MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

Similar documents
FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

FACTORY AUTOMATION INSTRUCTION MANUAL. AS-Interface Safety at Work VAA-2E-G4-SN. Version 1.2

FACTORY AUTOMATION MANUAL ODZ-MAH-B15-M3

FACTORY AUTOMATION MANUAL WCS-MBG110 WCS MODBUS RTU INTERFACE MODULE

FACTORY AUTOMATION. QUICK START GUIDE VBP-HH1-V3.0-V1 AS-Interface Handheld

FACTORY AUTOMATION MANUAL PMI360D-F130-IE8-V15 INDUCTIVE POSITIONING SYSTEM

FACTORY AUTOMATION. MANUAL VBA-4E3A-G20- ZEL/M1L-P2 AS-Interface Motor Control Module

QUICK START GUIDE IC-KP2-*

MANUAL PCV Parameterization Tool

FACTORY AUTOMATION MANUAL PMI360DV-F130-IU2E2- V15

QUICK START GUIDE ODT-HH-MAH300 Handheld

FACTORY AUTOMATION INSTRUCTION MANUAL INDUCTIVE POSITIONING SYSTEM -F90

MANUAL Functional Safety

FACTORY AUTOMATION. MANUAL OHV-F230-B17 PROFINET Gateway for OHV Handheld

MANUAL Functional Safety

FACTORY AUTOMATION QUICK START GUIDE IC-KP-*

FACTORY AUTOMATION MANUAL VBP-HH1-V3.0-V1

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

MANUAL Encoders with J1939 Interface

PROCESS AUTOMATION MANUAL. Temperature Trip Amplifier. KFD2-GU-(Ex)1 ISO9001

FACTORY AUTOMATION. MANUAL IQT1-*-R4-V1 RFID R/W systems, MHz

QUICK START GUIDE 2-D Laser Scanner

MANUAL AS-INTERFACE Handheld

FACTORY AUTOMATION MANUAL VISION CONFIGURATOR

QUICK START GUIDE ODT-MAC40*-*-RD

MANUAL Functional Safety

FACTORY AUTOMATION. MANUAL R CANopen Protocol

FACTORY AUTOMATION MANUAL IQT-F116-R4-V1 IQT-F116-R4M-V1

FACTORY AUTOMATION MANUAL MAH* FIRMWARE UPGRADE INSTRUCTIONS

FACTORY AUTOMATION MANUAL CBX500 HOST INTERFACE MODULES

FACTORY AUTOMATION. QUICK START GUIDE OHV200-F22*-B15 Handheld reader

SAFETY MANUAL SIL Switch Amplifier

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

AS-i Safety Relay Output Module with Diagnostic Slave

AS-i Safety Relay Output Module with Diagnostic Slave

Operating instructions AC010S Compact AS-i E-STOP safety module

MANUAL Functional Safety

PROCESS AUTOMATION MANUAL. Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

FACTORY AUTOMATION. Manual Absolute Rotary Encoder for DeviceNet

MANUAL Installation and Configuration

FACTORY AUTOMATION INSTRUCTION MANUAL CONTROL UNIT SC4-2

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015

MANUAL LML-P, LML-S, LML-Ex

FACTORY AUTOMATION. MANUAL Absolute Rotary Encoders With EtherCAT Interface

HANDBUCH / MANUAL / MANUAL / MANUALE

MANUAL Surge Protectors

FACTORY AUTOMATION TAILORED TO YOUR APPLICATION MODULAR SAFETY MONITORING UNIT

FACTORY AUTOMATION. Manual Speed Monitor KFU8-DW-1.D

FACTORY AUTOMATION SAFETY LIGHT CURTAINS SLCS AND SLCT SERIES

PROCESS AUTOMATION MANUAL. Universal Transmitter Power Supply. KF**-CRG2-(Ex)1.D ISO9001

