Eaton 93PR UPS kw

Similar documents
Eaton 93PM UPS kw

Power Quality Solutions Eaton 93PR UPS

Product Brochure Eaton 93PR UPS kw

Product Brochure Eaton 93PR UPS kw

Eaton 93PM: Value, Benefits, and Features Eaton. All Rights Reserved..

Eaton 93PM UPS Efficient. Scalable. Innovative.

Eaton BladeUPS 12 60kW

Help your Cisco customers defend against downtime and reduce costs

Mid-Sized Data Center UPS Solutions Overview

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Manage power your way

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

Zero downtime for mission critical applications? Absolutely.

Socomec Netys PR RT U P S TOWER / RACK MOUNT

Symmetra PX. Symmetra PX 48kW Scalable from 16kW to 48kW. Modular, Scalable, High-Efficiency Power Protection for Data Centers

Infrastructure with intelligence

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

ICT Infrastructure Solutions. Real power for virtualisation

PRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 100kW 3MW

MODULAR UPS SYSTEM KVA

The Power of Modularity

Modular three-phase UPS system. Conceptpower DPA kva True modular UPS system for critical applications

Est FlexiPower Maxi UPS FPX Maxi kVA

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

Product brochure. Eaton 9PXM UPS. A scalable, modular, flexible solution for a wide range of applications. Plan > Grow > Manage

Power Quality Solutions. Powering your FlexPod environment

Eaton 9EHD Industrial UPS

Business continuity made easy

Est FlexiPower Ultra UPS FPX Ultra kVA

PRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 20kW 600kW

Eaton 9EHD Industrial UPS

Power+ Family Products. P+ Family Products: Seth Davis- Global Marketing Manager

Product brochure. Conceptpower DPA Modular UPS DPA 120 UL 208V: 20kW 600kW

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

Liebert GXT MT kva

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

Mission Critical Power Review

GAMATRONIC, A SolarEdge Division.

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups

THOR Modular. Modular UPS system. Online double-conversion Scalable Decentralized Parallel. Modular. 10, 20, 30, 40kVA modules kVA systems

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers

Eaton 93PM UPS Efficient. Scalable. Innovative.

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1, Tower 208/240V Input, 208/240V and 120V Output

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

Schneider Electric Easy UPS 3S

Converged Power Solutions. Data center power reinvented

Multi Power x 42 kw up to 1 MW + redundancy 3:3 VFI TYPE. Utmost Availability Ultimate Scalability Unmatching Power Density

TME Modular Series UPS System kva/kw - 208/220 VAC

PowerWAVE 9250DPA. ( N+1 kva/kw) Parallelable up to 1.5 MVA/MW

Repeatable IT Hub Rooms

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments

Tel: AC Power for Business-Critical Continuity TM

Modular and Scalable Power Converters in the UPS Industry

MP7. Uninterruptible Power Supply

MUST 900 UPS. Finally the benefits of Modular ups are for all. 3 Phase Modular. Hot swappable, scalable 30kVA to 900kVA

Powerware 9315 Hot Sync Parallel Capacity System Bypass Module (SBM)

Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Modular, scalable, high-efficiency power protection for data centers

Kohler EW 6000TX. Transformer-based. (UPS kVA)

Eaton kva Eaton kva Scalable. Compact. Flexible

Liebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM

Powerware 9910-P11 and 9910-P16

Eaton 93PM UPS Efficient. Scalable. Innovative.

MUST900 Modular UPS. Datacenter & servers. Internet centers. Local Area Networks (LAN) Telecommunication devices. Emergency application

the Centric 300 An advanced modular UPS up to 1800kVA/kW

Powerware P95

Schneider Electric Easy UPS 3S

9155 UPS mdspower.com

Eaton 93E UPS Simple power management for every IT environment.

Newave s approach for protecting mission critical application

Galaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Liebert GXT4 UPS, 5kVA-10kVA Intelligent, Reliable UPS Protection

Intelligent Power Distribution

Single phase UPS. Applications. Highlights. 1ph from 450 VA to 10 kva. Home Office Computers and peripherals Networks and servers Small data centers

Cisco CRS 16-Slot Chassis Power Systems

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

Est FlexiPower Maxi. Modular UPS kw

Intelligent Power Software Manage your power easily

UPS Sentry MPS. SENTRY MPS is also compatible with different battery technologies: openvase lead acid and AGM and Gel VRLA, NiCd.

