAGES

H-series (Rectifier Module)

RT7-48V/6kW Specification

RT12-240V/2.4kW Rectifier Specification

EPM g Energy. Multilin BUILDING AUTOMATION POWER METER. BACnet /IP Communications and Energy Measurement KEY BENEFITS APPLICATIONS FEATURES

Electronic Submeter with Advanced WiFi Ethernet Capability

PRODUCT DESCRIPTION. Vertically cooled 2RU rectifiers with wide range of output modules available.

SECTION SWITCHBOARDS

FM2. Economical and compact feeder protection for low voltage feeders. Digital Energy Multilin. Monitoring & Metering. Protection and Control

PM800 series. Applications

ADDENDUM TO IB17555D INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE OF THE CUTLER-HAMMER DIGITRIP 3000 SERIES OF PROTECTIVE RELAYS

ADDITIONAL INFORMATION MODBUS INSTRUCTION MANUAL. Request publication Request publication DNP 3.0 INSTRUCTION MANUAL

Transformer Protection Relay

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

Feeder/ Motor Protection Relay VAMP 40

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

www. ElectricalPartManuals. com Protective Relays HIGHLIGHTS PROTECTIVE FUNCTIONS ixp-420 Transformer Protection Relay

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

ISGS. Intelligent SwitchGear System The Flexible Solution

PSL. Power Quality & Energy Monitoring. PQube power quality & energy analyzer. Low-Cost, High-Precision

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

SACE Emax 2 Specification guide

How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment?

BE1-51 BE1-51/27C BE1-51/27R TIME OVERCURRENT RELAY

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

www. ElectricalPartManuals. com Protective Relays PROTECTION AND CONTROL FUNCTIONS ADVANCED CAPABILITIES

RT9-48V/1.4kW Rectifier Specification

PowerLogic power-monitoring units. EM1000 series power meter. Technical data sheet

Revenue Grade General Specifications

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

SEL-551/SEL-551C Overcurrent and Reclosing Relay

www. ElectricalPartManuals. com l Basler Electric MPS100 MOTOR PROTECTION SYSTEM ADVANTAGES WINDOWS SOFTWARE ADDITIONAL INFORMATION

SIA-B. Overcurrent & Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered / Standard CTs. Main characteristics

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

Three-Phase Power Quality Analyzer PowerPad Model 3945

UW Purchase Specification Section

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

BFM-II BFM-II BRANCH FEEDER MONITOR. Highlights

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

www. ElectricalPartManuals. com MICROSHIELD O/Cä Multiphase Time-Overcurrent Relay Highlights

MICROSHIELD O/Cä Multiphase Time-Overcurrent Relay

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Feeder Protection Relay REF 610. Product Guide

Feeder protection relay SPAA 121 C. Product Guide

Multilin EPM 6010 YEAR. GE Grid Solutions. Building Automation Power Meter with BacNET /IP Communications. Monitoring & Metering

PowerLogic power-monitoring units. DM6000 series digital panel meters. Technical data sheet

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

Switching Control Sentinel (SCS) TM For all ABB independent pole operated circuit breakers

ACCESS 9340/9360 Meter Input/Output Module

Earth-fault Relay SPAJ 110 C. Product Guide

Multifunction Transducer MT440

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

BF 79 81

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

SFP450-12BG AC-DC Front-End Data Sheet 12V Output, 450 Watts

Circuit Breaker Sentinel (CBS) for SF 6. power circuit breakers

SECTION ( ) LIGHTING CONTROL PANELBOARD

MIC-2 MKII, Multi-instrument DATA SHEET

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

MPSC Microprocessor-based protection and metering devices for low voltage power circuit breakers. ABB Power Distribution

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

InteliPro. Protection Relay for Parallel Applications. Technical Specification

Medium Voltage Metal-Enclosed Power Capacitor Banks

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Request publication Request publication DNP 3.0 INSTRUCTION MANUAL. Request publication

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

MAJOR VA Power Inverter

Transcription:

Effective: April 2001 Page 1 New Information FP-00 Feeder Protection Contents Description Page FP-00 Description......... 2 Application Description...... 2 Features, Functions and Benefits.............. 4 Standards and Certifications.. 6 Communication Software.... 7 Catalog Ordering Information.............. 7 Feeder Protection FP-00