Operating Instructions

FACTORY AUTOMATION MANUAL LS670-DA

MANUAL SEGMENT CHECKER

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

FACTORY AUTOMATION. CONFIGURATION INSTRUCTIONS WCS3B-LS*** with RS485 interface

MANUAL Optical data coupler LS600-DA-IBS

Handbook ASI-PRG-ADR. AS-Interface Addressing Device. Festo AG & Co de 0004a

PROCESS AUTOMATION. Manual KF!!-UFT-(EX)2.D ROTATION DIRECTION INDICATOR AND CONSTANT SPEED MONITOR

to 12a Added Standard and Electrical requirements for UL table 1.1

Operating instructions. Switching amplifier DN0210 DN / / 2015

MANUAL IPT*-FP with U-P*-RX

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

FACTORY AUTOMATION. Manual IVI-KHD2-4HD1. Control Unit

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017

FACTORY AUTOMATION MANUAL CBX800

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

FACTORY AUTOMATION MANUAL IC-KP-B6-V15B IC-KP-B6-2V15B IC-KP-B6-SUBD

PROCESS AUTOMATION MANUAL. Temperature Converter. HiC2081, HiD2081, HiD2082 ISO9001

FACTORY AUTOMATION. MANUAL Absolute Rotary Encoders Integration into PROFINET

Table of Contents. AS-i Modbus Plus-Gateway Table of Contents. 1 Declaration of Conformity The Used Symbols...6

FACTORY AUTOMATION. MANUAL Absolute Rotary Encoder with PROFIBUS Interface

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

FACTORY AUTOMATION. Manual IVI-KHD2-4HD3. Control Unit with 8 Inputs/Outputs

PROCESS AUTOMATION. QUICK START GUIDE FieldConnex Diagnostic Manager

Original instructions JSHD4 AS-i Enabling device with safe AS-i input slave

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Operating instructions RFID evaluation unit DTE / / 2016

Operating instructions. Standstill monitor A / / 2011

Operating instructions IO-Link master CabinetLine AL19xx

Original operating instructions Fail-safe inductive sensor GG711S

Original operating instructions Fail-safe inductive sensor GI712S

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Polymer Electric. Operating Instructions. Control Unit SG-TRS 3X8. Version 1

MANUAL PHA...-F200-B6-V15B

MANUAL HART Multiplexer System

MANUAL Conversion instruction EDM series to VDM100 series

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

FACTORY AUTOMATION MANUAL ODT-HH-MAH120-HD HANDHELD - HIGH DENSITY

Compact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ]

Operating instructions. Speed monitor D / / 2014

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Electronic Motor DRC Functional Safety

BNI IOL-104-S01-Z012-C02

Transcription:

FACTORY AUTOMATION MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0 SAFETY AT WORK

With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.v.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship"

1 Declaration of conformity... 4 2 Safety... 5 2.1 Used Symbols...5 2.2 Intended Use...5 2.3 General notes on safety...6 2.4 Safety Monitor Requirements...6 2.5 Cabling Requirements...6 2.6 Switch or mechanical contact requirements...7 2.7 Transfer time of safety-relevant information...7 2.8 Probability of Failure on Demand Calculation...7 3 Product Description... 8 3.1 LED indicators and control buttons...8 3.2 Interfaces and connections...9 3.3 Scope of supply...10 3.4 Accessories...10 4 Installation...11 4.1 Input connections...11 4.2 AS interface...12 4.3 Auxiliary power...12 5 Commissioning...13 5.1 Configuring the AS-Interface Safety Monitor...13 5.2 Assigning an Address to the Module...13 5.3 Function Tests...13 5.4 Operating mode...13 6 Operation...14 6.1 Operating principle...14 6.1.1 Safety-Related Inputs...14 6.1.2 Cross circuit monitoring of inputs...14 6.1.3 Safety Classification...15 6.1.4 Non safety-integrated outputs...15 7 Maintenance and repair...16 3