IP Telephony. Contact Centers. Mobility. Services Avaya Overview Brochure

Modular, scalable, high-efficiency power protection for data centers

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads

Repeatable IT Hub Rooms

Product Snapshot. The Powerware Uninterruptible Power System. Product Focus

SMARTONLINE E3 UPS SYSTEMS

Liebert APM. The Compact, Row-Based UPS with Flexpower Technology 30kW - 300kW

Powerware P64

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY

High Reliability & Efficiency

Intelligent Power Software

Liebert. EXS from 10 to 20 kw. Optimized and integrated three-phase UPS solution with high efficiency power protection

Galaxy VM. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Building a power monitoring and management strategy Selecting the software and services needed to keep critical power systems continuously available

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Smart-UPS On-Line. 2 nd Generation 3-10 kva Offer Technical Overview

EP Series II UPS 230 V

Transcription:

Eaton 93PR UPS 25 200 kw The most advanced UPS for data centers and mission critical applications

93PR 25-200 kw Contents Why the 93PR Product range Maximum Availability Lowest TCO Product Detail 2 2

3 phase UPS portfolio - EA Why 93PR? 3 3

Business Challenges of CIO Today Business continuity What kind of protected power your data center consume? And how long downtime your business can survive Predictable IT In this fast changing technology and business environment today, can you predict your IT requirements next 3 years? Right size your starting point and growth plan of your data center power. Save operation cost We care about how much electrical bills we can save for you. 2012 Eaton Corporation. All rights reserved.

What kind of POWER your IT need? Reliability Flexibility Your Data Center Consume Power & Network all the time Eaton cares about: 1. Shorten IT/ business downtime 2. Whether your protected power can support your business growth? 3. Your electrical bills. Efficiency 2012 Eaton Corporation. All rights reserved.

93PR & it s solution The Solution, 93PR: Legendary reliability of Eaton 93 Series. Hot Swappable, Pay as You Grow Easy deployment and Service Highest efficiency, to save operation cost Support 25~800KW load Eaton Patent Technologies: Hot Sync, ESS, ABM, VMMS 6 6

Business Values Reliability Business Continuity Flexibility Business Agility Efficiency Total Cost of Owner Ship Powered by Eaton provide business values to customers, and solve problems CIO meet today and tomorrow! 7 7

Identify an Opportunity - Tower vs. Modular Plan with customer - the modular / scalable solutions from very beginning. Transit TOWER to MODULAR Items Tower Modular Cost by redundancy 2N take advantages Pay as Grow Hard Easy Save upfront cost when FIXED KVA in long term N+1 with unpredictable IT. Plug in and out base on real usage. Efficiency Depends on % of load Higher % of load 8 8

How to WIN modular solutions Engage Earlier Build up values of modular/scalable solution. Influence budget & architecture Focus on Value, not price Solution driven rather than product/ category selling Future Plans Growth plan align with Business/ IT Upfront cost savings and electrical bills. 9 9

Distributed Critical Power Solutions Ease of Deployment: Modular/Scalable In-row & line and match solutions Small footprint: Compact design and internal redundancy High efficiency with thermal management: Providing the lowest TCO 10 10

3 phase UPS portfolio - EA The 93PR Concept 11 11

Eaton value proposition Safety Regulatory compliance Personnel ALWAYS safe Virtualization & Cloud readiness Bridge IT and electrical infrastructure Hardware & software...convergence Resiliency It s all about availability Service Level Agreements / Selectivity Efficiency Cost pressure Environmental oversight Scalability Need to optimize capital expenditure Need to react fast to customer needs 12 12

93PR - Concept Frame introduction 13 13

93PR Concept Ultramodular Power ratings: 25,50,75,100,125, 250,175,200 kw Modular design: 25 kw hot-swappable modules The system can automatically identify the UPM quantity and system rating 14 14

93PR Parallel Tie cabinet 15 15

3 phase UPS portfolio - EA 93PR Maximum availability 16 16

93PR Maximum availabillity Safety design Design and selection focuse on safety, such as to select Bussmann fuse. Redundance design: Such as Fan, System PS. Ambient temperature:0 C to + 40 C without output power de-rating 17 17