Page 2 Effective: April 2001 FP-00 Feeder Protection FP-00 Feeder Protection Feeder Protection FP-00 FP-00 Description Microprocessor-based protection with monitoring and control for medium voltage main and feeder applications. Current, voltage and frequency protection for electric power distribution systems. Complete metering of voltage, currents, power, energy, minimum/ maximum and demand functions. Programmable logic control functions for main-tie-main transfer schemes. Trip logs, event logs and waveform capture for better fault analysis and system restoration. Data Logger to provide energy usage profiles for better planning, utilization and energy usage. Compact, drawout case design. Meets ANSI, UL and CUL standards. Application Description The FP-00 Feeder Protection relay provides complete 3-phase and ground overcurrent and voltage protection plus metering in a single, compact drawout case. It may be used as primary protection on feeders, mains and tie circuit breaker applications, and as backup protection for transformers, high voltage lines and differential protection. The relay is most commonly used on medium voltage switchgear applications. The FP-00 takes full advantage of its microprocessor technology providing the user new freedoms and a wealth of data-gathering features. The relay performs self-checking of all major hardware and firmware protection elements to assure their operation in the event of a system or component electrical failure or fault. Protection functions are well suited for main and distribution feeder circuit applications. Programmable logic control functions make the FP-00 relay ideally suited for main-tie-main and main 1/main 2 transfer schemes. The Zone Interlocking feature can be utilized for bus protection instead of an expensive and complicated bus differential (87B) scheme. The FP-00 works directly with Cutler-Hammer s Digitrip 3000 and Digitrip MV relays. New breaker failure logic provides faster remote backup clearing times for stuck breaker operation. The FP-00 provides trip and close circuit monitoring and alarming features. It continually monitors the complete trip and close circuits for continuity and readiness to trip. Open and close pushbuttons are conveniently located on the front of the relay for local breaker operation. Loss-of-vacuum monitoring is activated when the breaker is open. Residual current is monitored and alarmed if detected. Phase CTs (3) Optional Zero Sequence CT Optional VT (1) CB 52 51P 51X 59 A 1 P 1 Trip Coil Monitor X 1 59 A 2 P 2 X 2 27 A 1 P 3 X 3 27 A 2 46 1 46 2 55A 55D When an electrical fault or disturbance occurs, the FP-00 begins to store the following in non-volatile memory: Voltage and current sampled data. Calculated values. Status of internal protection functions, logic, contact inputs and outputs. Retrieval and viewing of the data is easy, aiding in the quick analysis and restoration of your electric power system. When the FP-00 isn t responding to disturbances in the power system, it s providing valuable metering information at the relay and remotely. It provides energy usage and demand reading, and can alarm when usage reaches a set value. Power factor measurements can be used for cap bank switching to control kvar demand. Onboard data trending can provide load profiles for up to 40 days. The protection functions are listed below and shown in Figure 1. Phase instantaneous overcurrent with timers (P-1, P-2, P-3). Phase inverse time overcurrent (51P). Measured ground or neutral instantaneous overcurrent with timers (X-1, X-2, X-3). Measured ground or neutral inverse time overcurrent (51X). BF CALC 31o = IR 51R R 1 R 2 R 3 METERING V, I, F, PF, W, VARS, VA Energy Demand Min./Max. %THD Phasors Data Logger Waveform SER Fault Records FP-00 Main VTs (2) or (3) 59 M 1 59 M 2 27 M 1 27 M 2 47 1 47 2 81 U 1 81 U 2 81 O 1 81 O 2 Load Figure 1. FP-00 One-Line Drawing