Declaration of conformity 1 Declaration of conformity This product was developed and manufactured under observance of the applicable European standards and guidelines. Note! A Declaration of Conformity can be requested from the manufacturer. The product manufacturer, Pepperl+Fuchs GmbH, D-68307 Mannheim, has a certified quality assurance system that conforms to ISO 9001. ISO9001 4

Safety 2 Safety 2.1 Used Symbols Safety-relevant Symbols Danger! This symbol indicates an imminent danger. Non-observance will result in personal injury or death. Warning! This symbol indicates a possible fault or danger. Non-observance may cause personal injury or serious property damage. Caution! This symbol indicates a possible fault. Non-observance could interrupt devices and any connected systems and plants, or result in their complete failure. Informative Symbols Note! This symbol brings important information to your attention. Action This symbol indicates a paragraph with instructions. 2.2 Intended Use The device, together with a programmed AS-Interface safety monitor, allows the operation of sensor-controlled personal protective equipment up to category4/ple as per ISO 13849-1, or up to SIL 3 as per EN/IEC 62061, when this safety monitor is used as a safety module with safety-related inputs for connecting mechanical contacts such as emergency-stop switches and optional conventional electronic output, e.g., to activate signal lights. The maximum service life of the AS-Interface safety module is 20 years. Replace the device as a matter of course after 20 years at the latest. Safety Classification The module contains two independent, redundant input channels. If both input channels are used, the module is suitable for use up to category 4/PL e in accordance with ISO 13849-1, or SIL 3 in accordance with EN/IEC 62061. In this case, the monitor must be programmed so that dual-channel switching is monitored. If a single-channel switch is used, the module is suitable for use up to category 2/PL c in accordance with ISO 13849-1, or SIL 1 in accordance with EN/IEC 62061. Only tested and certified power supplies with safe isolation may be used to supply power. These power supplies must have PELV voltage in accordance with EN 50295 / IEC 62026-2, and a minimum MTBF of 50 years. The power supplies are designed to exclude a short circuit between the primary and secondary sides. Danger! Incorrect device connection. Do not use the outputs for safety-integrated functions. 5

Safety Approvals The device is approved in accordance with ISO 13849-1 and EN/IEC 62061. 2.3 General notes on safety Always operate the device as described in these instructions to ensure that the device and connected systems function correctly. The protection of operating personnel and plant is only guaranteed if the device is operated in accordance with its intended use. Installation and commissioning of all devices must be performed by a trained professional only. Only instructed specialist staff may operate the device in accordance with the operating manual. User modification and or repair are dangerous and will void the warranty and exclude the manufacturer from any liability. If serious faults occur, stop using the device. Secure the device against inadvertent operation. In the event of repairs, return the device to your local Pepperl+Fuchs representative or sales office. Only qualified electrical specialists are authorized to perform maintenance work. Do not open the device. Maintain ambient conditions for IP67. The operating company bears responsibility for observing locally applicable safety regulations. 2.4 Safety Monitor Requirements The device must be used only as intended as a safety-related slave in an AS-Interface segment with the corresponding AS-Interface Safety Monitor. The AS-Interface Safety Monitor must meet the requirements of the "Specification of Safe AS-Interface Transmission" system specification (version 2.01) dated 05/12/2000. To evaluate a safety-related function in accordance with a safety standard, all components found in the function must be evaluated in accordance with this standard. The wiring and programming of the safety monitor determine whether or not the required safety function performs correctly. This also applies to the required safety response after a code fault or failure (see also safety monitor documentation). The safety function (including all safetyrelated sensors) must be checked prior to initial commissioning. The safety monitor Performance Level or Safety Integrity Level (SIL) must, as a minimum, comply with the Performance Level or SIL required by the application. If a restart interlock is required for the safety function, this restart interlock must be implemented in the safety monitor. 2.5 Cabling Requirements The requirements set out in EN/IEC 60204-1 must always be observed. The requirements for the external cabling and selection of connected switches and/or mechanical contacts are based both on the level of functionality to be achieved, and on the required category (ISO 13849-1 or EN/IEC 61508). Caution! Protected cable installation Protect the cable of the safe inputs against mechanical damage in accordance with the requirements set out in EN/IEC 60204-1. In danger of manipulation, install connectors so that they are inaccessible to the operating personnel. 6

