FiberLink 6650 Series

Similar documents
FiberLink 5002 Series

FlexPOD. Fiberlink. Flexible Passive Optical Distributor. User s Manual. Artel Video Systems Fiberlink FlexPOD. Fiberlink FlexPOD is a

6400 CWDM Series. Fiberlink. 4 or 8 Channel Coarse Wave Division Multiplexers for Single Mode Fiber. User s Manual

5100 Series. Fiberlink. 10/100/1000 Base-T Etheret over one or two single mode or multimode fibers. User s Manual

OPERATIONS GUIDE OWL

Ra Series Fiber Optic Test Instruments

HDMI VIDEO SYSTEM USER S MANUAL

AF-OLK5A Series Fiber Optic Test kit

HD-CVI / AHD / HD-TVI Video + Bi-Directional Data

LTS-2A LTS-10 LTS-10C LTS-11 LTS-12

Operation Manual for OPM-1315 Optical Power Meter

Operation Manual for OLS-1315 Optical Light Source

6100E Series DIGITAL FIBER OPTIC MULTI-CHANNEL AUDIO TRANSPORT SYSTEM

RA3211 PON optical power meter

FIBER. WP-TEST-FIBER-400 Optical Power Meter Owner s Manual

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

RA3301Optical Multimeter

KI6501 Optical CWDM Power Meter. User Manual. KI6501 series Optical CWDM Power Meter

Handheld Optical Power Meter. Model SSF-TKITP-400 OPTICAL POWER METER. Manual

PM-212-SI3 Pocket Optical Power Meter INSTRUCTION MANUAL

VIAVI. OLA-54 and OLA-55. SmartClass. Data Sheet. Optical Level Attenuator. VIAVI SmartClass optical handhelds go beyond the basics.

LBO-H2 Series DIRECT PLUGGABLE LINKBRIDE TM FIBER OPTIC HDMI 2.0 TRANSMISSION SYSTEM

PM-204A/B. Power Meter. Operation Guide

VIAVI SmartClass OLA-55M

CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide

Handheld Video Microscope

10G SFP+ Checker 2012 VER B. Page 1 of 9 3F-5, No. 30 Taiyuan Street, Chupei City, Hsinchu County 302, Taiwan

PM-100 SERIES. Operation Guide. Power Meter V

KI Channel Optical CWDM Power Meter. User Manual. KI6503 series 48-Channel Optical DWDM Power Meter

Technical Specification. for. 10 Gbps SFP+ Checker

LEAD Fiber Optics PRODUCT CATALOGUE

PM-212-MPO Pocket Optical Power Meter INSTRUCTION MANUAL

OTS-400 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities A LANscape Solutions Product

PM-800 Optical Power Meter INSTRUCTION MANUAL

Testing Optical Feeds in Wireless Systems Remote Radio Units (RRU) and Distributed Antenna Systems (DAS)

HCC-CW-201A. CWDM Analyzer. Operation Guide

FTE-6000 Hand Held Tuneable Laser Source

Model RP450. Optical Power Meter

SCT-MMA / SCT-SMA Fiber Optic Adapters

OTS-400 Series Optical Meters, Sources and Testers A LANscape Solutions Product

FiberBasix 50 Handheld Testers

KI 2400/2800 SERIES HAND HELD FIBER SOURCE FEATURES. kingfisher.com.au. OPTICAL COMMUNICATIONS TEST APPLICATIONS (in combination with a power meter)

Annexure-I: Technical Specification of Handheld Optical Power Meter Purchase Ref: Parameter ITI Specification Vendor-1 Vendor-2 Vendor-3 Remarks

+ + Swift F1+ is a way on future splicers.

OPM-50 Optical Power Meter User s Manual

Rev. F January 13, 1999 Part Number: OFL Operations Manual for the OFL 100 Mini-OTDR

DIGITAL DIRECTIONAL INLINE OPTICAL POWER MONITOR/METER

Gigabit Miniature Media Converters. Connect Gigabit Ethernet copper ports to fiber optic cable.