FP-00 Feeder Protection Technical Data Effective: April 2001 Page 3 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 TB1 Input (+) Input ( ) Com. N.O. N.C. Alarm Com. Alarm N.O. Alarm N.C. RLY 5 Com. RLY 5 N.O. RLY 4 Com. RLY 4 N.O. RLY 3 Com. RLY 3 N.O. Trip 2 Com. 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 TB2 C In 1 C In 2 C In 3 C In 4 C In Source 1 C In 5 C In 6 C In 7 C In 8 C In Source 2 Not Used Not Used VA(+) Main VB(+) Main VC(+) Main 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 TB1 Factory Connection Only TB2 201 202 203 204 205 206 207 208 209 210 Red 211 White 212 213 214 215 216 217 218 TB3 TB3 J1-1 PowerNet J1-2 PowerNet J1-3 PowerNet Shield J2-1 Accessory Bus J2-2 Accessory Bus J2-3 Accessory Bus Shield J3-1 Zone Out J3-2 Zone Com. J3-3 Zone Shield J3-4 Zone In J3-5 Zone Com. 116 Trip 2 N.O. 216 Vx1 Aux 117 118 Trip 1 Com. Trip 1 N.O. 217 Vx2 Aux 218 Vg Main TB4 A1 B1 C1 X1 N.C. A2 B2 C2 X2 N.C. Figure 2. FP-00 Rear View and Terminal Designations Calculated ground or neutral instantaneous overcurrent with timers (R-1, R-2, R-3). Calculated ground or neutral inverse time overcurrent (51R). Ten standard time overcurrent curves (ANSI, IEC and Thermal). Breaker failure (BF). Phase unbalance negative sequence overcurrent (46-1, 46-2). Phase voltage unbalance and sequence protection (47-1, 47-2). Main 3-phase under/overvoltage (27M-1, 27M-2, 59M-1, 59M-2). Under/over frequency (81U-1, 81U-2, 81O-1, 81O-2). Auxiliary single-phase under/overvoltage (27A-1, 27A-2, 59A-1, 59A-2). Apparent and displacement power factor (55A, 55D). Zone interlocking for bus protection (87B). The FP-00 feeder relay includes a zone selective interlocking feature that can be used with other Cutler-Hammer devices like the Digitrip 3000 overcurrent relay. The FP-00 provides the following metering functions: Amperes (rms, phasor and sequence). Amperes demand and peak demand. Volts (rms, phasor and sequence). VA and VA demand. Watts and kw demand and peak demand. Forward/reverse/net kwh. Vars and kvar demand and peak demand. Lead/lag/net kvarh. Power factor. Frequency. Voltage and current. %THD and magnitude THD. Minimum/maximum recording with date/time stamp. Trending (load profile over time). The FP-00 provides the following monitoring and data recording functions that enhance the security of the protection system and provides useful information for scheduling maintenance. Trip circuit monitoring. Close circuit monitoring. Loss-of-vacuum monitoring. Breaker wear (accumulated interrupted current). Waveform capture (256 cycles total, up to 16 events). Fault data logs (up to 16 events). Sequence of events report (up to 100 events). Clock (1 ms time stamping).

Page 4 Effective: April 2001 FP-00 Feeder Protection The FP-00 provides standard control functions plus user-configurable custom control capabilities. This logic can be used for applications such as main-tie-main transfer schemes. Remote open/close. Optional local open/close. Programmable I/O. Programmable logic gates and timers. Multiple setting groups (up to 4). The FP-00 supports the following communication options: Front RS-232 port. PowerNet port (INCOM). Front RS-232 port and PowerPort software provides local computer access and a user-friendly, Windows based interface for relay settings, and configuration and data retrieval. Drawout case design for quick and easy relay removal and replacement. Breaker open/close control from relay faceplate or remotely via communications. Remote communications to Cutler- Hammer PowerNet monitoring system or PC. Free PowerPort utility software for local PC interface to the FP-00 for relay settings, monitoring and control. Features, Functions and Benefits Complete protection, metering and control in a single compact case to reduce panel space, wiring and costs. Flexible current, voltage and frequency protection and programmability to cover a broad range of applications while simplifying relay ordering and reducing inventory. Integral test function reduces maintenance time and expense. Relay self-diagnostics and reporting improves uptime and troubleshooting. Breaker trip circuit monitoring improves the reliability of the breaker operation. Programmable logic control features that can replace and eliminate external auxiliary relays, timers and wiring. Zone selective interlocking improves coordination and tripping times and saves money compared to a traditional bus differential scheme. Trip and event recording in nonvolatile memory provides detailed information for analysis and system restoration. 256 cycles of waveform capture aids in post fault analysis. PowerPort and PowerNet Protection Overview Screen