Safety 2.6 Switch or mechanical contact requirements The switches must be spring loaded. Switches combinations that guarantee an equivalent safety status (malfunction analysis) can be used. 2.7 Transfer time of safety-relevant information The transfer time depends mainly on the monitor. Read the corresponding documentation and actuating element disconnecting times. 2.8 Probability of Failure on Demand Calculation To calculate the probability of dangerous failure on demand (PFD) of a safety-related function, the PFD values for all components used within this function must be taken into consideration. In the case of dual-channel applications, the AS-Interface safe input module does not significantly contribute to the PFD or PFH (probability of dangerous failure per hour) of the overall system. The PFD and PFH values for single-channel application can be found in the data sheet. The PFD or PFH values of the other components, in particular the safety monitor, can be found in the relevant documentation. 7

Product Description 3 Product Description 3.1 LED indicators and control buttons The device has the following indicators: 1 PWR FAULT AUX O 1 O 2 S 1 S 2 ADDR 1. Status indicators Indicators Designation FAULT PWR AUX S1 S2 OUT1 OUT2 Description Fault indicator; LED red Red: communication error or address is 0 Red flashing: output supply overload AS interface voltage; LED green Green: voltage OK Green flashing: address 0 External bulk power UAUX; dual LED green/red Green: voltage OK Red: voltage, poles reversed Switching status of input channel 1; LED yellow Switching status of input channel 2; LED yellow Switching status of output 1; LED yellow/red Yellow: output active (AUX+ connected through) Red: output overload Switching status of output 2; LED yellow/red Yellow: output active (AUX+ connected through) Red: output overload 8

Product Description 3.2 Interfaces and connections 1 3 PWR FAULT AUX O 1 O 2 S 1 S 2 ADDR 5 2 4 1. Safe input 1 2. Safe input 2 3. Output 1 4. Output 2 5. Addressing socket Safety-integrated inputs Socket PIN Description Designation S1 1 Mechanical switch 1+ S1+ 2 Mechanical switch 1- S1-3 Mechanical switch 2+ S2+ 4 Mechanical switch 2- S2-5 reserved S2 1 Mechanical switch 2+ S2+ 2 Mechanical switch 2- S2-3 Not assigned 4 Not assigned 5 reserved Table 3.1 The pins 5 are reserved and should not be assigned. 9

Product Description Non safety-integrated outputs 3.3 Scope of supply The following are included in the scope of supply: Safety module Jumper Blank plug Documentation 3.4 Accessories Socket PIN Description Designation Jumper OUT1 1 Not assigned 2 Output 2 + OUT2 3 Output - AUX- 4 Output 1 + OUT1 5 Not assigned OUT2 1 Not assigned 2 Not assigned 4 Output 2 + OUT2 5 Not assigned Flat cable connection External bulk power + AUX+ External bulk power - AS interface + AS interface - 3 Output - AUX- AUX- To assign a single mechanical switch to the device (e.g. emergency-stop category 2), attach a jumper to the vacant socket on the emergency-stop connection. Insert the blank plug supplied into the vacant socket to protect this jumper from dirt and prevent it from falling out. 10

Installation 4 Installation 4.1 Input connections The switches are connected to M12 sockets. One or more series-connected mechanical switch can be connected for each channel. NC I 4 1 3 4 5 5 3 2 2 1 OUT1 OUT2 4 1 3 4 5 5 3 2 2 1 S1 S2 PWR FAULT S NC II AUX ADDR Figure 4.1 If a single-channel switch is used, use input 1. NC I NC II 4 1 3 4 5 5 3 2 2 1 OUT1 OUT2 4 1 3 4 5 5 3 2 2 1 S1 S2 PWR FAULT S AUX ADDR Figure 4.2 If input 2 remains blank, connections S2+ to S2- on the input must be bridged using the accompanying jumper. Secure the jumper using a blank plug VAZ-V1-B. 11