OLP-55 Sm a r t Optical Power Meter A Sm a r t, Future-Proof Optical Power Meter

Training Training Manual: Manual: KI9800A Series Pocket Fibre Sources Level 1

3M Fibrlok Optical Splice System

LTS-1 LTS-1C LTS-2 LTS-5 LTS-6 LTS-7 LTS-10 LTS-11 LTS-12. Wilcom. Optical Loss Test Kits. Description LTS-2

FOCIS Flex - No Wireless Fiber Optic Connector Inspection System User Guide

Module Connectors and Cable Specifications

TOM103. Optical Power Meter OPTICAL POWER METER

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com. FiberTEK III

Optical Power Meter MT-7603

VIS Video Inspection Scope

OPERATOR MANUAL OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE

RIFOCS Corp. Component Services Division

AFC-3000 Automated Optical Connector Ferrule Cleaner

Datasheet: FI-500 FiberInspector Micro-Fiber Optic Endface Inspection Scope with PortBright Illumination.

High Precision Fusion Splicer

PPM-30 PON Power Meter. User s Manual. Shineway Technologies, Inc. All rights reserved.

Datasheet: Fiber OneShot PRO Singlemode Fiber Distance and Fault Locator; Fiber QuickMap Multimode Fiber Distance and Fault Locator

OFS 300 Optical Fiber Scope User s Guide

OTS-600 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities

SC/APC Connector. CATV Active device Telecommunication. Metro Local Area Data processing

GVIS Video Inspection Scope

Optical Power Meter With VFL. User Manual

OTEB-CO-P PRE-AMP EDFA INSTRUCTION MANUAL

FEB 2017 Rev F. Verify that all cable assemblies are in good condition.

Installing the Fiber Optics Card

A Quick Start Guide to Fiber Inspection, Cleaning, and Test

USER MANUAL FOT-PM Optical Power Meter

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

OPTICAM 2 QUICK SETUP GUIDE

VISIBLE FIBER OPTIC FAULT LOCATOR

C2000 POWER METER With Data Storage

Mini OTDR MOT-700 USER MANUAL

Polymer Coated Fiber Cable (PCF)

OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE

HIGH-SPEED PHOTODETECTOR. Thorlabs item # SIR5-FC

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM

Optical CWDM Power Meter

SmartPocket Optical Power Meter OLP-34/35/38

Thermal Imaging Camera 220 x Instruction Manual

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

Power Over Fiber USER GUIDE. SYSTEM INSTALLATION INFORMATION Description. The leader in rugged fiber optic technology. RLH Industries, Inc.

Optical Power Meter. TrendCommunications. User Guide Testing the World s Networks

OLS-55/56 Sm a r t Optical Laser Source A Sm a r t, Future-Proof Optical Laser Source

CS Contractor Series Live PON OTDR

LEAD Fiber Optics PRODUCT CATALOGUE

Specialized Solutions for Fiber Optic Testing

OptiFiber Certifying OTDR Accessories Guide. See how Fluke Networks options and accessories can enhance your investment.

AQ2170 Optical Power Meter

- Optical FAQ Highway 108 Sierra Village, CA Telephone: (800) Fax: (209) Optical Connectors:

HDMI and Ethernet Extender via 2 Multimode Fibers LC Duplex Connector Extends HDMI+ 10/100M Ethernet Link Up To 800 Meters

AE3100 Series User Manual. Version 1.02

JDSU Optical Handheld Testers. Family of light sources, power meters, attenuators, loss test sets, return loss meters, and optical talksets

Transcription:

MANUAL FiberLink 6650 Series Optical Power Meter Installation and Operations Manual WWW.ARTEL.COM