FP-00 Feeder Protection Technical Data Effective: April 2001 Page 5 (+) ( ) AC/DC 48-125V DC or 100-120V AC C B A FP-00 2 Relay Failure Alarm 101 102 103 104 105 106 TB1 Input (+) Input ( ) Com. N.O. N.C. Alarm Com. TB2 C In 1 C In 2 C In 3 C In 4 C In Source 1 C In 5 201 202 203 204 205 206 1 52A 52B 52B TOC Breaker Alarm 107 Alarm N.O. C In 6 207 108 Alarm N.C. C In 7 208 3 Breaker Close 109 110 111 RLY 5 Com. RLY 5 N.O. RLY 4 Com. C In 8 C In Source 2 Not Used 209 210 211 112 113 RLY 4 N.O. RLY 3 Com. Not Used VA(+) Main 212 213 5 114 RLY 3 N.O. VB(+) Main 214 115 Trip 2 Com. VC(+) Main 215 116 Trip 2 N.O. VX1 Aux 216 52A 52 TC 52A 117 118 Trip 1 Com. Trip 1 N.O. VX2 Aux Vg Main 217 218 Ground X2 X1 A2 A1 B2 B1 C2 C1 4 Load 52 1 For maximum breaker diagnostics use both 52A and 52B contacts. Some diagnostics are not available if only one of the two is used. 2 A relay failure alarm should provide immediate attention as circuit is no longer protected. Relay failure output is normally energized. C B A 3 4 5 FP-00 can initiate a breaker close via the front panel interface and/or remote activation through communication or discrete input. Residual connection may be used in place of zero sequence CT. Delta or open delta PT connection may be used in place of wye-ground connection. Figure 3. FP-00 Typical Connection Drawing Using Wye PTs

Page 6 Effective: April 2001 FP-00 Feeder Protection Feeder Protection FP-00 Operational Breaker Closed Breaker Open Reset Monitor View Setting Log Status/Control Previous Enter Phase Trip Ground Trip Other Trip Alarm Pickup Auxiliary Set Test Close Open Breaker Figure 4. FP-00 Front View and Drawout Case Side View Standards and Certifications Compliance UL Recognized, File # E154862. UL 1053 (1994) Recognized. ANSI C37.90 (1989). EN 511 (1991). EN 61000-6-2 (1999). Emission Tests EN 511 (1991) Group 1 Class A (CISPR-11, Class A). FCC 47 CFR Chapter 1 Part 15 Subpart b Class A. Immunity Tests ANSI C37.90.1 (1989) Surge Withstand Capability. ANSI C37.90.2 (1995) EMI Immunity to 35V/m. EN 61000-4-2 (1995) ESD Rating of 8 kv. EN 61000-4-3 (1997) Radiated EM Field at 10V/m. EN 61000-4-4 (1995) Fast Transient Burst at 2 kv. EN 61000-4-5 (1995) Surge Immunity Test. EN 61000-4-6 (1996) Conducted RF at 10V/m. EN 61000-4-11 (1994) Voltage Dips and Variations. Control Power Nominal voltage: 48/125V DC or 120V AC Operating range: 38 to 1V DC or 69 to 132V AC Interruption ride-through time: 20 cycle interruption of nominal AC supply Power consumption: 20 VA maximum Current Inputs Nominal (I n ): 1A or 5A CT rating: 2 x I n continuous x I n for 1 second CT burdens: < 0.25VA at 5A (nominal) < 0.05VA at 1A (nominal) Voltage Inputs Nominal: 120V AC Operating range: 69 1V AC Burden: <0.015 at 120V AC. 1 megaohm Metering Accuracy Phase current: ±0.5% or ±0.025A from 0.02 to 20 per unit fully offset current waveform Ground current: ±0.5% of full scale (I n ) from 0.02 to 2.0 per unit fully offset current waveform Phase voltage: ±0.5% or ±0.2V from 0 160V AC Frequency measurement accuracy: ±0.02 Hz Phase angle: ±1º Power metering accuracy: ±1.5% Metering accuracy temperature range: 0ºC to ºC Temperature range: ±5% for operation below 0ºC and above ºC Input signal frequency necessary for accurate operation: 60 Hz nominal, 57 63 Hz (±5%) Hz nominal, 47 53 Hz (±5%) Clock accuracy: Free running ±1 minute/month at 25ºC. Clock automatically updated by PowerNet host when present.