93PR - Maximum availabillity Hot swap and hot scalable A module can be replaced while the others continue protecting the load (concurrent maintenace) A module can be added while the others continue protecting the load (hot scalable) No need to go to bypass for replacement/upgrade (MTTR =0) Syetem maintenance can be typically performed in less than 10 minutes Procedure to be conducted by professionally trained personnel (Safety first) 18 18

93PR Maximum availabillity HotSync parallel technology Patented method for load sharing Peer-to-peer control strategy Each UPM/unit synchronises independently Erases single point of failure Ensure vertical and horizontal upgrade No master-slave configuration No load share signals Selective tripping Enhanced reliability UPS Module #1 UPS Module #2 UPS Module #N 19 19

93PR - Maximum availabillity Extensive availability of comm. protocols Optional Optional Network Card-MS Industrial Relay card PXGMS card Web/SNMP Industrial grade relay card Web/SNMP/Modbus card Software support: IPP, IPM Legacy: NSM, NetWatch 5 LanSafe (requires settings in card) Other features: Email alarms SNMP v 3, IP v 6 SNMP with Pulsar MIB, Power MIB and standard UPS MIB (RFC 1628) Temperature, humidity and 2 status inputs through Environment Sensor (optional) 5 output relays, 1 digital input Connections 250 V/5 A Switching relays (NO/NC) Isolated Terminal block connections Based on PowerXpert Gateway platform Software support: IPP, IPM Other features: Email alarms SNMP v 3, IP v 6 with Power MIB and standard UPS MIB (RFC 1628) ModBus RTU and TCP BACnet IP Temperature, humidity and 2 status inputs through Environment Sensor (optional) 20 20

93PR - Maximum availabillity Extensive availability of comm. protocols Sofware communications & Connectivity Three MiniSlots for additional connectivity hardware Host and device USB port Five building alarm inputs and dedicated EPO Relay alarm output (more available as option) 21 21

3 phase UPS portfolio - EA 93PR Maximum availability Cloud & Virtualization-ready UPS 22 22

93PR - Maximum availability Cloud & virtualization ready View, monitor and administer not only physical and virtual servers, but UPSs, PDUs and other power devices through one console Receive network- and power-related alerts through their virtualization management application Shut down virtual servers as well as physical ones automatically and gracefully during power failures Automatically suspend non-critical virtual machines, consolidate critical loads on fewer host servers and shut down unused host servers 23 23

93PR - Maximum availability Integration with leading IT vendors Eaton s Intelligent Power Software Suite integrates with leading including virtualization and storage platforms: Intelligent Power Management (IPM) and Intelligent Power Protector (IPP) View host servers, storage AND power devices from a single pane of glass 24 24

Eaton Intelligent Power Manager Intelligent Power Protector epdu ETHERNET SNMP device Intelligent Power Manager 25 25

Single pane of glass management Intelligent Power Manager vcenter Web client widget vcenter plugin & power events 26 26

Load shedding 50% drop in load equates to 150% more runtime! ZONE 1 Suspend non-critical virtual machines Consolidate critical virtual machines Power cap Cisco UCS devices Graceful shutdown non-critical VMs / vapps Dynamically power cap Cisco UCS devices ZONE 1 vmotio n ZONE 2 Move critical VMs to unaffected zones Works with VMware Distributed Power Manager 27 27

Eaton Software Competitiveness IPM Feature End User Benefit Eaton IPM/IPP Second best Server shutdown Plugs into Virtualization Platforms - tab (traditional vsphere client) Graceful Shutdown of VMs and host servers in case of power failure Higher productivity - view from single plane of glass Plugs into Virtualization Platforms vcenter web client VMware s new method Higher productivity - view from single plane of glass - works with VMware's future look of vcenter Power capping with Cisco UCS Manager Extends battery run time Agentless server shutdown Storage shutdown Achieve shutdown function from one point with less setup work Can send signals to NetApp storage devices for shutdown as appropriate Converged infrastructure compatibility vblock Ready, NetApp Flexpod, EMC VSPEX Disaster recovery/avoidance Works with VMware Site Recovery Manager to initiate planned migration to back-up site on power event notification with no data loss Localisation User interface supports multiple languages 28 28