Contents Contents Welcome... 3 Features... 3 Package Contents... 3 Technical Specifications... 4 Applications for FiberLink 6650.... 5 Functions... 6 Measuring Optical Loss... 8 Operating Pointers... 10 Troubleshooting... 10 Maintenance and Repairs... 11 Page 2

Welcome Features Package Contents Welcome The FiberLink 6650 Optical Power Meter is a high accuracy, high resolution, microprocessor controlled optical power meter. It has a wide 65 db dynamic range, and is calibrated to measure 850, 1300, 1310, and 1550nm, making it ideal for both single mode and multimode fiber testing, as well as 1490nm for measurement of FTTx PON networks. Features InGaAs photodetector with 2.5mm universal adapter for ST, SC, FC, and other 2.5mm connectors, 1.25 mm universal adapter for LC connectors 65 db dynamic range; calibrated to measure 850, 1300, 1310 and 1550nm Works with multimode and single mode fiber Graphical LCD display with intuitive user interface Simple 2-key operation Power measurements shown in dbm, db, or microwatts Display resolution of 0.01 db Long battery life - up to 250 hours on one 9v battery On screen battery indicator Comes equipped with a rugged and durable rubber boot to protect the instrument from drops and other hazards Optional ruggedized carrying cases available to accommodate 3 or 6 test devices Package Contents One FiberLink 6650 This User s Manual One Non-Rechargeable Lithium Battery (Pre-installed in unit) 2.5mm universal adapter (Pre-Installed on unit) 1.25 mm universal adapter for LC connectors Page 3

Technical Specifications Technical Specifications Specifications Measurement Range: Absolute Accuracy: Resolution: Linearity: Wavelengths: Fiber Types: Connector: Power Requirements: Dimensions: +5 to -60 dbm +/- 0.15 db over range of 0 to -45 dbm 0.01 db +/- 0.20 db over range of 0 to -45 dbm 850, 1300, 1310, 1490, 1550nm Single Mode and Multimode InGaAs photodetector with 2.5mm universal adapter (ST, SC, FC, and other 2.5mm connectors), and 1.25mm universal adapter (LC connectors) 9 Volt battery or optional Power Supply for use with rechargeable battery 4.94 x 2.175 x 1.28 (inches) Page 4

Applications Applications for FiberLink 6650 Optical Power Meter Below is a list of test and measurement applications that can be performed using the FiberLink 6650 optical power meter. Active Equipment Optical Power Measurements: Active equipment should be measured periodically for correct power levels. The transmitters in this equipment have a known power value. The FiberLink 6650 can be directly attached to this equipment via a patch cord to check whether the transmitter is within the manufacturer s specified power range. Fiber Continuity Testing: Continuity can be measured with the FiberLink 6650 by placing a calibrated light source on one end of the fiber and the FiberLink 6650 on the other end. This is also a simple way to measure the attenuation of the fiber. Patch Cord Testing: Optical links that are producing incorrect or poor results may have bad patch cords. The FiberLink 6650 can be used to test the attenuation of a patch cord to see if it is usable, or should be replaced. Attenuation (Optical Loss) Measurements: After a fiber cable has been installed and terminated, it must be tested to determine if the fiber is installed according to standards and specifications. A comparison of the actual power measurement and the reference value determines if the installation will pass or fail. Page 5

Functions 1 2 1 2 3 4 5 Page 6

Functions 1 Battery Charger Port: Allows for charging of rechargeable 9 Volt batteries, as well as wall power operation (Power Supply optional and not included. 9 Volt re-chargeable battery not included). Do not use battery charging port with non-rechargeable batteries. There is the potential for explosion and damage may occur to the unit and/or the user. 2 3 4 5 1.25/2.5mm Universal Connector Port: Accepts many popular 1.25mm and 2.5mm ferrule connectors, including ST, SC, FC and LC. LCD Screen: Shows optical power/loss levels, power units, wavelength, and battery status. Wavelength Selector / Power Button: Single press changes wavelength; holding the button powers the unit ON or OFF. Unit Selector / Zero Button: Single press toggles the measurement units between dbm, db, and uw; holding the button sets the reference for the selected wavelength. Page 7