FP-00 Feeder Protection Technical Data Effective: April 2001 Page 7 Protective Functions Phase and Ground Overcurrent Protection Inverse characteristics: Mod, Very, Extremely, IECA, IECB, IECC, It, I 2 t, I 4 t, Flat TOC (51) pickup range: 0.1 to 4.0 per unit in 0.01 steps Time multipliers: 0.05 to 10.0 in 0.01 steps IOC () pickup range: 0.1 to 20.0 per unit in 0.01 steps Pickup accuracy: ±1% (at 0.1 2 per unit) Time accuracy: ±3% or ±30 ms Voltage Unbalance (47) Threshold (minimum voltage) 1 to 100 volts in 1 volt steps. % V2/V1: 4 to 40% in 1% steps Current Unbalance Threshold (minimum current) 0.1 to 20.0 per unit in 0.01 steps. % I2/I1: 4 to 40% in 1% steps Under/Overvoltage Protection Pickup range: 10 to 1 volts in 1 volt steps Under/Over Frequency Protection Pickup range: 45 to 65 Hz in 0.01 Hz steps Breaker Failure Protection Pickup range: 0.1 to 5.0 per unit in 0.01 steps Power Factor Trigger/reset threshold: 0.5 lag to 0.5 lead in 0.01 steps 0 to 1000 seconds in 1 second steps Discrete Inputs Number of contact inputs: 8 Rating: 48V DC wetting voltage provided with internal ground only Output Contacts Number of output contacts: Five Form A and two Form C Rating of Output Contacts Momentary: Make 30A AC/DC for 0.25 seconds Break 0.25A at 2V DC (resistive) Break 5A at 120/240V AC Continuous: 5A at 120/240V AC 5A at 30V DC Logic and Control Functions Six programmable logic gates for AND, OR, NAND, NOR operation. Two latching (flip/flop) gates. Six timer gates provide on/off delays. INCOM Communications Baud rate: 9600 fixed Maximum distance: 10,000 feet (3,048m) Protocol: INCOM Accessory Bus: Baud rate: 9600 fixed Maximum distance: 10,000 feet (3,048m) Protocol: INCOM RS-232 Communication, Front Panel Baud rate: 38.4k, 19.2k, 9.6k Connector standard 9-pin subminiature, 3-wire. Protocol: INCOM Environmental Ratings Operating temperature: -40ºC to +60ºC (-40ºF to +140ºF) Product tested to +85ºC Storage temperature: -40ºC to +85ºC (-40ºF to +185ºF) Humidity: 5% to 95% relative humidity (non-condensing) Altitude: 0 to 6,3 feet (0 to 2,0m) above Mean Sea Level Dimensions Behind Panel Height: 6.7 inches (170.2 mm) Width: 5.3 inches (134.6 mm) Depth: 6.9 inches (175.3 mm) In Front of Panel Height: 11.34 inches (288.0 mm) Width: 7.72 inches (196.1 mm) Depth: 0.80 inches (20.3 mm) Weight 12.5 lbs. (5.7 kg) Communication Software Cutler-Hammer provides two types of communication software. The first is PowerPort. It runs on a PC or laptop for easy access to a single relay to change set points or configuration and to view metered values and stored data. PowerPort is free and can be downloaded from the Cutler-Hammer web site at the following URL: http:// www.ch.cutler-hammer.com/pmp/ powerport.html The second package is PowerNet. PowerNet is a power management software package that is designed for continuous, remote monitoring of many devices. It provides all the functionality of PowerPort plus additional functions such as billing, trending and graphics. Contact your local Cutler- Hammer representative for more information on PowerNet software. Catalog Ordering Information Table 1. Catalog Ordering Information Description Catalog Number Feeder protection with 5 ampere CT input, 48 to 125V DC or 120V AC FP-00 outer case renewal part. FP-00-00 inner chassis renewal part FP00-00 FP00-OC FP00-00-IC Copyright Cutler-Hammer Inc., 2001 All Rights Reserved.

Page 8 Effective: April 2001 FP-00 Feeder Protection TD17D01TE Printed in U.S.A. / Z01797