Installation NC I 4 1 3 4 5 5 3 2 2 1 OUT1 OUT2 4 1 3 4 5 5 3 2 2 1 S1 S2 PWR FAULT S Short-circuit jumper AUX ADDR Figure 4.3 1 mechanical switch Warning! Electrical termination caused by moisture The specified protection degree and the security function may not be guaranteed if the cable duct is not sealed correctly. 4.2 AS interface The G12 series module is connected to the AS interface via the integrated metal base. The components are connected by a yellow AS interface flat cable, e.g. VAZ-FK-S-YE. 4.3 Auxiliary power Fit protective caps (e.g. VAZ-V1-B) to vacant connectors. Use rubber seals (e.g. VAZ-FK-ST1) for the cable ends. Warning! Electrical termination caused by moisture The specified protection degree and the security function may not be guaranteed if the cable duct is not sealed correctly. Fit protective caps (e.g. VAZ-V1-B) to vacant connectors. Use rubber seals (e.g. VAZ-FK-ST1) for the cable ends. The G12 series module is connected to the auxiliary power supply via the integrated metal base. The components are connected by a black AS interface flat cable, e.g. VAZ-FK-S-BK. Warning! Electrical termination caused by moisture The specified protection degree and the security function may not be guaranteed if the cable duct is not sealed correctly. Fit protective caps (e.g. VAZ-V1-B) to vacant connectors. Use rubber seals (e.g. VAZ-FK-ST1) for the cable ends. 12

Commissioning 5 Commissioning 5.1 Configuring the AS-Interface Safety Monitor For details of necessary organizational measures affecting configuration of the safety monitor, please refer to the documentation for the safety monitor. Safety Classification The module contains two independent, redundant input channels. If both input channels are used, the module is suitable for use up to category 4/PL e in accordance with ISO 13849-1, or SIL 3 in accordance with EN/IEC 62061. In this case, the monitor must be programmed so that dual-channel switching is monitored. If a single-channel switch is used, the module is suitable for use up to category 2/PL c in accordance with ISO 13849-1, or SIL 1 in accordance with EN/IEC 62061. Only tested and certified power supplies with safe isolation may be used to supply power. These power supplies must have PELV voltage in accordance with EN 50295 / IEC 62026-2, and a minimum MTBF of 50 years. The power supplies are designed to exclude a short circuit between the primary and secondary sides. 5.2 Assigning an Address to the Module Assign an address to the module using a handheld device or an AS-Interface master. You will need an extension cable, which is available separately, if you use a handheld device. You can assign addresses from 1 to 31. The default safety module address is 0. 5.3 Function Tests Perform function tests as part of the installation by activating the safety function. The function test uncovers all existing faults at the time of installation. Because of the cross-bridging detection of safe inputs, it is not necessary to test for short circuits in the cabling. Note! In the case of single-channel safety functions, test the function for each channel. For applications of category 4/PLe as per ISO 13849-1 or SIL 3 as per EN/IEC 62061, the synchronicity of both inputs must be monitored in the safety monitor. Performing a Function Test 1. Activate the safety function by interrupting the input. This can be done by actuating a connected mechanical switch or on the cable. 2. Check whether the safety monitor detects the interruption without issuing a fault message. 3. Stop the interruption on the input on the connected mechanical switch or on the cable. 4. Enable the input on the safety monitor. 5.4 Operating mode Activating operating modes for the inputs is not possible. The parameters in the AS interface may influence the performance of the outputs. The chapter "Operating principle" contains a more accurate description. 13