Measuring Optical Loss Transmitter Patch Cable Transmitter Output Power Measurement: 1) Connect a short single mode or multimode fiber to the FiberLink 6650 and to the transmitter port on the active equipment under test. 2) Determine the output wavelength of the active equipment and then press the Wavelength button on the FiberLink 6650 to select the correct wavelength 3) Power on the active equipment 4) Monitor the reading on the screen for a few seconds. This reading may fluctuate if the signal is digital. In this case, estimate the average power level. Transmitter Receive Signal Power Measurement: Measuring the optical power at the receive link follows the same procedure as above. However, instead of using a short patch cable, connect the FiberLink 6650 at the point in which the optical receiver will be placed. Subtract this new reading from the previous reading to calculate your loss. Actual Fiber that will be used to connect the transmitter and receiver Receiver Page 8

Measuring Optical Loss Measuring Optical Loss in a Complete System The use of the FiberLink 6650 can be extremely helpful in diagnosing trouble spots in complex fiber optic systems. The process of calculating loss for each point in the system is identical to the procedure described on the previous page. In the example system below, use a short jumper instead of the actual fiber at points 1, 3, 5 and 7 (white circle, black number) to determine the optical loss occurring within the equipment or patch panel. You will use the actual fiber at points 2, 4, 6 and 8 (black circle, white number) to determine optical loss occurring within the fiber optic cable. Subtract the new reading from the previous reading to calculate the loss that has occurred at that point in the system. Transmitter Patch Panel Optical Matrix Patch Panel Receiver 8 1 2 3 5 6 7 4 Page 9

Operating Pointers Troubleshooting Operating Pointers Remember to check attenuation of the fiber optic cable. The system will only operate properly if these specifications fall within the range of the system s loss budget. Troubleshooting Multimode fiber optic cable contains an optical fiber with a light carrying core that is only.0025 inches (62.5 microns) in diameter. Single mode fiber optic cable has an even smaller core, only.00032 to.0004 inches (8-10 microns). This is smaller than a human hair! Therefore, any minute particles of dirt or dust can easily block the fiber from accepting or radiating light. To prevent this from happening, always use the provided dust caps when ever optical connectors are exposed to air. It is also a good idea to gently clean the tip of an optical connector with a lint-free cloth moistened with alcohol whenever dust is suspected. The status of the LED screen should provide the first clue as to the origin of any operational failure. If these are off, it usually means that the battery has failed in the unit. If, after reviewing the above possibilities, the system is still not operating, please contact the Customer Service Department for further assistance. If you suspect your problem is caused by the optics or the fiber optic cable, and you have an optical power meter, please take the appropriate measurements prior to contacting support. Page 10

Maintenance & Repair Maintenance and Repairs The FiberLink 6650 Series has been manufactured using the latest semiconductor devices and techniques that electronic technology has to offer. They have been designed for long, reliable and trouble-free service and are not normally field repairable. Should difficulty be encountered, Artel Video Systems maintains a complete service facility to render accurate, timely and reliable service of all products. The only maintenance that can be provided by the user is to ascertain that optical connectors are free of dust or dirt that could interfere with light transmission and that connections are secure and accurate. All other questions or comments should be directed to our Customer Service Department. It should be noted that many problems can easily be solved by a simple telephone call. Page 11

Proven Products, Unrivaled Service, and Great Support High performance plug and play products Stand alone and card cage versions available Solutions for most video, audio, and data formats Multimode and single mode versions Designed and manufactured in the USA Training and installation support available 24x7x365 technical support available Artel Video Systems Corp. 5B Lyberty Way, Westford, MA 01886 USA T: 978-263-5775 F: 978-263-9755 sales@artel.com customercare@artel.com www.artel.com All specifications subject to change without notice. 2016 Updated 07/31/2016 CS200-129696-00_E