3 phase UPS portfolio - EA 93PR Lowest Total Cost of Ownership 29 29

93PR The most efficient UPS in its class 99% efficiency with Eaton s advanced algorithms Energy Saver System (ESS) is a propietary technology that monitors the grid and automatically selects the optimal power protection option Continuous monitoring of UPS output voltage and transfer to double conversion mode within ~2 ms when needed Inherent filtering against fast low energy transients Lifetime of UPMs components will increase (fans, capacitors, electronics) ECO 30 ESS 30

93PR The most efficient UPS in its class ESS- How does it work? UPM:s (rectifier and inverter) in ready state mode Rectifier and Inverter contactors are closed, DC-link primed through IGBT diodes Efficiency ~99% from 30% partial load and up Continuous monitoring of UPS output voltage and transfer to double conversion mode within ~2ms when needed Lifetime of UPM:s components will increase (fans, capacitors, electronics) Fans are off, when UPM running on ready state Transfer from ESS to Double Conversion and back with push button or externally using building input (lightning detector etc.) 31 31

93PR The most efficienct UPS in its class Optimized double conversion efficiency Load optimized double conversion efficiency with automatic variable power module management System automatically suspends and engages modules to optimize efficiency Available at both UPS and system level 32 32

93PR The most efficient UPS in its class The highest double conversion efficiency For single modules and applications where ESS is not optimal then the 93PR still offers the highest double conversion in the market Based on its 3-level converter topology the 93PR achieves above 96% efficiency levels (IEC 62040-3) Double conversion provides maximum protection in challenging environments (supply or load) 33 33

93PR Advanced Battery Management (ABM ) prolong battery life about 50% Advanced Battery Management (ABM ) ABM charging algorithm prolongs battery service life Load adaptive battery cut-off voltage optimises system battery set-up to the actual load 34 34

93PR Maximum scalability Year 12 125kW 175kW Year >2 300kW Future, more rating Scalability and flexibility Reducing the amount of time required to scale up in response to increased demand from days to minutes (hot swap) Scaling up without affecting the footprint to save floorspace Optimizing CAPEX Pay as you grow Internal redundancy for high availability HotSync technology for reliable and resilient load sharing Each UPM in the system operates independently External redundancy for improved scalability Parallel up to 4x frames (possibility up to 8) Total system size up to 800kW (1600kW) 35 35

93PR Inherent redundancy Due to its modular design the 93PR can provide redundancy at UPS level generating significant savings in footprint, cooling and electrical installation Can be configured N+0,N+1 and N+2, such as 200kW, 175KW+25kW and 150kW+50kW. Did you know that by buying a modular design you can save up to xx % of your initial investment A typical data center will upgrade in 2 years. 36 36

93PR ECT(Energy Saving Technologies ) Easy Capacity Test Provides savings in annual battery autonomy tests Reduces amount of work and need for rental equpiment (load bank, cabling) Power discharged from the batteries is fed to other loads in parallel UPS system through static switch Savings in energy consumption AC DC AC DC DC DC DC AC DC No need to transfer the load to other systems DC DC AC Concurrent maintainability Maximised availability Less risk for business 37 37

3 phase UPS portfolio - EA 93PR Product Detail 38 38

93PR front view 1 Communication-3 slots, 5 building alarm. 1 2 7 2 Parallel cable terminal 3 Input Switch 4 8 4 Classic Efficiency (>96%) UPM 5 Optional internal maintenance switch 6 200kW static bypass switch 3 5 7 7 LCD Touch Screen Display 8 LPS 2012 Eaton Corporation. All rights reserved. 6 93PR 200kW front view 39

93PR open door rear view 1 1 Top cable entry 2 Bottom cable entry 3 Cable terminal 4 48V trip terminal 3 4 2 93PR 200kW rear view 2012 Eaton Corporation. All rights reserved. 40

UPM overview 1 2 3 Handle Fans Battery start button LED Indicator 6 4 Fan and capacitors that can be disassembled easily 5 6 UPM lock Hot swap connection 2 3 4 1 5 UPM is shipped separately 2012 Eaton Corporation. All rights reserved. 41

93PR family overview 2012 Eaton Corporation. All rights reserved. 42

93PR summary 43 43

44 44