Operation 6 Operation Programming the safety monitor parameters defines the safety function of the device. Read the corresponding documentation. 6.1 Operating principle 6.1.1 Safety-Related Inputs The module generates an internal code sequence. This sequence is monitored by a safety monitor (additional node) to ensure the correct order. to Outputs Code- Generator AS-i Chip DI1 S1 DI0 AS-i Bus DI2 DI3 S2 Strobe Figure 6.1 Code generator The status of the externally connected mechanical switches influences the code sequence transmission. Information regarding the activation of the connected mechanical switches (e.g. if the EMERGENCY STOP button is pressed, code transmission is interrupted) is transmitted as follows: Activated input channel Codebit 3 2 1 0 1 X X 0 0 2 0 0 X X 1 and 2 0 0 0 0 None X X X X 1) Table 6.1 1) = working state The code words 0000, XX00 and 00XX prompt the safety monitor to put the installation in safe mode (for instance using the EMERGENCY STOP button), without reporting a fault. If a code word bit differs from the target code word, the safety monitor will switch the installation to safe mode and will indicate a slave fault. The two input channels on the safety monitor are independent. The safety monitor can be programmed to monitor the input synchronicity for dual-channel applications. 6.1.2 Cross circuit monitoring of inputs The inputs are monitored for cross circuits. The cross circuit monitoring function is able to detect low-ohm cross circuits caused by a metallic connection between the two inputs. 14

Operation 6.1.3 Safety Classification The module contains two independent, redundant input channels. If both input channels are used, the module is suitable up to category 4/PL e in accordance with ISO 13849-1, or SIL 3 in accordance with EN/IEC 62061. In this case, the monitor must be programmed so that dualchannel switching is monitored. If two single-channel switches are used, the module is suitable up to category 2/PL c in accordance with ISO 13849-1,or SIL 2 in accordance with EN/IEC 62061. 6.1.4 Non safety-integrated outputs The outputs are designed in line with AS interface standards. Positive potential is applied to these outputs (PNP technology). The status of the outputs is either determined by the master device or derived from the status of the inputs, depending on the operating mode set via the parameters on the AS interface master device. The outputs can be operated in two modes: The outputs are controlled directly by the AS interface master device via the related data bits. The output signals from the AS interface master device are linked with the safe inputs. The outputs are activated by the master device or when the status of the inputs is safe. The purpose of this operating mode is to control signal lamps which indicate the status of the inputs without assistance from the master device. Mode and logic table for outputs The master device selects the modes via parameter bit P1: P1 S1 / S2 1) DO0 / DO1 2) OUT1 / OUT2 Mode 1 X / X 0 / 0 0 / 0 Outputs independent from X / X 1 / 1 1 / 1 the inputs 0 0 / 0 X / X 1 / 1 Open switch at input sets the related output Table 6.2 1 / 1 0 / 0 0 / 0 The master device controls 1 / 1 1 / 1 1 / 1 the output if the switch at the input is closed 1) 0 refers to an open switch (safe status). 1 means a closed switch. X means any status that does not effect the outputs. 2) 1 means outputs are activated, 0 means outputs are voltage-free. S1 AS-i Chip U AUX 24 V PELV P1 AS-i Bus DO0 1 OUT1 15

Maintenance and repair 7 Maintenance and repair Regular function tests may be necessary, depending on the safety category. 16

Maintenance and repair 17

FACTORY AUTOMATION SENSING YOUR NEEDS Worldwide Headquarters Pepperl+Fuchs GmbH 68307 Mannheim Germany Tel. +49 621 776-0 E-mail: info@de.pepperl-fuchs.com USA Headquarters Pepperl+Fuchs Inc. Twinsburg, Ohio 44087 USA Tel. +1 330 4253555 E-mail: sales@us.pepperl-fuchs.com Asia Pacific Headquarters Pepperl+Fuchs Pte Ltd. Company Registration No. 199003130E Singapore 139942 Tel. +65 67799091 E-mail: sales@sg.pepperl-fuchs.com www.pepperl-fuchs.com Subject to modifications Copyright PEPPERL+FUCHS Printed in Germany 205098 / DOCT-1396A 11/2014